• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 198
  • 78
  • 32
  • 23
  • 11
  • 6
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 415
  • 415
  • 180
  • 177
  • 38
  • 37
  • 34
  • 32
  • 30
  • 29
  • 27
  • 26
  • 25
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Efeitos de raios-X de baixa energia em células mamárias / Effects of low energy x-rays in mammary cells

Flávia Ventura dos Passos 12 August 2011 (has links)
Doses de radiação de baixa energia podem induzir quebras de dupla fita no DNA assim como também produzir perfis alterados de expressão de genes relacionados a estas lesões. Os danos não reparados ou mal reparados levam a uma maior suscetibilidade à transformação oncogênica já que os efeitos biológicos mais importantes causados pela radiação ionizante são mutação e carcinogênese. As lesões no DNA provocadas pela radiação podem também ocasionar o surgimento micronúcleos e as células podem ser induzidas à apoptose. O objetivo deste trabalho é estudar in vitro a presença de micronúcleos e a apoptose ocasionados por Raios-X de baixa energia. Pretende-se analisar estes efeitos biológicos em relação à energia equivalente à utilizada em exames mamográficos usando duas linhagens estabelecias de células de mama: a MCF-7 (tumoral) e a HB-2 (não-tumoral). As células, em crescimento exponencial, foram irradiadas no equipamento de arranjo experimental de mamografia do LCR/UERJ. A dose de 5Gy na energia de 30 kV foi aplicada com taxa de 0,1 Gy/seg utilizando filtro de 0,03 mm de molibdênio. As irradiações foram realizadas duas vezes, após as irradiações, as células foram incubadas por 4, 24 ou 48 horas e posteriormente coradas com o corante Hoechst33258 para análise em microscopia de fluorescência. Para cada análise, 1000 células foram categorizadas pela morfologia do núcleo. Os resultados mostraram que a HB-2, utilizada neste estudo como célula mamária normal, apresentou maior sensibilidade aos efeitos da radiação, com 37 % das células em apoptose após 4 hs de incubação, enquanto a MCF-7 apresentou 6,5 %. Nas análises após 24 hs foi possível confirmar a radioresistência da MCF-7 tendo sido observadas 11% de células em apoptose no grupo irradiado. Houve um aumento crescente de micronúcleos radioinduzidos nas duas linhagens de acordo com os tempos de incubação. Na análise de 4 hs a HB-2 apresentou 3%, em 24 hs, 8,5% e 48 hs, 11,5 %. Diante destes resultados, foi possível concluir que a energia do feixe de raios-X utilizada na mamografia pode ser capaz de ocasionar aumento de ocorrência de apoptose e geração de micronúcleos nas duas linhagens estudadas / Radiation doses of low-energy can induce double-stranded breaks in DNA as well resulting in altered profiles of gene expression related to these injuries. The damage is not repaired or poorly repaired leading to increased susceptibility to oncogenic transformation since most important biological effects caused by ionizing radiation are mutation and carcinogenesis. The DNA lesions caused by radiation can also provoke the presence of micronuclei and as result cells can be induced to apoptosis. The aim of this work is to perform a preliminary study "in vitro" to identify the presence of micronuclei caused by low energy. X-rays. It is intended analyze these biological effects caused by x-rays with energy equivalent to the ones used in mammography in two very well established breast: cell lines the MCF-7 (tumor) and HB-2 (non-tumor). Cells in exponential growth were irradiated using an experimental arrangement with a mammography tube of the LCR / UERJ. The dose of 5Gy was used for 30 kVp x-rays using 0.03 mm filter molybdenum with a fixed dose rate of 0.1 Gy / sec. The irradiations were repeated twice and. the cells were incubated for 4, 24 or 48 hours and stained with dye Hoechst 33258 for fluorescence microscopy analysis. For each analysis 1000 cells were categorized by the morphology of the nucleus. The results revealed that the HB-2, used in this study as normal mammary cell have showed high sensitivity to the effects of radiation, with 37% of cells undergoing apoptosis after incubation of 4hs, while MCF-7 showed 6.5%. In the 24 hour-analysis it was confirmed the radiation resistance of MCF-7 were it was observed 11% of cells in apoptosis in the irradiated group. There was an increasing number of radiation-induced micronuclei in both cell lines, according to the incubation times. After 4 hours, HB-2 presented 3% of micronuclei, in 24 hours, the experiment reveled 8.5%, and after 48 hours it increased to 11.5%. As result of this study we may conclude that the energy used in mammography is capable to cause an increase in incidence of apoptosis and in the production of micronuclei in both cell lines studied
162

