• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] QUANTIFICATION OF AUSTENITE-MARTENSITE IN LOW ALLOY STEEL BY IMAGE ANALYSIS / [pt] QUANTIFICAÇÃO POR MICROSCOPIA DIGITAL DO MICROCONSTITUINTE AUSTENITA-MARTENSITA EM AÇO DE BAIXA LIGA

JULIO DAMIAN SUNI MAMANI 05 May 2014 (has links)
[pt] O objetivo deste trabalho foi desenvolver uma metodologia para quantificação, por microscopia, do microconstituinte Austenita-Martensita (AM) em um aço de alta resistência e baixa liga (ABRL) da classe API5LX80. Foram obtidas imagens de Microscopia Ótica (MO) em campo claro e Eletrônica de Varredura (MEV), nos modos de elétrons secundários (SE) e retroespalhados (BSE). As imagens foram quantificadas por Processamento e Análise Digital de Imagens (PADI) e os resultados dos dois tipos de microscopia foram comparados. O principal desafio foi discriminar AM em meio a uma microestrutura multifásica complexa, com frações variadas de ferrita, bainita e do próprio AM. Para revelar a presença de AM foram testadas diferentes sequências de ataques químicos e eletrolíticos. Os resultados demostraram que o ataque químico misto, acrescentando um passo Lepera modificado gerou uma melhora acentuada do contraste em imagens de MO e de MEV no modo BSE. Imagens de MEV no modo SE apresentaram problemas de borda devido à posição do detector de elétrons, o que impediu a correta discriminação das regiões de AM. No modo BSE, a tensão de aceleração foi reduzida para 5 kV, para reduzir a penetração do feixe de elétrons e aumentar o contraste devido à fina camada de AM. Estas imagens foram filtradas para reduzir ruído e segmentadas por limiar simples para quantificar o AM. Nas imagens coloridas de MO, o AM foi segmentado por limiares nos espaços de cor RGB e HSB e em seguida foi quantificado. Utilizando Microscopia Co-Localizada (MCL) foram obtidas imagens de campos idênticos no MEV e no MO, permitindo comparar as técnicas. Mostrou-se que, no mesmo aumento, a microscopia ótica tende a subestimar a fração de AM quando comparada à microscopia eletrônica de varredura, no modo BSE. / [en] This dissertation proposed the development of a quantification method, by microscopy, of the microconstituent Martensite-Austenite (MA) in a High Strength Low Alloy (HSLA) steel of the API5LX80 class. Images were obtained by Optical Microscopy (OM) and Scanning Electron Microscopy (SEM), in secondary electron (SE) and backscattered electron (BSE) modes. Digital Image Processing and Analysis (IA) was employed to process and quantify the acquired images and compare the results of the two types of microscopy. The main challenge was to discriminate the MA amidst a complex multiphase microstructure with varying fractions of ferrite, bainite and MA itself. To reveal the MA different chemical and electrolytic etching sequences were tested. The results showed that a mixed combination with an extra step of modified LePera etchant issued the best contrast for both OM and BSE mode SEM. SEM images in SE mode showed edge problems due to the location of the electron detector, what prevented the correct discrimination of MA regions. The accelerating voltage in the BSE mode was reduced to 5 kV which in turn decreased beam penetration and increase contrast due to the thin MA layer. These images were filtered to reduce noise and segmented by a simple threshold to quantify MA. In the color OM images MA was segmented by thresholds in the RGB or HSB color spaces and subsequently quantified. Employing Co-Site Microscopy images of identical fields acquired by OM and SEM, a direct comparison of the techniques was allowed. It was show that, for the same magnification, optical microscopy tends to underestimate the MA fraction when compared to electron microscopy in BSE mode.

Page generated in 0.0462 seconds