• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 550
  • 28
  • 28
  • 28
  • 23
  • 17
  • 5
  • 3
  • 2
  • Tagged with
  • 560
  • 560
  • 211
  • 111
  • 97
  • 74
  • 73
  • 73
  • 71
  • 63
  • 62
  • 62
  • 58
  • 53
  • 53
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Métodos da eletrorresistividade e polarização induzida aplicados nos estudos da captação e contaminação de águas subterrâneas : uma abordagem metodológica e prática /

Braga, Antonio Celso de Oliveira. January 2006 (has links)
Resumo: A pesquisa teve como objetivos gerais à aplicação dos métodos geoelétricos na hidrogeologia, visando: (1) estudos para captação de águas subterrâneas para abastecimento em geral; e, (2) estudos das contaminações de solos, rochas e águas subterrâneas, envolvendo as fases de investigação preventiva, confirmatória, remediação e monitoramento. Como objetivos específicos, através da aplicação dos métodos da eletrorresistividade e polarização induzida, utilizando-se das técnicas de campo da sondagem elétrica vertical - arranjo Schlumberger e caminhamento elétrico - arranjo dipolo-dipolo, e dos parâmetros de Dar Zarrouk, tem-se uma discussão e proposição metodológica e prática, em função da geologia local, sobre os produtos obtidos por essa metodologia, tais como: caracterização geológica na identificação de aqüíferos promissores e investigação de áreas contaminadas e/ou sujeitas à contaminação. Portanto, esse trabalho procurou apresentar uma discussão sobre os principais métodos e técnicas de campo dos métodos geoelétricos aplicados em estudos hidrogeológicos, com destaque na captação para abastecimento e diagnóstico de solos, rochas e águas subterrâneas frente a poluentes. A proposição metodológica apresentada, procurou aplicar uma relação entre a resolução de métodos e técnicas com custos e prazos adequados a um trabalho envolvendo a Geofísica Aplicada em estudos hidrogeológicos. O emprego da eletrorresistividade, com as técnicas da SEV e CE, por si só, revela-se decisivo para atingir os mais variados fins envolvendo esses tipos de estudos. A resistividade elétrica dos materiais geológicos, é definida, principalmente, em função de seus constituintes mineralógicos e o tipo de fluido presente, sendo, portanto, ideal para os estudos hidrogeológicos de maneira geral. Cabe ressaltar ainda... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Not available.
2

Impactos do desenvolvimento urbano nas águas subterrâneas de Natal-RN / Not available.

