191

Técnicas de redução de potência estática em memórias CMOS SRAM e aplicação da associação de MOSFETs tipo TST em nano-CMOS / Static energy reduction techniques for CMOS SRAM memories and TST MOSFET association application for nano-CMOS

Conrad Junior, Eduardo January 2009 (has links)
Em nossos dias a crescente busca por portabilidade e desempenho resulta em esforços focados na maximização da duração de bateria dos equipamentos em fabricação, ou seja, busca-se a conflitante solução de circuitos com baixo consumo e ao mesmo tempo com alto desempenho. Neste contexto usualmente na composição de equipamentos portáteis empregam-se SOC´s (Systems On Chip) o que barateia o custo de produção e integração destes circuitos. SOC´s são sistemas completos que executam uma determinada função integrados em uma pastilha de silício única, normalmente possuem memórias SRAM como componente do sistema, que são utilizadas como memórias de alta performance e baixa latência e/ou também como caches. O grande desafio de projeto em memórias SRAMS é a relação de desempenho versus potência consumida a ser otimizada. Basicamente por sua construção estes circuitos apresentam alto consumo de potência, dinâmica e estática, relacionada a primeira diretamente ao aumento de freqüência de operação. Um dos focos desta dissertação é explorar soluções para a redução de consumo de energia tanto dinâmica como estática, sendo a redução de consumo estático de células de memória em standby buscando desempenho, estabilidade e baixo consumo de energia. No desenvolvimento de técnicas para projeto de circuitos analógicos em tecnologias nanométricas, os TST´s (T-Shaped Transistors – Transistor tipo T) surgem como dispositivos com características potenciais para projeto analógico de baixa potência. TSTs / TATs (Trapezoidal Associations of Transistors – Associação Trapezoidal de transistores) são estruturas self-cascode que podem tornar-se uma boa escolha por apresentar redução do leakage, redução na área utilizada e com incremento na regularidade do layout e no casamento entre transistores, propriedade importantíssima para circuitos analógicos. Sendo este o segundo foco deste texto através do estudo e análise das medidas elétricas dos TSTs executadas para comprovação das características destes dispositivos. Também apresenta-se uma análise das possibilidades de utilização dos TSTs em projeto analógico para tecnologias nanométricas. / Nowadays the increasing needs for portability and performance has resulted in efforts to increase battery life, i. e., the conflicting demands for low power consumption and high performance circuits. In this context using SOC´s (System On Chip) in the development for portable equipments composition, an integration of an entire system for a given function in a single silicon die will provide less production costs and less integration costs. SOC´s normally include a SRAM memory as its building block and are used to achieve memories with low latency and short access time or (and) as caches. A performance versus power consumption analysis of SRAM memory building blocks shows a great challenge to be solved. The electrical design aspects of these blocks reveal high power consumption, dynamic and static, and the former is directly proportional to the operating frequency. The design space exploration for dynamic and leakage consumption reduction in these circuits is one of the focus of this work. The main contribution of this topic is the leakage reduction techniques based in performance, stability and low energy consumption for the memory cell stand-by mode. Among the electrical techniques developed for analog circuits at the 20-100 nanometer scale, the TST (T-Shaped Transistors) rises with potential characteristics for analog low power design. TST /TAT (Trapezoidal Associations of Transistors) are selfcascode structures and can be turning into a good alternative for leakage and area reduction. Another point is the increment in mismatch and layout regularity, all these characteristics being very important in analog designs. The TST electrical measurements study and analysis are developed to show the device properties. An analysis of the TST desired properties and extrapolation for nanometer technologies analog design are also presented.
192

Avaliação da capacidade de selamento de três materiais obturadores em canais radiculares de pré-molares de cães preparados para pino intra-radicular expostos ao meio bucal

