• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 550
  • 28
  • 28
  • 28
  • 23
  • 17
  • 5
  • 3
  • 2
  • Tagged with
  • 560
  • 560
  • 211
  • 111
  • 97
  • 74
  • 73
  • 73
  • 71
  • 63
  • 62
  • 62
  • 58
  • 53
  • 53
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Hidroquímica dos aqüíferos freáticos da Bacia do Rio Jardim - DF

Araújo, Sandrine Ferraz 02 June 2006 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Geociências, 2006. / Submitted by wiliam de oliveira aguiar (wiliam@bce.unb.br) on 2011-07-06T19:41:14Z No. of bitstreams: 1 2006_Sandrine Ferraz Araujo.pdf: 33970717 bytes, checksum: 3edf85abbaac14fd7ec085d6f1afb6f4 (MD5) / Approved for entry into archive by Elna Araújo(elna@bce.unb.br) on 2011-07-08T01:17:03Z (GMT) No. of bitstreams: 1 2006_Sandrine Ferraz Araujo.pdf: 33970717 bytes, checksum: 3edf85abbaac14fd7ec085d6f1afb6f4 (MD5) / Made available in DSpace on 2011-07-08T01:17:03Z (GMT). No. of bitstreams: 1 2006_Sandrine Ferraz Araujo.pdf: 33970717 bytes, checksum: 3edf85abbaac14fd7ec085d6f1afb6f4 (MD5) / A hidroquímica é uma importante ferramenta como base para avaliação da qualidade de águas. Análises químicas associadas a características da área podem fornecer informações suficientes para definir a qualidade da água subterrânea. A bacia hidrográfica do rio Jardim, DF, tem grande diversidade de solo, litologia, níveis freáticos, uso e ocupação. Foram escolhidos 30 pontos de amostragem que abrangessem essas características e as épocas de coleta foram escolhidas de acordo com distribuição pluviométrica: março, período de máxima precipitação; julho, após as chuvas e outubro, início das chuvas. Foram medidos também os níveis freáticos e feitas análises de elementos traços, maiores e parâmetros físico-químicos. Devido à intensa atividade agrícola na área estudada, a pesquisa teve como objetivo: identificar locais vulneráveis à contaminação do aqüífero (poços com lençol freático raso e próximos ou em áreas submetidas à agricultura intensiva), identificar pontos onde não há atividade antrópica (de forma a estabelecer os valores de referência para as análises geoquímicas); obter informações sobre principais agrotóxicos e corretivos utilizados e analisar a qualidade da água subterrânea freática da bacia hidrográfica do Alto Jardim Por meio das análises geoquímicas verificou-se que alguns pontos amostrados serviram de background da área por não apresentarem concentrações anômalas em nenhum parâmetro e estarem em áreas sem prática agrícola. Após os tratamentos estatísticos identificou-se a origem dos parâmetros analisados e se são antrópicos ou não. Foi possível então concluir que não há relação entre pedologia, litologia e contaminação. O nível freático também não foi um fator discriminante, mas observou-se que aqüíferos com níveis freáticos muito rasos são mais suscetíveis à contaminação. A maioria dos poços, onde ocorreram anomalias, está localizada em áreas agrícolas nas quais há uso intensivo de fertilizantes a base de nitrato, fosfato e sulfato, que percolam o solo até atingirem as águas subterrâneas. Há também poços, onde foram observados valores anômalos, que estão em áreas sem atividade agrícola e devem ter recebido alguma contribuição de águas freáticas contaminadas a montante. _________________________________________________________________________________ ABSTRACT / Hydrochemistry is an important tool to evaluate water quality. Chemical analysis associated with characteristics of the study area can supply enough information to define the quality of groundwater. The hydrographic basin of rio Jardim, DF, has great diversity in soil, groundwater level, lithology, and land use and occupation. Thirty sampling points have been chosen in order to include these characteristics. Sampling period was defined in accordance to the rains seasons: March, period of maximum precipitation; July, after rain season; and October, beginning of rain season. The depth to the water level, trace and major elements, and physical chemistry analysis were conducted. Due to intense agricultural activity in the studied area, the investigation aimed the identification of places vulnerable to groundwater contamination (wells with near surface water level close, or inside areas of intense agricultural activity); identification of places of no anthropic activity (in order to establish reference values to the chemical analysis); gather information on the main agricultural defensives and soil correctors and evaluate the groundwater quality of the rio Jardim basin. Through the chemical analysis, it was verified the some of the sampled places could be used to define parameters background, to the study area. Data collected in these places, located in areas without agricultural activity, showed no anomalous concentration in all investigated parameters. After statistical treatment of the data it was inferred its anthropic nature or not.It was possible to conclude that there is no correlation involving soil, lithology and contamination. The water level it is not a discriminant feature, however, it was observed that aquifers with very shallow water levels are more prone to contamination. The majority of the wells showing parameters with anomalous values is located in agricultural areas showing intense use of nitrate, phosphate, and sulfate based fertilizers. These percolate through the upper soil layers and reach the groundwater level. Some of the wells showing parameters with anomalous values are located in areas with no agricultural activity. The data suggests that these wells may have received some contribution from contaminated waters located up flow.
112

