1

[en] TRANSPORT COEFFICIENTS OF ICE SLURRY IN PLATE HEAT EXCHANGER / [pt] COEFICIENTES DE TRANSPORTE DA PASTA DE GELO EM UM TROCADOR DE CALOR DE PLACAS

HUGO GUILLERMO JIMENEZ PACHECO 14 January 2004 (has links)
[pt] O uso da pasta de gelo começou recentemente a ser aplicado em sistemas de refrigeração e condicionamento de ar. Como principais vantagens deste fluido, podem ser citados: a possibilidade de armazenar calor latente do gelo e a possibilidade de ser bombeado como a água fria. Assim, o pasta de gelo pode ser usado para o armazenamento térmico no lugar da água fria ou do gelo, desde que, até determinadas concentrações, possa ser bombeado através dos trocadores de calor. Para que esta tecnologia seja aceita extensamente, informações de engenharia são requeridas nas características de transporte nos equipamentos de troca de calor. Um dispositivo experimental foi desenvolvido para estudar os coeficientes de transporte do pasta de gelo em um trocador de calor de placas, utilizando água como carga térmica a resfriar. Foram investigadas várias situações para diferentes frações iniciais e vazões do pasta de gelo. As condições de entrada da carga térmica, foram mantidas constantes. São monitoradas a temperatura, a queda de pressão, a fração do gelo sólido e a vazão do pasta de gelo no trocador de calor, assim como a vazão e a de temperatura na parte da carga térmica. Os resultados mostram que o coeficiente global de troca de calor aumenta com aumento da fração inicial do gelo. A capacidade do resfriamento do trocador de calor aumenta consideravelmente, em relação da água, quando a pasta de gelo, é utilizada como fluido secundário. Finalmente, a queda de pressão aumenta com o aumento da fração inicial de gelo. / [en] The use of the ice slurry is recently applied in the refrigeration and air conditioning systems. Advantages such as the possibility to store latent heat on ice and the possibility of being pumped as cold water can be considered. Ice slurries can be used both for cold storage in place of chilled water or ice and as a secondary refrigerant since, up to certain concentrations, they can be pumped directly through distribution pipeworks and heat exchangers. For ice slurries to become more widely accepted, however, more engineering information is required on fluid flow and heat transfer characteristics. An experimental device was developed to study the transport properties of the ice slurry in plate heat exchangers. Several situations were investigated for different initial fractions and flows of ice slurry. The conditions of the thermal load (pure water), had been kept constant. The temperature field, the pressure loss, the initial fraction and the flow of ice slurry are monitored in the heat exchanger, beyond the flow and the temperature field is monitored in the part of the thermal load. The overall heat transfer coefficient, increases in function of the initial ice fraction. The capacity cooling of the heat exchanger increases with the use of ice slurry when compared to pure water. Finally can be showed that the loss of pressure increases for higher initial ice fraction.
2

[pt] DESENVOLVIMENTO E VALIDAÇÃO EXPERIMENTAL EM USINA HIDRELÉTRICA DE ALTERNATIVAS DE CÁLCULO DA EFETIVIDADE DE TROCADORES DE CALOR / [en] DEVELOPMENT AND EXPERIMENTAL VALIDATION IN A HYDROELECTRIC PLANT OF ALTERNATIVES FOR CALCULATING THE EFFECTIVENESS OF HEAT EXCHANGERS

