• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise comparativa de inibidores de corrosão na água poro e no concreto armado para aço carbono CA-50 / Comparative analysis of corrosion inhibitors in the pore water and in reinforced concrete for carbon steel Ca-50

Ossorio Dominguez, Anile January 2016 (has links)
No presente trabalho analisa-se o comportamento do aço de reforço ante à corrosão, com o uso dos inibidores: nitrito de sódio, fosfato de sódio e etalonamina, na água de poros contaminada com cloreto, e no concreto com a finalidade de analisar seus resultados e seus mecanismos diferenciados. Para cumprir este objetivo o presente trabalho divide-se em duas etapas: uma primeira etapa baseada em simular sinteticamente a água de poro de um concreto, cuja solução é KOH 28g/l+NaOH 4g/l. Essa água de poro é simulada em ambiente marinho, cuja solução é KOH 28g/l + NaOH 4g/l+NaCl 35g/l, e a esta solução referência incorporamse os inibidores (20g/l da cada um). Realizaram-se ensaios de espectroscopia de impedância eletroquímica (EIE) (após 3 e 72 horas de imersão) e curvas de polarização (após 72 horas de imersão) com vistas a obter respostas da cinética da corrosão ante a cada solução. Obteve-se o melhor comportamento para a água de poros. No caso da água de poro contaminada por cloretos, o melhor comportamento se obteve para o inibidor nitrito de sódio. Na segunda etapa adotou-se apenas o inibidor nitrito de sódio, pois estatisticamente as eficiências dos três inibidores foram muito similares. Analisou-se o nitrito de sódio em amostras reais de concreto armado contaminado com cloreto de sódio. Para isso se elegeram dois tipos de cimentos (CP IV e CP V) e três relações água-cimento (a/c-0.4, a/c-0.5, a/c- 0.65). Para simular o ambiente marinho, realizaram-se ensaios acelerados de cloretos. Comparam-se métodos de análises simuladas sinteticamente e reais, concluindo-se em ambos meios, embora fossem um solido e outro líquido o inibidor Nitrito de Sódio aumento a sua eficiência com os ciclos de exposição. / In this paper it is analyzed the behavior of reinforcing steel against corrosion using inhibitors: sodium nitrate, sodium phosphate and ethanolamine in water contaminated with chlorides pore and concrete, in order to analyzing the results and different mechanisms. To meet the objective of this work, it was divided into two stages, a first stage based on synthetically simulate the pore water of a concrete, through the following solution KOH 28g/l+NaOH 4g/l, this same solution simulated pore water to a marine environment it would be KOH 28g/l + NaOH 4g/l+NaCl 35g/l, it is then incorporated into both reference solutions inhibitors in a proportion, (20g/l de cada um). Assays were performed electrochemical impedance spectroscopy (EIE) (last 3 hours and 72 hours of immersion) and polarization curves (last 72 hours of immersion) in order to obtain responses corrosion kinetics in each solution. the best performance was obtained in the pore water. In the case of water contaminated with chlorides pore, the best performance was obtained in the presence of sodium nitrite inhibitor. In the second step was performed only with the inhibitor sodium nitrate, as statistically efficiencies of the three inhibitors were similar. Sodium nitrate was analyzed in real samples of reinforced concrete contaminated with chlorides of sodium. So they were chosen two types of cement CP- IV and CP-V, cement water three relationships 0.4, a/c-0.5, a/c- 0.65. In this case to simulate the marine environment, accelerated tests were performed chloride. They were compared the methods of analysis, simulated synthetically and simulated in real concrete.
2

Análise comparativa de inibidores de corrosão na água poro e no concreto armado para aço carbono CA-50 / Comparative analysis of corrosion inhibitors in the pore water and in reinforced concrete for carbon steel Ca-50