Efeitos da radiação ionizante e eventos singulares em circuitos analógicos de baixo e ultra baixo consumo

Fusco, Daniel Alves January 2016 (has links)
Esse trabalho apresenta um estudo sobre os efeitos de radiação em circuitos analógicos de baixa e ultra baixa potência e tensão, identificando as fragilidades destes circuitos (e das respectivas técnicas de projeto) quando aplicados em ambientes radioativos, como, por exemplo, os circuitos em satélites, e em equipamentos de instalações nucleares. Foram realizados estudos de caso, via simulação elétrica utilizando o software HSPICE, considerando os efeitos de degradação elétrica correspondentes a doses de radiação acumulada de até 500krad(Si), além de eventos singulares considerando circuitos de baixa tensão e potência projetados para a tecnologia IBM (GF) de 130nm. Pôde-se observar que o uso de transistores de óxido mais fino, apesar de afetar negativamente o consumo estático, é recomendado para as aplicações estudadas, devido a menor sensibilidade à radiação. Ainda, foi discutido o aumento dos caminhos de fuga de corrente devido ao uso de layout distribuído. Possibilidades e estratégias de mitigação foram discutidas. Por fim, obteve-se um conjunto de sugestões e informações para auxiliar o projetista de circuitos de baixo consumo a obter soluções robustas à radiação. / This work studies the radiation effects in low-power and ultra-low power analog circuits, identifying the fragility of such circuits (and associated design techniques) when employed in radioactive environments, as for example, in satellites and nuclear facilities. Case studies were carried out using HSPICE software for electrical simulation of cumulative radiation effects, corresponding to doses up to 500krad(Si), as well as for single events simulation. We showed that, the use of thin oxide (core) MOSFETS, though increasing the static consumption, is recommended for the studied applications, because they are less sensitive to radiation. Then, we discussed the increase of current leakage paths by the distributed layout style. Mitigation strategies were also discussed. Finally, we obtained a set of suggestions and information to guide the designers of low power analog circuits towards obtaining radiation robust solutions.
163

Estudo de propriedades dosimétricas utilizando polímero organometálico em solução /