EDGARDO RAFAEL CASTRO PACHECO 23 February 2021 (has links)
[pt] Esta dissertação teve como objetivo desenvolver uma sistemática de monitoramento para avaliar, em tempo real, a efetividade térmica de trocadores de calor (água-ar) do sistema de arrefecimento de hidrogeradores. A motivação resultou da possibilidade de se estabelecer ganhos de efetividade pela racionalização do procedimento de limpeza. Como metodologia de desenvolvimento do trabalho, duas estratégias foram perseguidas: (i) proposição de alternativas de cálculo da efetividade sem a necessidade de medir a temperatura de saída do ar (fluido quente do trocador) em um complexo escoamento perturbado por sucessivos descolamentos da camada limite em torno de cada tubo do trocador e (ii) validação da alternativa de cálculo da efetividade com base em dados reais de monitoramento de um trocador de calor de hidrogerador, em operação contínua, mesmo durante a sua limpeza on-line, portanto sem requerer a parada técnica das turbinas. Dentre os resultados, duas alternativas de cálculo da efetividade do trocador foram desenvolvidas: (i) via solução numérica do sistema de equações que governam os mecanismos de transferência de calor e (ii) via uma versão adaptada do método Épsilon-NTU, que avalia a efetividade de um trocador de calor de seis passes modelando-o como um arranjo em série de seis trocadores de um único passe. As alternativas de cálculo da efetividade apresentam concordância de cerca de 1 por cento e com baixo nível de incerteza (0,012), podendo diferir em até 30 por cento quando confrontadas com o método usual fundamentado na medição da temperatura de saída do ar. Como conclusão, as alternativas propostas mostraram-se adequadas para calcular a efetividade do trocador de calor do sistema de arrefecimento dos hidrogeradores da usina Fontes Nova (Piraí/RJ), monitorado ao longo de um período de 11 meses e sem requerer a interrupção da geração. / [en] This dissertation aimed to develop a monitoring system to evaluate, in real time, the thermal effectiveness of heat exchangers (water-air) of the cooling system of hydrogenerators. The motivation resulted from the possibility of establishing gains in effectiveness by rationalizing the cleaning procedure. As a methodology for the development of the work, two strategies were pursued: (i) proposition of alternatives for calculating effectiveness without the need to measure the outlet temperature of the air (hot fluid of the exchanger) in a complex flow disturbed by successive detachments of the boundary layer around each tube of the exchanger and (ii) validation of the alternative of calculating the exchanger effectiveness based on real data acquired during the continuous operation of the hydrogenerator unit, including the online cleaning process of the exchanger without the technical stop of the turbines. Among the results, two alternatives for calculating the effectiveness of the exchanger were developed: (i) via a numerical solution of the system of equations that govern the heat transfer mechanisms involved and (ii) via an adapted version of the Epsilon-NTU method, which evaluates the effectiveness of a six-pass heat exchanger modeling it as a series arrangement of six single pass heat exchangers. The alternatives for calculating the exchanger effectiveness have an agreement of about 1 percent and with low level of uncertainty (0.012), which may differ by up to 30 percent when compared with the usual method based on the measurement of the outlet air temperature. In conclusion, the proposed alternatives proved to be adequate to calculate the effectiveness of the heat exchanger of the cooling system of the hydrogenerators at the Fontes Nova plant (Piraí / RJ), monitored over a period of 11 months and without requiring interruption of the generation.
3

[en] EXPERIMENTAL DETERMINATION OF TRANSPORTATIONS COEFFICIENTS FOR ICE SLURRY IN PLATE HEAT EXCHANGERS / [pt] DETERMINAÇÃO EXPERIMENTAL DOS COEFICIENTES DE TRANSPORTE DA PASTA DE GELO EM TROCADORES DE CALOR DE PLACAS

