Back to search

Washington University in St. Louis

Alternating Minimization Algorithms for Dual-Energy X-Ray CT Imaging and Information Optimization

Abstract

dc:description.abstract

This dissertation contributes toward solutions to two distinct problems linked through the use of common information optimization methods. The first problem is the X-ray computed tomography (CT) imaging problem and the second is the computation of Berger-Tung boundsfor the lossy distributed source coding problem. The first problem discussed through most of the dissertation is motivated by applications in radiation oncology, including dose prediction in proton therapy and brachytherapy.In proton therapy dose prediction, the stopping power calculation is based on estimates of the electron density and mean excitation energy. In turn, the estimates of the linear attenuation coefficients or the component images from dual-energy CT image reconstruction are usedto estimate the electron density and mean excitation. Therefore, the quantitative accuracy of the estimates of the linear attenuation coefficients or the component images affects the accuracy of proton therapy dose prediction.In brachytherapy, photons with low energies (approximately 20 keV) are often used for internal treatment. Those photons are attenuated through their interactions with tissues. The dose distribution in the tissue obeys an exponential decay with the linear attenuation coefficient as the parameter in the exponential. Therefore, the accuracy of the estimates ofthe linear attenuation coefficients at low energy levels has strong influence on dose prediction in brachytherapy.Numerical studies of the regularized alternating minimization (DE-AM) algorithm with different regularization parameters were performed to find ranges of the parameters that can achieve the desired image quality in terms of estimation accuracy and image smoothness.The DE-AM algorithm is an extension of the AM algorithm proposed by O'Sullivan and Benac. Both simulated data and real data reconstructions, as well as system bias and variance experiments, were carried out to demonstrate that the DE-AM algorithm isincapable of reconstructing a high density material accurately with a limited number of iterations (1000 iterations with 33 ordered subsets). This slow convergence phenomenon was then studied via a toy. or scaled-down problem, indicating a highly ridged objective function.Motivated by the studies which demonstrate the slow convergence of the DE-AM algorithm, a new algorithm, the linear integral alternating minimization (LIAM) algorithm was developed, which estimates the linear integrals of the component images first; then the componentimages can be recovered by an expectation-maximization (EM) algorithm or linear regression methods. Both simulated and real data were reconstructed by the LIAM algorithm while varying the regularization parameters to ascertain good choices ( &delta= 500; &lambda= 50 for I0 =100000 scenario). The results from the DE-AM algorithm applied to the same data were used for comparison. While using only 1/10 of the computation time of the DE-AM algorithm, the LIAM algorithm achieves at least a two-fold improvement in the relative absolute errorof the component images in the presence of Poisson noise.This work also explored the reconstruction of image differences from tomographic Poisson data. An alternating minimization algorithm was developed and monotonic decrease in the objective function was achieved for each iteration. Simulations with random imagesand tomographic data were presented to demonstrate that the algorithm can recover the difference images with 100% accuracy in the number of and identity of pixels which differ. An extension to 4D CT with simulated tomographic data was also presented and an approachto 4D PET was described.Different approaches for X-ray adaptive sensing were also proposed and reconstructions of simulated data were computed to test these approaches. Early simulation results show improved image reconstruction performance in terms of normalized L2 norm error compared to a non-adaptive sensing method.For the second problem, an optimization and computational approach was described for characterizing the inner and outer bounds for the achievable rate regions for distributed source coding, known as Berger-Tung inner and outer bounds. Several two-variable exampleswere presented to demonstrate the computational capability of the algorithm. For each problem considered that has a sum of distortions on the encoded variables, the inner and outer bound regions coincided. For a problem defined by Wagner and Anantharam witha single joint distortion for the two variables, their gap was observed in our results. These boundary regions can motivate hypothesized optimal distributions which can be tested in the first order necessary conditions for the optimal distributions.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (PhD)
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Electrical and Systems Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Chen, Yaqi
Contributors dc:contributor
  • Joseph A O'Sullivan

Rights

Language dc:language
English (en)

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Washington University in St. Louis
Base URL
openscholarship.wustl.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Chen, Yaqi. Alternating Minimization Algorithms for Dual-Energy X-Ray CT Imaging and Information Optimization. Dissertation thesis, https://repository.library.washu.edu/etd/1291