Kopper, Patrícia Maria Poli January 2008 (has links)
O presente estudo teve como objetivo avaliar in vivo a capacidade de selamento de três materiais obturadores constituídos de cimentos endodônticos resinosos, sendo dois (AH Plus e EndoRez) associados a cones de guta-percha, e um (Real Seal) a cones de Resilon, em pré-molares de cães, expostos ao meio bucal, após o preparo para colocação de pino protético. Objetivou, também, avaliar a correlação entre a situação inflamatória dos tecidos periapicais e a infiltração microbiana. Para tal, foi realizado o preparo químico-mecânico de 80 dentes (160 canais), sendo dez (20 canais) em cada cão. Antes da obturação, os canais foram distribuídos, aleatoriamente, em sete grupos. Nos grupos I – GI (n=32) e controle negativo I – C-I (n=16), os canais foram obturados com cones de guta-percha e AH Plus; nos grupos II – GII (n=32) e controle negativo II – C-II (n=16), com cones de guta-percha e EndoRez; e nos grupos III – GIII (n=32) e controle negativo III – C-III (n=16), com cones de Resilon e Real Seal. Os canais do grupo controle positivo – C+ (n=16) não foram obturados. Imediatamente após a obturação, realizou-se a desobturação parcial dos canais, restando 4 mm de material na região apical. Os dentes foram selados, provisoriamente, com amálgama de prata, durante 72 horas. Após esse período, o selamento coronário de todos os canais, com exceção dos pertencentes aos grupos C-, foi removido, ficando expostos ao meio bucal por 90 dias. Os animais foram mortos, e as mandíbulas e maxilas removidas e seccionadas, separando-se o lado esquerdo do direito. Nos dentes das hemi-arcadas do lado esquerdo, o selamento dos canais dos grupos C- foi removido e o espaço protético irrigado, abundantemente, com água destilada. Após, foram secos e preenchidos com tinta nanquim. Os dentes foram, novamente, selados e, passadas 96 horas, extraídos. A seguir, as raízes foram separadas, armazenadas em tubos de ensaio e diafanizadas. Os espécimes do lado direito foram processados histologicamente, empregando-se as colorações de Hematoxilina e Eosina de Harris (HE) e Brown e Brenn (BB). A infiltração de corante foi medida com auxílio de lupa esteroscópica, com aumento de 10x. A análise dos cortes histológicos foi realizada em microscópio óptico, classificando-se o estado inflamatório dos tecidos periapicais e a infiltração microbiana em escores de 1 a 4. Os resultados da infiltração de corante evidenciaram que todos os grupos apresentaram menor infiltração que o grupo C+ (p<0,001) e que os grupos GI, GII e GIII não diferiram significativamente (P>0,05). O grupo GII apresentou diferenças significativas em relação ao seu grupo controle negativo, mostrando maior infiltração de corante (P<0,001). Na análise histológica, todos os materiais testados apresentaram menor grau de reação inflamatória e de infiltração microbiana, quando comparados com o grupo C+ (P≤0,001). Além disso, não foram observadas diferenças significativas entre os grupos GI, GII e GIII, bem como destes com seus respectivos controles (P>0,05). O teste de correlação de Spearman mostrou uma forte correlação entre resposta inflamatória e infiltração microbiana (rs= 0,57; P<0,001). A partir do exposto, concluiu-se que os materiais testados não apresentaram diferenças significativas entre si e que a resposta inflamatória periapical apresentou correlação direta com a infiltração coronária microbiana. / The aim of this study was to assess in vivo the sealing ability of three resin-containing endodontic sealers, two associated with gutta-percha points (AH Plus and EndoRez) and one associated with Resilon points (RealSeal). Mongrel dogs had their premolars prepared and filled, then post-prepared, which space became exposed to the oral environment. The correlation between inflammatory condition and level of microbial leakage was also tested. For that purpose, 80 teeth (160 root canals), being 10 (20 root canals), for each dog, were chemo-mechanically prepared and randomly divided into the following groups: GI (n=32) and C-I (negative control; n=16): root filling with gutta-percha and AH-Plus; GII (n=32) and C-II (n=16): root filling with gutta-percha and Endorez; GIII (n=32) and C-III (n=16): root filling with Resilon and RealSeal; C+ (positive control; n=16): no root filling. Immediately following filling procedures, post space preparation was done leaving 4mm of filling material apically. Teeth had their crowns provisionally sealed with amalgam for 72 hours. Then, coronal seal was removed (except for C-) and remained exposed to the oral environment for 90 days. The dogs were sacrificed and their mandible and maxilla were removed and sectioned, separating right and left sides. In the specimens from the left side, the C- teeth had their seal removed, and all teeth had their post space irrigated with distilled water, then filled with India ink. Following 96 hours, the teeth were extracted. Roots were labeled as to the groups and subjected to clearing process in test tubes. The specimens from the right side were histologically processed and stained with Hematoxicilin and Eosin (HE) and Brown and Brenn (BB). The ink leakage was measured three dimensionally under stereoscope microscopy (10x). Histological sections were assessed under light microscopy by a senior observer blinded as to the groups and the inflammatory state was classified using scores varying from 1 to 4 in an ascending severity. The same severity scoring applied to the microbial leakage, being the severity scored as to the depth of microbial penetration within the dentinal tubules. The results showed that all the test groups displayed less leakage than C+ group (P<0,001). GI, GII and GIII did not differ statistically amongst them. Sealing ability of GII differed significantly to its control group – C-II (P<0,001).Histological analysis showed that all test groups displayed lower inflammatory reaction and microbial leakage when compared to C+ group (P≤0,001). No significant differences were found amongst GI, GII and GIII and their respective controls (p>0,05). Spearman correlation test showed a strong correlation between inflammatory response and microbial leakage (rs= 0,57; P<0,001). It could be concluded that the tested materials did not differ amongst themselves and that the periapical tissue response correlated directly with the microbial coronal leakage.
193