LUIS CARLOS CASTILLO MARTINEZ 25 August 2005 (has links)
[pt] A pasta de gelo é uma mistura de água e um aditivo, com finas partículas de gelo, apresentando uma alta densidade de energia térmica. O principal motivo de sua utilização deve-se à combinação do aproveitamento do calor latente na mudança de fase com capacidade de ser bombeado. O presente trabalho trata do estudo experimental sobre a transfe rência de calor e queda de pressão, com mudança de fase, utilizando uma mistura de propileno glicol - água com 13,8% de concentração em peso, num trocador de calor de placas com arranjo em U para 16 placas. Realizaram-se testes de troca de calor com escoamento em paralelo e contra-corrente, para duas condições de fração mássica de gelo e números de Reynolds para a pasta de gelo entre 150 e 425, com diferentes condições de carga térmica. Dos testes foram observados aumentos de até 25% no coeficiente global de troca calor, ao se incrementar a vazão e, conseqüentemente, o número de Reynolds da pasta de gelo. Com o aumento da fração de gelo melhora-se a capacidade de resfriamento, diminuindo o número de Nusselt da pasta de gelo. O coeficiente global de troca, porém, começa a diminuir. Na literatura esta relação ainda não está bem definida. Alguns autores relatam ganhos, perdas ou indiferença no coeficiente global. Resultados do coeficiente global e do número de Nusselt, nos modos paralelo e contra-corrente, não apresentaram grande diferença. A capacidade de resfriamento em contra-corrente foi maior, apresentando valores de efetividade cerca 10% acima dos resultados observados no modo paralelo. Os fatores de atrito encontrados variaram entre 0,030 a 0,085, o que concorda com os resultados apresentados por outros pesquisadores. Como era de se esperar, o fator de atrito diminui com o aumento da vazão mássica e de maneira inversa com o aumento da fração de gelo. / [en] Ice slurry is an aqueous solution from which ice crystals are formed. These crystals possess high energy density, in the form of latent heat. Furthermore, the fact of being a slurry makes it an excellent energy carrier, for it can be easily pumped. The present work presents an experimental procedure to assess the heat transfer and the pressure loss, with phase change, using a mixture of propyleneglycol and water, 13.8% weight, in a U-plate heat exchanger with 16 plates. Tests were carried out for both parallel and counter-flow configurations of the heat exchanger, for two different mass fractions of ice and with Reynolds numbers between 150 and 425 for the slurry. Different thermal loads were considered. The experiments showed increases of up to 25% in the overall heat transfer coeficiente when the slurry flow is increased, with consequent increase in the Reynolds number. By increasing the ice fraction the cooling capacity is improved, reducing the Nusselt number. In the literature, this relationship is not clearly defined, as some authors show gains in the heat exchange coefficient, losses, and some others did not observe any influence on this parameter. Regarding the heat Exchange configuration, i.e., parallel or counter-flow, neither the heat exchange coefficient, nor the Nusselt number suffered major influence. The effectiveness is up to 10% higher for the counter-flow configuration in comparison with the parallel configuration. The figures found for the friction coefficient, between 0,030 and 0,085, are in good agreement with the literature. As expected, the friction coefficient decreases when the mass flow is increased, and increases when the ice fraction is increased.
4

[pt] AVALIAÇÃO METROLÓGICA DE UM DISPOSITIVO SERVO-HIDRÁULICO PARA MITIGAÇÃO DE INCRUSTAÇÃO EM TROCADORES DE CALOR INDUSTRIAIS / [en] METROLOGICAL EVALUATION OF A SERVO-HYDRAULIC DEVICE TO MITIGATE FOULING IN INDUSTRIAL HEAT EXCHANGERS

JEFFERSON LUIZ RANGEL RIOS 23 February 2021 (has links)
[pt] Incrustações em trocadores de calor são inevitáveis e provocam a redução da sua efetividade térmica e aumento nos custos de bombeamento. Esta dissertação objetiva validar um dispositivo alternativo de limpeza de trocadores de calor, que automatiza o processo e não requer a interrupção do processo industrial que faz uso de trocadores. A motivação da pesquisa resultou do desafio imposto ao Programa de Metrologia da PUC-Rio para conceber uma solução inovadora para realizar a limpeza on-line de trocadores de calor de hidrogeradores, viabilizada com financiamento do setor elétrico e que motivou esta dissertação. A metodologia de desenvolvimento da pesquisa de mestrado perseguiu duas estratégias de otimização: (i) aprimorar a hidrodinâmica dos circuitos hidráulicos do dispositivo de limpeza concebido, visando reduzir custos de bombeamento e (ii) simular o número de ciclos mínimos de limpeza para assegurar que todos os tubos do trocador de calor sejam visitados por artefatos de limpeza. Dentre os resultados consolidados, destacam-se: (i) melhoria dos fluxos hidrodinâmicos nos distintos tramos hidráulicos do dispositivo servo-hidráulico de limpeza; (ii) confiabilidade metrológica do sistema de medição embarcada no equipamento e (iii) desenvolvimento de modelagem probabilística capaz de prever o número de ciclos de limpeza capaz de assegurar eficácia do procedimento de limpeza do trocador, o que contribui para o seu entendimento. Os ensaios de desempenho realizados em laboratório suportam a conclusão de que a pesquisa de mestrado foi capaz de validar e disponibilizar uma versão hidrodinamicamente mais eficiente e operacionalmente mais eficaz do dispositivo de limpeza originalmente concebido. / [en] Fouling in heat exchangers is inevitable and causes a reduction in their thermal effectiveness and an increase in pumping costs. This dissertation aims to validate an alternative heat exchanger cleaning device, which automates the process and does not require the interruption of the industrial process that uses exchangers. The motivation for the research resulted from the challenge imposed on the Metrology Program at PUC-Rio to devise an innovative solution to perform the online cleaning of hydrogenerator heat exchangers, made possible with financing from the electricity sector and which motivated this dissertation. The master s research development methodology pursued two optimization strategies: (i) improving the hydrodynamics of the hydraulic circuits of the designed cleaning device, aiming to reduce pumping costs and (ii) simulating the number of minimum cleaning cycles to ensure that all the tubes of the heat exchanger are visited by cleaning artefacts. Among the consolidated results, the following stand out: (i) improvement of hydrodynamic flows in the different hydraulic sections of the servo-hydraulic cleaning device; (ii) metrological reliability of the measurement system embarked in the equipment and (iii) development of probabilistic modeling capable of predicting the number of cleaning cycles capable of ensuring the efficiency of the exchanger cleaning procedure, which contributes to its understanding. The performance tests performed in the laboratory support the conclusion that the master s research was able to validate and make available a hydrodynamically more efficient and operationally more effective version of the cleaning device originally designed.
5