Melo, José Geraldo de 08 August 1995 (has links)
Neste trabalho foi estudada uma área de 90\'QUILOMETROS QUADRADOS\', onde está edificada a maior parte da cidade de Natal, com o objetivo de avaliar os riscos potenciais de contaminação das águas subterrâneas utilizadas no abastecimento desta comunidade. Foram delimitadas as áreas já afetadas e definido a origem e mecanismos das contaminações. Como fundamento básico para conhecer o processo de contaminação, foi elaborado o modelo hidrogeológico conceitual. De acordo com este modelo, as unidades geológicas representadas por arenitos do Grupo Barreiras e areias de dunas, que ocorrem no domínio da área, formam um sistema hidráulico único, complexo e indiferenciado, que foi denominado Sistema Aquífero Dunas / Barreiras. Este é, em geral, do tipo livre, de elevado potencial hidrogeológico e apresenta águas de excelente qualidade físico-química em suas condições naturais. As dunas exercem a função de uma unidade de transferência das águas de infiltração em direção aos estratos inferiores do Barreiras. Dentre os fatores potenciais de contaminação das águas subterrâneas convém destacar o sistema de disposição local de efluentes e a ocupação irregular e desordenada do terreno. O principal tipo de contaminante envolvido e o íon nitrato. Os resultados do monitoramento dos níveis d\'água de poços mostraram que os poços situados em terrenos pouco ou não ocupados respondem mais rapidamente com a ocorrência das chuvas do que aqueles situados em áreas densamente povoadas, revelando a influência da ocupação do terreno no processo de recarga do sistema aquífero. O mapa de curvas isso-concentração de nitrato indicou a presença de zonas com diferentes faixas de variação nos teores de nitrato as quais se correlacionam com a densidade populacional. Em geral, nos setores menos habitados (parte sul da área), os teores de nitrato são inferiores ao nível geral de base, ou seja, 10 mg/l, enquanto que nos setores de elevada densidade populacional, o teor de nitrato atinge mais de 100 mg/l. As exceções se verificaram no caso de potencialização do fluxo subterrâneo oriundo de áreas contaminadas, que afetam setores até mesmo não habitados. A contaminação das águas subterrâneas por nitratos ocorre, provavelmente, devido a oxidação dos amoníacos provenientes do sistema de disposição local de efluentes mediante o uso de fossas e sumidouros. O setor norte da área estudada dispõe de uma rede de esgotamento sanitário. Entretanto, em grande parte do seu domínio os teores de nitrato nas águas subterrâneas continuam elevados em até mesmo crescentes ao longo do tempo, notadamente nos bairros mais antigos e de elevada densidade populacional. Isto se atribui, ao caráter cumulativo e praticamente irreversível do processo de contaminação. / This study comprises na area of 90km2, where a major parto f the City of Natal is located. It\'s purpose is to evaluate the potential risk of groundwater contamination used by the local community. The affected areas were delineated and the origin and mechanisms of contamination were defined. A conceptual hydrogeological model was developed as a foundation in order to recognize the contamination process. According to this model, the geological units represented by sandstones of the Barreiras Group and sands dunes form a unique, complex and indifferentated hydraulic system, named the Dunes/Barreiras Aquifer System. This is a system of high hydrogeological potential and contains water of excellent natural physico-chemical quality. The dunes transfer the infiltrating waters to the lower strata of the Barreiras Group. Among the potential factors of groundwater contamination are the type of system used for the disposal of local waste water and the irregular and disorganized land occupation. The principal contaminating agent involved is the nitrate ion. The results of the water levels monitoring of various wells revealed that they ones located in unoccupied or sparsely populated areas respond quickly to rain run-off than those in densely populated areas, demonstrating the influence of land occupation in the recharche of the aquifer system. The map of nitrate iso-concentration curves indicated the presence of different variation bands in the nitrate contents, which are related to population density. Generally, in the less habited sector (southern part of the area) the nitrate content is lower at the general base level, i.e. 10mg/l, while in the sectors of high population density the nitrate content reaches over 100 mg/l. Exceptions were verified as cases of potential underground flow from contaminated areas, affecting even uninhabited sectors. The groundwater contamination by nitrates is probably due to ammonia oxidation caused by the systems of sewerage disposal into cessopools and cesspits. The northern sector of the studied area has a network of sanitary sewerage. Nevertheless, in a large part of this domain, the nitrate content in groundwater remains high and even increase with time, particularly in the older boroughs which have a higher population density. Thus is attributed to the cumulative and practically irreversible character of the contamination process.
3

Estudo experimental e numérico de problemas de percolação em modelo reduzido

Unas, Mário Sérgio Pereira January 2010 (has links)
Tese de mestrado integrado. Engenharia Civil (Geotecnia). Universidade do Porto. Faculdade de Engenharia. 2010
4