Técnicas de redução de potência estática em memórias CMOS SRAM e aplicação da associação de MOSFETs tipo TST em nano-CMOS / Static energy reduction techniques for CMOS SRAM memories and TST MOSFET association application for nano-CMOS

Conrad Junior, Eduardo January 2009 (has links)
Em nossos dias a crescente busca por portabilidade e desempenho resulta em esforços focados na maximização da duração de bateria dos equipamentos em fabricação, ou seja, busca-se a conflitante solução de circuitos com baixo consumo e ao mesmo tempo com alto desempenho. Neste contexto usualmente na composição de equipamentos portáteis empregam-se SOC´s (Systems On Chip) o que barateia o custo de produção e integração destes circuitos. SOC´s são sistemas completos que executam uma determinada função integrados em uma pastilha de silício única, normalmente possuem memórias SRAM como componente do sistema, que são utilizadas como memórias de alta performance e baixa latência e/ou também como caches. O grande desafio de projeto em memórias SRAMS é a relação de desempenho versus potência consumida a ser otimizada. Basicamente por sua construção estes circuitos apresentam alto consumo de potência, dinâmica e estática, relacionada a primeira diretamente ao aumento de freqüência de operação. Um dos focos desta dissertação é explorar soluções para a redução de consumo de energia tanto dinâmica como estática, sendo a redução de consumo estático de células de memória em standby buscando desempenho, estabilidade e baixo consumo de energia. No desenvolvimento de técnicas para projeto de circuitos analógicos em tecnologias nanométricas, os TST´s (T-Shaped Transistors – Transistor tipo T) surgem como dispositivos com características potenciais para projeto analógico de baixa potência. TSTs / TATs (Trapezoidal Associations of Transistors – Associação Trapezoidal de transistores) são estruturas self-cascode que podem tornar-se uma boa escolha por apresentar redução do leakage, redução na área utilizada e com incremento na regularidade do layout e no casamento entre transistores, propriedade importantíssima para circuitos analógicos. Sendo este o segundo foco deste texto através do estudo e análise das medidas elétricas dos TSTs executadas para comprovação das características destes dispositivos. Também apresenta-se uma análise das possibilidades de utilização dos TSTs em projeto analógico para tecnologias nanométricas. / Nowadays the increasing needs for portability and performance has resulted in efforts to increase battery life, i. e., the conflicting demands for low power consumption and high performance circuits. In this context using SOC´s (System On Chip) in the development for portable equipments composition, an integration of an entire system for a given function in a single silicon die will provide less production costs and less integration costs. SOC´s normally include a SRAM memory as its building block and are used to achieve memories with low latency and short access time or (and) as caches. A performance versus power consumption analysis of SRAM memory building blocks shows a great challenge to be solved. The electrical design aspects of these blocks reveal high power consumption, dynamic and static, and the former is directly proportional to the operating frequency. The design space exploration for dynamic and leakage consumption reduction in these circuits is one of the focus of this work. The main contribution of this topic is the leakage reduction techniques based in performance, stability and low energy consumption for the memory cell stand-by mode. Among the electrical techniques developed for analog circuits at the 20-100 nanometer scale, the TST (T-Shaped Transistors) rises with potential characteristics for analog low power design. TST /TAT (Trapezoidal Associations of Transistors) are selfcascode structures and can be turning into a good alternative for leakage and area reduction. Another point is the increment in mismatch and layout regularity, all these characteristics being very important in analog designs. The TST electrical measurements study and analysis are developed to show the device properties. An analysis of the TST desired properties and extrapolation for nanometer technologies analog design are also presented.
194

Avaliação da capacidade de selamento de três materiais obturadores em canais radiculares de pré-molares de cães preparados para pino intra-radicular expostos ao meio bucal