Estudo da contaminação do lençol freático por hidrocarbonetos utilizando modelagem computacional / Study of hydrocarbons aquifer contamination using computational modeling

Távora, Bruno Esteves 22 March 2010 (has links)
Dissertação (mestrado)-Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2010. / Submitted by Luiza Moreira Camargo (luizaamc@gmail.com) on 2011-07-05T16:06:21Z No. of bitstreams: 1 2010_BrunoEstevesTavora.pdf: 8176275 bytes, checksum: 8365f16faa0119127a2941e1acdc54f1 (MD5) / Approved for entry into archive by Elna Araújo(elna@bce.unb.br) on 2011-07-08T21:35:49Z (GMT) No. of bitstreams: 1 2010_BrunoEstevesTavora.pdf: 8176275 bytes, checksum: 8365f16faa0119127a2941e1acdc54f1 (MD5) / Made available in DSpace on 2011-07-08T21:35:49Z (GMT). No. of bitstreams: 1 2010_BrunoEstevesTavora.pdf: 8176275 bytes, checksum: 8365f16faa0119127a2941e1acdc54f1 (MD5) / O presente trabalho consistiu na calibração e na aplicação de um modelo computacional capaz de simular o fluxo subterrâneo de um aqüífero livre e, posteriormente, o comportamento de uma contaminação provocada pelo derramamento de gasolina nesse aqüífero. O objetivo foi o de reproduzir o caso ocorrido no Distrito Federal, no ano de 2002, determinando a cronologia do acidente e a exposição dos usuários das águas subterrâneas do entorno da fonte de contaminação. Para tanto, foram utilizados dados de nível potenciométrico e extensão da pluma de contaminação, obtidos a partir dos relatórios de remediação ambiental junto ao órgão de meio ambiente do Distrito Federal. Utilizou-se, na simulação, o benzeno como contaminante de interesse, uma vez que esse composto apresenta características carcinogênicas, portanto de maior risco à saúde humana. A partir do modelo de fluxo, devidamente calibrado, foi possível determinar a velocidade de migração da gasolina, considerando um sistema bifásico, formado pela água e pela fase líquida leve não aquosa. Esse procedimento possibilitou a definição do momento inicial do derramamento para, a partir desse ponto, proceder à simulação de um cenário com condições prováveis em que ocorreu o transporte do benzeno no aqüífero. Os dados sugerem que o início do vazamento ocorreu aproximadamente 16 meses antes da detecção do fato e de que foram superados os valores máximos para potabilidade de água para o benzeno, no ponto de captação, aproximadamente 13 meses após o início do vazamento. Entre os parâmetros que regem o transporte de contaminantes, o coeficiente de decaimento apresentou maior sensibilidade no modelo, tanto com relação à velocidade de migração da pluma como para a concentração máxima atingida, seguido pelo coeficiente de distribuição. _________________________________________________________________________________ ABSTRACT / The present work was carried out to simulate the accident occurred in 2002 at Distrito Federal- Brazil, delineating the disaster chronology and exposition of the dwellers to contaminated ground water, by using computational modeling to simulate the groundwater flow and the transport behavior of benzene contaminant from a gasoline spill into the groundwater. As input, water table level and gasoline plume extension data were used. The data used in the present work were obtained from remediation reports of the local environmental agency. The benzene was assumed as the target contaminant for the transport simulation, considering that it has proved carcinogenic effect, so of higher risk to human health. With the calibrated flow model the gasoline flow velocity and the starting spill date were estimated, considering a two-phase flow system composed by the water and the light non-aqueous phase liquid. With this information, a scenario of probable benzene transport was simulated. The model results suggest that the spill has begun 16 months before the accident’s detection and the benzene level limit for drinking water, at the point of groundwater withdraw, was reached 13 months after the spill beginning. Among the transport equation parameters, the benzene decay was the most important to migration velocity and maximum concentration level, followed by the distribution coefficient.
113

Concentrações de randônio nas águas subterrâneas, rochas e solos de Porto Alegre, RS

