• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[pt] POTENCIALIDADE DO USO DE SONDA FOTOLUMINESCENTE BASEADA EM PONTOS QUÂNTICOS FUNCIONALIZADOS COM TIOURÉIA PARA DETERMINAÇÃO DE AMINAS BIOGÊNICAS / [en] POTENTIAL USE OF A PHOTOLUMINESCENT PROBE BASED ON THIOUREA-FUNCTIONALIZED QUANTUM DOTS FOR THE DETERMINATION OF BIOGENIC AMINES

EVELYN LEAL DE CARVALHO 20 August 2024 (has links)
[pt] Uma sonda fotoluminescente do tipo turn-on foi avaliada para a detecção de putrescina usando pontos quânticos de grafeno (GQDs). Diferentes nanopartículas de carbono fotoluminescentes foram preparadas usando a abordagem bottom-up, usando ácido cítrico como precursor, sozinho ou misturado com outros compostos contendo heteroátomos (N e/ou S) visando funcionalização da nanoestrutura. Observou- se que as nanopartículas preparadas com ácido cítrico e tioureia (GQDs-TU) apresentaram melhor perfil aumento da fotoluminescência (resposta analítica) na presença dessa amina biogênica. As condições experimentais foram ajustadas para o melhor perfil de resposta e para obter os parâmetros analíticos de mérito. No ensaio em batelada, a curva analítica normalizada (concentração L-L0 versus PUT) foi linear (R2 = 0,9498) até 90 mg L1 . O limite de quantificação (LOQ) foi de 15,1 mg L-1 e o limite de detecção (LOD) foi de 4,5 mg L-1 . Além disso, a estratégia proposta para a determinação indireta de putrescina foi adaptada para um sistema de análise por injeção em fluxo (FIA) a fim de aumentar a frequência analítica, diminuir os resíduos e automatizar a quantificação do analito. Após a otimização do ensaio, com a faixa linear cobrindo o intervalo até 50 mg L-1 (R2 = 0,9980), os valores de LOD e LOQ foram 3,0 mg L1 e 9,9 mg L-1 , respectivamente. / [en] A photoluminescent turn-on probe was evaluated for putrescine detection using graphene quantum dots (GQDs). Different photoluminescent carbon nanoparticles were prepared using a bottom-up approach, employing citric acid as a precursor, either alone or mixed with other compounds containing heteroatoms (N and/or S) for nanostructure functionalization. It was observed that the nanoparticles prepared with citric acid and thiourea (GQDs-TU) exhibited a more pronounced increase in photoluminescence (analytical response) when exposed to this biogenic amine. Experimental conditions were fine-tuned to optimize the response profile and obtain the analytical parameters of merit. In the batch assay, the normalized analytical curve (L-L0 concentration versus PUT) was linear (R2 = 0,9498) up to 90 mg L-1 . The limit of quantification (LOQ) was 15,1 mg L-1 and the limit of detection (LOD) was 4,5 g L-1 . Furthermore, the proposed strategy for the indirect determination of putrescine was adapted for a flow injection analysis (FIA) system to increase the analytical frequency, reduce waste, and automate analyte quantification. After optimization of the assay, with the linear range covering the range up to 50 mg L-1 (R2 = 0,9980), the LOD and LOQ values were 3,0 mg L-1 e 9,93 mg L-1 , respectively.

Page generated in 0.0414 seconds