Kopper, Patrícia Maria Poli January 2008 (has links)
O presente estudo teve como objetivo avaliar in vivo a capacidade de selamento de três materiais obturadores constituídos de cimentos endodônticos resinosos, sendo dois (AH Plus e EndoRez) associados a cones de guta-percha, e um (Real Seal) a cones de Resilon, em pré-molares de cães, expostos ao meio bucal, após o preparo para colocação de pino protético. Objetivou, também, avaliar a correlação entre a situação inflamatória dos tecidos periapicais e a infiltração microbiana. Para tal, foi realizado o preparo químico-mecânico de 80 dentes (160 canais), sendo dez (20 canais) em cada cão. Antes da obturação, os canais foram distribuídos, aleatoriamente, em sete grupos. Nos grupos I – GI (n=32) e controle negativo I – C-I (n=16), os canais foram obturados com cones de guta-percha e AH Plus; nos grupos II – GII (n=32) e controle negativo II – C-II (n=16), com cones de guta-percha e EndoRez; e nos grupos III – GIII (n=32) e controle negativo III – C-III (n=16), com cones de Resilon e Real Seal. Os canais do grupo controle positivo – C+ (n=16) não foram obturados. Imediatamente após a obturação, realizou-se a desobturação parcial dos canais, restando 4 mm de material na região apical. Os dentes foram selados, provisoriamente, com amálgama de prata, durante 72 horas. Após esse período, o selamento coronário de todos os canais, com exceção dos pertencentes aos grupos C-, foi removido, ficando expostos ao meio bucal por 90 dias. Os animais foram mortos, e as mandíbulas e maxilas removidas e seccionadas, separando-se o lado esquerdo do direito. Nos dentes das hemi-arcadas do lado esquerdo, o selamento dos canais dos grupos C- foi removido e o espaço protético irrigado, abundantemente, com água destilada. Após, foram secos e preenchidos com tinta nanquim. Os dentes foram, novamente, selados e, passadas 96 horas, extraídos. A seguir, as raízes foram separadas, armazenadas em tubos de ensaio e diafanizadas. Os espécimes do lado direito foram processados histologicamente, empregando-se as colorações de Hematoxilina e Eosina de Harris (HE) e Brown e Brenn (BB). A infiltração de corante foi medida com auxílio de lupa esteroscópica, com aumento de 10x. A análise dos cortes histológicos foi realizada em microscópio óptico, classificando-se o estado inflamatório dos tecidos periapicais e a infiltração microbiana em escores de 1 a 4. Os resultados da infiltração de corante evidenciaram que todos os grupos apresentaram menor infiltração que o grupo C+ (p<0,001) e que os grupos GI, GII e GIII não diferiram significativamente (P>0,05). O grupo GII apresentou diferenças significativas em relação ao seu grupo controle negativo, mostrando maior infiltração de corante (P<0,001). Na análise histológica, todos os materiais testados apresentaram menor grau de reação inflamatória e de infiltração microbiana, quando comparados com o grupo C+ (P≤0,001). Além disso, não foram observadas diferenças significativas entre os grupos GI, GII e GIII, bem como destes com seus respectivos controles (P>0,05). O teste de correlação de Spearman mostrou uma forte correlação entre resposta inflamatória e infiltração microbiana (rs= 0,57; P<0,001). A partir do exposto, concluiu-se que os materiais testados não apresentaram diferenças significativas entre si e que a resposta inflamatória periapical apresentou correlação direta com a infiltração coronária microbiana. / The aim of this study was to assess in vivo the sealing ability of three resin-containing endodontic sealers, two associated with gutta-percha points (AH Plus and EndoRez) and one associated with Resilon points (RealSeal). Mongrel dogs had their premolars prepared and filled, then post-prepared, which space became exposed to the oral environment. The correlation between inflammatory condition and level of microbial leakage was also tested. For that purpose, 80 teeth (160 root canals), being 10 (20 root canals), for each dog, were chemo-mechanically prepared and randomly divided into the following groups: GI (n=32) and C-I (negative control; n=16): root filling with gutta-percha and AH-Plus; GII (n=32) and C-II (n=16): root filling with gutta-percha and Endorez; GIII (n=32) and C-III (n=16): root filling with Resilon and RealSeal; C+ (positive control; n=16): no root filling. Immediately following filling procedures, post space preparation was done leaving 4mm of filling material apically. Teeth had their crowns provisionally sealed with amalgam for 72 hours. Then, coronal seal was removed (except for C-) and remained exposed to the oral environment for 90 days. The dogs were sacrificed and their mandible and maxilla were removed and sectioned, separating right and left sides. In the specimens from the left side, the C- teeth had their seal removed, and all teeth had their post space irrigated with distilled water, then filled with India ink. Following 96 hours, the teeth were extracted. Roots were labeled as to the groups and subjected to clearing process in test tubes. The specimens from the right side were histologically processed and stained with Hematoxicilin and Eosin (HE) and Brown and Brenn (BB). The ink leakage was measured three dimensionally under stereoscope microscopy (10x). Histological sections were assessed under light microscopy by a senior observer blinded as to the groups and the inflammatory state was classified using scores varying from 1 to 4 in an ascending severity. The same severity scoring applied to the microbial leakage, being the severity scored as to the depth of microbial penetration within the dentinal tubules. The results showed that all the test groups displayed less leakage than C+ group (P<0,001). GI, GII and GIII did not differ statistically amongst them. Sealing ability of GII differed significantly to its control group – C-II (P<0,001).Histological analysis showed that all test groups displayed lower inflammatory reaction and microbial leakage when compared to C+ group (P≤0,001). No significant differences were found amongst GI, GII and GIII and their respective controls (p>0,05). Spearman correlation test showed a strong correlation between inflammatory response and microbial leakage (rs= 0,57; P<0,001). It could be concluded that the tested materials did not differ amongst themselves and that the periapical tissue response correlated directly with the microbial coronal leakage.
195