Fianco, Ana Clara Butelli January 2011 (has links)
Muitos sistemas de abastecimento público no Brasil utilizam água subterrânea como parte de sua rede. Este é o caso do Município de Porto Alegre, capital do Rio Grande do Sul, cuja população é de cerca de 1,4 milhões de habitantes. No entanto, há pouco conhecimento sobre os fatores que afetam a presença radônio nas águas subterrâneas, apesar da importância econômica. Análises de 222Rn em amostras de água subterrânea e solo foram realizadas em diversos locais de Porto Alegre, com o objetivo de investigar os principais fatores que afetam sua presença em solução. As concentrações de radônio na água e no solo foram medidas através do equipamento AlphaGUARD (Genitron GmbH). Nas rochas, os teores foram medidos por Espectrometria Gama com detector de NA(Tl), através da concentração de 226Ra (Ue, urânio equivalente), a fim de obter informações sobre a geração de 222Rn pelas rochas do aqüífero. A geologia da área compreende diferentes granitóides de afinidade cálcico-alcalina a alcalina parcialmente cobertos por sedimentos quaternários aluviais, lagunares e fluviais. Estes dois compartimentos constituem os chamados Sistema Aqüífero Fraturado Pré-Cambriano e o Sistema Aqüífero Poroso Cenozóico. Cerca da metade das amostras analisadas de água apresentaram concentração de 222Rn dissolvido superior ao limite máximo estabelecido pela Organização Mundial de Saúde de 100 Bq/L, podendo atingir até 500 Bq/L. O teor de radônio dissolvido nas águas subterrâneas do Sistema Aqüífero Fraturado Pré-Cambriano apresenta correlação direta e significativa com o urânio equivalente presente na matriz das rochas, como resultado típico da interação água-rocha. A aeração foi confirmada como um fator importante para a liberação radônio, como esperado, devido à sua natureza gasosa. Este processo foi provavelmente responsável pela falta de relação entre radônio produzido por rochas e sua presença em solos. A região correspondente ao Sistema Aquífero Fraturado Pré-Cambriano constitui importante reservatório de água subterrânea e pode liberar grandes quantidades de radônio para a fase líquida durante a interação rocha-água. Com isto, as autoridades locais responsáveis pela gestão dos recursos hídricos e pelo gerenciamento ambiental devem estar atentas para a questão, pois o radônio é reconhecido como causador de casos fatais de câncer, quando ingerido continuamente na água potável ou contido em ambientes fechados. / Many water-supply systems in Brazil utilize groundwaters at least as part of their networks. This is the case of Porto Alegre, capital of Rio Grande do Sul State, whose population is about 1.4 million inhabitants. However, there is little present knowledge in Brazil of the factors affecting Rn presence in the water supplied for end-users, despite the economic importance of groundwaters. 222Rn analyzes groundwater and soil samples were performed at several sites in Porto Alegre, Brazil, with the aim of investigating the major factors affecting its presence in solution. Analysis for 226Ra (eU, equivalent Uranium) activity concentration was also performed in selected rock samples in order to obtain information on the 222Rn generation by the aquifer rock matrices. Several samples exhibited dissolved 222Rn activity concentration exceeding the World Health Organization maximum limit of 100 Bq/L. The dissolved radon content in groundwaters providing from the Fractured Pre-Cambrian Aquifer System exhibited direct significant correlation with the equivalent uranium in the rock matrices, as a typical result of water-rock interactions. Aeration was confirmed as an important factor for Rn release, as expected due to its gaseous nature. This process was responsible for the lack of relationship between radon produced by rocks and its presence in soils. Thus, despite the calcic-alkaline to alkaline Pre-Cambrian granitoid rocks of the area studied are important reservoirs for underground resources, they can release high amounts of the gas radon to the liquid phase, claiming the attention of the local authorities responsible by the management of the hydrological resources as much attention has been paid to Rn in waters since it is considered a constituent that may be responsible for fatal cancers when continuously ingested in drinking water or confined in closed environments.
114

Estudo da anomalia de cromo nas águas subterrâneas da região noroeste do estado de São Paulo / Not available.

