Back to search

York University

Progress Towards a Precision Measurement of the n = 2 Triplet P0-to-n = 2 Triplet P1 Transition in Atomic Helium

Abstract

dc:description.abstract

Significant progress towards a high-precision measurement of the 29.6 GHz 2^3P_1-to-2^3P_0 fine-structure interval in helium at an intended precision of 20 Hz is presented. The measurement is performed using a thermal beam of metastable helium atoms, and the transition is measured using the frequency-offset separated oscillatory fields (FOSOF) method, where the transition is driven by a pair of temporally separated microwave pulses. The two pulses are at slightly different frequencies, which can be viewed as a continuously advancing phase difference between the pulses. The advancing phase difference leads to a sinusoidally varying atomic signal due to quantum interference between atoms excited during the two pulses. The phase difference between the sinusoidal atomic signal and a reference signal generated by combining the two microwave frequencies is zero at resonance and approximately proportional to the difference between the applied microwave frequency and the centre frequency of the transition. A large number of experiment parameters which could lead to systematic effects have been investigated and shown to be sufficiently well-managed at the intended precision level of the intended measurement. One effect which causes the measured linecentre to depend on the range of microwave frequencies at which data is taken has been thoroughly investigated in both experiments and in a numerical simulation developed to investigate systematic effects. This effect is still not sufficiently well-understood or controlled to allow completion of a measurement at the 20 Hz level of precision. A completed measurement, at a precision of 20 Hz, would be able to be combined with our previous 25 Hz measurement of the 2.3 GHz 2^3P_2-to-2^3P_1 interval to obtain a part-per-billion (ppb) determination of the combined 31.9 GHz 2^3P_2-to-2^3P_0 interval. When compared to a sufficiently-precise theoretical calculation, the combined interval would allow a 0.5 ppb determination of the fine-structure constant, the most precise determination of the fine-structure constant in a two-electron system and within an order of magnitude of the most precise determinations of the fine-structure constant. This 0.5 ppb determination could be compared with other fine-structure constant determinations to test beyond-the-Standard-Model physics.

Degree

thesis:*
Name thesis:degree_name
PhD - Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Physics And Astronomy
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Skinner, Taylor David Grant
Advisor dc:contributor.advisor
  • Hessels, Eric

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Author owns copyright, except where explicitly noted. Please contact the author directly with licensing requests.
Language dc:language
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10315/41956

Chain of custody

source
Harvested from
York University
Base URL
yorkspace.library.yorku.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Skinner, Taylor David Grant. Progress Towards a Precision Measurement of the n = 2 Triplet P0-to-n = 2 Triplet P1 Transition in Atomic Helium. Doctoral thesis, 2024. https://hdl.handle.net/10315/41956