• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 101
  • 78
  • 22
  • 20
  • 16
  • 7
  • 6
  • 5
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 297
  • 297
  • 133
  • 129
  • 67
  • 66
  • 58
  • 56
  • 55
  • 54
  • 51
  • 49
  • 47
  • 42
  • 42
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Design of a three phase four quadrant variable speed drive for permanent magnet brushless DC motors

Dakora, Jonas-Yelee January 2016 (has links)
Submitted in fulfillment of the requirements for the Master of Engineering Degree, Department of Electronic Engineering, Durban University of Technology, Durban, South Africa, 2016. / The aim of this research project is to design a three phase four quadrant variable speed drive (VSD) for a permanent magnet brushless direct current motor (PMBLDC) that can be applied to an electric bicycle (e-bike). The design is confined to PMBLDC motors with a maximum power rating of 1.5kW. The speed controller operates in current mode at a maximum voltage and current rating of 50V and 30A, respectively. The VSD has the ability to smoothly control the current delivered to the DC motor and therefore controls its torque. The motor’s current is limited in all four quadrants of operation, and its speed is limited in the forward and reverse directions. The performance of the proposed DC motor VSD system is tested on an electric- bicycle. The PMBLDC motor has three hall sensors embedded into the stator to determine rotor position. A phase switcher module interprets the position signals and produces a switching pattern. This effectively transforms the BLDC motor into a direct current (DC) brushed motor. The unipolar switching scheme used ensures that current flows out of the battery only for motoring operation and into the battery during regenerative braking. The current and torque are directly proportional in a BLDC motor. Torque control is achieved in the BLDC motor using a single channel current controller. The phase switcher current is monitored and used to control the duty cycle of the synchronous converter switches. The proposed e-bike speed control system provides efficient control in all four quadrants of operation and it is a suitable alternative for a low cost transportation mode. / M
12

Non-invasive brain stimulation as a novel approach to the treatment of chronic non-specific low back pain

O'Connell, Neil Edward January 2012 (has links)
Chronic non-specific low back pain (CNSLBP) is a widespread but poorly understood condition that places a substantial burden on the sufferer, health services and the wider economy. Existing approaches to management do not demonstrate impressive levels of effectiveness. There is growing evidence that CNSLBP is associated with significant alterations in central nervous system (CNS) structure and function, suggesting a possible role for the brain in the aetiology of the condition, and presenting a case for novel therapies which aim to treat CNSLBP by affecting brain function. One such potential therapeutic approach is non-invasive brain stimulation (NIBS). Following a literature review discussing the epidemiology and management of low back pain, the evidence for altered CNS function and the potential role of brain stimulation in CNSLBP and chronic pain generally this thesis includes 3 original scientific studies: (i) A Cochrane systematic review of the effectiveness of NIBS techniques for the treatment of chronic pain; (ii) A randomised double-blind exploratory study of transcranial direct current stimulation of the motor cortex in the treatment of CNSLBP; (iii) Is blinding to the stimulation condition maintained in trials comparing 2mA tDCS with sham stimulation? A randomised cross-over study. Results: There is limited existing evidence that some forms of NIBS may have a beneficial effect on chronic pain, though caution is warranted. Exploratory data from study 2 is not suggestive that tDCS to the motor cortex is effective for treating CNSLBP. Commonly used sham controls in trials of tDCS do not ensure adequate blinding, and so introduce a potential source of bias to the existing evidence base. Conclusion: Further research is required to establish the value of NIBS as a treatment for chronic pain and CNSLBP. Future research in tDCS will need to develop and employ fully validated sham controls to ensure adequate blinding. NIBS cannot currently be recommended for the treatment of CNSLBP.
13

Investigating the effects of altitude (air density) on the HVDC breakdown voltage of small rod-plane air gaps

