[pt] AVALIAÇÃO DO EFEITO DO ESGOTAMENTO DE RECURSOS DE CONTROLE SOBRE A ESTABILIDADE DE TENSÃO E CÁLCULO DE AÇÕES DE CONTROLE PREVENTIVAS / [en] EVALUATION OF THE EFFECT OF CONTROL RESOURCES EXHAUSTION ON VOLTAGE STABILITY AND CALCULATION OF PREVENTIVE CONTROL ACTIONS

09 March 2021 (has links)
[pt] Em todos os sistemas de potência, inclusive o brasileiro, verificam-se os níveis de tensão nos barramentos e de corrente nos ramos de transmissão na presença de contingências durante a operação em tempo real. A lista de contingências inclui a perda de qualquer ramo de transmissão, a perda de alguns pares de ramos e, de menor importância, a perda de geração. As condições de estabilidade de tensão também são checadas nesse momento. Esse trabalho simula eventos em que há perda do controle de tensão devido ao esgotamento da fonte controladora em todas as barras de tensão controlada da rede e verifica seus efeitos sobre a estabilidade de tensão. As simulações realizadas incluem também o evento em que há perda de capacidade de aumentar a geração de potência ativa em todos os geradores. Um método de ordenação pelo grau de severidade do evento sobre a estabilidade de tensão é empregado. Além disso, aproveitam-se os resultados obtidos e determinam-se as tensões e gerações mais influentes sobre a estabilidade de tensão de uma certa barra. Com a finalidade de aumentar a margem de potência dessa certa barra, calculam-se ações de controle preventivas, isto é variações nas tensões e, se necessário, nas gerações ativas. / [en] In all power systems, including the Brazilian one, it is common to check the voltage levels in busbars and current in the transmission branches in presence of contingencies during the real-time operation. The list of contingencies includes loss of any transmission lines, loss of some pairs of branches and, less importantly, loss of power generation. Voltage stability conditions are also checked at that time. This work simulates events in which there is loss of voltage control due to the exhaustion of the control source in all voltage-controlled busbars and verifies its effects on voltage stability. Simulations also include the event which shows loss of capacity to increase the active power generation in all generators. A ranking method is employed to order events by their degree of severity over voltage stability. In addition, the obtained results are used to determine the most influential voltages and generators over the voltage stability of a specific busbar. In order to increase the margin of power of this certain busbar, preventive control actions are calculated by keeping track of variations in voltage and, when necessary, in active power generations.
2

[en] RELATION VQ IN THE EVALUATION OF VOLTAGE STABILITY / [pt] RELAÇÃO VQ NA AVALIAÇÃO DA ESTABILIDADE DE TENSÃO

15 September 2020 (has links)
[pt] O fenômeno de estabilidade de tensão é um problema associado ao fluxo de potência ativa e reativa nas linhas de transmissão. A manifestação mais conhecida do fenômeno é a existência de uma máxima carga que pode ser alimentada pela rede. Outra possibilidade é a existência de uma máxima injeção de potência ativa e reativa fornecida por geradores e compensadores. A curva QV possibilita o cálculo da margem Q, que corresponde à distância entre o caso-base e ponto de fronteira da curva. A margem Q, supostamente, é um índice para avaliação da estabilidade do sistema, determinando uma operação normal quando a inclinação da curva é positiva. O método da matriz D também fornece a relação Q e V de cada barra, avaliando, supostamente, as condições de estabilidade do sistema. Nesta dissertação foi proposta a análise desses dois índices, com o objetivo de explicitar as premissas, similaridades e diferenças das duas maneiras de se calcular a relação VQ. E assim, avaliar e identificar possíveis resultados não coerentes. / [en] The phenomenon of voltage stability is a problem associated with active and reactive power flow in transmission lines. The best-known manifestation of the event is the existence of a maximum load that can be supplied by the grid. Another possibility is the existence of a maximum injection of active and reactive power provided by generators and compensators. The QV curve enables the calculation of the Q margin, which corresponds to the distance between the base case and the curve s inflection point. The Q margin, supposedly, is an index for evaluating the system stability, consisting of normal operation when the slope of the curve is positive. The matrix method D also provides the relation Q and V of each bar evaluating, supposedly, conditions of system stability. In this dissertation, an analysis of these two indices was proposed to clarify the assumptions, similarities, and differences between the two ways of calculating the VQ relation. And so, evaluate and identify possible non-coherent results.
3