Ossorio Dominguez, Anile January 2016 (has links)
No presente trabalho analisa-se o comportamento do aço de reforço ante à corrosão, com o uso dos inibidores: nitrito de sódio, fosfato de sódio e etalonamina, na água de poros contaminada com cloreto, e no concreto com a finalidade de analisar seus resultados e seus mecanismos diferenciados. Para cumprir este objetivo o presente trabalho divide-se em duas etapas: uma primeira etapa baseada em simular sinteticamente a água de poro de um concreto, cuja solução é KOH 28g/l+NaOH 4g/l. Essa água de poro é simulada em ambiente marinho, cuja solução é KOH 28g/l + NaOH 4g/l+NaCl 35g/l, e a esta solução referência incorporamse os inibidores (20g/l da cada um). Realizaram-se ensaios de espectroscopia de impedância eletroquímica (EIE) (após 3 e 72 horas de imersão) e curvas de polarização (após 72 horas de imersão) com vistas a obter respostas da cinética da corrosão ante a cada solução. Obteve-se o melhor comportamento para a água de poros. No caso da água de poro contaminada por cloretos, o melhor comportamento se obteve para o inibidor nitrito de sódio. Na segunda etapa adotou-se apenas o inibidor nitrito de sódio, pois estatisticamente as eficiências dos três inibidores foram muito similares. Analisou-se o nitrito de sódio em amostras reais de concreto armado contaminado com cloreto de sódio. Para isso se elegeram dois tipos de cimentos (CP IV e CP V) e três relações água-cimento (a/c-0.4, a/c-0.5, a/c- 0.65). Para simular o ambiente marinho, realizaram-se ensaios acelerados de cloretos. Comparam-se métodos de análises simuladas sinteticamente e reais, concluindo-se em ambos meios, embora fossem um solido e outro líquido o inibidor Nitrito de Sódio aumento a sua eficiência com os ciclos de exposição. / In this paper it is analyzed the behavior of reinforcing steel against corrosion using inhibitors: sodium nitrate, sodium phosphate and ethanolamine in water contaminated with chlorides pore and concrete, in order to analyzing the results and different mechanisms. To meet the objective of this work, it was divided into two stages, a first stage based on synthetically simulate the pore water of a concrete, through the following solution KOH 28g/l+NaOH 4g/l, this same solution simulated pore water to a marine environment it would be KOH 28g/l + NaOH 4g/l+NaCl 35g/l, it is then incorporated into both reference solutions inhibitors in a proportion, (20g/l de cada um). Assays were performed electrochemical impedance spectroscopy (EIE) (last 3 hours and 72 hours of immersion) and polarization curves (last 72 hours of immersion) in order to obtain responses corrosion kinetics in each solution. the best performance was obtained in the pore water. In the case of water contaminated with chlorides pore, the best performance was obtained in the presence of sodium nitrite inhibitor. In the second step was performed only with the inhibitor sodium nitrate, as statistically efficiencies of the three inhibitors were similar. Sodium nitrate was analyzed in real samples of reinforced concrete contaminated with chlorides of sodium. So they were chosen two types of cement CP- IV and CP-V, cement water three relationships 0.4, a/c-0.5, a/c- 0.65. In this case to simulate the marine environment, accelerated tests were performed chloride. They were compared the methods of analysis, simulated synthetically and simulated in real concrete.
3

Análise comparativa de inibidores de corrosão na água poro e no concreto armado para aço carbono CA-50 / Comparative analysis of corrosion inhibitors in the pore water and in reinforced concrete for carbon steel Ca-50

