Back to search

York University

Secondary Moment Effects on Slender Reinforced Masonry Walls

Abstract

dc:description.abstract

Slender masonry walls can be an effective loadbearing component of buildings that require high ceilings such as warehouses and gymnasiums. This type of construction is also efficient in terms of material usage and over-all construction costs. The proven long-term durability of existing masonry buildings makes this construction material an attractive option; however, the limited experimental testing on slender walls in out-of-plane flexure combined with high axial loads have led to conservative prescriptive restrictions on their design in Canadian and U.S. standards. The experimental testing presented herein aims to advance knowledge on Reinforced Masonry (RM) walls and introduces a novel method of reinforcement for new masonry wall construction. This novel method consists of applying Near-Surface Mounted (NSM) steel reinforcement rather than conventional embedded reinforcement. The first phase of the research included numerical Finite Element (FE) analysis and experimental testing of 3 m tall RM walls subjected to four-point out-of-plane loading; the second phase consisted of experimental testing of 8 m tall slender (slenderness ratio kh/t = 42) RM walls subjected to combined axial loading and four-point out-of-plane loading. For both phases, the flexural stiffness (EI) of the walls was assessed through multiple approaches (using reinforcement strain, surface strain, and out-of-plane displacement data), and compared to the stiffness calculated using the current Canadian masonry design standard (CSA S304-14) formulation. The equation for the effective flexural stiffness in the current design standard was observed to underestimate the stiffness response in most loading conditions, however it does not provide a consistently accurate value. An alternative method for calculating flexural stiffness was therefore proposed, which accounts for loss of stiffness from repeated loading, or accidental overload, as well as the effect of applied axial loads. Throughout this dissertation, the performance of RM walls with conventional embedded reinforcement is compared to the performance of walls with NSM steel bars. RM walls with NSM steel reinforcement exhibited higher flexural stiffness, and displacement ductility comparable to or exceeding that of RM walls with conventional reinforcement. In addition, a design example illustrated how NSM steel reinforcement can be beneficial for the design of walls with large secondary moment effects.

Degree

thesis:*
Name thesis:degree_name
PhD - Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Civil Engineering
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sparling, Adrien Joseph James
Advisor dc:contributor.advisor
  • Palermo, Dan

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Author owns copyright, except where explicitly noted. Please contact the author directly with licensing requests.
Language dc:language
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10315/40659

Chain of custody

source
Harvested from
York University
Base URL
yorkspace.library.yorku.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Sparling, Adrien Joseph James. Secondary Moment Effects on Slender Reinforced Masonry Walls. Doctoral thesis, 2022. https://hdl.handle.net/10315/40659