• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 6
  • 5
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 49
  • 49
  • 35
  • 23
  • 19
  • 12
  • 9
  • 8
  • 8
  • 8
  • 7
  • 7
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

A supercritical R-744 heat transfer simulation implementing various Nusselt number correlations / Philip van Zyl Venter.

Venter, Philip van Zyl January 2010 (has links)
During the past decade research has shown that global warming may have disastrous effects on our planet. In order to limit the damage that the human race seems to be causing, it was acknowledged that substances with a high global warming potential (GWP) should be phased out. In due time, R-134a with a GWP = 1300, may probably be phased out to make way for nature friendly refrigerants with a lower GWP. One of these contenders is carbon dioxide, R-744, with a GWP = 1. Literature revealed that various Nusselt number (Nu) correlations have been developed to predict the convection heat transfer coefficients of supercritical R-744 in cooling. No proof could be found that any of the reported correlations accurately predict Nusselt numbers (Nus) and the subsequent convection heat transfer coefficients of supercritical R-744 in cooling. Although there exist a number of Nu correlations that may be used for R-744, eight different correlations were chosen to be compared in a theoretical simulation program forming the first part of this study. A water-to-transcritical R-744 tube-in-tube heat exchanger was simulated. Although the results emphasise the importance of finding a more suitable Nu correlation for cooling supercritical R-744, no explicit conclusions could be made regarding the accuracy of any of the correlations used in this study. For the second part of this study experimental data found in literature were used to evaluate the accuracy of the different correlations. Convection heat transfer coefficients, temperatures, pressures and tube diameter were employed for the calculation of experimental Nusselt numbers (Nuexp). The theoretical Nu and Nuexp were then plotted against the length of the heat exchanger for different pressures. It was observed that both Nuexp and Nu increase progressively to a maximal value and then decline as the tube length increases. From these results it were possible to group correlations according to the general patterns of their Nu variation over the tube length. Graphs of Nuexp against Nus, calculated according to the Gnielinski correlation, generally followed a linear regression, with R2 > 0.9, when the temperature is equal or above the pseudocritical temperature. From this data a new correlation, Correlation I, based on average gradients and intersects, was formulated. Then a modification on the Haaland friction factor was used with the Gnielinski correlation to yield a second correlation, namely Correlation II. A third and more advanced correlation, Correlation III, was then formulated by employing graphs where gradients and y-intercepts were plotted against pressure. From this data a new parameter, namely the turning point pressure ratio of cooling supercritical R-744, was defined. It was concluded that the employed Nu correlations under predict Nu values (a minimum of 0.3% and a maximum of 81.6%). However, two of the correlations constantly over predicted Nus at greater tube lengths, i.e. below pseudocritical temperatures. It was also concluded that Correlation III proved to be more accurate than both Correlations I and II, as well as the existing correlations found in the literature and employed in this study. Correlation III Nus for cooling supercritical R-744 may only be valid for a diameter in the order of the experimental diameter of 7.73 mm, temperatures that are equal or above the pseudocritical temperature and at pressures ranging from 7.5 to 8.8 MPa. / Thesis (M.Ing. (Mechanical Engineering))--North-West University, Potchefstroom Campus, 2010.
12

A supercritical R-744 heat transfer simulation implementing various Nusselt number correlations / Philip van Zyl Venter.

Venter, Philip van Zyl January 2010 (has links)
During the past decade research has shown that global warming may have disastrous effects on our planet. In order to limit the damage that the human race seems to be causing, it was acknowledged that substances with a high global warming potential (GWP) should be phased out. In due time, R-134a with a GWP = 1300, may probably be phased out to make way for nature friendly refrigerants with a lower GWP. One of these contenders is carbon dioxide, R-744, with a GWP = 1. Literature revealed that various Nusselt number (Nu) correlations have been developed to predict the convection heat transfer coefficients of supercritical R-744 in cooling. No proof could be found that any of the reported correlations accurately predict Nusselt numbers (Nus) and the subsequent convection heat transfer coefficients of supercritical R-744 in cooling. Although there exist a number of Nu correlations that may be used for R-744, eight different correlations were chosen to be compared in a theoretical simulation program forming the first part of this study. A water-to-transcritical R-744 tube-in-tube heat exchanger was simulated. Although the results emphasise the importance of finding a more suitable Nu correlation for cooling supercritical R-744, no explicit conclusions could be made regarding the accuracy of any of the correlations used in this study. For the second part of this study experimental data found in literature were used to evaluate the accuracy of the different correlations. Convection heat transfer coefficients, temperatures, pressures and tube diameter were employed for the calculation of experimental Nusselt numbers (Nuexp). The theoretical Nu and Nuexp were then plotted against the length of the heat exchanger for different pressures. It was observed that both Nuexp and Nu increase progressively to a maximal value and then decline as the tube length increases. From these results it were possible to group correlations according to the general patterns of their Nu variation over the tube length. Graphs of Nuexp against Nus, calculated according to the Gnielinski correlation, generally followed a linear regression, with R2 > 0.9, when the temperature is equal or above the pseudocritical temperature. From this data a new correlation, Correlation I, based on average gradients and intersects, was formulated. Then a modification on the Haaland friction factor was used with the Gnielinski correlation to yield a second correlation, namely Correlation II. A third and more advanced correlation, Correlation III, was then formulated by employing graphs where gradients and y-intercepts were plotted against pressure. From this data a new parameter, namely the turning point pressure ratio of cooling supercritical R-744, was defined. It was concluded that the employed Nu correlations under predict Nu values (a minimum of 0.3% and a maximum of 81.6%). However, two of the correlations constantly over predicted Nus at greater tube lengths, i.e. below pseudocritical temperatures. It was also concluded that Correlation III proved to be more accurate than both Correlations I and II, as well as the existing correlations found in the literature and employed in this study. Correlation III Nus for cooling supercritical R-744 may only be valid for a diameter in the order of the experimental diameter of 7.73 mm, temperatures that are equal or above the pseudocritical temperature and at pressures ranging from 7.5 to 8.8 MPa. / Thesis (M.Ing. (Mechanical Engineering))--North-West University, Potchefstroom Campus, 2010.
13

