Spelling suggestions: "subject:"[een] LONGITUDINAL REINFORCEMENT"" "subject:"[enn] LONGITUDINAL REINFORCEMENT""
1 |
Numerical Modeling of Helical Pile-to-Foundation Connections subjected to Monotonic and Cyclic LoadsChiluwal, Sundar January 2019 (has links)
No description available.
|
2 |
Análise experimental de emenda em armadura longitudinal de pilares curtos de concretoCintra, Danielli Cristina Borelli 28 November 2013 (has links)
Made available in DSpace on 2016-12-23T14:05:54Z (GMT). No. of bitstreams: 1
Danielli Cristina Borelli Cintra.pdf: 4222911 bytes, checksum: 0db55771987e1317b678d8aff9ba3ab7 (MD5)
Previous issue date: 2013-11-28 / The lap splice of the longitudinal reinforcement of columns positioned at the base, widely used in the execution of multiple floors structures in reinforced concrete floors, is the most vulnerable point in the pathological manifestations columns of buildings, compromising the structural performance and durability of the building. This region suffers from the stage of concrete, the high concentration of bars and high altitude release of concrete that promote segregation of the aggregate, and hinder access to the consolidation. During the life of the structure, is a region of high concentration of efforts, especially in columns bracing and often exposed to aggressive agents, such as the accumulation of waste chemicals, cleaning and humidity. The present work is an experimental and statistical study of the behavior at break of 31 short columns reinforced concrete subjected to concentric compression. All columns possessed cross section of 19cm x 19cm, height 170cm, concrete strength around 30MPa and longitudinal geometric rate of 0.88%. Varied only the position and the length of the lap splice to analyze the influence of these two factors and the interaction between them in the capacity of the columns. Are analyzed qualitatively manufacturing procedures samples of columns, which were close to the conditions of execution of the columns in the works. We used a factorial design to statistically analyze the experimental results, which confirmed the hypothesis that none of the factors applied, even the interaction between them, would be significant for the load capacity of the columns / A emenda por traspasse de armadura longitudinal posicionada na base de pilares, largamente utilizada na execução de estruturas de múltiplos pavimentos em concreto armado, consiste num dos pontos mais vulneráveis às manifestações patológicas em pilares de edifícios, comprometendo o desempenho estrutural e durabilidade da edificação. Tal região é prejudicada, desde a etapa de concretagem, pela alta concentração de armadura e pela altura elevada de lançamento do concreto, que promovem a segregação do agregado, além de dificultarem o acesso para o adensamento. Durante a vida útil da estrutura, é uma região de alta concentração de esforços e geralmente exposta a agentes agressivos, como o acúmulo de resíduos de produtos químicos, de limpeza e umidade. O presente trabalho trata-se de um estudo experimental e estatístico do comportamento até a ruptura de 31 pilares curtos de concreto armado, submetidos à compressão centrada. Todos os pilares possuíam seção transversal de 19cm x 19cm, altura de 170cm, resistência do concreto em torno de 30MPa e taxa geométrica de armadura longitudinal de 0,88%. Variou-se apenas a posição da emenda e o comprimento de traspasse da armadura longitudinal para analisar a influência desses dois fatores e da interação entre eles na capacidade de carga dos pilares. São analisados qualitativamente os procedimentos de fabricação das amostras de pilares, que foram próximos às condições de execução de pilares em obras. Utilizou-se um planejamento fatorial para analisar estatisticamente os resultados experimentais, que confirmou as hipóteses de que nenhum dos fatores adotados, nem mesmo a interação entre eles, seriam significativos para a capacidade de carga dos pilares
|
3 |
Procedimentos de cálculo, verificação e detalhamento de armaduras longitudinais na seção transversal em elementos protendidos / Calculation procedure, verification and detailing of longitudinal reinforcement in the cross section of prestressed elementsFaleiros Junior, José Herbet 24 August 2010 (has links)
Made available in DSpace on 2016-06-02T20:09:13Z (GMT). No. of bitstreams: 1
3262.pdf: 8603825 bytes, checksum: 51c881687adbb3d6b1750785d0cfee94 (MD5)
Previous issue date: 2010-08-24 / The following paper presents methods of calculation, verification and detailing of prestressed longitudinal reinforcement in cross sections of elements subjected to bending conceptualizing prestressing systems and its constituent elements, as well as the development of practical examples, calculated and detailed in a didactic manner, seeking an easy understanding and learning. The present study chooses to calculate the longitudinal reinforcement at the ultimate limit state and check it out at the serviceability limit state, always following the current standards. To organize the concepts and cohesion of the information, it is necessary to discuss theoretical and conceptual foundation by assembling several authors who derive about the subject matter. In order to ensure the adoption of normative recommendations (NBR6118:2007 e NBR9062:2005), issues such as durability, cover, classes of environmental aggressiveness, combinations of calculating and limiting values of prestress are discussed. As an example, it is presented a calculation discussion from a structure tailored to different classes of environmental aggressiveness, maintaining its main features, such as: the vain, the cross section and loads. With this work we realize that the calculations are needed, since there is not a situation which determines the scaling of the longitudinal reinforcement. Lastly, we present suggestions for future papers. In