• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 12
  • 12
  • 11
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

[en] BIOSORPTIVE FLOTATION OF NICKEL AND ALUMINUM USING A RHODOCOCCUS OPACUS STRAIN / [pt] FLOTAÇÃO BIOSORTIVA DE NÍQUEL E ALUMÍNIO USANDO A CEPA RHODOCOCCUS OPACUS

JAVIER ENRIQUE BASURCO CAYLLAHUA 25 August 2008 (has links)
[pt] A contaminação dos efluentes líquidos com metais pesados é uma ameaça ambiental comum, já que estes íons metálicos tóxicos encontram-se dissolvidos, atingindo eventualmente o topo da cadeia alimentar e assim se tornar um fator de risco para a saúde humana e ambiente. Diversos métodos de tratamento de efluentes como precipitação química, coagulação, floculação, flotação, troca iônica, filtração são empregadas para remoção dos metais pesados; estas possuem algumas desvantagens, quando empregados para tratamento de grandes volumes de efluentes líquidos com concentrações mínimas. Neste trabalho foi avaliada a cepa bacteriana Rhodococcus opacus como um potencial sorvente para a remoção de Ni(II) e Al(III) de soluções aquosas por flotação biossortiva, através de ensaios em batelada. O valor de pH adequado para a biossorção e flotação foi entorno de 5 para ambos metais. Os dados correspondentes à capacidade de captação do Rhodococcus opacus em função da concentração do níquel e do alumínio foram bem ajustados ao modelo de Redlich- Peterson e ao modelo de Temkin, respectivamente. As capacidades de captação máxima obtidas foram: 7,63 e 41,59 mg.g-1 para o níquel e alumínio, nesta ordem. A cinética de biossorção para o níquel e alumínio foi modelada pela equação de pseudosegunda ordem. Foram avaliadas também as propriedades superficiais do microorganismo antes e após a interação dos metais para poder determinar os possíveis mecanismos implicados na biossorção mediante medições eletrocinéticas e espectroscopia de infravermelho. Na flotação biossortiva, verificou-se que o microorganismo apresenta propriedades muito promissoras como coletor e espumante, obtendo-se porcentagens de remoção de 90% e 95% para o níquel e alumínio, respectivamente. Os resultados apresentados mostram que o Rhodococcus opacus apresenta características adequadas no que tange a flotação biossortiva para remoção de metais. / [en] Heavy metal pollution of wastewater is a common environmental threat, since the toxic metal ions dissolved can eventually reach the top of the food chain and thus, become a risk factor for people`s health. Various methods of effluent treatment such as chemical precipitation, coagulation, flocculation, flotation, ionic exchange and filtration are commonly used for heavy metals removal from liquid streams; these techniques possess some disadvantages, particularly, inadequate metals removal when applied to dilute effluents on a large scale basis. In this work, a Rhodococcus opacus strain was evaluated as a potential biosorbent for Ni(II) and Al(III) removal from aqueous solution for biosorptive flotation process, trough experimental batch experiments. The pH value suitable for biosorption and flotation was around 5 for both metals. The data pertaining to the uptake capacity of the Rhodococcus opacus as a function of the nickel and aluminum ion concentration had been fitted to the Redlich- Peterson and Temkin isotherm model, respectively; where the maximum uptake capacities obtained were: 7,63 and 41,59 mg.g-1 for nickel and aluminum, respectively. The nickel and aluminum kinetics biosorption were modeled using a pseudo second order rate equation. The superficial properties of the microorganism had also been evaluated before and after the interaction with the metals, to be able to find out the possible mechanism implied in the biosorption; by means of the electro kinetic measurements (Zeta Potential) and Infrared spectroscopy (FTIR). In the biossorptive flotation, it was verified that the microorganism presents excellent properties a collector and foaming agent, reaching 90% and 95% removal of nickel and aluminum. The results of this work showed that the Rhodococcus opacus has a strong and feasible engineering potential for heavy metals removal by biossorptive flotation.
12

[pt] AVALIAÇÃO DA UTILIZAÇÃO DE LODO ATIVADO E DO PROCESSO DE OZONIZAÇÃO NA REMEDIAÇÃO DE ÁGUAS SUBTERRÂNEAS ORIUNDAS DE SISTEMAS PUMP AND TREAT / [en] EVALUATION OF ACTIVATED SLUDGE USE AND OZONATION PROCESS IN REMEDIATION OF GROUNDWATER DERIVED FROM PUMP AND TREAT SYSTEMS

RAPHAEL GONCALVES RIEBOLDT OLIVEIRA 19 October 2016 (has links)
[pt] Em função do crescente número de área contaminadas, identificadas nos grandes centros urbanos, é de crucial importância a evolução e o desenvolvimento dos processos relacionados ao tratamento destes locais, visando reduzir os riscos à saúde humana e ao meio ambiente, associados à presença dos contaminantes no meio subterrâneo. A presente dissertação tem como objetivo principal avaliar a eficiência de diferentes técnicas processuais, que poderiam ser aplicadas no tratamento de águas subterrâneas contaminadas, incluindo a ozonização e o uso de lodo ativado. Para isso, foram realizados ensaios de tratabilidade no laboratório do Institute of Sanitary and Environmental Engineering, da Universidade Técnica de Braunschweig, na Alemanha, os quais foram divididos em 3 etapas. A primeira etapa consistiu de um tratamento de caráter biológico, utilizando apenas o lodo ativado, coletado em estações de tratamento de efluentes sanitários, para a degradação de compostos orgânicos presentes em efluentes, artificiais e industriais, que simularam um efluente oriundo de um sistema de tratamento de uma área contaminada. A segunda etapa utilizou como técnica de tratamento, para o mesmo efluente, a ozonização, promovendo assim a oxidação química dos contaminantes. Por fim, foi utilizada uma combinação dos dois processos, sendo realizada a ozonização do efluente antes da degradação biológica. O objetivo desta etapa foi avaliar o incremento da biodegradabilidade do efluente por meio da ozonização. Os resultados obtidos indicaram, além da remoção da cor do efluente, uma efetiva redução dos valores de DQO, quando combinadas as duas técnicas de tratamento, sugerindo que a combinação das mesmas pode ser uma boa alternativa para o tratamento de efluentes de alta complexidade. / [en] Given the growing number of contaminated sites identified in large urban areas, it is of crucial importance the evolution and development of treatment processes for these sites, targeting the reduction of environmental and human health risks related to soil and groundwater contamination. The main goal of this dissertation is to evaluate the efficiency of various processing methods that could be applied in the treatment of contaminated groundwater, including the ozonation and activated sludge utilization. For that, jar tests were conducted in the laboratory of Institute of Sanitary and Environmental Engineering, at Braunschweig Technical University, in Germany, in three steps. The first step performed a biological treatment utilizing the activated sludge only which was collected from sewage treatment plants for the biodegradation of organic compounds present in effluents, both artificial and industrial, which simulated the effluent from a contaminated site treatment system. The second step utilized as treatment method, for the same effluent, an ozonation process, promoting the chemical oxidation of the contaminants. At last, a combination of both methods was tested where the ozonation was done prior to the biodegradation. The objective of this step was to evaluate the additional results of the biodegradation of the effluent when an ozonation process is done first. The results showed, in addiction of the color removal from the effluent, a larger reduction of DQO when both techniques are combined, suggesting that the combination can be a good alternative for treatment of high complexity wastewater.

Page generated in 0.0394 seconds