• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] PRIMARY AND HARMONIZATION OF THE REFERENCE VALUES: INTERNATIONAL EXPERIENCE AS CONTRIBUTION TO A BRAZILIAN SYSTEM FOR MEASURING THE FLOW OF NATURAL GAS / [pt] PADRONIZAÇÃO PRIMÁRIA E HARMONIZAÇÃO DE VALORES DE REFERÊNCIA: CONTRIBUIÇÃO DA EXPERIÊNCIA INTERNACIONAL À FORMULAÇÃO DE UM SISTEMA BRASILEIRO PARA MEDIÇÃO DE VAZÃO DE GÁS NATURAL

JULIO CESAR DA COSTA COMINGES 30 October 2008 (has links)
[pt] Objetivo da presente dissertação de mestrado é contribuir para a estruturação da cadeia metrológica de vazão de gás natural em alta pressão no Brasil, tomando como base experiências bem sucedidas de laboratórios nacionais de metrologia de vazão de países industrializados. O estudo fundamenta-se na padronização primária e na harmonização de valores padrões de referência para a medição de vazão. A falta de infra-estrutura metrológica para padronização primária de medição de vazão volumétrica de gás natural no Brasil constituiu-se na motivação da Petrobras para eliminar essa importante vulnerabilidade e, dessa forma, contribuir para o estabelecimento do controle metrológico no setor. A escolha do projeto de pesquisa também foi motivada pelo interesse pessoal do autor em contribuir para o tema tendo em vista sua trajetória profissional na Petrobras. A exemplo da experiência de outros países produtores de petróleo e gás natural, o trabalho se desenvolveu no contexto da regulação do setor, que criou oportunidades de investimentos e impôs desafios à metrologia brasileira. Demandas por medição fiscal de apoio a contratos de transferência de custódia exigiram a introdução de uma legislação específica e o desenvolvimento de procedimentos de avaliação da conformidade do gás natural, promissor insumo na matriz energética brasileira. O trabalho desenvolveu-se de acordo com a seguinte metodologia: (i) revisão das melhores práticas laboratoriais e dos modelos de padronização em uso por conceituados Institutos Nacionais de Metrologia de países produtores de petróleo e gás e (ii) na interpretação dos procedimentos de harmonização dos valores de referência utilizados pelos institutos nacionais de metrologia estudados. Dentre os resultados do estudo destaca-se a caracterização das cadeias de rastreabilidade para medição de vazão de gás natural em alta pressão em uso por institutos nacionais de metrologia que acordaram harmonizar seus valores de referência (PTB/Alemanha, LNE/França, NMi/Holanda). Disponibiliza-se, assim, um acervo de informações relevantes que poderá subsidiar a estruturação de um sistema de padronização primária no País. Como conclusão, o trabalho propõe a implementação de um modelo de poadronização primária para medição de vazão volumétrica de gás natural no Brasil. / [en] The objective of this Master dissertation in metrology is to contribute for structuring the Brazilian traceability chain for flow measurement of natural gas at high pressure, based on successful experiences of national metrology laboratories of highly industrialized countries. The study takes into account the primary standardization and harmonization of reference measurement standards. The lack of an adequate infrastructure for primary standardization of volumetric flow measurement of natural gas in Brazil was a motivation motivation for Petrobras to invest substantially to overcome this important vulnerability, thus contributing to the establishment of the metrological control in the gas sector. The choice of the research project was also motivated by the author`s personal interest to contribute to the advance knowledge in an area that he has been working for many years at Petrobras. Following the experience of other oil and gas producing countries, this project was developed in the context of the regulation for the sector creating opportunities for investment on quality infrastructure, imposing challenges for the Brazilian metrology. The need to implement a measuring fiscal scheme to support contracts for custody transfer required a specific legislation and the development of procedures for conformity assessment of natural gas. The work was developed in accordance with the following methodology: (i) review of best practices and models of laboratory standardization in use by authoritative national institutes of metrology of oil and gas producing countries and (ii) interpretation of procedures for harmonization of reference values used by the National Metrology Institutes studied. The main results obtained is the characterization of the traceability chain associated with natural gas for measurement at high pressure in use by European national metrology institutes (PTB/Germany, LNE/France, NMi/Netherlands) which have agreed to harmonize their reference values. Strategic information is then made available that could subsidize the structuring of a system of primary standardization of flow measurement in Brazil. In conclusion, this work has suggested a metrological scheme for implementing a sound gas flow measurement metrology primary standardization.
2

