• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 98
  • 26
  • 5
  • 4
  • 4
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 164
  • 164
  • 88
  • 22
  • 21
  • 21
  • 20
  • 20
  • 16
  • 14
  • 13
  • 13
  • 13
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

An analysis and synthesis procedure for feedback FM systems.

January 1963 (has links)
No description available.
82

Transatlantic frequency-modulation experiments

January 1954 (has links)
L.B. Arguimbau ... [et al.]. / "September 20, 1954." / Bibliography: p. 49. / Army Signal Corps Contract DA36-039 sc-42607 Project 132B Dept. of the Army Project 3-99-12-022
83

The use of frequency modulation for television transmission

January 1953 (has links)
R.D. Stuart ... [et al.]. / "July 6, 1953." / Bibliography: p. 10. / Army Signal Corps Contract No. DA36-039 sc-100 Project No. 8-102B-0 Dept. of the Army Project No. 3-99-10-022
84

Interference rejection in FM receivers

January 1956 (has links)
Elie J. Baghdady. / "September 24, 1956." "This report is based on a thesis submitted to the Department of Electrical Engineering, M.I.T., May 16, 1956, in partial fulfillment of the requirements for the degree of Doctor of Science." / Bibliography: p. 106. / Army Signal Corps Contract DA36-039-sc-64637 Dept. of the Army Task 3-99-06-108 Project 3-99-00-100
85

Interference in frequency-modulation reception

January 1949 (has links)
J. Granlund. / "January 20, 1949." / Bibliography: p. 79. / Army Signal Corps Contract No. W36-039-sc-32037 Project No. 102B. Dept. of the Army Project No. 3-99-10-022.
86

Results of transient analysis of impulse noise in FM receivers

January 1947 (has links)
T.P. Cheatham, Jr. and W.G. Tuller. / "January 20, 1947." / Includes bibliographical references.
87

Measurement of carbon dioxide corrosion on carbon steel using electrochemical frequency modulation

Sridharan, Venkatasubramaniyan 15 July 2009
Electrochemical frequency modulation (EFM), which has been widely used in the research field of semiconductors, was used to study CO2 corrosion on carbon steel under film forming and non-film forming conditions. In the EFM technique two sinusoidal voltage signals of different frequencies are applied to the system and the response current is measured at zero, harmonic and intermodulation frequencies from which the corrosion rate is calculated. The corrosion rate calculation depends upon whether the system is under activation, diffusion or passivation control. In this research rotating cylindrical electrodes made of AISI carbon steel 1018 were immersed in 3% (w/w) NaCl solution saturated with carbon dioxide. The experiment was done at 5 rpm, 24 rpm and 100 rpm simulating laminar, transient and turbulent flow regions respectively. The exposure time was varied from 1 hour to 24 hours and the results were compared with other electrochemical methods such as linear polarization (LP) and electrochemical impedance spectroscopy (EIS). It was found that it was crucial to select the correct EFM model to ensure accurate corrosion rate measurement. A very good agreement in the polarization resistance was obtained between EIS and EFM indicating that EFM can be used as an effective tool in corrosion studies providing that the corrosion mechanism is known.
88

Measurement of carbon dioxide corrosion on carbon steel using electrochemical frequency modulation

Sridharan, Venkatasubramaniyan 15 July 2009 (has links)
Electrochemical frequency modulation (EFM), which has been widely used in the research field of semiconductors, was used to study CO2 corrosion on carbon steel under film forming and non-film forming conditions. In the EFM technique two sinusoidal voltage signals of different frequencies are applied to the system and the response current is measured at zero, harmonic and intermodulation frequencies from which the corrosion rate is calculated. The corrosion rate calculation depends upon whether the system is under activation, diffusion or passivation control. In this research rotating cylindrical electrodes made of AISI carbon steel 1018 were immersed in 3% (w/w) NaCl solution saturated with carbon dioxide. The experiment was done at 5 rpm, 24 rpm and 100 rpm simulating laminar, transient and turbulent flow regions respectively. The exposure time was varied from 1 hour to 24 hours and the results were compared with other electrochemical methods such as linear polarization (LP) and electrochemical impedance spectroscopy (EIS). It was found that it was crucial to select the correct EFM model to ensure accurate corrosion rate measurement. A very good agreement in the polarization resistance was obtained between EIS and EFM indicating that EFM can be used as an effective tool in corrosion studies providing that the corrosion mechanism is known.
89

Design and implementation of pulse sequences for application in MRI /

Jang, Geon-Ho, January 1999 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 1999. / Typescript. Vita. Includes bibliographical references (leaves 118-123). Also available on the Internet.
90

Design and implementation of pulse sequences for application in MRI

Jang, Geon-Ho, January 1999 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 1999. / Typescript. Vita. Includes bibliographical references (leaves 118-123). Also available on the Internet.

Page generated in 0.0398 seconds