Modelo de gestão para água subterrânea

Freire, Cleuda Custodio January 2002 (has links)
A Política Nacional de Recursos Hídricos e as legislações estaduais têm como principal objetivo racionalizar o uso da água devido à sua escassez. Para isto, instituem cinco instrumentos para a gestão dos recursos hídricos no Brasil e dentre eles estão a outorga e a cobrança pelo uso da água. A água subterrânea vem sendo cada vez mais utilizada em todo o mundo devido, principalmente, ao seu baixo custo e boa qualidade. Ferramentas que auxiliem aos órgãos gestores na aplicação destes instrumentos são, portanto, de extrema necessidade. Este trabalho tem como objetivo geral o desenvolvimento de metodologias para gestão de águas subterrâneas, a partir de sugestões de critérios de outorga e cobrança, no intuito de preencher uma lacuna metodológica existente nas práticas brasileiras de gestão de recursos hídricos subterrâneos. O modelo de simulação/otimização proposto visa auxiliar aos órgãos gestores dos recursos hídricos em suas “tomadas de decisão”, quando estas se referirem à gestão da água subterrânea. O modelo foi aplicado no Aqüífero dos Ingleses, localizado no litoral de Santa Catarina/Brasil, e os resultados obtidos demonstraram a grande utilidade desta ferramenta como base para a emissão de outorgas e referência para a cobrança de águas subterrâneas.
5

Produtividade e qualidade da água nos poços no meio fissural do alto do Vale do Rio Moxotó - PE

MORAIS, Franklin de January 2000 (has links)
Submitted by João Victor Mendes Souza (j.victor_play@hotmail.com) on 2016-08-30T14:06:55Z No. of bitstreams: 1 relatorio03a03.pdf: 4050914 bytes, checksum: cc7fefc983734886c430c9463a2eb406 (MD5) / Approved for entry into archive by Flasleandro Oliveira (flasleandro.oliveira@cprm.gov.br) on 2016-08-30T17:17:42Z (GMT) No. of bitstreams: 1 relatorio03a03.pdf: 4050914 bytes, checksum: cc7fefc983734886c430c9463a2eb406 (MD5) / Approved for entry into archive by Flasleandro Oliveira (flasleandro.oliveira@cprm.gov.br) on 2016-08-30T17:19:33Z (GMT) No. of bitstreams: 1 relatorio03a03.pdf: 4050914 bytes, checksum: cc7fefc983734886c430c9463a2eb406 (MD5) / Made available in DSpace on 2016-08-30T17:21:40Z (GMT). No. of bitstreams: 1 relatorio03a03.pdf: 4050914 bytes, checksum: cc7fefc983734886c430c9463a2eb406 (MD5) Previous issue date: 2000-08-24
6

Caracterização do Sistema Aquífero Parecis na região Centro-Norte do estado de Mato Grosso : subsídios para a gestão dos recursos hídricos subterrâneos