Fernandes, David Moreira. January 2012 (has links)
Orientador: Carlos Frederico de Oliveira Graeff / Coorientador: Erika Soares Bronze-Uhle / Banca: Francisco Eduardo Gontijo Guimarães / Banca: Marco Antonio Rodrigues Fernandes / O Programa de Pós Graduação em Ciência e Tecnologia de Materiais, PosMat, tem carater institucional e integra as atividades de pesquisa em materiais de diversos campi / Resumo: Este trabalho teve como objetivo estudar as características dosimétricas do polímero "poly-[1,1-bis(ethynyl)-4,4-bipheny(bis-tributylphosphine)Pt(11)]" (Pt-DEBP) frente à radiação gama. Para realização dos experimentos dissolveu-se o polímero Pt-DEBP, contendo dez unidades monoméricas, em solventes orgânicos - clorofórmio e totueno. As amostras foram irradiadas em quatro concentrações (0,0500; 0,0375; 0,0250; 0,0113 mg/mL) e em duplicatas, com doses que variaram de 1 a 90 Gy. Os resultados foram avaliados com base em técnicas espectroscópias, como a espectroscopia de absorção óptica (UV-VIs), fluorescência (emissão), fluorescência com resolução temporal (FRT) e infravermelho com transformada de Fourier (FTIR). Para soluções de Pt-DEBP em clorofórmio, nota-se uma alteração na posição da banca principal (л-л *) de absorção óptica para menores comprimentos de onda (blue-shift), aliado a uma diminuição da intensidade de absorção, á medida em que se aumenta a dose de radiação. Na espectroscopia de fluorescência, observou-se um deslocamento para maiores comprimentos de onda (red-shift) aliado a um aumento de intensidade na banda de emissão com aumento da dose de radiação. Experimentos de FRT, das amostras irradiadas em clorofórmio indicam a presença de um novo centro emissor. Os espectros de infravermelho com transformada de Fourier (FTIR) comprovam a entrada de cloro na cadeia polimérica, justificando o blue-shift obervado nos espectros de absorção e o novo centro emissor responsável pela alteração nos espectros de emissão. Além disso, foi analisado o comportamento linear dos resultados obtidos nos estudos de absorção e fluorescência, tomando como base a relação entre comprimento de onda máxima de absorção com a dose e, para o segundo caso, a relação entre... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work aimed to study the dosimetric characteristics of the polymer of the polymer"poly-[1,1-bis (ethynyl) -4,4 biphenyl (bis-tributylphosphine) Pt (II)]" (Pt-DEBP) compared to radiation gamma. The Pt-DEBP polymer, containing ten monomer units, was then dissolved in organic solvents as chloroform and toluene. The samples were irradiated at four concentrations (0.0500, 0.250, 0.0113 mg / mL) in duplicate, with radiation doses ranging from 1 to 90 Gy. The results were evaluated based on spectroscopic techniques such as optical absorption spectroscopy (UV-Vis), fluorescence (emission), time resolved fluorescence (FRT) and Fourier transform infrared (FTIR). For DEBP-Pt solutions in chloroform, there is a shift in the position of the main optical absorption band (л-л *) to lower wavelength (blue-shift), allied to a decreasing absorption intensify with increasing radiation dose. In fluorescence spectroscopy, there was a shift to longer wavelengths (red-shift) allied to an increasing emission intensify with increasing radition dose. FRT experiments on irradiated samples dissolved in chloroform indicated the presence of a new emitter center. FTRI spectra show the incorporation of chlorine in polymer chain, justifying the blue-shift observed in the absorption spectra and the new emission center. In addition, the behavior of linear results in the aborption and fluorescence studies was investigated based on the relationship between the wavelength of maximum absorption/emission and the radiation dose. For both cases, a linear behavior was observed in relation to the sample concentration. Repeatability and stability tests were also performed. For the samples dissolved in tolluene, there was no significant shift of the spectrum of absorption or fluorescence for all doses. The results show that the Pt-DEBP polymer dissolved in chloroform can be used as a dosimer for y-ray doses between... (Complete abstract click electronic access below) / Mestre
164

Efeitos da radiação ionizante e eventos singulares em circuitos analógicos de baixo e ultra baixo consumo

Fusco, Daniel Alves January 2016 (has links)
Esse trabalho apresenta um estudo sobre os efeitos de radiação em circuitos analógicos de baixa e ultra baixa potência e tensão, identificando as fragilidades destes circuitos (e das respectivas técnicas de projeto) quando aplicados em ambientes radioativos, como, por exemplo, os circuitos em satélites, e em equipamentos de instalações nucleares. Foram realizados estudos de caso, via simulação elétrica utilizando o software HSPICE, considerando os efeitos de degradação elétrica correspondentes a doses de radiação acumulada de até 500krad(Si), além de eventos singulares considerando circuitos de baixa tensão e potência projetados para a tecnologia IBM (GF) de 130nm. Pôde-se observar que o uso de transistores de óxido mais fino, apesar de afetar negativamente o consumo estático, é recomendado para as aplicações estudadas, devido a menor sensibilidade à radiação. Ainda, foi discutido o aumento dos caminhos de fuga de corrente devido ao uso de layout distribuído. Possibilidades e estratégias de mitigação foram discutidas. Por fim, obteve-se um conjunto de sugestões e informações para auxiliar o projetista de circuitos de baixo consumo a obter soluções robustas à radiação. / This work studies the radiation effects in low-power and ultra-low power analog circuits, identifying the fragility of such circuits (and associated design techniques) when employed in radioactive environments, as for example, in satellites and nuclear facilities. Case studies were carried out using HSPICE software for electrical simulation of cumulative radiation effects, corresponding to doses up to 500krad(Si), as well as for single events simulation. We showed that, the use of thin oxide (core) MOSFETS, though increasing the static consumption, is recommended for the studied applications, because they are less sensitive to radiation. Then, we discussed the increase of current leakage paths by the distributed layout style. Mitigation strategies were also discussed. Finally, we obtained a set of suggestions and information to guide the designers of low power analog circuits towards obtaining radiation robust solutions.
165

Možná rizika zneužívání radioaktivních materiálů z bývalé úpravny uranových rud MAPE Mydlovary / Possible risks of abuse of radioactive materials from the former uranium ore processing plant MAPE Mydlovary.