Medidas de permeabilidade e de condutividade termica efetiva em isolamentos termicos tipo fibra

KASSAR, EDSON 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:30:57Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:17Z (GMT). No. of bitstreams: 1 01386.pdf: 5820506 bytes, checksum: 6308c9f7dae1ed503a75ddfa5a2542db (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
14

Medidas de permeabilidade e de condutividade termica efetiva em isolamentos termicos tipo fibra

KASSAR, EDSON 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:30:57Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:17Z (GMT). No. of bitstreams: 1 01386.pdf: 5820506 bytes, checksum: 6308c9f7dae1ed503a75ddfa5a2542db (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
15

Heat transfer characteristics of a fractal heat exchanger

Van der Vyver, Hilde 22 January 2009 (has links)
D.Ing.
16

Data acquisition system for determining heat transfer coefficients in a heat pump

Van der Hoek, Leon 20 August 2012 (has links)
M.Ing. / Heat pump water heaters (HPWHs) have been identified as a viable replacement for electrical resistance heaters due to their high efficiency and reliability. Heat exchangers are a crucial part of HPWHs, and play a vital role in improving the system's coefficient of performance (COP). Experimentally analysing a heat exchanger is usually a slow and highly labour intensive practice since vast amounts of data have to be logged and mathematically manipulated to obtain results. A lot of time and money could be saved, if this process were to be automated. The first objective of this study was to develop a software program capable of calculating the heat transfer correlation constants of a tube-in-tube heat exchanger using the modified Wilson plot technique from data obtained through water-to-water experimentation at different flow rates and temperatures. The data was to be captured by using data acquisition equipment capable of measuring temperature from several Ptl 00-type temperature sensors, pressure transducers as well as Coriolis flow meters, all within a few seconds, thus giving virtually steady-state measurements. The second objective of this study was to develop a software package, capable of capturing and manipulating data from a HPWH system using the same tube-in-tube heat exchanger and using R-22 as refrigerant. The software package had to be capable of capturing all the required experimental data from the system and calculate the local and average heat transfer coefficients on-line and display it to the user. It also had to capture it in the form of a spreadsheet data file for further manipulation. The success of the software package would depend on the results achieved, as well as the time saved with its implementation. To verify the results, the output of the program was compared with the findings of various other researchers. It was found that the output of the program compared well with the results obtained by other researchers, both for the average heat transfer coefficient as well as the local heat transfer coefficients. The time taken for a full set of data was as little as 30 minutes, compared to many hours previously needed to achieve stable results. The software package has thus succeeded in fulfilling its objective to reduce the time taken to achieve accurate results during heat transfer experimentation.
17

Characteristics of a semicircular heat exchanger used in a water heated condenser pump

Da Veiga, Willem Richter 26 February 2009 (has links)
D.Ing. / According to literature 6% of South Africa’s primary energy consumption could be saved if heat pumps were used to their full technical potential. Although there is world-wide interest in the use of heat pumps and considerable effort has been expended on heat-pump research, heat pumps are not commonly used in South Africa. The objective of this thesis is to determine the possibility of a combined evaporator or condenser with a normal pump. This will reduce cost and space of a normal heat pump and make heat pumps economically more competitive against resistance element geysers. In order to investigate this combination research is done on semicircular heat exchangers, since this is the primary geometry of the heating channels in the condenser pump. Analyses is done experimentally on a standard 28.58 mm hard drawn copper tube, cut trough the middle, with a 1.6 mm copper plate in between to obtain a semicircular heat exchanger. Turbulent flow is investigated with the flat side of the semicircular heat exchanger being horizontal or vertical, a spiralled and a s-shape semicircular heat exchanger. In each case the heat transfer coefficient is determined with the use of the Wilson plot technique. It is found that there is a significant increase in Nusselt number for semicircular heat exchangers above a normal tube-in-tube heat exchanger but the pressure loss coefficient increase with an equal amount.
18

Experimental investigation of circumferentially non-uniform heat flux on the heat transfer coefficient in a smooth horizontal tube with buoyancy driven secondary flow