[en] CRITERIA FOR DETERMINATION OF THE VOLTAGE STABILITY MARGIN FROM THE PERSPECTIVE OF THE OPERATION / [pt] CRITÉRIO PARA DETERMINAÇÃO DA MARGEM DE ESTABILIDADE DE TENSÃO SOB A PERSPECTIVA DA OPERAÇÃO

AMANDA ALVARENGA DIAS 12 November 2020 (has links)
[pt] Atualmente, o fenômeno de instabilidade de tensão representa uma das principais barreiras à operação estável das redes de energia elétrica, que tendem a crescer e a se tornarem cada vez mais interconectadas. A dificuldade de manter um perfil de tensão aceitável aumenta substancialmente e a estabilidade de tensão na operação dos sistemas elétricos deve ser preservada ao máximo, a fim de evitar os graves efeitos que a sua perda acarreta ao sistema. Esta dissertação atua na operação do sistema de energia elétrica, mais especificamente na área de operação em tempo real, onde é importante se conhecer a proximidade da condição operativa atual do sistema daquela que corresponde ao ponto crítico de estabilidade. Tal conhecimento permite que ações preventivas sejam realizadas no sentido de se evitar a instabilidade. O objetivo do trabalho é, a partir da comparação entre a margem sistêmica e a margem nodal, calculadas respectivamente pelo Fluxo de Potência Continuado e pelo método da Matriz D, determinar um critério para a margem de capacidade de carga, do ponto de vista de estabilidade de tensão, para a operação segura. No evento de cada contingência, calcula-se o maior crescimento de carga (margem), a partir do caso base, onde os índices nodais ainda são positivos. Define-se como margem mínima a menor dessas margens. A abordagem proposta foi avaliada através dos resultados obtidos com uma versão modificada do chamado sistema Nordic32. / [en] Currently, the phenomenon of voltage instability represents one of the main barriers to the stable operation of electric power networks, which tend to grow and become increasingly interconnected. The difficulty of maintaining an acceptable voltage profile increases substantially and the voltage stability in the operation of the electrical systems must be preserved to the maximum extent in order to avoid the serious effects that its loss entails on the system. This dissertation works in the operation of the electrical system, more specific in the area of operation in real time, where it is important to know the proximity of the operational condition of the current system that corresponds to the critical point of stability. Such knowledge allows preventive actions to be taken in order to avoid instability. The determination of appropriate margins for the various activities carried out in the electric power systems is not a trivial task, motivating the development of this dissertation. The objective of the work is from the comparison between a systemic margin and the nodal margin, calculated respectively by the Continued Power Flow and by the Matrix D method, to determine a criterion for the load capacity margin from the voltage stability point of view, for safe operation. In the event of each contingency, the largest growth (margin) is calculated from the base case, where the nodal indices are still positive. The smallest margin is defined as the minimum margin. The proposed approach was evaluated through the results obtained with a modified version of the so-called Nordic32 test system.
4

[en] IDENTIFICATION OF CRITICAL BUSES FROM THE VOLTAGE STABILITY VIEWPOINT / [pt] IDENTIFICAÇÃO DAS BARRAS CRÍTICAS DO PONTO DE VISTA DE ESTABILIDADE DE TENSÃO

02 May 2016 (has links)
[pt] O surgimento do fenômeno de estabilidade de tensão na operação dos sistemas elétricos motivou centenas de pesquisadores a desenvolverem métodos que permitam detectar a proximidade à instabilidade de tensão, com eficiência computacional, e tomar medidas acertadas para garantir a operação confiável e segura. Neste trabalho são utilizados e comparados diferentes métodos associados à análise de estabilidade de tensão. Para testes, foram utilizados vários sistemas sob diferentes níveis de carregamento, desde carga leve até o máximo carregamento, este obtido a partir do algoritmo de fluxo de potência continuado. O objetivo é localizar as barras críticas, isto é, aquelas onde não se pode aumentar a injeção de potência e que impedem o crescimento da carga do resto do sistema. / [en] The rise of voltage stability phenomenon in the operation of the electrical systems motivated hundreds of researchers to develop methods that allow them to detect the proximity to voltage instability, with computational efficiency, and take the right steps to ensure reliable and safe operation. This work used and compared different methods associated with the voltage stability analysis. For the tests were used various systems under different levels of loading, from light load to maximum load, this point obtained from the continuous power flow algorithm. The goal is to find the critical buses, that is, those at which the power injection cannot be increased and that avoid the growth of load in the rest of the system.
5