Silva, Talita Menezes Gomes da 19 April 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Programa de Pós-Graduação em Geociências Aplicadas, 2013. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2013-07-22T15:36:14Z No. of bitstreams: 1 2013_TalitaMenezesGomesSilva.pdf: 5878892 bytes, checksum: bf21cab9902e5a4bfc05bb039fb4a252 (MD5) / Approved for entry into archive by Leandro Silva Borges(leandroborges@bce.unb.br) on 2013-07-24T19:11:10Z (GMT) No. of bitstreams: 1 2013_TalitaMenezesGomesSilva.pdf: 5878892 bytes, checksum: bf21cab9902e5a4bfc05bb039fb4a252 (MD5) / Made available in DSpace on 2013-07-24T19:11:10Z (GMT). No. of bitstreams: 1 2013_TalitaMenezesGomesSilva.pdf: 5878892 bytes, checksum: bf21cab9902e5a4bfc05bb039fb4a252 (MD5) / O Sistema Aquífero Parecis (SAP) representa um reservatório subterrâneo, isotrópico, de extensão regional, constituído por sucessões de arenitos finos a médios, arenitos conglomeráticos, níveis de arenitos silicificados, níveis pelíticos e níveis 2lateritizados. A área efetiva do SAP tem cerca de 200.000 Km e corresponde a área de extensão das rochas do Grupo Parecis. A zona não saturada do SAP é representada por uma espessa camada de latossolos e coberturas inconsolidadas neógena-quaternária. Os latossolos e os sedimentos inconsolidados, associados ao relevo de platôs, controlam o mecanismo de recarga do Sistema Aquífero Parecis. A partir das feições hidrogeológicas determinadas pela análise e interpretação de ensaios de bombeamento de poços profundos, foi possível classificar qualitativamente o SAP em dois conjuntos denominados de Subsistema Livre e o Subsistema Confinado. Os parâmetros hidrodinâmicos determinados para cada subsistema aquífero são: -2condutividade hidráulica (K) de 3,5 x 10 m/s, coeficiente de armazenamento (S) de 3,33 x -1 210 e transmissividade (T) de 3,3 m/s para o aquífero livre; condutividade hidráulica de 1,3 -2 -2 -x 10 m/s, coeficiente de armazenamento (S) de 1,17 x 10 e transmissividade de 5,6 x10 1m²/s para o aquífero confinado. As avaliações preliminares para as reservas hídricas do SAP, considerando o limite 12 3definido da área de abrangência do sistema, totalizam 2,88 x 10 m para a reserva 10 3 11permanente; 2,4 x 10 m/ano para a reserva renovável, e reserva explotável de 2,54 x 10 3m. Com o propósito de auxiliar as autoridades competentes, no que se refere à gestão dos aquíferos, sugere-se a adoção de ações de âmbito regional e local para gerenciamento dos reservatórios. As ações regionais devem incluir: revisão dos critérios de outorga; determinação das reservas permanentes e renováveis; ampliação do conhecimento dos aquíferos e determinação da vulnerabilidade pelo método GOD. Dentre as ações propostas para gerenciamento local destacam-se: hidrometragem; construção adequada dos poços; determinação da vulnerabilidade pelo método DRASTIC; determinação das reservas explotáveis; determinação e proteção de área de recarga e implantação de projetos de recarga artificial dos aquíferos. ______________________________________________________________________________ ABSTRACT / The Parecis Aquifer System (SAP) is a groundwater reservoir with regional extension, consisting from fine to medium sandstones sequences, conglomeratic sandstones, silicified sandstone, pelitic and laterite levels and beds. The effective area of SAP has about 2200,000 km, that is equal to the extension area of the Parecis Group rocks. The SAP unsaturated zone is represented by a thick layer of Oxisols and Neogene-Quaternary unconsolidated cover. The Oxisols and unconsolidated sediments associated with plateaus relief, control the recharge mechanism of the Parecis Aquifer System. From the hydrogeological features, determined by the analysis and interpretation of pumping tests of deep wells, it was possible to qualitatively classify the aquifer system into two subsystems: the Unconfined Subsystem and the Confined Subsystem. The hydrodynamic parameters -2determined for each subsystem aquifer are hydraulic conductivity (K) of 3,54 x 10 m/s, -1 2storage coefficient (S) de 3,33 x 10 and transmissivity (T) of 3,33 m/s for the unconfined -2 -2aquifer; hydraulic conductivity of 1,37 x 10 m/s, storage coefficient (S) de 1,17 x 10 and -1transmissivity of 5,67 x10 m²/s for the confined aquifer. Preliminary assessments for water reserves of the Parecis Aquifer System 12 3considering the defined limit area of the system reach 2,88 x 10 m of permanent reserve, 10 3 11 32,4 x 10 m/year of renewable reserve, and exploitable reserves of 2,544 x 10 m/year. With the purpose of assisting the competent authorities with regard to the management of these aquifers, it is suggested the adoption of actions at the regional and local scale to the management of the reservoirs. The regional actions include the review of criteria to determine the yield for users; determination of the permanent reserves and resources; enhance the knowledge of the aquifers and determine the vulnerability by the GOD method. The proposed actions to the local management must consider water consume measurement; construction of the wells by adequate technical criteria; determination of the vulnerability using the DRASTIC method, determination of the exploitable reserves; determination and protection of the recharge area, and development of artificial recharge techniques.
7

