• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] ANALYSIS OF THE INFLUENCE OF VISCOSITY ON THE PETROLEUM FLOW RATE MEASUREMENT BY ULTRASONIC METERS / [pt] ANÁLISE DA INFLUÊNCIA DA VISCOSIDADE NA MEDIÇÃO DE VAZÃO DE PETRÓLEO POR MEDIDORES ULTRASSÔNICOS

WAGNER JOSÉ DOS SANTOS 07 November 2016 (has links)
[pt] No Brasil, a medição de petróleo é regulada pela ANP e pelo INMETRO. O Regulamento Técnico de Medição de Petróleo e Gás Natural exige que os medidores de vazão de petróleo sejam calibrados nas condições mais próximas das encontradas no local de medição, tanto para o fluido (massa específica e viscosidade) quanto operacionais (vazão, pressão e temperatura). Replicar todas estas condições nos laboratórios de calibração nacionais é muito complicado e dispendioso. Assim, neste trabalho foram avaliados os comportamentos de 7 medidores Altosonic V calibrados com 5 tipos de fluidos (oural, condensat, fuel, heavy fuel e água). Os fatores de calibração dos medidores foram submetidos a avaliações estatísticas e curvas de calibração foram ajustadas buscando identificar possíveis tendências de comportamento. Após supor-se que vazões e viscosidades teriam influência na aleatoriedade dos fatores, chegou-se à conclusão que, utilizando as calibrações de fábrica (fingerprint) do medidor, que cobrem toda a faixa de viscosidade e vazão de medição com a utilização do número de Reynolds, os limites requeridos por norma de erros para medição fiscal de são atendidos. Assim, sugere-se que as verificações periódicas do Altosonic V sejam feitas com o fluido disponível no laboratório de calibração, observando a coerência dos fatores obtidos nesta calibração e na calibração inicial, buscando o atendimento aos limites legais da aplicação. / [en] In Brazil, the measurement of oil is regulated by ANP and INMETRO. The Technical Regulation for Petroleum and Natural Gas requires that the oil flow meters be calibrated in conditions close to those found at the measurement site, both regarding the fluid (density and viscosity) and operational conditions (flow rate, pressure and temperature). It is very difficult to replicate all these conditions in national calibration facilities and expensive too. Thus, this study evaluated the behavior of 7 Altosonic V meters calibrated with 5 types of fluids (oural, condensat, fuel, heavy fuel and water). The calibration factors of the meters were subjected to statistical evaluation and calibration curves were fitted looking for possible behavior trends. Supposing that flow rates and viscosities would influence randomly the factors, a conclusion was reached that, by using the factory meter calibrations (fingerprint), that cover the entire measurement range of viscosity and flow rates, by using Reynolds number, the required by norm fiscal measurement error limits are met. Thus, it is suggested that periodic checks of Altosonic V could be made with the fluid available in the calibration facility, verifying the consistency of the factors obtained in this calibration and in the fingerprint, aimed at complying with the legal limits of the application.

Page generated in 0.0336 seconds