Técnicas de redução de potência estática em memórias CMOS SRAM e aplicação da associação de MOSFETs tipo TST em nano-CMOS / Static energy reduction techniques for CMOS SRAM memories and TST MOSFET association application for nano-CMOS

Conrad Junior, Eduardo January 2009 (has links)
Em nossos dias a crescente busca por portabilidade e desempenho resulta em esforços focados na maximização da duração de bateria dos equipamentos em fabricação, ou seja, busca-se a conflitante solução de circuitos com baixo consumo e ao mesmo tempo com alto desempenho. Neste contexto usualmente na composição de equipamentos portáteis empregam-se SOC´s (Systems On Chip) o que barateia o custo de produção e integração destes circuitos. SOC´s são sistemas completos que executam uma determinada função integrados em uma pastilha de silício única, normalmente possuem memórias SRAM como componente do sistema, que são utilizadas como memórias de alta performance e baixa latência e/ou também como caches. O grande desafio de projeto em memórias SRAMS é a relação de desempenho versus potência consumida a ser otimizada. Basicamente por sua construção estes circuitos apresentam alto consumo de potência, dinâmica e estática, relacionada a primeira diretamente ao aumento de freqüência de operação. Um dos focos desta dissertação é explorar soluções para a redução de consumo de energia tanto dinâmica como estática, sendo a redução de consumo estático de células de memória em standby buscando desempenho, estabilidade e baixo consumo de energia. No desenvolvimento de técnicas para projeto de circuitos analógicos em tecnologias nanométricas, os TST´s (T-Shaped Transistors – Transistor tipo T) surgem como dispositivos com características potenciais para projeto analógico de baixa potência. TSTs / TATs (Trapezoidal Associations of Transistors – Associação Trapezoidal de transistores) são estruturas self-cascode que podem tornar-se uma boa escolha por apresentar redução do leakage, redução na área utilizada e com incremento na regularidade do layout e no casamento entre transistores, propriedade importantíssima para circuitos analógicos. Sendo este o segundo foco deste texto através do estudo e análise das medidas elétricas dos TSTs executadas para comprovação das características destes dispositivos. Também apresenta-se uma análise das possibilidades de utilização dos TSTs em projeto analógico para tecnologias nanométricas. / Nowadays the increasing needs for portability and performance has resulted in efforts to increase battery life, i. e., the conflicting demands for low power consumption and high performance circuits. In this context using SOC´s (System On Chip) in the development for portable equipments composition, an integration of an entire system for a given function in a single silicon die will provide less production costs and less integration costs. SOC´s normally include a SRAM memory as its building block and are used to achieve memories with low latency and short access time or (and) as caches. A performance versus power consumption analysis of SRAM memory building blocks shows a great challenge to be solved. The electrical design aspects of these blocks reveal high power consumption, dynamic and static, and the former is directly proportional to the operating frequency. The design space exploration for dynamic and leakage consumption reduction in these circuits is one of the focus of this work. The main contribution of this topic is the leakage reduction techniques based in performance, stability and low energy consumption for the memory cell stand-by mode. Among the electrical techniques developed for analog circuits at the 20-100 nanometer scale, the TST (T-Shaped Transistors) rises with potential characteristics for analog low power design. TST /TAT (Trapezoidal Associations of Transistors) are selfcascode structures and can be turning into a good alternative for leakage and area reduction. Another point is the increment in mismatch and layout regularity, all these characteristics being very important in analog designs. The TST electrical measurements study and analysis are developed to show the device properties. An analysis of the TST desired properties and extrapolation for nanometer technologies analog design are also presented.
196

Avaliação da capacidade de selamento de três materiais obturadores em canais radiculares de pré-molares de cães preparados para pino intra-radicular expostos ao meio bucal