Modelo de gestão para água subterrânea

Freire, Cleuda Custodio January 2002 (has links)
A Política Nacional de Recursos Hídricos e as legislações estaduais têm como principal objetivo racionalizar o uso da água devido à sua escassez. Para isto, instituem cinco instrumentos para a gestão dos recursos hídricos no Brasil e dentre eles estão a outorga e a cobrança pelo uso da água. A água subterrânea vem sendo cada vez mais utilizada em todo o mundo devido, principalmente, ao seu baixo custo e boa qualidade. Ferramentas que auxiliem aos órgãos gestores na aplicação destes instrumentos são, portanto, de extrema necessidade. Este trabalho tem como objetivo geral o desenvolvimento de metodologias para gestão de águas subterrâneas, a partir de sugestões de critérios de outorga e cobrança, no intuito de preencher uma lacuna metodológica existente nas práticas brasileiras de gestão de recursos hídricos subterrâneos. O modelo de simulação/otimização proposto visa auxiliar aos órgãos gestores dos recursos hídricos em suas “tomadas de decisão”, quando estas se referirem à gestão da água subterrânea. O modelo foi aplicado no Aqüífero dos Ingleses, localizado no litoral de Santa Catarina/Brasil, e os resultados obtidos demonstraram a grande utilidade desta ferramenta como base para a emissão de outorgas e referência para a cobrança de águas subterrâneas.
8

Avaliação de processos de caracterização e remediação de passivos ambientais de contaminação por hidrocarbonetos /

Silva, Palloma Ribeiro da. January 2009 (has links)
Orientador: José Augusto de Lollo / Banca: Maurício Augusto Leite / Banca: Lissandra Xavier Ito / Resumo: A remediação de solos e águas subterrâneas impactadas por derramamentos de petróleo é uma atividade que geralmente envolve altos custos e longos períodos de tempo. Técnicas convencionais como a escavação dos solos contaminados, seguida de tratamento ou disposição em aterros, têm sido utilizadas para efetuar a remediação de locais contaminados, apesar de apresentarem, muitas vezes, elevados custos, bem como possibilitarem impactos adicionais ao ambiente. Além destas, outras técnicas têm sido aprimoradas, testadas e avaliadas em relação a sua eficiência/eficácia e custo, incluindo a contenção, biorremediação, desorção térmica, oxidação química, extração de vapores, bombeamento e tratamento de águas subterrâneas. Uma técnica de bombeamento e tratamento do solo e água subterrânea é o MPE - Extração Multifásica. O presente estudo caracterizou duas ocorrências de passivos ambientais e o processo de remediação da fase livre das águas subterrâneas contaminadas por hidrocarbonetos derivados do petróleo utilizando o sistema de extração multifásica. No estudo de caso foram analisados dois postos. No posto 1 foi calculada uma área de 2.000m² de fase livre, resultando em um volume de 300m3. O posto 2 apresentou um volume menor de fase livre, foi calculada uma área de 40m², com volume de 1m3. Após 12 meses de operação do sistema MPE houve uma redução de 100% da espessura da fase livre no posto 1 . O posto 2, que possui solo mais argiloso, em 16 meses de operação houve uma redução de 99% da espessura da fase livre. Como esperado, a remoção da fase livre pelo sistema MPE foi mais eficiente no solo argiloarenoso, encontrado no posto1, mas contrariando a muitos autores também apresentou eficiência no solo argiloso do posto 2 / Abstract: Remediation of soil and groundwater impacted by oil spill is a process which normally involves elevated costs and long periods of time. Conventional techniques such as excavation of contaminated soils followed by special treatments or deposit on landfills has been used to remediate areas with contaminated soil. However this treatment can also create new impacts to the environment where contamination had been deposited. In addition, new techniques such as contention, bioremediation, thermal desorption, chemical oxidation, air stripping and pumping treatment has been developed, tested and evaluated by their efficiency, effectiveness and costs. The Multi Phase Extraction (MPE) is a pumping treatment technique used in the present study. The study characterised two episodes of environmental liabilities, as well as the process of remediation, applying the MPE technique to remediate the free phase of petroleum hydrocarbons present in the groundwater. The first area studied was a petrol station which had an area of 2000 square meters of petroleum hydrocarbon contaminated soil, resulting in a volume of 300 cubic meters of free phase in the groundwater. The second petrol station had a volume of free phase of petroleum hydrocarbon smaller than the first one. It had an area of 40 square meters of contaminated soil, resulting a volume of 1 cubic meter of free phase in the ground water. Twelve months after the MPE system was implanted, the thickness of the free phase had decreased 100%, at the first petrol station. The second area, where the MPE was implanted, took sixteen months to reduce 99% of the petroleum hydrocarbon thickness, owing to the second petrol station being situated in an area of clay soil. The remediation of the petroleum hydrocarbon in the groundwater by the MPE system was more efficient in the first area as expected, owing to the knowledge that the first petrol station is located in... (Complete abstract click electronic access below) / Mestre
9

