Back to search

York University

Vulnerability Assessment of Power Transformers and Power Systems to Geomagnetic Disturbances

Abstract

dc:description.abstract

Powerful solar storms emit plasma that may travel towards the earth. Interactions between the plasma and the earth magnetic field cause geomagnetic disturbances (GMDs), which in turn induce quasi-dc voltage along long conductors in power systems. Assessing the power system resiliency against GMDs requires accurately calculating the induced electric fields and the resultant geomagnetically induced currents (GICs). Offline and online wide-area geomagnetic field monitoring systems are established in this research to estimate GIC flows in power systems accurately. The proposed monitoring systems process the magnetic field signals that are measured at several observatories worldwide. In the offline monitoring system, the magnetic field signals are denoised, and spikes are detected and replaced. The time derivative of the signal is taken by a continuous wavelet transform to prevent amplification of the noises. GICs in a modified IEEE 118-bus benchmark power system are calculated concerning a realistic geomagnetic storm to demonstrate the effectiveness of the proposed signal processing methods. A sliding window is applied in the online monitoring system, and its size is optimized to lower processing time while increasing the signal-to-noise ratio. High amplitude GICs can cause a sharp increase in the hottest-spot temperature of the power transformers. The high temperature allows the formation of gaseous bubbles in the oil-paper insulation and endangers the integrity of the transformer's insulation system. The bubbles include mainly water vapor and emerge in the cavities on the surface of the paper insulation. In the experimental phase of this research, a test setup is created to detect bubbling inception temperature (BIT) for Kraft and thermally upgraded papers (TUPs). The paper samples are dried, prepared at six different moisture levels, and immersed in synthetic ester oil for the experiments. The paper strips are wound around a cartridge heater, and a controller unit raises its temperature at 3 ºC/min and 20 ºC/min rates to detect BIT. The BITs are considered the operational limit on the hottest-spot temperature of the transformers.

Degree

thesis:*
Name thesis:degree_name
PhD - Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Electrical Engineering & Computer Science
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ariannik, Mohamadreza
Advisor dc:contributor.advisor
  • Rezaei Zare, Afshin

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Author owns copyright, except where explicitly noted. Please contact the author directly with licensing requests.
Language dc:language
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10315/41976

Chain of custody

source
Harvested from
York University
Base URL
yorkspace.library.yorku.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Ariannik, Mohamadreza. Vulnerability Assessment of Power Transformers and Power Systems to Geomagnetic Disturbances. Doctoral thesis, 2024. https://hdl.handle.net/10315/41976