Ossorio Dominguez, Anile January 2016 (has links)
No presente trabalho analisa-se o comportamento do aço de reforço ante à corrosão, com o uso dos inibidores: nitrito de sódio, fosfato de sódio e etalonamina, na água de poros contaminada com cloreto, e no concreto com a finalidade de analisar seus resultados e seus mecanismos diferenciados. Para cumprir este objetivo o presente trabalho divide-se em duas etapas: uma primeira etapa baseada em simular sinteticamente a água de poro de um concreto, cuja solução é KOH 28g/l+NaOH 4g/l. Essa água de poro é simulada em ambiente marinho, cuja solução é KOH 28g/l + NaOH 4g/l+NaCl 35g/l, e a esta solução referência incorporamse os inibidores (20g/l da cada um). Realizaram-se ensaios de espectroscopia de impedância eletroquímica (EIE) (após 3 e 72 horas de imersão) e curvas de polarização (após 72 horas de imersão) com vistas a obter respostas da cinética da corrosão ante a cada solução. Obteve-se o melhor comportamento para a água de poros. No caso da água de poro contaminada por cloretos, o melhor comportamento se obteve para o inibidor nitrito de sódio. Na segunda etapa adotou-se apenas o inibidor nitrito de sódio, pois estatisticamente as eficiências dos três inibidores foram muito similares. Analisou-se o nitrito de sódio em amostras reais de concreto armado contaminado com cloreto de sódio. Para isso se elegeram dois tipos de cimentos (CP IV e CP V) e três relações água-cimento (a/c-0.4, a/c-0.5, a/c- 0.65). Para simular o ambiente marinho, realizaram-se ensaios acelerados de cloretos. Comparam-se métodos de análises simuladas sinteticamente e reais, concluindo-se em ambos meios, embora fossem um solido e outro líquido o inibidor Nitrito de Sódio aumento a sua eficiência com os ciclos de exposição. / In this paper it is analyzed the behavior of reinforcing steel against corrosion using inhibitors: sodium nitrate, sodium phosphate and ethanolamine in water contaminated with chlorides pore and concrete, in order to analyzing the results and different mechanisms. To meet the objective of this work, it was divided into two stages, a first stage based on synthetically simulate the pore water of a concrete, through the following solution KOH 28g/l+NaOH 4g/l, this same solution simulated pore water to a marine environment it would be KOH 28g/l + NaOH 4g/l+NaCl 35g/l, it is then incorporated into both reference solutions inhibitors in a proportion, (20g/l de cada um). Assays were performed electrochemical impedance spectroscopy (EIE) (last 3 hours and 72 hours of immersion) and polarization curves (last 72 hours of immersion) in order to obtain responses corrosion kinetics in each solution. the best performance was obtained in the pore water. In the case of water contaminated with chlorides pore, the best performance was obtained in the presence of sodium nitrite inhibitor. In the second step was performed only with the inhibitor sodium nitrate, as statistically efficiencies of the three inhibitors were similar. Sodium nitrate was analyzed in real samples of reinforced concrete contaminated with chlorides of sodium. So they were chosen two types of cement CP- IV and CP-V, cement water three relationships 0.4, a/c-0.5, a/c- 0.65. In this case to simulate the marine environment, accelerated tests were performed chloride. They were compared the methods of analysis, simulated synthetically and simulated in real concrete.
4

Avaliação da passivação e corrosão do aço CA-50 usando técnicas eletroquímicas em meio de água de poro extraída de pasta de cimento Portland com adição de escória de aciaria modificada. / Evaluation of passivation and corrosion of CA-50 steel using electrochemical techniques in pore water extracted from Portland cement paste with modified steel slag.