Kopper, Patrícia Maria Poli January 2008 (has links)
O presente estudo teve como objetivo avaliar in vivo a capacidade de selamento de três materiais obturadores constituídos de cimentos endodônticos resinosos, sendo dois (AH Plus e EndoRez) associados a cones de guta-percha, e um (Real Seal) a cones de Resilon, em pré-molares de cães, expostos ao meio bucal, após o preparo para colocação de pino protético. Objetivou, também, avaliar a correlação entre a situação inflamatória dos tecidos periapicais e a infiltração microbiana. Para tal, foi realizado o preparo químico-mecânico de 80 dentes (160 canais), sendo dez (20 canais) em cada cão. Antes da obturação, os canais foram distribuídos, aleatoriamente, em sete grupos. Nos grupos I – GI (n=32) e controle negativo I – C-I (n=16), os canais foram obturados com cones de guta-percha e AH Plus; nos grupos II – GII (n=32) e controle negativo II – C-II (n=16), com cones de guta-percha e EndoRez; e nos grupos III – GIII (n=32) e controle negativo III – C-III (n=16), com cones de Resilon e Real Seal. Os canais do grupo controle positivo – C+ (n=16) não foram obturados. Imediatamente após a obturação, realizou-se a desobturação parcial dos canais, restando 4 mm de material na região apical. Os dentes foram selados, provisoriamente, com amálgama de prata, durante 72 horas. Após esse período, o selamento coronário de todos os canais, com exceção dos pertencentes aos grupos C-, foi removido, ficando expostos ao meio bucal por 90 dias. Os animais foram mortos, e as mandíbulas e maxilas removidas e seccionadas, separando-se o lado esquerdo do direito. Nos dentes das hemi-arcadas do lado esquerdo, o selamento dos canais dos grupos C- foi removido e o espaço protético irrigado, abundantemente, com água destilada. Após, foram secos e preenchidos com tinta nanquim. Os dentes foram, novamente, selados e, passadas 96 horas, extraídos. A seguir, as raízes foram separadas, armazenadas em tubos de ensaio e diafanizadas. Os espécimes do lado direito foram processados histologicamente, empregando-se as colorações de Hematoxilina e Eosina de Harris (HE) e Brown e Brenn (BB). A infiltração de corante foi medida com auxílio de lupa esteroscópica, com aumento de 10x. A análise dos cortes histológicos foi realizada em microscópio óptico, classificando-se o estado inflamatório dos tecidos periapicais e a infiltração microbiana em escores de 1 a 4. Os resultados da infiltração de corante evidenciaram que todos os grupos apresentaram menor infiltração que o grupo C+ (p<0,001) e que os grupos GI, GII e GIII não diferiram significativamente (P>0,05). O grupo GII apresentou diferenças significativas em relação ao seu grupo controle negativo, mostrando maior infiltração de corante (P<0,001). Na análise histológica, todos os materiais testados apresentaram menor grau de reação inflamatória e de infiltração microbiana, quando comparados com o grupo C+ (P≤0,001). Além disso, não foram observadas diferenças significativas entre os grupos GI, GII e GIII, bem como destes com seus respectivos controles (P>0,05). O teste de correlação de Spearman mostrou uma forte correlação entre resposta inflamatória e infiltração microbiana (rs= 0,57; P<0,001). A partir do exposto, concluiu-se que os materiais testados não apresentaram diferenças significativas entre si e que a resposta inflamatória periapical apresentou correlação direta com a infiltração coronária microbiana. / The aim of this study was to assess in vivo the sealing ability of three resin-containing endodontic sealers, two associated with gutta-percha points (AH Plus and EndoRez) and one associated with Resilon points (RealSeal). Mongrel dogs had their premolars prepared and filled, then post-prepared, which space became exposed to the oral environment. The correlation between inflammatory condition and level of microbial leakage was also tested. For that purpose, 80 teeth (160 root canals), being 10 (20 root canals), for each dog, were chemo-mechanically prepared and randomly divided into the following groups: GI (n=32) and C-I (negative control; n=16): root filling with gutta-percha and AH-Plus; GII (n=32) and C-II (n=16): root filling with gutta-percha and Endorez; GIII (n=32) and C-III (n=16): root filling with Resilon and RealSeal; C+ (positive control; n=16): no root filling. Immediately following filling procedures, post space preparation was done leaving 4mm of filling material apically. Teeth had their crowns provisionally sealed with amalgam for 72 hours. Then, coronal seal was removed (except for C-) and remained exposed to the oral environment for 90 days. The dogs were sacrificed and their mandible and maxilla were removed and sectioned, separating right and left sides. In the specimens from the left side, the C- teeth had their seal removed, and all teeth had their post space irrigated with distilled water, then filled with India ink. Following 96 hours, the teeth were extracted. Roots were labeled as to the groups and subjected to clearing process in test tubes. The specimens from the right side were histologically processed and stained with Hematoxicilin and Eosin (HE) and Brown and Brenn (BB). The ink leakage was measured three dimensionally under stereoscope microscopy (10x). Histological sections were assessed under light microscopy by a senior observer blinded as to the groups and the inflammatory state was classified using scores varying from 1 to 4 in an ascending severity. The same severity scoring applied to the microbial leakage, being the severity scored as to the depth of microbial penetration within the dentinal tubules. The results showed that all the test groups displayed less leakage than C+ group (P<0,001). GI, GII and GIII did not differ statistically amongst them. Sealing ability of GII differed significantly to its control group – C-II (P<0,001).Histological analysis showed that all test groups displayed lower inflammatory reaction and microbial leakage when compared to C+ group (P≤0,001). No significant differences were found amongst GI, GII and GIII and their respective controls (p>0,05). Spearman correlation test showed a strong correlation between inflammatory response and microbial leakage (rs= 0,57; P<0,001). It could be concluded that the tested materials did not differ amongst themselves and that the periapical tissue response correlated directly with the microbial coronal leakage.
197