Gora, Tatenda January 2016 (has links)
A dissertation submitted to the Faculty of Engineering and the Built Environment, University of the Witwatersrand, Johannesburg, in fulfilment of the requirements for the degree of Master of Science in Engineering, 2016 / The validity of the atmospheric correction method presented in the IEC 60060-1 (2010) standard is analysed and evaluated by means of theoretical and laboratory work. In order to understand the problem, the evolution of the atmospheric correction methods, from as early as 1914, has been presented. A procedure (Calva prediction method) for predicting the direct current (DC) breakdown voltage for an air gap at any altitude was discovered and was also analysed along with the IEC 60060-1 (2010). A critique of some of the atmospheric correction methods commonly used standards was also done. Experiments were carried out at altitudes of 1 740 m (Wits University), 130 m (UKZN HVDC centre) and at less than 2 m above sea level (Scottburgh beach, Clansthal). More tests were conducted using a pressure vessel where high altitude relative air density was simulated. All tests were conducted on rod-plane air gaps using a 15 mm diameter at tip rod. Test results from Scottburgh beach were used as the standard breakdown voltages of the air gaps tested since the environmental conditions were the closest to the conventional standard conditions (stp). The test results obtained were compared with predictions using the Calva method in order to validate the method. The test results were also corrected according to IEC 60060-1 (2010) and compared to the standard breakdown voltages obtained at Scottburgh beach. It was shown that the IEC 60060-1 (2010) is quite suitable for atmospheric correction for data obtained at low altitudes (about 130 m). When applied to high altitude (1 740 m) data, the correction method is accurate and suitable for very small air gaps less than 0.1 m. As the air gap length increased, the corrected results began to deviate from the expected standard voltage. The same trend was shown with the corrected results from the pressure chamber tests. The prediction method by Calva was accurate when compared to the experimental data from the high altitude and low altitude test results. When compared to the data from the pressure chamber, the prediction method had a linear error factor which was di erent for each gap length. It was concluded that the IEC 60060-1 (2010) is not only unsuitable for atmospheric correction for data at relative air densities below 0.8, but also that the correction method is prone to an increase in error as the air gap length increases when the relative air density is higher than 0.8. The Calva prediction method was found to be suitable to use after additional factors are added when applied to high altitude conditions. / GR2016
14

A digital speed control for a chopper-fed DC motor by using the INTEL 8080 microcomputer

Lin, Andrew Kou-Chu January 2011 (has links)
Digitized by Kansas Correctional Industries
15

Ground Monitoring using Resistivity Measurements in Glaciated Terrains

Aaltonen, Jaana January 2001 (has links)
The most common method of monitoring and mapping groundwatercontaminants is to extract and analyse a number of groundwatersamples from wells in the investigation area. However, thereare a number of limitations with this type of point-wiseinvestigation, as it is hard to acquire an adequate picture ofa heterogeneous and anisotropic subsurface using a fewpoints. To overcome the limitations of point investigations and toimprove ground monitoring investigations in a cost-effectiveway, support can be provided by direct current resistivitymeasurements, which give a characterisation of the electricalproperties of a ground volume. The main objective with this work was to investigate theusability of the resistivity method as a support in monitoringgroundwater contaminants in glaciated terrains and underdifferent seasons, both in long-term monitoring programmes andintracer tests. The work comprised field investigations at several differentsanitary landfills and four tracer tests in differentgeological environments, around the Stockholm region. The maininvestigations have been done at Högbytorp, Stockholmwhich has been used for long-term investigations of theresistivity variation, together with a field set up formonitoring and measurements on seasonal variation in soilmoisture, ground temperature and precipitation. It can be concluded that the use of resistivity measurementssupplies valuable information in the case of mapping andmonitoring conductive groundwater contaminants andfurthermore: The variation in resistivity (in shallow investigations<1 m) can be extensive between different seasons (around30 % compared to a mean value in till and clay soils) andshould be considered, so that anthropogenic affects can beseparated from natural resistivity variation. For deeperinvestigations (>5 m) the seasonal resistivity variationwas more moderate (around 15% compared to a mean value intill and clay soils). Soil moisture variation shows a strong relationship toresistivity variation in the investigated clay and tillsoils. Together with temperature correction 47 to 65% of thevariation has been explained. Three types of monitoring systems can be applied:Permanently installed, partly installed and fully mobilesystems. For the actual measurements, all three types can useeither high-density techniques such as CVES (ContinuousVertical Electrical Sounding) or low-density measuring withone or some different electrode spacings. The suggested evaluation tool for monitoring programmesshowed that it was possible to detect a decrease of 15 % inthe mean value at a specific site using Modified Double Masscalculations between resistivity time series and time seriesat a reference site with a comparable seasonalvariation. Resistivity measurements may be used as a valuablecomplement to groundwater sampling in tracer tests. Adecrease in resistivity, a minimum and a recovery phasereflect the passage of a NaCl-solution, which can be used toestimate flow velocity and flow patterns of the investigatedaquifer. The achieved recovery of NaCl in the tracer testscarried out was estimated to 20 to 70 %. The measurement system for long-term monitoring or tracertests, which should be chosen with regard to layout andfrequency, depends on the purpose of measurement and onsite-specific conditions and therefore no standard solutioncan be proposed. Key words:Resistivity, Direct Current, Monitoring,Groundwater, Contaminant, Tracer test, Geophysics.
16

Investigations into the upgrading of transmission lines from HVAC to HVDC.