Estudo hidrofaciológico do aqüífero Rio Claro no município de Rio Claro - SP /

Oliva, Andresa. January 2006 (has links)
Orientador: Chang Hung Kiang / Banca: Osmar Sinelli / Banca: Walter Malagutti Filho / Banca: Vagner Roberto Elis / Banca: Walter Eugênio de Medeiros / Resumo: São aqui apresentados os resultados de pesquisa desenvolvida no Aqüífero Rio Claro, constituído pelos sedimentos cenozóicos da Formação Rio Claro, que recobre extensa área do município homônimo no estado de São Paulo. O objetivo central desta pesquisa é a caracterização hidrofaciológica do Aqüífero Rio Claro, no Município de Rio Claro, por meio da utilização de métodos geofísicos. Para tanto, foi aplicado o método geoelétrico da eletrorresistividade, utilizando as técnicas de sondagem elétrica vertical e imageamento elétrico 2D e 3D, em escala de município e de detalhe (Campus Bela Vista da Unesp de Rio Claro). Por meio de levantamento geofísico foi possível identificar e delimitar as litofácies que constituem o aqüífero, de maneira a estabelecer uma subdivisão das unidades geoelétricas. Com base nesta subdivisão, foram elaborados mapas de resistividade em escalas de município e de detalhe, com intuito de verificar a distribuição espacial das eletrofácies presentes no Aqüífero Rio Claro, na zona saturada. Foram elaborados ainda mapas de isoespessuras do Aqüífero Rio Claro e de cota do topo da Formação Corumbataí. Os dados obtidos com as SEVs passaram por tratamento geoestatístico, que possibilitou o aprofundamento de análises interpretativas quanto aos modelos de distribuição e correlações. A partir de dados extraídos de poços de monitoramento, foram definidas as propriedades hidráulicas do aqüífero, por meio de testes de Slug, análise granulométrica e testes de produção; condutividade hidráulica na zona não-saturada foi obtida por meio do método Guelph. Os dados geofísicos revelam que a eletrofácies arenosa da Formação Rio Claro abrange grande parte da área; a silto-arenosa e a silto-argilosa estão distribuídas aleatoriamente, e que existe ampla variação na espessura da Formação Rio Claro, caracterizando um substrato bastante irregular. / Abstract: Results are presented for research carried out in the Rio Claro Aquifer constituted by Cenozoic sediments of the Rio Claro Formation that recovers extensive area of the homonym city in the state of São Paulo. The main objective of this research is hydrofacies characterization of the Rio Claro Aquifer, using geophysical methods. Electrical resistivity method was applied using vertical electric sounding (VES) and 2D and 3D imaging techniques, in municipal scale and detail scale (Campus of Unesp). Using geophysical survey was possible to identify and to delimit lithofacies that constitute the aquifer, in order to establish a subdivision of the geoelectrics units. This subdivision was used to construct maps of resistivity in detail and municipal scales, aiming to verify the spatial distribution of the electrofacies in saturated zone of the Rio Claro Aquifer. Maps of iso-thicknesses of the Rio Claro Aquifer and of the elevation of the top of the Corumbataí Formation were made. The VES data underwent geoestatistical analysis that made possible a carefull study of interpretative analysis and statistical correlations. Using data extracted from the monitoring wells, the hydraulic properties of the aquifer were obtained, through slug tests, granulometric analysis and production tests; hydraulic conductivity in non-saturated zone was determined using Guelph permeameter. The geophysical data show that arenaceous electrofacies of the Rio Claro Formation covers large part of the area; the siltarenaceous and silt-argillaceous electrofacies have random distribution, and there is a broad variation in the thickness of the Rio Claro Formation, characterizing an irregular substratum. / Doutor
10