ŘEPA, Libor January 2012 (has links)
Possible risks of using radioactive materials are a highly discussed topic nowadays. This work is dealing with this problem and it is focused on possible risks of using radioactive materials from the ex-treatment plant of uranium ores MAPE Mydlovary. In introductory chapters I am describing the current state of ex-treatment plant of uranium ores. I am dealing with the history of operation of MAPE, information about sludge lagoons and about stored sediments in them and other characteristics concerning this operation. For years, sediments in which radionuclides are contained have been stored in treatment plants and that is why I am dealing with ionizing radiation. Because the topic is the using of radioactive materials which can be used mainly by terrorists, I am also describing this worldwide phenomenon of recent years where I first of all focused on super-terrorism using radioactive weapons, namely so-called ?dirty bombs?. The target of this work is to find out possibilities of using radioactive materials from the ex-treatment plant. Therefore I measured values of radioactivity and exposition of radiation at some places with the help of exploratory research. That meant sampling of soils and water and also measurement of power of dose equivalent of radiation gamma. After gathering information of needed radiation values I carried out simulation of possible using of radioactive materials from the premises MAPE. By means of dirty bomb I used the programme TerEx at using radioactive material. Then I carried out several calculations which were focused on inhalation, ingestion or outdoor radiation from radioactive materials and also calculation how much it is necessary to gain a significant source of ionizing radiation. From these sources I have deduced impacts for individuals, society or environment. Based on analysis and evaluation of given problems, my set hypothesis ?By using radioactive materials from the ex-treatment plant of uranium ores MAPE Mydlovary a serious threat to people will not occur? was confirmed. Results of my work can be used as a study material for completing and broadening knowledge about risks resulting from using radioactive materials. Further an increase of foreknowledge and explanation of certain consequences of ionizing radiation on humans from materials from the ex-treatment plant of uranium ores MAPE Mydlovary, for inhabitants of Mydlovary and surrounding areas and also useful information for lay and professional society which is interested in these problems.
166

Exposição à radiação ionizante dos profissionais de saúde em hemodinâmica: o enfoque da enfermagem / Exposure of health professionals to ionizing radiation at hemodynamic: the nursing's vision

Katia Maria dos Santos Calegaro 18 December 2007 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / As radiações ionizantes têm sido cada vez mais usadas na medicina contemporânea, inserida em contextos diagnósticos e terapêuticos. O objeto deste estudo foi, portanto, a exposição à radiação ionizante relacionada ao processo de trabalho dos profissionais de saúde em hemodinâmica e seus objetivos foram conhecer o perfil dos trabalhadores de saúde que atuam no setor de hemodinâmica, levantar os problemas de saúde provocados ou agravados pelo trabalho a partir da ótica do profissional, conhecer as doses ocupacionais dos trabalhadores, correlacionando os dados encontrados à luz da legislação específica vigente. Tratou-se de um estudo exploratório e descritivo com abordagem quanti-qualitativa que teve como instrumentos de coleta de dados: a observação sistemática do local de estudo, lê-se, o setor de hemodinâmica de um hospital universitário localizado na cidade do Rio de Janeiro; a aplicação de um questionário com 35 perguntas abertas e fechadas aos sujeitos do estudo, lê-se, os profissionais de saúde médicos, enfermeiros, técnicos de enfermagem e técnicos de radiologia que atuavam no setor de hemodinâmica; e a busca documental pelas doses ocupacionais retrospectivas dos trabalhadores. Como resultados, identificou-se uma população com média de 39 anos, com experiência profissional média, em saúde e hemodinâmica, de 10 anos, que trabalham em mais de uma instituição de saúde expostos à radiação ionizante. Foram discutidas questões relativas à saúde, segurança, formação e prática profissional dos sujeitos à luz das legislações que versam sobre o uso de radiações ionizantes. Concluiu-se a necessidade de adaptações e mudanças em diversas esferas / setores objetivando a otimização da radioproteção, da saúde dos trabalhadores e da prática em hemodinâmica. / Ionizing radiations have been used in the contemporary medicine, inserted in disgnostic and therapeutical contexts. Therefore, the object of this study was the relation among ionizing radiation exposition and the work process of the health professionals at hemodynamic; the objectives were: know the profile of the professionals working at hemodynamic unit, identify health problems caused or aggravated by work on the workers agreement, know the occupational dosis of this professionals and correlate data with the specific current law. This is a descriptive study, quanti-qualitative that had like data collection instruments: a systematic observation of an hemodynamic unit located in an university hospital in Rio de Janeiro; application of a questionnaire with 35 open and closed questions to population healths professionals: physicians, nurses, radiology technicians and nursing technicians - that works at hemodynamics, and a documentary search about their last occupational dosis. The results of this study shows a population with average age of 39 years, with a lot of professional experience, in health and hemodynamic (10 years in average), that work at more than one health institution exposed to ionizing radiation. Questions about health, security, graduation and professional practice had been analyzed and argued based in the specific legislation. The conclusions are a necessity of adaptations and changes in diverse sectors objectifying the optimization of radioprotection, workers health and the practice at hemodynamics units.
167