order to maintain the geometric features needed to the placement of the active armor on the top edge and on the replacement of the active armor by the passive one at any percentage can only be accomplished in partial prestress. The concurrent examinations may prevent the use of certain sections, for example, when examinations on empty are exclusive, or when the moment value relative to the weight itself is small in relation to the total moment. / O presente trabalho apresenta métodos de cálculo, verificação e detalhamento de armaduras longitudinais protendidas nas seções transversais de elementos submetidos à flexão conceituando os sistemas de protensão e seus elementos constituintes, bem como, o desenvolvimento de exemplos práticos, calculados e detalhados de maneira didática, visando um fácil entendimento e aprendizado. Neste trabalho opta-se por calcular a armadura longitudinal no estado limite último e verificá-la no estado limite de serviço, seguindo sempre as normas vigentes. Para a organização dos conceitos e coesão das informações, faz-se necessária a discussão teórica e o embasamento dos conceitos através da reunião de diversos autores que discorrem sobre o assunto abordado. Pretendendo garantir a adoção das recomendações normativas (NBR6118:2007 e NBR9062:2005), são discutidas questões como durabilidade, cobrimentos, classes de agressividade ambiental, combinações de cálculo e valores limites de protensão. Na forma de exemplo, é apresentada uma discussão de cálculo a partir de uma estrutura dimensionada para variadas classes de agressividade ambiental, mantendo suas características principais, como: o vão, a seção transversal e os carregamentos. Com o trabalho percebe-se que são necessários os cálculos, pois não há uma situação determinante para o dimensionamento da armadura longitudinal. Para que se mantenham as características geométricas é necessária a colocação de armadura ativa na borda superior e na substituição da armadura ativa pela passiva em qualquer porcentagem só pode ser realizada na protensão parcial. As verificações simultâneas podem inviabilizar o uso de certas seções, por exemplo, quando as verificações em vazio são excludentes, ou quando, o valor do momento relativo ao peso próprio é pequeno em relação ao momento total. Por fim são apresentadas sugestões para trabalhos futuros.
|
4 |
[en] BUCKLING ANALYSIS OF LONGITUDINAL REINFORCEMENT IN CONCRETE COLUMNS / [pt] ESTUDO DA FLAMBAGEM DE ARMADURAS LONGITUDINAIS EM PILARES DE CONCRETO ARMADOSALETE SOUZA DE OLIVEIRA BUFFONI 27 September 2004 (has links)
[pt] A flambagem das armaduras longitudinais em pilares de
concreto armado
pode ocorrer na região entre dois estribos consecutivos, ou
pode envolver um
certo número de estribos. As normas de projeto existentes
não fornecem uma
metodologia apropriada para o dimensionamento dos estribos
em diferentes
situações. O presente trabalho tem por objetivo desenvolver
uma formulação que
permita analisar a flambagem das armaduras longitudinais em
pilares de concreto
armado submetidos a carregamento axial levando em conta o
espaçamento entre
os estribos, o diâmetro e arranjo dos estribos na seção
transversal e o diâmetro das
armaduras longitudinais. Para este propósito um método
analítico para a avaliação
da flambagem da armadura longitudinal é proposto,
considerando-se as barras
longitudinais restringidas pela rigidez axial ou à flexão
dos estribos. Admite-se
que a armadura longitudinal funciona como uma coluna
esbelta. Consideram-se
duas formas de modelagem da atuação dos estribos: como
apoios elásticos
discretos e como base elástica contínua. O presente
trabalho trata a coluna com
um ou mais modos de deformação, incluindo certas não-
linearidades. São
fornecidos cargas críticas e caminhos pós-críticos para
tais casos. Como resultado
deste estudo, apresenta-se uma proposta para
dimensionamento racional dos
estribos que permite estudar diferentes alternativas em um
ábaco de utilização
simples para projeto. Apresentam-se comparações com
resultados experimentais
da literatura em pilares de concreto armado. Isto permite
uma avaliação crítica dos
desenvolvimentos teóricos realizados e da forma proposta de
dimensionamento
racional dos estribos. / [en] Buckling of longitudinal reinforcement in reinforced
concrete columns may
occur in the region between two consecutive ties, or may
involve a number of ties.
The existing design code specifications do not provide an
appropriate
methodology for the design of the transversal reinforcement
in different situations.
The main objective of the present work is to develop a
formulation to allow to
analyze the buckling of longitudinal bars in reinforced
concrete columns taking
into account the tie spacing, the diameter and arrangement
of the ties in the cross
section and the longitudinal bar diameter. For this purpose
an analytical method
for the evaluation of the buckling load of longitudinal
bars is described, as a
function of the constraint imposed by the axial or flexural
stiffness of the stirrups.
The longitudinal bar is considered as a column deforming
according to thin beam
theory. The tie action is described either by a set
discrete elastic supports or by a
continuous elastic foundation. The theoretical analysis
considers the column with
one or more deformation modes, with some degree of
nonlinearity, including the
analysis of post-critical equilibrium paths. As a result of
this study, rational
criteria for spacing and sizing of transversal
reinforcement are derived, allowing
to study different alternatives in an abacus of simple use
for design. Several
comparisons with the results obtained experimentally by
other authors in
reinforced concrete columns are presented, allowing for an
evaluation of the
validity of the theoretical developments and the rational
design methodology
proposed herein.
|
Page generated in 0.0335 seconds