Fatoração QR como ferramenta para a determinação de poços principais em redes de monitoramento de aqüíferos freáticos

Maciel, Susanne Tainá Ramalho 12 September 2008 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Geociências, 2008. / Submitted by Luiza Moreira Camargo (luizaamc@gmail.com) on 2011-07-05T14:31:49Z No. of bitstreams: 1 2008_SusanneTainaRamalhoMaciel.pdf: 2316601 bytes, checksum: 7ffa34644692030c5d3a921f6541162a (MD5) / Approved for entry into archive by Elna Araújo(elna@bce.unb.br) on 2011-07-09T00:13:37Z (GMT) No. of bitstreams: 1 2008_SusanneTainaRamalhoMaciel.pdf: 2316601 bytes, checksum: 7ffa34644692030c5d3a921f6541162a (MD5) / Made available in DSpace on 2011-07-09T00:13:37Z (GMT). No. of bitstreams: 1 2008_SusanneTainaRamalhoMaciel.pdf: 2316601 bytes, checksum: 7ffa34644692030c5d3a921f6541162a (MD5) / Redes de monitoramento da variabilidade piezométrica são cada vez mais utilizadas para a avaliação e gestão de aqüíferos. Com o objetivo de determinar poços principais, foi utilizada uma versão da decomposição QR com pivoteamento em quatro redes. Uma das redes está localizada na bacia do alto rio Jardim, na porção leste do Distrito Federal, e as outras três no sul do estado do Tocantins, como parte do monitoramento hidrogeológico para a construção da barragem da AHE Peixe Angical. Uma vez definidos os poços principais, a superfície piezométrica nos demais poços é calculada através de uma abordagem por quadrados mínimos, que define regiões de controle da variabilidade piezométrica. Estas regiões coincidem com a cobertura pedológica da região. Para a rede da bacia do alto rio Jardim, foi possível reduzir em 82% o número de poços a serem monitorados, e nas redes do sul do Tocantins, houve uma redução de aproximadamente 50%. A simulação do movimento dos níveis da água feitos a partir dos registros dos poços principais selecionados retornou 99% de correlação com a variação original. _________________________________________________________________________________ ABSTRACT / Monitoring networks of piezometric motion are increasingly used for evaluation and management of aquifers. A pivoted version of the QR factorization was used in four networks, with the purpose of determining principal wells. One network is located at river Jardim watershed, at the east portion of Distrito Federal, Brazil, and the other three are located in south portion of Tocantins state, as part of the hydrogeologic monitoring for the construction of AHE Peixe Angical dam. Once defined the principal wells, the piezometric surface is calculated through a least-squares approach, which determines control regions of piezometric variability. Those regions match with soil coverage. At the river Jardim watershed, it was possible to reduce in 82% the number of wells to be monitored. The networks located in south Tocantins were reduced in 50% approximately. The water level movement simulation generated from principal wells records returned 99% correlation with original fluctuation.

Page generated in 0.0987 seconds