Naidoo, Pathmanathan. January 2007 (has links)
Emanating from the proceedings of CIGRE 2004, a new idea for higher power transmission by recycling and up rating high voltage alternating current transmission lines for high voltage direct current application was presented at the HYDC working group session. To date, there is no known application of the idea. Globally, transmission congestion, power transfer bottlenecks with restricted and limited power transfers and unobtainable servitudes challenge electric power utilities. The literature review shows that since the early sixties, several authors have studied this proposal. However, no applications were done. Admittedly, early HYDC technology was troubled by problems with multi-terminal designs, external insulation breakdown in the presence of DC stress and mercury valve rectifiers struggled with arc backs. To date, power electronic and external insulation technology has grown and matured for confident application both in point to point and multi-terminal application. The economic costs of introducing the DC technology are also more affordable given reducing prices due to higher volume of purchases. With promising developments in insulation and power electronic technology and driven by South Africa's surging growth in the consumption of electrical energy; the subject of upgrading HYAC transmission for HYDC application is revisited. For the research, the emphasis is beyond FACTS and towards a solution that could develop into a new supergrid that could overlay the existing national grid. Thus, the solution is prepared specifically for the case of recycling existing assets for higher power transfers. The working environment is defined by the difficulty in acquiring new powerline servitudes, transmission congestion in complex networks, the need for electrical islands within complex interconnections, and the need for enhanced power system stability and to promote new ancillary services energy management. The focus of this research study was to determine the technical feasibility of upgrading of existing HYAC circuits for HYDC application. It is assumed that the transmission line will remain as is in structure, layout and mechanical design. The changing of external line insulators using live line technology is an accepted modification to the original HYAC line, if required. From the study, we conclude that not all HYAC lines are recommended for upgrade to HYDe. We introduce boundary conditions as a first step towards checking on the suitability of the proposed upgrade from HVAC to HYDC mode. Emanating from this study, the first paper published introduced the initial boundary conditions as being only those lines where the "unused gap" between surge impedance loading and conductor current carrying capability is appreciable and large; generally three to four times surge impedance loading. In the case where the unused gap is the smallest or negligible, then we do nothing. In between, where the unused gap is about two to three times the surge impedance loading, then we can consider active or passive compensation using the HVAC FACTS technology options as proposed by EPRl. Having determined the candidate transmission line configuration for the proposed upgrade to HYDC application, we select the DC operating voltage as based on the voltage withstand capability of external insulation for varying environmental conditions. In addition, the DC voltage will generate allowable electrical fields and corona effects within and outside the transmission servitude. The optimum DC operating voltage would satisfy the conditions of minimum transmission power losses and volt drop for the case of maximum power transfers; within the limits of electrical fields and corona effects. / Thesis (M.Sc.Eng.)-University of KwaZulu-Natal, Durban, 2007.
17

Protection of ultra long HVDC transmission lines.

Naidoo, Divoloshanan. January 2005 (has links)
HVDC transmission is today widely used in modem Power Systems as an alternative to HVAC. Current trends indicate that many future conventional HVDC systems will be systems of increasing power ratings, delivered over larger distances as well as multi-terminal systems. In order to ensure the security and dependability of such systems, the current protection schemes need to be evaluated to assess their ability to provide adequate protection for the envisaged HVDC systems. This research work firstly reviews the present HVDC transmission line protection systems, and highlights their advantages and disadvantages, including factors that adversely influence their performance. The author critically evaluates the current protection schemes and reveals the drawbacks and other factors that render them unsuitable for the protection oflong dc transmission lines. The author then goes on to propose and develop an HVDC line protection system that will be able to provide adequate protection for proposed long HVDC transmission lines. The proposed protection system is able to make decisions based solely on local detection increasing its overall reliability. The author then recommends that the proposed protection system be used in conjunction with the existing main protection system in order to optimise the protection response times for both close in and distant faults. The author also proposes and develops a method of further enhancing the reliability of the protection system by the use of the telecommunication infrastructure when available. Finally the performance and feasibility of the proposed protection system is evaluated using the results obtained from the extensive fault simulations performed in EMTDC and Matlab. The simulations are performed using a bipole model of an HVDC System on which the required line and protection systems are modelled. The simulation results obtained are very favourable and promote the use of this proposed protection system, for the protection of long HVDC transmission lines. / Thesis (M.Sc.Eng.)-University of KwaZulu-Natal, Durban, 2005.
18

A study of high voltage direct current conductor corona in a purpose built corona cage.