[en] CFD SIMULATION OF THE FLOW IN THE HYDRAULIC CIRCUITS OF AN ONLINE HEAT EXCHANGER CLEANING DEVICE / [pt] SIMULAÇÃO CFD DO ESCOAMENTO NOS CIRCUITOS HIDRÁULICOS DE UM DISPOSITIVO DE LIMPEZA ONLINE DE TROCADORES DE CALOR

SERGIO LUIS DE LA HOZ TRUYOLL 09 July 2024 (has links)
[pt] Trocadores de calor são equipamentos essenciais do sistema de resfriamento de equipamentos de processo, visando assegurar a sua eficácia e eficiência operacional. O objetivo do trabalho é a simulação computacional do escoamento do fluido de transporte dos artefatos de limpeza de uma alternativa tecnológica de trocadores de calor que dispensa a interrupção do processo industrial. A motivação resultou do potencial da ferramenta computacional CFD em gerar resultados numéricos de interesse, complementando a base de dados experimentais em locais críticos do escoamento difíceis de serem instrumentados. A simulação foi realizada pelo Fluent/Ansys 2023 R2, utilizando-se o modelo de turbulência κ-ômega SST (Transporte da tensão de cisalhamento), baseado na abordagem média de Reynolds (RANS - Reynolds-Averaged Navier-Stokes). Os resultados da simulação (campos de velocidade, pressão e estruturas da turbulência) orientaram ajustes e melhorias localizadas no projeto construtivo da alternativa tecnológica de limpeza online proposta, permitindo eliminar zonas de recirculação e uma redução de 62,2 por cento nas perdas de carga localizadas, que tão drasticamente impactam nos custos de bombeamento do fluido de transporte dos artefatos de limpeza. A pressão simulada reproduziu o resultado da medição com 2,5 por cento de concordância. Como conclusão, a ferramenta computacional provou ser estratégica para orientar a melhoria do projeto construtivo do dispositivo inovador de limpeza online. Se por um lado os dados experimentais provêm uma referência confiável fundamentada em medições rastreáveis a padrões de referência, por outro, a simulação numérica provê relevantes informações em todo o domínio do escoamento. / [en] Heat exchangers are essential equipment in the cooling system of various process equipment, aiming to ensure its effectiveness and operational efficiency. The objective of the work is the computational simulation of the fluid flow transporting cleaning artifacts from a technological alternative for heat exchangers that does not require interruption of the industrial process. The motivation resulted from the potential of the CFD computational tool to generate numerical results of interest, complementing the experimental database in critical flow locations that are difficult to instrument. The simulation was carried out by Fluent/Ansys 2023 R2, using the κ-omega SST (Shear Stress Transport) turbulence model based on the Reynolds average approach (RANS - Reynolds-Averaged Navier-Stokes). The simulation results (velocity, pressure fields, and turbulence structures) guided adjustments and localized improvements in the constructive design of the proposed online cleaning technological alternative, allowing the elimination of recirculation zones and a 62.2 percent reduction in localized pressure losses that so drastically impact the costs of pumping the fluid to transport cleaning artifacts. The simulated pressure reproduced the measurement results with 2.5 percent agreement. In conclusion, the computational tool proved to be strategic in guiding the improvement of the constructive design of the innovative online cleaning device. If, on the one hand, experimental data provides a reliable reference based on measurements traceable to reference standards, numerical simulation provides relevant information across the entire flow domain.