Padronização em sistema primário por coincidências 4πβ-γ e determinação das intensidades de emissão gama por decaimento dos radionuclídeos Cu-64 e Ho-166 / Primary standardization of 64Cu and 166Ho radionuclides in the 4πβ(PC)-γ coincidence system and determination of its gamma-ray emission probability per decay

Yamazaki, Ione Makiko 12 February 2019 (has links)
O Laboratório de Metrologia Nuclear (LMN) do Instituto de Pesquisas Energéticas e Nucleares (IPEN) realizou a padronização primária dos radionuclídeos 64Cu e 166Ho. Esses radioisótopos são utilizados na Medicina Nuclear em investigações diagnósticas e em radioterapia. A atividade absoluta foi determinada utilizando o método de coincidências 4πβ(PC)- γ associado à técnica de extrapolação de eficiência. Para isto, foram utilizados um contador proporcional em geometria 4π acoplado ao um contador de cintilação NaI (Tl). Para a padronização do 64Cu foram utilizados dois sistemas para registro de dados: sistema TAC e sistema SCS. No sistema TAC é utilizado o módulo Time to Amplitude Converter (TAC) associado a um analisador multicanal, sendo que a eficiência do detector 4πPC foi variada por meio de absorvedores externos e foi aplicado fator de correção para as eficiências beta denominado fator Kawada. No sistema SCS (Software Coincidence System) o registro dos eventos foi feito por meio da digitalização dos pulsos, a eficiência do detector 4πPC foi variada por discriminação eletrônica e a atividade foi obtida pela extrapolação biparamétrica. A padronização do 166Ho em sistema de coincidências 4πβ(PC)- γ foi realizada utilizando o sistema de aquisição de dados por software, SCS (Software Coincidence System). Para determinação das probabilidade de emissão gama dos radionuclídeos foi utilizado um espectrômetro gama HPGe calibrado com ampolas padrão de 152Eu, 60Co, 133Ba, 137Cs e 241Am, calibradas no sistema primário 4πβ(PC)- γ. A probabilidade de emissão gama por decaimento do fóton de 1345,7 keV do 64Cu obtida foi de 0,472 (10) % apresentando um bom acordo com os dados da literatura. A probabilidade de emissão gama por decaimento do fóton gama de 1379,45 keV do 166Ho foi de 0,936 (4) %. Por meio destas medidas foi possível também a determinação das intensidades relativas de outros fótons emitidos por este radionuclídeo. Os resultados obtidos foram concordantes com a literatura dentro da incerteza experimental. / The procedure followed by the Nuclear Metrology Laboratory (LMN) at the Nuclear and Energy Research Institute (IPEN) for the primary standardization of 64Cu and 166Ho is described. These radionuclides are widely applied to Nuclear Medicine such as in diagnostic investigations and in radiotherapy. The absolute activity of both radionuclides were determined by the efficiency extrapolation method applied to 4πβ(PC)-γ coincidence counting system using a proportional counter in 4π geometry coupled with NaI(Tl) scintillation counter. The primary standardisation of 64Cu for the conventional coincidence counting, the events were registered using a Time to Amplitude Converter (TAC) system associated with a multi-channel analyzer and by a software coincidence counting system, SCS, a digital method for primary activity measurements that simplifies the setting of optimal coincidence parameters. For perfoming the standardization of 64Cu in the TAC system, the efficiency of the 4πβ(PC)-γ detector was varied using external absorbers and in order to correct the beta efficiency, the Kawada factor was applied. In the SCS counting, the events were registered by means of pulse digitalization and the efficiencies (εEC and εβ) were varied through eletronic discrimination. The biparametric method was used for determining the absolute activity and the result was in good agreement with the ones obtained with TAC system. The standardization of 166Ho in the primary system was performed using the software coincidence counting, SCS. The gamma-ray emission probability per decay of the main transitions of both radionuclides were determined using the results obtained from the primary method, the 4πβ(PC)-γ coincidence system, associated with a calibrated HPGe gamma-ray spectrometer with standard ampoules of 152Eu, 60Co, 133Ba, 137Cs e 241Am, previously standardized in the 4πβ(PC)-γ system. The gamma-ray emission probability per decay of the 1345,7 keV transition of 64Cu was 0,472 (10) %, in good agreement with the literature. The gamma-ray emission probability per decay of the 1379,45 keV transition of 166Ho was 0,936 (4) %. It were also determined the relative gamma ray emmission probability of other gamma rays for this nuclide . All the results obtained were in good agreement with the literature.

Page generated in 0.0334 seconds