Sibilant, Gary Charles. January 2003 (has links)
The main aim of this study was concerned with the design and commissioning of a corona cage, which could be used under Direct Current (DC) conditions. The cage was designed based on empirical formulas and equations as well as electric field simulations. The designed cage was then fabricated. The commissioning of the cage was undertaken in the High Voltage Direct Current (HVDC) laboratory at the University of Durban - Westville (UDW). Tests to determine the effects of a silicone coating as well as wind on the corona performance of conductors were undertaken. The tests were done in order to determine ways of improving the corona performance of conductors under HVDC potential. The tests were carried out using various conductor surface conditions. The wind tests were made possible by using a powerful fan. A silicone coating was also used to determine the effects that it would have in mitigation of corona activity on HVDC conductors. The conductors were tested without the coating, with half of their length coated and then fully coated. Results showed that the effect of wind on corona generation in a corona cage is minimal. The effect of the silicone coating was that it increased the corona currents measured in the corona cage. The conductors with no coating generated the lowest currents, the half coated conductors generated the second highest measured currents and the fully coated conductors generated the most corona. Analysis of the increased currents showed that the increase in corona currents due to the silicone coating could be attributed to three factors. Firstly the coating caused an increase in conductor to cage capacitance. Secondly, partial discharges could have occurred in the silicone due to microscopic air particles and lastly, the increase in corona currents could be ascribed to the effect of the boundary conditions on the boundary between the conductor and the coating. / Thesis (M.Sc.)-University of Durban-Westville, 2003.
19

A study of the electrical environment below HVDC transmission lines.

Govender, Dhevandhran. January 2008 (has links)
The main aim of this project was to determine the extent to which the study of electric fields and ions in a laboratory can be used to study the electrical environment below High Voltage Direct Current (HVDC) transmission lines. The focus of the study was to set up small scale laboratory experiments and to compare these results to actual line measurements and to software simulations. The laboratory tests were undertaken at the HVDC Centre at the University of KwaZulu-Natal (Westville Campus). The software simulations that were conducted as part of this study were done using EPRI TL 3.0 and Microsoft Excel. Initially tests conducted were the measurement of the induced voltage and corona leakage current on a floating object. The next set of laboratory tests conducted was the measurement of ion current density and the electric field at ground level. The ion current density was measured with a Wilson Plate (lm2) and the electric field at ground level was measured using a JCI static monitor field meter (JCI 140) and a Monroe (257D) Portable Electrostatic Fieldmeter, with an elevated earth plane. Measurements of ion current density and electric field at ground level were also taken under an operating HVDC transmission line (Cahora Bassa to Apollo), in order to compare the laboratory measurements and simulations with real line measurements. The results have shown that the electrical parameters (i.e. ion current, induced voltages, corona currents, electric field, ion density, space charge) are higher under the negative pole as compared to the positive pole. The results of the laboratory measurements show that the ion currents under the negative polarity are almost double the ion currents that were measured under positive polarity, while the electric field under negative polarity was 20 percent higher than under positive polarity. Measurements of the electric field show that the total electric field below the line is greatly enhanced when corona generated space charge is present. The results of the EPRI TL Workstation simulations show good correlation with the EXCEL® simulations. However, there was poor correlation between EPRI simulations and test line measurements in the laboratory. The EPRI simulations show good correlation to the measured electric field values below the Cahora Bassa line. The comparison between the actual measurements on the test line and the Cahora Bassa line showed poor correlation and this was attributed to factors such as scaling, laboratory size constraints, ion concentration in laboratory, line loading and wind speeds. / Thesis (M.Sc.Eng.)-University of KwaZulu-Natal, Durban, 2008.
20

Modulating dynamic stiffness of a direct-drive brushless linear DC motor

Miller, Joel Christopher 08 1900 (has links)
No description available.

Page generated in 0.0431 seconds