Vieira, Renan Esposito 02 March 2017 (has links)
A indústria cimenteira busca alternativas para economia de recursos no processo produtivo, em especial envolvendo o uso de materiais residuais no cimento, como escórias siderúrgicas. A escória de aciaria, em particular, apresenta composição desfavorável para aplicação in natura, porém há metodologias na literatura de modificação do material para aplicações cimentícias. No entanto, ainda não se encontram avaliações da corrosão de armaduras de aço em compósitos cimentícios com essa adição, seja em meio sólido ou líquido (água de poro). Esse estudo avaliou, através de curvas de polarização e da espectroscopia de impedância eletroquímica (EIE), a resistência à corrosão do aço CA-50 em soluções representativas de águas de poro extraídas por pressão de pastas de cimento com 25 % de escória de aciaria in natura ou modificada por processo pirometalúrgico. Para efeitos comparativos, foi feita também a avaliação do desempenho do aço em meios de águas de poro indicadas na literatura como representativas de cimento Portland comum e de escória de alto forno. O efeito da presença de espécies agressivas na resistência à corrosão do aço foi avaliado adicionando-se 1,0 % de NaCl em massa às soluções estudadas. Nas águas de poro sem 1,0 % de cloreto, o aço CA-50 apresentou-se passivo e não mostrou indícios de corrosão nos ensaios nem de polarização nem de EIE durante 120 h de imersão. Entretanto, os ajustes dos diagramas com circuito elétrico equivalente (CEE) apontaram que as características de proteção da camada passiva formada nas águas de poro de cimento com escória de aciaria foram superiores, resultando em maior resistência à corrosão do aço CA-50 nestes meios. Por sua vez, nos meios com 1,0 % de NaCl, após polarização e EIE até 120 h, o aço sofreu corrosão para as águas de poro de cimento comum e escória de alto forno, porém não corroeu nas águas de poro representativas de cimentos com escórias de aciaria, cujo melhor desempenho foi associado à maior alcalinidade destes meios. A caracterização microestrutural por microscopia eletrônica de varredura após os ensaios de polarização anódica e de imersão mostrou que o principal produto de corrosão formado foi a lepidocrocita (?-FeOOH), comum em ataque do aço por cloretos. / The cement industry seeks alternatives to save resources in production processes, especially involving the use of residual materials in cements, such as slags. Steel slags present unfavorable composition for application as cement additions in natura, but there are methodologies in the literature for modifying this material for commercial application. However, there are no evaluations of the corrosion of steel reinforcements in cementitious composites with steel slags, either in solid or liquid medium (pore water). The present study employed polarization curves and electrochemical impedance spectroscopy (EIS) to evaluate the corrosion resistance of CA-50 steel in pore water solutions representative of cement pastes with 25 % steel slag in natura or modified by a pyrometallurgical process. For comparison purposes, the performance of CA-50 steel in the pore waters indicated in the literature as representatives of Portland cement and blast furnace slag activated with cement were also evaluated. The effect of aggressive species on the corrosion resistance of the steel was assessed by adding 1.0 % NaCl by mass to the pore water solutions. Without 1.0 % chloride addition, CA-50 steel exhibited good performance and showed no evidences of corrosion in all of the investigated media, both in anodic polarization and in EIS tests performed up to 120 h immersion. However, the fitting of the EIS diagrams with equivalent electric circuit (EEC) revealed that the protectiveness of the passive layer formed in pore waters representative of cements with steel slags were superior, indicating better corrosion resistance of CA-50 steel in these media. Conversely, when 1.0 % chloride was added to the pore waters, CA-50 steel presented pitting corrosion, and impedance decreases with immersion in the pore waters representative of pure cement and blast furnace slag, whereas no corrosion was detected by both methodologies in pore waters representatives of cements with steel slags, which superior performance was ascribed to their higher alkalinity. Microstructural characterization by scanning electron microscopy (SEM) after anodic polarization and immersion tests showed that the main corrosion product formed was lepidocrocite (?-FeOOH), usual of chloride attack of steel.
5

Avaliação da passivação e corrosão do aço CA-50 usando técnicas eletroquímicas em meio de água de poro extraída de pasta de cimento Portland com adição de escória de aciaria modificada. / Evaluation of passivation and corrosion of CA-50 steel using electrochemical techniques in pore water extracted from Portland cement paste with modified steel slag.