Medida do buckling e da probabilidade de fuga de nêutrons do núcleo do reator IPEN/MB-01 / Determination of buckling and probability of leakage of neutron in the IPEN/MB-01 reactor in cylindrical configuration

Purgato, Rafael Turrini 24 September 2014 (has links)
Um dos parâmetros fundamentais da física de reatores é a curvatura do fluxo de nêutrons (Buckling) do núcleo do reator. Ele está relacionado com outros parâmetros importantes, tais como as taxas de reação, potencia de operação, queima de combustível, entre outros. Num reator crítico, o Buckling depende das características geométricas e de material do núcleo do reator. Este trabalho apresenta os resultados do Buckling experimental para o reator nuclear IPEN/MB-01 em sua configuração cilíndrica com 28 barras de combustível ao longo de seu diâmetro. O IPEN/MB-01 é um reator de potência zero projetado para operar em uma potência máxima nominal de 100 watts. É uma instalação nuclear versátil que permite a simulação de todas as características de um grande reator nuclear e ideal para este tipo de medição. Foi realizado um mapeamento do fluxo de nêutrons no interior do reator e, assim, determinado o Buckling total da configuração cilíndrica. O reator foi operado durante uma hora para cada experimento. Em seguida, a taxa de reação nuclear das varetas de combustível foram medidas por espectrometria gama em um detector de germânio hiper-puro (HPGe) que escaneou as varetas axial e radialmente. Foram analisados os fótons gama do 239Np ( 276,6 keV ), gerado a partir da captura de nêutrons epitérmicos e rápidos, e do 143Ce ( 293,3 keV ), gerado por fissão em ambos 238U e 235U, respectivamente. Foram analisadas as direções axial e radial. Outras medições foram realizadas com fios e folhas de ouro nas direções radial e axial do núcleo do reator. O Buckling total obtido a partir da média ponderada dos três métodos medidos é de 96,55 ± 7,47 m-2. Os objetivo dos valores experimentais obtidos é obter um conjunto de dados experimentais que permitam uma comparação direta com valores calculados pelos códigos de Física de Reatores CITATION e MCNP. / One of the key parameters in reactor physics is the Buckling of a reactor core. It is related to important parameters such as reaction rates, nuclear power operation, fuel burning, among others. In a critical reactor, the Buckling depends on the geometric and material characteristics of the reactor core. This work presents the results of experimental Buckling in the reactor IPEN/MB-01 nuclear reactor in its cylindrical configuration with 28 fuel rods along its diameter. The IPEN/MB-01 is a zero power reactor designed to operate at a maximum power of 100 watts, it is a versatile nuclear facility which allows the simulation of all the characteristics of a large nuclear power reactor and ideal for this type of measurement. We conducted a mapping of neutron flux inside the reactor and thereby determined the total Buckling of the cylindrical configuration. The reactor was operated for one hour. Then, the activity of the fuel rods was measured by gamma spectrometry on a rod scanner HPGe detector. We analyzed the gamma photons of the 239Np (276,6 keV) for neutron capture (n,&gamma;) and the 143Ce (293,3 keV) for fission (n,f) on both 238U and 235U, respectively. We analyzed the axial and radial directions. Other measurements were performed using wires and gold foils in the radial and axial directions of the reactor core. The Buckling Total obtained from the three methods by weighted mean is 96,55 ± 7,47 m-2. The goal is to obtain experimental values of a set of experimental data to allow one direct comparison with values calculated by the codes used in reactor physics CITATION and MCNP.
198