Efeitos de raios-X de baixa energia em células mamárias / Effects of low energy x-rays in mammary cells

Flávia Ventura dos Passos 12 August 2011 (has links)
Doses de radiação de baixa energia podem induzir quebras de dupla fita no DNA assim como também produzir perfis alterados de expressão de genes relacionados a estas lesões. Os danos não reparados ou mal reparados levam a uma maior suscetibilidade à transformação oncogênica já que os efeitos biológicos mais importantes causados pela radiação ionizante são mutação e carcinogênese. As lesões no DNA provocadas pela radiação podem também ocasionar o surgimento micronúcleos e as células podem ser induzidas à apoptose. O objetivo deste trabalho é estudar in vitro a presença de micronúcleos e a apoptose ocasionados por Raios-X de baixa energia. Pretende-se analisar estes efeitos biológicos em relação à energia equivalente à utilizada em exames mamográficos usando duas linhagens estabelecias de células de mama: a MCF-7 (tumoral) e a HB-2 (não-tumoral). As células, em crescimento exponencial, foram irradiadas no equipamento de arranjo experimental de mamografia do LCR/UERJ. A dose de 5Gy na energia de 30 kV foi aplicada com taxa de 0,1 Gy/seg utilizando filtro de 0,03 mm de molibdênio. As irradiações foram realizadas duas vezes, após as irradiações, as células foram incubadas por 4, 24 ou 48 horas e posteriormente coradas com o corante Hoechst33258 para análise em microscopia de fluorescência. Para cada análise, 1000 células foram categorizadas pela morfologia do núcleo. Os resultados mostraram que a HB-2, utilizada neste estudo como célula mamária normal, apresentou maior sensibilidade aos efeitos da radiação, com 37 % das células em apoptose após 4 hs de incubação, enquanto a MCF-7 apresentou 6,5 %. Nas análises após 24 hs foi possível confirmar a radioresistência da MCF-7 tendo sido observadas 11% de células em apoptose no grupo irradiado. Houve um aumento crescente de micronúcleos radioinduzidos nas duas linhagens de acordo com os tempos de incubação. Na análise de 4 hs a HB-2 apresentou 3%, em 24 hs, 8,5% e 48 hs, 11,5 %. Diante destes resultados, foi possível concluir que a energia do feixe de raios-X utilizada na mamografia pode ser capaz de ocasionar aumento de ocorrência de apoptose e geração de micronúcleos nas duas linhagens estudadas / Radiation doses of low-energy can induce double-stranded breaks in DNA as well resulting in altered profiles of gene expression related to these injuries. The damage is not repaired or poorly repaired leading to increased susceptibility to oncogenic transformation since most important biological effects caused by ionizing radiation are mutation and carcinogenesis. The DNA lesions caused by radiation can also provoke the presence of micronuclei and as result cells can be induced to apoptosis. The aim of this work is to perform a preliminary study "in vitro" to identify the presence of micronuclei caused by low energy. X-rays. It is intended analyze these biological effects caused by x-rays with energy equivalent to the ones used in mammography in two very well established breast: cell lines the MCF-7 (tumor) and HB-2 (non-tumor). Cells in exponential growth were irradiated using an experimental arrangement with a mammography tube of the LCR / UERJ. The dose of 5Gy was used for 30 kVp x-rays using 0.03 mm filter molybdenum with a fixed dose rate of 0.1 Gy / sec. The irradiations were repeated twice and. the cells were incubated for 4, 24 or 48 hours and stained with dye Hoechst 33258 for fluorescence microscopy analysis. For each analysis 1000 cells were categorized by the morphology of the nucleus. The results revealed that the HB-2, used in this study as normal mammary cell have showed high sensitivity to the effects of radiation, with 37% of cells undergoing apoptosis after incubation of 4hs, while MCF-7 showed 6.5%. In the 24 hour-analysis it was confirmed the radiation resistance of MCF-7 were it was observed 11% of cells in apoptosis in the irradiated group. There was an increasing number of radiation-induced micronuclei in both cell lines, according to the incubation times. After 4 hours, HB-2 presented 3% of micronuclei, in 24 hours, the experiment reveled 8.5%, and after 48 hours it increased to 11.5%. As result of this study we may conclude that the energy used in mammography is capable to cause an increase in incidence of apoptosis and in the production of micronuclei in both cell lines studied
168