Renan Esposito Vieira 02 March 2017 (has links)
A indústria cimenteira busca alternativas para economia de recursos no processo produtivo, em especial envolvendo o uso de materiais residuais no cimento, como escórias siderúrgicas. A escória de aciaria, em particular, apresenta composição desfavorável para aplicação in natura, porém há metodologias na literatura de modificação do material para aplicações cimentícias. No entanto, ainda não se encontram avaliações da corrosão de armaduras de aço em compósitos cimentícios com essa adição, seja em meio sólido ou líquido (água de poro). Esse estudo avaliou, através de curvas de polarização e da espectroscopia de impedância eletroquímica (EIE), a resistência à corrosão do aço CA-50 em soluções representativas de águas de poro extraídas por pressão de pastas de cimento com 25 % de escória de aciaria in natura ou modificada por processo pirometalúrgico. Para efeitos comparativos, foi feita também a avaliação do desempenho do aço em meios de águas de poro indicadas na literatura como representativas de cimento Portland comum e de escória de alto forno. O efeito da presença de espécies agressivas na resistência à corrosão do aço foi avaliado adicionando-se 1,0 % de NaCl em massa às soluções estudadas. Nas águas de poro sem 1,0 % de cloreto, o aço CA-50 apresentou-se passivo e não mostrou indícios de corrosão nos ensaios nem de polarização nem de EIE durante 120 h de imersão. Entretanto, os ajustes dos diagramas com circuito elétrico equivalente (CEE) apontaram que as características de proteção da camada passiva formada nas águas de poro de cimento com escória de aciaria foram superiores, resultando em maior resistência à corrosão do aço CA-50 nestes meios. Por sua vez, nos meios com 1,0 % de NaCl, após polarização e EIE até 120 h, o aço sofreu corrosão para as águas de poro de cimento comum e escória de alto forno, porém não corroeu nas águas de poro representativas de cimentos com escórias de aciaria, cujo melhor desempenho foi associado à maior alcalinidade destes meios. A caracterização microestrutural por microscopia eletrônica de varredura após os ensaios de polarização anódica e de imersão mostrou que o principal produto de corrosão formado foi a lepidocrocita (?-FeOOH), comum em ataque do aço por cloretos. / The cement industry seeks alternatives to save resources in production processes, especially involving the use of residual materials in cements, such as slags. Steel slags present unfavorable composition for application as cement additions in natura, but there are methodologies in the literature for modifying this material for commercial application. However, there are no evaluations of the corrosion of steel reinforcements in cementitious composites with steel slags, either in solid or liquid medium (pore water). The present study employed polarization curves and electrochemical impedance spectroscopy (EIS) to evaluate the corrosion resistance of CA-50 steel in pore water solutions representative of cement pastes with 25 % steel slag in natura or modified by a pyrometallurgical process. For comparison purposes, the performance of CA-50 steel in the pore waters indicated in the literature as representatives of Portland cement and blast furnace slag activated with cement were also evaluated. The effect of aggressive species on the corrosion resistance of the steel was assessed by adding 1.0 % NaCl by mass to the pore water solutions. Without 1.0 % chloride addition, CA-50 steel exhibited good performance and showed no evidences of corrosion in all of the investigated media, both in anodic polarization and in EIS tests performed up to 120 h immersion. However, the fitting of the EIS diagrams with equivalent electric circuit (EEC) revealed that the protectiveness of the passive layer formed in pore waters representative of cements with steel slags were superior, indicating better corrosion resistance of CA-50 steel in these media. Conversely, when 1.0 % chloride was added to the pore waters, CA-50 steel presented pitting corrosion, and impedance decreases with immersion in the pore waters representative of pure cement and blast furnace slag, whereas no corrosion was detected by both methodologies in pore waters representatives of cements with steel slags, which superior performance was ascribed to their higher alkalinity. Microstructural characterization by scanning electron microscopy (SEM) after anodic polarization and immersion tests showed that the main corrosion product formed was lepidocrocite (?-FeOOH), usual of chloride attack of steel.

Page generated in 0.0853 seconds