Design of signal integrity enhancement circuits

Lee, Kil-Hoon 11 November 2010 (has links)
This dissertation is aimed at examining signal integrity degradation factors and realizing signal integrity enhancement circuits for both wired and wireless communication systems. For wired communication systems, an optical coherent system employing an electrical equalization circuit is studied as a way of extending the transmission distance limited by optical fiber dispersion mechanisms. System simulation of the optical coherent receiver combined with the feed-forward equalizers is performed to determine the design specification of the equalizer circuit. The equalization circuit is designed and implemented in a 0.18 µm complementary metal-oxide semiconductor (CMOS) process and demonstrates the capability to extend the transmission reach of long-haul optical systems over single-mode fiber to 600 km. Additionally, for wireless applications, signal integrity issues found in a full-duplex wireless communication network are examined. Full-duplex wireless systems are subject to interference from their own transmitter leakage signals; thus, a transmitter leakage cancellation circuit is designed and implemented in a 0.18 µm CMOS technology. The proposed cancellation circuit is integrated with a low-noise amplifier and demonstrates over 20 dB of transmitter leakage signal suppression.
199

Zdroje rizika chladících zařízení s amoniakem a jejich případné havarijní dopady / Risk sources of ammonia refrigeration equipment and their possible impacts

MIRANDOVÁ, Růžena January 2010 (has links)
I have decided to deal with the issue of "Risk Sources of Ammonia Cooling Systems and Their Eventual Accidental Impacts" as the risk of leakage from the cooling systems using ammonia as a coolant still prevails these days. Eventual accidental leakage simulation models were applied to several winter stadiums using ammonia as a coolant. Based on these results, it has been assessed how dangerous these sources for the citizens living in their surroundings are and measures to increase safety were suggested, too.
200

Medida do buckling e da probabilidade de fuga de nêutrons do núcleo do reator IPEN/MB-01 / Determination of buckling and probability of leakage of neutron in the IPEN/MB-01 reactor in cylindrical configuration

Rafael Turrini Purgato 24 September 2014 (has links)
Um dos parâmetros fundamentais da física de reatores é a curvatura do fluxo de nêutrons (Buckling) do núcleo do reator. Ele está relacionado com outros parâmetros importantes, tais como as taxas de reação, potencia de operação, queima de combustível, entre outros. Num reator crítico, o Buckling depende das características geométricas e de material do núcleo do reator. Este trabalho apresenta os resultados do Buckling experimental para o reator nuclear IPEN/MB-01 em sua configuração cilíndrica com 28 barras de combustível ao longo de seu diâmetro. O IPEN/MB-01 é um reator de potência zero projetado para operar em uma potência máxima nominal de 100 watts. É uma instalação nuclear versátil que permite a simulação de todas as características de um grande reator nuclear e ideal para este tipo de medição. Foi realizado um mapeamento do fluxo de nêutrons no interior do reator e, assim, determinado o Buckling total da configuração cilíndrica. O reator foi operado durante uma hora para cada experimento. Em seguida, a taxa de reação nuclear das varetas de combustível foram medidas por espectrometria gama em um detector de germânio hiper-puro (HPGe) que escaneou as varetas axial e radialmente. Foram analisados os fótons gama do 239Np ( 276,6 keV ), gerado a partir da captura de nêutrons epitérmicos e rápidos, e do 143Ce ( 293,3 keV ), gerado por fissão em ambos 238U e 235U, respectivamente. Foram analisadas as direções axial e radial. Outras medições foram realizadas com fios e folhas de ouro nas direções radial e axial do núcleo do reator. O Buckling total obtido a partir da média ponderada dos três métodos medidos é de 96,55 ± 7,47 m-2. Os objetivo dos valores experimentais obtidos é obter um conjunto de dados experimentais que permitam uma comparação direta com valores calculados pelos códigos de Física de Reatores CITATION e MCNP. / One of the key parameters in reactor physics is the Buckling of a reactor core. It is related to important parameters such as reaction rates, nuclear power operation, fuel burning, among others. In a critical reactor, the Buckling depends on the geometric and material characteristics of the reactor core. This work presents the results of experimental Buckling in the reactor IPEN/MB-01 nuclear reactor in its cylindrical configuration with 28 fuel rods along its diameter. The IPEN/MB-01 is a zero power reactor designed to operate at a maximum power of 100 watts, it is a versatile nuclear facility which allows the simulation of all the characteristics of a large nuclear power reactor and ideal for this type of measurement. We conducted a mapping of neutron flux inside the reactor and thereby determined the total Buckling of the cylindrical configuration. The reactor was operated for one hour. Then, the activity of the fuel rods was measured by gamma spectrometry on a rod scanner HPGe detector. We analyzed the gamma photons of the 239Np (276,6 keV) for neutron capture (n,&gamma;) and the 143Ce (293,3 keV) for fission (n,f) on both 238U and 235U, respectively. We analyzed the axial and radial directions. Other measurements were performed using wires and gold foils in the radial and axial directions of the reactor core. The Buckling Total obtained from the three methods by weighted mean is 96,55 ± 7,47 m-2. The goal is to obtain experimental values of a set of experimental data to allow one direct comparison with values calculated by the codes used in reactor physics CITATION and MCNP.