• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[pt] AVALIAÇÃO DA CONFIABILIDADE DE SISTEMAS DE GERAÇÃO COM FONTES RENOVÁVEIS VIA TÉCNICAS DE SIMULAÇÃO MONTE CARLO E ENTROPIA CRUZADA / [en] RELIABILITY ASSESSMENT OF GENERATING SYSTEMS WITH RENEWABLE SOURCES VIA MONTE CARLO SIMULATION AND CROSS ENTROPY TECHNIQUES

RICARDO MARINHO SILVA FILHO 04 October 2021 (has links)
[pt] A avaliação de confiabilidade da capacidade de geração é extremamente útil em diversos estudos de planejamento da expansão, na avaliação dos riscos relacionados ao dimensionamento da reserva operativa e também na programação da manutenção de unidades geradoras. O principal objetivo é avaliar se uma determinada configuração de unidades de geração atende de forma aceitável à carga do sistema, assumindo que os equipamentos de transmissão sejam totalmente confiáveis e sem limitações de capacidade. Na última década, a inserção de fontes renováveis nos sistemas elétricos de potência tem crescido de forma acentuada, na grande maioria dos países desenvolvidos como também em desenvolvimento. As flutuações de suas capacidades de geração se tornaram parte da complexidade do problema de planejamento e operação de redes elétricas, uma vez que dependem das condições ambientais em que foram instaladas. Além disso, representações detalhadas da carga têm se tornado uma preocupação a mais de muitos planejadores, tendo em vista as análises de risco ao atendimento da demanda nessas redes. Novos modelos e ferramentas computacionais devem ser desenvolvidos para tratar dessas variáveis principalmente com dependência espaço-temporal. Esta dissertação apresenta diversos estudos para avaliar a confiabilidade da capacidade de sistemas de geração via simulação Monte Carlo quasi-sequencial (SMC-QS), considerando fontes de geração e carga com forte dependência espaço-temporal. Esta ferramenta é escolhida devido à sua fácil implementação computacional e capacidade de simular eventos cronológicos. A técnica de redução de variância denominada amostragem por importância baseada no método Cross Entropy (CE) foi utilizada em conjunto com a SMC-QS. As simulações terão como base o sistema teste IEEE-RTS 96, o qual é adequada-mente modificado para incluir fontes renováveis eólicas e hídricas. Portanto, o principal objetivo desta dissertação é definir a melhor maneira de lidar com as séries temporais representativas da geração renovável e carga, nos diferentes estágios do método SMC-QS via CE, de modo a maximizar sua eficiência computacional. Vários testes de simulação são realizados com o sistema IEEE-RTS 96 modificado e os resultados obtidos são amplamente discutidos. / [en] The reliability evaluation of the generating capacity is extremely useful in several expansion planning studies, in the assessment of risks related to the requirements of the operating reserve and also in the scheduling of maintenance of generating units. The main objective is to assess whether a given generating configuration meets the system load in an acceptable manner, assuming that the transmission equipment is completely reliable and without capacity limitations. In the last decade, the insertion of renewable sources in electrical power systems has grown markedly, in the vast majority of developed and developing countries. Fluctuations in their generation capacities have become part of the complexity of the problem of planning and operating electrical networks, since they depend on the environmental conditions in which they are installed. In addition, detailed representations of the load have become a concern among many planners, given the risk analyzes to meet demand in these networks. New computational models and tools must be developed to deal with these variables mainly with space-time dependence. This dissertation presents several studies to evaluate the reliability of the capacity of generation systems via quasi-sequential Monte Carlo simulation (QS-MCS), considering generation and load sources with strong space-time dependence. This tool is chosen due to its easy computational implementation and the ability to simulate chronological events. The variance reduction technique named importance sampling based on the cross-entropy (CE) method is used in conjunction with the QS-MCS. The simulations will be carried out with the IEEE-RTS 96 test system, which is adequately modified to include renewable wind and hydro sources. Therefore, the main objective of this dissertation is to define the best way to deal with the time series representing the renewable generation and load, in the different stages of the SMC-QS method via CE, in order to maximize its computational efficiency. Several simulation tests are performed with the modified IEEE-RTS 96 system and the obtained results are widely discussed.
2

