• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] DESIGN OF EXPERIMENTS TO ANALYZE THE INFLUENCE OF WATER ON THE UNCERTAINTY OF OIL FLOW MEASUREMENT WITH ULTRASONIC METERS / [pt] PLANEJAMENTO DE EXPERIMENTOS PARA ANÁLISE DA INFLUÊNCIA DO TEOR DE ÁGUA NA INCERTEZA DE MEDIÇÃO DE VAZÃO DE ÓLEO COM MEDIDORES ULTRASSÔNICOS

FILIPE CARELI DE ALMEIDA 20 February 2018 (has links)
[pt] O objetivo desta dissertação é avaliar a influência do teor de água e do fator do medidor na incerteza de malhas fiscais de medição de óleo utilizando medidores ultrassônicos. A motivação deste trabalho advém do fato do Regulamento Técnico de Medição de Petróleo e Gás Natural (RTM) existente limitar quais metodologias podem ser utilizadas para realizar a análise de teor de água e qual a incerteza máxima permitida para a malha de medição na qual esta se insere, porém não define a incerteza desta, havendo o risco de se adotar um dos métodos de análise permitidos e, ainda assim, a incerteza de medição da malha ultrapassar a definida pela legislação. Além disso, o RTM adota um critério de repetibilidade para a validação das calibrações dos medidores ultrassônicos, portanto avalia-se também a influência deste na incerteza da malha. A metodologia utilizada foi o planejamento de experimentos, utilizando superfície de resposta. Os resultados demonstram que é possível simular a influência da incerteza da análise da água e do fator do medidor na incerteza da malha. Por fim, as conclusões demonstram que as médias atualmente encontradas para incerteza do teor de água são adequadas para manter a incerteza da malha dentro da permitida pelo RTM, porém com pouca variação pode-se exceder este limite; a influência da incerteza do fator do medidor foi inferior ou similar à do teor de água e, por fim, sugere-se a adoção de um critério limite de incerteza ao invés de um critério de repetibilidade para os medidores ultrassônicos. / [en] The aim of this dissertation is to evaluate the influence of water content dissolved in crude oil and the meter factor on the uncertainty of the fiscal oil metering using ultrasonic flow meters. The development of this work is motivated by the fact that the Technical Regulation for the Measurement of Oil and Natural Gas (RTM) limits which methodologies can be used for water analysis and what is the maximum permissible uncertainty for the oil flow meter in which it is inserted. However, the RTM doesn t define the uncertainty of the water analysis. There is a risk of adopting one of the permitted methods of analysis and, even so, the measurement uncertainty of the flow meter exceeds the defined by the legislation. In addition, the RTM adopts a repeatability standard when validating the calibration of ultrasonic meters, thus the influence of this on oil uncertainty is also evaluated. The methodology used is the design of experiments and response surface. The results demonstrate that the influence of the water content uncertainty analysis and of the meter factor on the uncertainty of the oil flow meter can be simulated. Finally, the conclusions show that the average currently found for uncertainty of water is adequate to maintain the oil uncertainty within the allowed by the RTM, but small variations may cause this limit to be exceeded. The influence of the meter factor uncertainty was inferior or similar to the water content and, finally, it is suggested the adoption of a standard limit of uncertainty instead of a standard of repeatability for the ultrasonic meters.

Page generated in 0.0403 seconds