Použití přenosného spektrometru pro detekci radionuklidů v přepravovaných materiálech / Radionuclide detection in transported materials by a portable spectrometer.

PLAŇANSKÝ, Jiří January 2018 (has links)
The aim of my diploma thesis was to assess possibilities of tracing and, consequently, identifying radionuclides in transported materials detected by detection frames on the protected area border of the nuclear power plant of Temelín, by means of the portable spectrometer Inspector 1000. To achieve this, I designed a series of measurements based on a simulated passage of a motor vehicle fitted with ionizining radiation sources of various activities at the designed points of measurement so that these measurements corresponded as close as possible to the actual passage of vehicles with large-sized loads. Recorded values were analysed and marginal activities for the particular measuring points were fixed. Computation correctness was then verified by another passage of the vehicle through the measuring device. Specified values of the marginal activities at the particular measuring points were, for comparison, consequently measured by the portable spectrometer Inspector 1000. Measurement results proved that the portable spectrometer Inspector 1000 can efficiently detect, identify and locate the sources of ionizing radiation causing the alarm level to be exceeded on a stable measuring device at the fixed measuring points, with a higher sensitivity than a stable measuring device. Conclusions of this diploma thesis will be given to the radiation protection unit of the nuclear power plant of Temelín as a basis for specification or even expansion of the methods of measuring ionizining radiation sources when transporting large-sized loads in the nuclear power plant, and their introduction into the monitoring programme.
169

Radiologický terorismus / Radiological terrorism

DRAŽANOVÁ, Kristýna January 2018 (has links)
This diploma thesis deals with the analysis of preparedness of the Czech Republic for terrorist attack using radioactive material or source of ionizing radiation. The theoretical part of the thesis presents a basic introduction to the issue of terrorism, with a special emphasis on chemical, biological, radiological and nuclear terrorism, it describes the individual types of radiological weapons and represents the categorization of sources of ionizing radiation according to the International Atomic Energy Agency, together with radionuclides identified as potentially risky for terrorist abuse. The analysis in the research part was divided into several parts. It focuses independently on documentation that is being prepared in this area, on the exercise of the crisis management bodies and integrated rescue system units, which took place in several regions of Czech Republic, and on events related to the unauthorized use of radioactive material or sources of ionizing radiation. The last part of the research part is interviews with experts working in the field of preparedness of the Czech Republic for the risk of radiological terrorism. The purpose of the thesis was to collect information on how the Czech Republic is preparing for the risk of radiological terrorism and their subsequent evaluation through qualitative analysis. The results of this analysis show that Czech Republic is preparing for the risk of radiological terrorism in a way, that corresponds to the real risk. Conceptual and methodical materials are being elaborated in the subject area and exercises are carried out, which are attended both by the crisis management bodies and the integrated rescue system component. The technical and material equipment necessary for dealing with extraordinary event, that would arise due to radiological terrorism, is at perfect level. However, greater attention could be paid to the risk of abuse of the sources of ionizing radiation in the form of a radiological weapon of the RED kind (hidden emitter).
170

Análise comparativa de exposição do operador à radiação entre as técnicas radial, femoral e radial com dispositivo protetor em procedimentos de cardiologia intervencionista / Comparative analysis of operator exposure to radiation among the radial, femoral and radial with protective device techniques in interventional cardiology procedures

