• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] AN OPTIMIZATION-BASED EQUIVALENT DC POWER FLOW MODEL FOR NETWORK REDUCTION / [pt] MODELO EQUIVALENTE DE FLUXO DE POTÊNCIA CC PARA REDUÇÃO DE REDES BASEADO EM OTIMIZAÇÃO

RAUL RIBEIRO DA SILVA 05 October 2021 (has links)
[pt] O uso da representação de modelos completos em estudos de sistemas de potência pode levar a indesejados níveis de esforço computacional e imprecisão devido às incertezas e complexidade dos sistemas modernos. Para endereçar este problema de tratabilidade, métodos de redução de redes buscam criar um modelo simplificado, com dimensão reduzida, de um dado sistema de potência. As técnicas atuais consideram apenas um ponto de operação no processo de redução falhando em desempenho para uma grande variedade de condições operativas. Adicionalmente, a solução para o fluxo de potência CA (não linear) apresenta pior performance computacional, mas melhor precisão quando comparada à sua contraparte linear (solução para fluxo de potência CC). Infelizmente, a aproximação do fluxo de potência CC desconsidera a perda de energia nas linhas e os efeitos das não linearidades devido as mudanças nos níveis de tensão e potências reativas no sistema. Neste contexto, um novo modelo de fluxo de potência equivalente baseado em otimização é proposto. Assim, para superar as limitações relativas a performance computacional e as imprecisões para multiplos cenários operativos, utilizamos o modelo proposto para produzir um método de redução baseado no fluxo CC, que apresenta bom desempenho em variados pontos operativos. Neste caso, a solução de um problema de otimização linear, que considera múltiplos cenários de fluxo CA ou medições do sistema, determina os parâmetros da rede equivalente. Para garantir a precisão do modelo, consideramos um conjunto de cargas artificiais para representar o desbalanço entre os cenários observados e a resposta da rede equivalente. Estas cargas artificiais são funções polinomiais do ponto operativo do sistema, e seus coeficientes são cootimizados com os parâmetros da rede reduzida. A Analise de Componentes Pincipais é utilizada para extrair as componentes relevantes do vetor de cargas que define um ponto operativo, reduzindo a dimensão do modelo, e melhorarando o desempenho out–of–sample. A metodologia é testada contra o equivalente Ward para diferentes condições operativas. Casos de estudo com dados gerados são apresentados com o objetivo de analisar a capacidade de generalização do modelo para diferentes níveis de ruído. Por fim, um caso de estudo com perfís de carga realísticos oriundos de uma companhia de distribuição brasileira é conduzido no sistema de teste IEEE 118–Bus. / [en] The use of full model representation in power system studies may lead to undesirable levels of computational burden and inaccuracy due to modern system complexities and uncertainties. To address the tractability issue, network reduction methods aim to create a simplified model, with reduced dimension, of a given power system. Current techniques consider only one operating point in their reduction process, falling short in properly performing for a wide range of operating conditions. Additionally, a nonlinear AC power flow solution features worse computation performance, but better accuracy when compared against its linearized counterpart (DC power flow solution). Unfortunately, the DC power flow approximation disregards the line losses and nonlinear effects due to changes in voltage levels and reactive power. In this context, we propose a novel optimization–based framework to create equivalent power flow models. Thus, to overcome the computational performance limitations and imprecision for multiple operating scenarios, we use the proposed framework to produce a DC–based network reduction method that performs well in many operating points. The solution of a linear optimization problem, which considers multiple AC power flow scenarios or network measurements, determines the equivalent network parameters. To ensure modeling accuracy, we consider a set of artificial dynamic loads to represent the mismatch between observed scenarios and the response of the equivalent. These artificial loads are polynomial functions of the operating point, and their coefficients are co-optimized with the reduced network parameters. Principal Component Analysis (PCA) is used to extract the relevant components of the load vector defining the operating point, reducing the equivalent model dimensionality, and improving out–of–sample performance. We test the methodology against traditional Ward equivalent for different operating conditions. We present case studies with generated data to investigate the model generalization capability for different noise levels. Finally, we conduct a case study based on realistic load profiles from a Brazilian distribution company within the IEEE 118–Bus test system.
2

[en] USING ELECTRIC CIRCUIT EQUIVALENTS FOR VOLTAGE STABILITY ASSESSMENT / [pt] UTILIZAÇÃO DE CIRCUITOS ELÉTRICOS EQUIVALENTES NA AVALIAÇÃO DAS CONDIÇÕES DE ESTABILIDADE DE TENSÃO

LAURA CRISTINA PANIAGUA PALACIO 08 June 2015 (has links)
[pt] O surgimento do fenômeno de estabilidade de tensão na operação dos sistemas elétricos motivou centenas de pesquisadores a desenvolverem métodos que permitam detectar a proximidade à instabilidade de tensão, com eficiência computacional, e tomar medidas acertadas para garantir a operação confiável e segura. Neste trabalho são analisados diferentes métodos que permitem transformar sistemas de grande porte em circuitos simples: o circuito equivalente entre geradores e cargas, baseado no cálculo de correntes de curto-circuito, na técnica de redução de rede pela eliminação de barras intermediárias e no equivalente de Thévenin. É analisada a utilização destes equivalentes na avaliação das condições de estabilidade de tensão com sistemas-testes de 3 e 4 barras. Através de diferentes testes verificou-se que o circuito equivalente entre geradores e cargas e a técnica de redução de rede não podem ser usados para o cálculo de índices de avaliação das condições de estabilidade de tensão, enquanto que, usando circuito equivalente de Thévenin encontrou-se um método que funciona corretamente para barra de carga terminal, barra não-terminal e barra de tensão controlada por gerador. / [en] The emergence of voltage stability phenomenon in the operation of power systems has motivated hundreds of researchers to develop methods to detect the proximity to voltage instability, with computational efficiency and to take all necessary and appropriate measures to ensure reliable and safe operation. In this work, different methods that allow transforming large systems into simple circuits were analyzed, such as the equivalent circuit between generators and loads, based on the calculation of short-circuit currents; the network reduction technique for eliminating intermediate buses; and the Thévenin equivalent. The application of these equivalents on voltage stability assessment of 3 and 4 bus testing systems were extensively tested. At the end, it was verified that that the equivalent circuit between the generator and load, and the network reduction technique, cannot be used for calculating the voltage stability conditions evaluation indexes. However, using Thévenin equivalent circuit, it was found a proper method, which works correctly for terminal buses, transit buses and voltage-controlled buses.

Page generated in 0.0454 seconds