[pt] REFORÇOS DAS CONDIÇÕES DE ESTABILIDADE DE TENSÃO VIA ALGORITMOS GENÉTICOS / [en] REINFORCEMENT OF VOLTAGE STABILITY CONDITIONS BY GENETIC ALGORITHMS

ARTHUR MASSARI FILHO 04 October 2021 (has links)
[pt] Nos sistemas de potência ao redor do mundo, inclusive o brasileiro, são feitas as medições dos níveis de tensão nos barramentos e a corrente nos ramos de transmissão durante algum tipo de contingência em tempo real. A lista de contingências inclui: a perda de qualquer ramo de transmissão, a perda de alguns pares de ramos e, de menor importância, a perda de geração. Nesse momento, também são avaliadas as condições de estabilidade de tensão. A inclusão na lista de contingências de perda de controle de tensão devido ao esgotamento da fonte controladora (gerador, compensador, tap de LTC) em todas as barras de tensão controlada e também a perda de capacidade de aumentar/diminuir a geração de potência ativa em todos os geradores da rede permite identificar o grau de sensibilidade de cada grandeza contingenciada sobre a margem de estabilidade de tensão. Depois de feita a análise dos esgotamentos, é determinado em ordem decrescente as tensões e as gerações que mais influenciam a margem de estabilidade de tensão de uma determinada barra. Esse resultado indica as direções do movimento das grandezas. Portanto, para melhorar a margem da barra crítica, devem-se calcular ações de controle, ou seja, variar a tensão e/ou a potência ativa dos geradores, encontrando assim um novo ponto de operação. Esse novo ponto de operação deve ser buscado através de algoritmos genéticos. O desvio mínimo quadrático em relação ao ponto de operação do caso base deve ser observado, ou seja, busca-se um novo ponto de operação que não seja muito distante ao caso base. No algoritmo genético, a tensão dos geradores é a variável; a sua variação é discreta em degraus de 0,01 pu (em módulo). Também há casos em que potência ativa dos geradores será variável do GA e tendo suas variações em degraus de 5 porcento em módulo em relação ao caso base. São realizados diversos testes para encontrar o novo ponto de operação, buscando encontrar os menores desvios possíveis enquanto melhora-se a margem de potência. No primeiro sistema utilizado (CEPEL-34) duas configurações dentre os testes feitos para o GA se sobressaem das demais e por isso são usadas para outro sistema (Nórdico). Em ambos os sistemas o objetivo inicial é cumprido. / [en] Power systems around the world, including the Brazilian one, measure the voltage levels on the buses and the current in the transmission branches during some type of contingency in real time. The list of contingencies includes: the loss of any branch of transmission, the loss of some pairs of branches and, of less importance, the loss of generation. At that time, the voltage stability conditions are also evaluated. The inclusion in the list of contingencies of loss of voltage control due to the exhaustion of the controlling source (generator, compensator, LTC tap) in all controlled voltage bars and also the loss of capacity to increase / decrease the generation of active power in all generators in the network make it possible to identify the degree of sensitivity of each contingent quantity on the voltage stability margin. After the analysis of the exhausts, the tensions and generations that most influence the voltage stability margin of a given bar are determined in decreasing order. This result indicates the directions of movement of the quantities. Therefore, to improve the margin of the critical bar, control actions must be calculated, that is, vary the voltage and / or the active power of the generators, thus finding a new point of operation. This new point of operation must be sought through genetic algorithms. The minimum quadratic deviation in relation to the operating point of the base case must be observed, that is, a new operating point that is not far from the base case is sought. In the genetic algorithm, the voltage of the generators is the variable; its variation will be discrete in steps of 0.01 pu (in module). There will also be cases in which the active power of the generators will be variable in the GA and having their variations in steps of 5 percent in module in relation to the base case. Several tests are carried out to find the new operating point, seeking to find the smallest possible deviations while improving the power margin. In the first system used (CEPEL-34) two configurations among the tests made for GA stand out from the others and therefore replicated to another system (Nordic). In both systems the initial objective is fulfilled.