Bienert, Igor Ribeiro de Castro [UNESP] 26 January 2016 (has links)
Submitted by IGOR RIBEIRO DE CASTRO BIENERT (bienert@terra.com.br) on 2016-01-29T14:19:19Z No. of bitstreams: 2 Tese Igor R C Bienert versao final para arquivamento.pdf: 2600270 bytes, checksum: 99be667aca0d1c9255e8b1f9002d9a85 (MD5) Bienert_et_al BMJ Innovations.pdf: 1803372 bytes, checksum: 31c4180b21a1482a1a0afcc7856c9b78 (MD5) / Rejected by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: Foram submetidos 2 arquivos PDF’s, apenas 1 arquivo deve ser submetido (o que contém a Tese ou Dissertação) Corrija estas informações e realize uma nova submissão contendo o arquivo correto. Agradecemos a compreensão. on 2016-02-02T12:39:46Z (GMT) / Submitted by IGOR RIBEIRO DE CASTRO BIENERT (bienert@terra.com.br) on 2016-02-19T20:50:56Z No. of bitstreams: 2 Tese Igor R C Bienert versao final para arquivamento.pdf: 2600270 bytes, checksum: 99be667aca0d1c9255e8b1f9002d9a85 (MD5) Bienert_et_al BMJ Innovations.pdf: 1803372 bytes, checksum: 31c4180b21a1482a1a0afcc7856c9b78 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-02-23T13:21:58Z (GMT) No. of bitstreams: 1 bienert_irc_dr_bot.pdf: 2600270 bytes, checksum: 99be667aca0d1c9255e8b1f9002d9a85 (MD5) / Made available in DSpace on 2016-02-23T13:21:58Z (GMT). No. of bitstreams: 1 bienert_irc_dr_bot.pdf: 2600270 bytes, checksum: 99be667aca0d1c9255e8b1f9002d9a85 (MD5) Previous issue date: 2016-01-26 / Introdução: A cardiologia intervencionista requer necessariamente um acesso vascular invasivo, sendo esta via de acesso uma escolha do médico operador. Nesta escolha interfere o tipo de procedimento, impacto ao paciente, risco ao profissional e experiência técnica. O acesso via artéria femoral é o mais difundido globalmente e a técnica de acesso pela artéria radial tem sido progressivamente adotada devido ao maior conforto para o paciente, menores taxas de complicações e em alguns cenários, de mortalidade. Um dos focos de interesse crescente é a exposição à radiação ionizante e medidas para minimizar o risco ao paciente e ao profissional. Escassa é a literatura disponível na área e conflitantes são seus resultados. Objetivo: Avaliar os níveis de radiação recebidos pelo médico operador de acordo com as diferentes técnicas de acesso, bem como mapear áreas de escape de radiação. Após essa etapa, o estudo visou desenvolver e validar dispositivo de radioproteção dedicado à técnica radial (TRIPTable) voltado à redução da radiação ao médico operador, comparando o seu impacto à técnica femoral e radial padrão no cenário de pacientes portadores de síndrome coronária aguda randomicamente alocados para cateterismo com intenção de tratamento percutâneo. Métodos: A fase inicial pré-clínica do estudo foi constituída de avaliação em ambiente controlado dos níveis de radiação em pontos pré-especificados de um operador simulado com phantom de água. A fase clínica do estudo foi um ensaio clínico prospectivo, randomizado, unicêntrico, comparativo entre três grupos denominados técnica femoral, técnica radial e técnica radial com dispositivo radioprotetor TRIPTable, recrutados no Hospital das Clínicas de Marília (Marília/SP) e randomizados na proporção 1:1:1 (108 pacientes - 36 por grupo) avaliando a radiação recebida pelo operador em três diferentes pontos (gônadas, tireoide e olhos). Os resultados foram comparados com o grupo controle de 108 pacientes provenientes de coorte randomizada externa entre técnica radial e femoral 1:1, utilizando critérios similares, porém com operadores cegos aos objetivos de avaliação de radiação visando detecção de vieses de técnica (efeito Hawthorne) e validação de resultados. Resultados: Não houve diferença entre o estudo e a coorte externa ou entre os grupos do estudo quanto a características clínicas, desfechos dos procedimentos ou parâmetros de exposição radiológica ao paciente. Os resultados indicam maior radiação recebida pelo operador com a técnica radial (12,5 mSv), seguida da femoral (10,1 mSv) e TRIPTable (6,8 mSv). Em relação aos locais de exposição, o território de gônadas teve maior sensibilidade radiológica com uso da técnica radial (p=0,001). Com uso da técnica femoral não houve diferença entre os três territórios (p=0,398), porém na análise ad hoc o território de gônadas foi mais sensível quando comparado à exposição aos olhos (p=0,016) e limítrofe em comparação à tireoide (p=0,056). No grupo do dispositivo TRIPTable não houve diferença significativa entre qualquer um dos territórios analisados (p=0,180). Conclusões: O estudo indica equivalência entre os resultados do procedimento