[en] OPERATING RESERVE ASSESSMENT IN MULTI-AREA SYSTEMS WITH RENEWABLE SOURCES VIA CROSS ENTROPY METHOD / [pt] PLANEJAMENTO DA RESERVA OPERATIVA EM SISTEMAS MULTIÁREA COM FONTES RENOVÁVEIS VIA MÉTODO DA ENTROPIA CRUZADA

JOSÉ FILHO DA COSTA CASTRO 11 January 2019 (has links)
[pt] A reserva girante é a parcela da reserva operativa provida por geradores sincronizados, e interligados à rede de transmissão, aptos a suprir a demanda na ocorrência de falhas de unidades de geração, erros na previsão da demanda, variações de capacidade de fontes renováveis ou qualquer outro fator inesperado. Dada sua característica estocástica, essa parcela da reserva operativa é mais adequadamente avaliada por meio de métodos capazes de representar as incertezas inerentes ao seu dimensionamento e planejamento. Por meio do risco de corte de carga é possível comparar e classificar distintas configurações do sistema elétrico, garantindo a não violação dos requisitos de confiabilidade. Sistemas com elevada penetração de fontes renováveis apresentam comportamento mais complexo devido ao aumento das incertezas envolvidas, à forte dependência de fatores energético-climáticos e às variações de capacidade destas fontes. Para avaliar as correlações temporais e representar a cronologia de ocorrência dos eventos no curto-prazo, um estimador baseado na Simulação Monte Carlo Quase Sequencial é apresentado. Nos estudos de planejamento da operação de curto-prazo o horizonte em análise é de minutos a algumas horas. Nestes casos, a ocorrência de falhas em equipamentos pode apresentar baixa probabilidade e contingências que causam corte de carga podem ser raras. Considerando a raridade destes eventos, as avaliações de risco são baseadas em técnicas de amostragem por importância. Os parâmetros de simulação são obtidos por um processo numérico adaptativo de otimização estocástica, utilizando os conceitos de Entropia Cruzada. Este trabalho apresenta uma metodologia de avaliação dos montantes de reserva girante em sistemas com participação de fontes renováveis, em uma abordagem multiárea. O risco de perda de carga é estimado considerando falhas nos sistemas de geração e transmissão, observando as restrições de transporte e os limites de intercâmbio de potência entre as diversas áreas elétricas. / [en] The spinning reserve is the portion of the operational reserve provided by synchronized generators and connected to the transmission network, capable of supplying the demand considering generating unit failures, errors in load forecasting, capacity intermittency of renewable sources or any other unexpected factor. Given its stochastic characteristic, this portion of the operating reserve is more adequately evaluated through methods capable of modeling the uncertainties inherent in its design and planning. Based on the loss of load risk, it is possible to compare different configurations of the electrical system, ensuring the non-violation of reliability requirements. Systems with high penetration of renewable sources present a more complex behavior due to the number of uncertainties involved, strong dependence of energy-climatic factors and variations in the capacity of these sources. In order to evaluate the temporal correlations and to represent the chronology of occurrence of events in the short term, an estimator based on quasi-sequential Monte Carlo simulation is presented. In short-term operation planning studies, the horizon under analysis is from minutes to a few hours. In these cases, the occurrence of equipment failures may present low probability and contingencies that cause load shedding may be rare. Considering the rarity of these events, risk assessments are based on importance sampling techniques. The simulation parameters are obtained by an adaptive numerical process of stochastic optimization, using the concept of Cross Entropy. This thesis presents a methodology for evaluating the amounts of spinning reserve in systems with high penetration of renewable sources, in a multi-area approach. The risk of loss of load is estimated considering failures in the generation and transmission systems, observing the network restrictions and the power exchange limits between the different electric areas.

Page generated in 0.0412 seconds