Reid, W.J. January 2018 (has links)
Most heat transfer tubes are designed for either fully uniform wall temperature or fully uniform wall heat flux boundary conditions under forced convection. Several applications, including but not limited to the solar collectors of renewable energy systems, do however operate with non-uniform boundary conditions. Limited research has been conducted on non-uniform wall heat flux heat transfer coefficients in circular tubes, especially for mixed convection conditions. Such works are normally numerical in nature and little experimental work is available. In this experimental investigation the effects of the circumferential heat flux distribution and heat flux intensity on the single phase (liquid) internal heat transfer coefficient were considered for a horizontal circular tube. Focus was placed on the laminar flow regime of water within a stainless steel tube with an inner diameter of 27.8 mm and a length to diameter ratio of 72. Different outer wall heat flux conditions, including fully uniform and partially uniform heat fluxes were studied for Reynolds numbers ranging from 650 to 2 600 and a Prandtl number range of 4 to 7. The heat flux conditions included 360˚ (uniform) heating, lower 180˚ heating, upper 180˚ heating, 180˚ left and right hemispherical heating, lower 90˚ heating, upper 90˚ heating and slanted 180˚ heating. Depending on the angle span of the heating, local heat fluxes of 6 631 W/m2 , 4 421 W/m2 , 3 316 W/m2 , 2 210 W/m2 and 1 658 W/m2 were applied. Results indicate that the local and average steady state Nusselt numbers are greatly influenced by the applied heat flux position and intensity. Highest average heat transfer coefficients were achieved for case where the applied heat flux was positioned on the lower half (in terms of gravity) of the tubes circumference, while the lowest heat transfer coefficients were achieved when the heating was applied to the upper half of the tube. Variations in the heat transfer coefficient were found to be due to the secondary buoyancy induced flow effect. The relative thermal performance of the different heating scenarios where characterised and described by means of newly developed heat transfer coefficient correlations for fully uniform heating, lower 180° heating, and upper 180° heating. / Dissertation (MEng)--University of Pretoria, 2018. / Mechanical and Aeronautical Engineering / MEng / Unrestricted
19

Premier pas vers la miniaturisation des cryoréfrigérateurs spatiaux / Next step towards the miniaturisation of space cryocoolers

Sochinskii, Arkadii 26 October 2018 (has links)
Ce travail a été effectué dans le cadre d’études de la miniaturisation d’un cryo-réfrigérateur de type tube à gaz pulsé (TGP) et particulièrement pour mieux comprendre l’écoulement et le transfert de chaleur dans un régénérateur, l’élément clé du TGP.Nous présentons les études numérique et expérimentale du facteur de frottement et du nombre de Nusselt pour les écoulements stationnaires et continus à nombre de Reynolds modéré O(1 − 100) au sein d’un régénérateur micro-fabriqué. L’influence de la porosité et de la géométrie est étudiée. La micro-structure précisément contrôlée représente des canaux incurvés de largeur de 10, 20 et 40 μm et de profondeur de 100 à 300 μm qui forment un réseau de colonnes ayant des profiles de losanges ou sinusoïdaux. Les micro-canaux sont gravés sur un substrat de silicium par la technologie DRIE. Une technologie d’implantation de thermomètres à l’intérieur de la micro-structure de régénérateur a été développée et mise en œuvre. Les performances des micro-régénérateurs ont été étudiées selon deux approches : la première se base sur le rapport des pertes de charges dans l’écoulement et de l’efficacité du transfert thermique (NPH/NTU) ; la deuxième, sur le coefficient de transfert de chaleur globale proposé par Bejan. L’étude numérique de ces deux critères montre tout le potentiel des micro-structures proposées. / This research is done in the framework of miniaturisation of pulse tube cryocoolers studies and especially to gain a better understanding of the mass flow and heat transfert in the regenerator, which is a crucial component of these type of cryocoolers.In this work we present a numerical and experimental study of the Darcy-Weisbach friction factor and Nusselt number for a continuous and steady flow at moderate Reynolds number O(1−100) in a micro-machined regenerators. The influence of porosity from 40 to 80 % and of the geometry parameters are studied. Well-controlled microstructures represent convoluted channels of 10, 20 or 40 μm width and 100 or 300 μm depth generated by rhombic- or sinusoidal-shaped columns.The channels are etched in Silicon wafers using DRIE MEMS technology. The thermometers are integrated inside the regenerator’s micro-structure to measure the temperature evolution. The efficiency of the regenerators is estimated using two different approaches : the first, as a ratio of pressure drop losses and heat transfer efficiency (NPH/NTU) ; the second, as a volumetric heat transfer density coefficient proposed by Bejan. The numerical study of the efficiency shows theinterest of proposed micro-structures.
20

The prediction of fully-developed friction factors and Nusselt Numbers for randomly rough surfaces

Manning, Spencer Haynes. January 2005 (has links)
Thesis (M.S.) -- Mississippi State University. Department of Mechanical Engineering. / Title from title screen. Includes bibliographical references.

Page generated in 0.0383 seconds