entre os grupos e quanto à exposição radiológica ao paciente. Contudo, demonstrou maior impacto radiológico para o operador que utilizou a técnica radial, em comparação à técnica femoral e à técnica radial com uso do dispositivo TRIPTable. O uso do dispositivo reduziu o impacto radiológico comparado ainda à técnica femoral. Tais diferenças derivaram primordialmente da variação em território de gônadas. Os achados demonstram um campo de exposição radiológica heterogêneo ao corpo do operador, benefício do dispositivo testado e oportunidade de novas formas de desenvolvimento de medidas de radioproteção. Registros: UTN/OMS - U1111-1158-8591 Plataforma Brasil - CAAE 32767514.0.1001.5413 Clinical Trials - NCT 02200783. / Background: Interventional cardiology requires an invasive vascular access, a choice of medical operator. This choice is affected by type of procedure, patient impact, professional risk and technical experience. Interventional procedures via radial technique have progressively increased due to improved patient comfort, lower complication rates, and reduced mortality in some scenarios. One area of interest is radiation exposure and ways to minimizing it. Most studies focusing on patient radiation risk demonstrated conflicting results, and there is no consensus for increased exposure with any technique. Objective: The aim of this study was to evaluate radiological exposure under controlled radial and femoral access simulation tests, mapping radiation paths. After this stage, the study developed a radiological protection device for the transradial technique (TRIPTable), comparing its impact as compared to standard femoral and radial techniques in the setting of patients with acute coronary syndrome randomly assigned for catheterization with intent to percutaneous treatment. Methods: Radiation exposure was simulated under controlled conditions for femoral and radial techniques using a pressurized ionization chamber and water phantom. Different measurement points were defined according to standard positions to simulate radiation received by the operator in the gonads, thyroid, and eyes at different angles during real procedures. The clinical phase of the study is a prospective clinical trial, single-center, randomized, and comparing three groups (femoral technique, radial technique, and radial technique with radioprotective device), admitted in the Emergency Department of Hospital das Clinicas de Marilia (Marilia / SP – Brazil). Patients were randomized in a 1:1:1 proportion (108 patients - 36 per group) evaluating the radiation received by the operator measured by dosimetry at three different points (gonads, thyroid and eyes). As it is impossible to blind operators to study techniques, the results were compared to an external control cohort of patients including 108 individuals with similar inclusion and exclusion criteria, randomized for radial and femoral technique, but with blinded operators to radiation objectives, aiming technical bias detection (Hawthorne effect) and validation of results. Results: There was no difference between groups regarding clinical characteristics, procedures or patient radiation exposure outcomes. The results indicate higher radiation received by the operator with the radial technique (12.5 mSv) as compared to femoral technique (10.1 mSv) and TRIPTable technique (6.8 mSv). Regarding exposure locations, the gonad region had a higher radiation sensitivity with radial technique (p=0.001). With femoral technique there was no difference between the three territories (p=0.398) but the ad hoc analysis indicated higher radiosensibility in gonads when compared to eyes exposure (p=0.016) and borderline compared to thyroid exposure (p=0.056). In the TRIPTable device group there was no significant difference between any of the territories analyzed (p=0.180). Conclusions: The study indicates no difference of radiation exposure to the patients between the groups. However, there was a greater radiologic impact to the operator who used the radial technique, compared to the femoral technique and TRIPTable device technique. The device reduced the radiological impact even compared to the femoral technique. Such differences derived primarily from variation in gonads exposure. The findings demonstrate a heterogeneous radiation exposure to the operator body, device benefit and an opportunity to develop new ways to improve radiation protection. Registration: UTN/OMS - U1111-1158-8591 Plataforma Brasil - CAAE 32767514.0.1001.5413 Clinical Trials - NCT 02200783.

Page generated in 0.0468 seconds