Marta Lúcia Nunes Almodovar 26 October 1995 (has links)
A ocorrência de cromo nas águas subterrâneas da região noroeste do Estado de São Paulo tem se configurado como uma grande preocupação, uma vez que as cidades possuem no recurso hídrico subterrâneo a única fonte de água para suprir suas necessidades. O sistema aquífero Bauru atende a uma ampla demanda de água, desde núcleos urbanos de pequeno porte e indústrias, até propriedades rurais que necessitam de água para irrigação. Esta pesquisa objetiva caracterizar a extensão espacial da anomalia de cromo nas águas subterrâneas da região noroeste paulista; desenvolver um estudo geoquímico das águas, sedimentos e rochas da cidade de Urânia; definir a relação saúde pública e a presença de cromo nas águas subterrâneas utilizadas para abastecimento público. Inicialmente, a anomalia de cromo foi detectada em poços tubulares e cacimbas do município de urânia, região de Jales, sendo que em alguns locais, a presença deste elemento supera o valor máximo permissível em águas para consumo humano, que é de 0,05mg/l (Decreto Estadual 12.486, de 20-10-78 e portaria 36, do Ministério da Saúde, de 19-01-90). Com as análises químicas de águas subtenâneas de 54 localidades no período de 1977 a 1993, executadas pela companhia Estadual de saneamento Básico (SABESP), sabe-se hoje em dia, que esta anomalia extende-se a outros municípios da região noroeste do Estado. Estudos geoquímicos dos sedimentos da Formação Adamantina e rochas basálticas da Formação Serra Geral da cidade de Urânia, mostram que enquanto as concentrações de cromo nos primeiros estão acima da média encontrada em sedimentos similares da crosta terrestre, nas rochas basálticas, as concentrações estão abaixo da média dos basaltos da crosta. Um levantamento sobre a saúde da população de Urânia mostrou que não foi realizado nenhum estudo na região que comprovasse doenças causadas pela ingestão de água contendo cromo acima do limite de potabilidade. Através da integração dos dados e do estudo sistemático dos teores de cromo nas águas, sedimentos e rochas, chegou-se as seguintes conclusões: - a anomalia de cromo extende-se além da cidade de urânia, a outros municípios e distritos do noroeste paulista; - a distribuição das concentrações de cromo é irregular, tanto temporal quanto espacialmente; - a origem do cromo é discutível, apesar de fortes evidências de ser natural (a anomalia estar distribuída por uma ampla região, de serem encontradas altas concentrações de cromo nos sedimentos), são necessários estudos mais aprofundados; - não se tem conclusões relevantes se a anomalia de cromo causa problemas à saúde da população abastecida por estas águas. / The existence of chromium in groundwater is subject to great concern in the northwestern region of São Paulo State, where cities depend on the underground water resources for their only source of water to supply its needs. The aquifer system of Bauru attends with an ample demand of water the small urban centers and industries, and rural properties which need water for irrigation. This research aims to characterize the spatial extension of the chromium anomaly in groundwater in the northwestern region of São Paulo State; to develop a geochemical study of water, sediments and rocks in the city of Urânia; and to define the relation between public health and the presence of chromium in groundwater for public consumption. Initially, the chromium anomaly was discovered in shaft wells and waterholes in the Urânia municipality, Jales Region, that is to say, in some places the presence of this element exceeded the allowed maximum value in water for human consumption, which is 0.05 mg/l (State Decree 12.486, of 20-10-78 and Edict 36, of the Ministry of Health). With the chemical analysis of groundwater taken at 54 locations during 1977-1993, executed by the State Company of Basic Sanitation (SABESP), we know today that this anomaly extends to other municipalities in the northwestern region of São Paulo State. Geochemical studies in Urânia city of sediments of the Adamantina. Formation and of the basaltic rocks of the Serra Geral Formation, show that the concentrations of chromium in the first formation are above the average found in similar sediments of the earth\'s crust, and the concentrations in the basaltic rocks are lower than the average in basaltic crust. A survey to the health of the population in Urânia showed that no research was carried out in the region that would prove illness caused by the intake of water containing chromium rates above the limit for drinkability. Through the combination of data and the systematic study of chromium levels in water, sediments and rocks, the following conclusions were drawn: - the chromium anomaly is not only present in the city of Urânia, but also in other municipalities and districts in the northwest of São paulo State; - the distribution of chromium concentrations is irregular, both in time and space; - the origin of the chromium is subject to discussion, despite strong evidence that it is natural (the anomaly is distributed in a wide region, high chromium concentrations are found in the sediments), however, more in-depth studies are necessary; - no relevant conclusions can be drawn about the problems caused by the chromium anomaly to the health of the population served by this water.
115

Métodos geofísicos eletromagnéticos aplicados ao diagnóstico da contaminação do solo e das águas subterrâneas em área de infiltração de resíduos industriais / Not available.

Wagner Franca Aquino 04 April 2000 (has links)
Nos últimos anos é crescente o emprego de métodos geofísicos para diagnóstico ambiental em áreas contaminadas, uma vez que estes se têm se mostrado uma ferramenta eficiente na avaliação da contaminação do solo e das águas subterrâneas por resíduos perigosos. Neste contexto, os levantamentos geofísicos podem fornecer informações valiosas, tanto sobre a existência de contaminantes em subsuperfície, como da constituição geológica dos locais investigados. Assim, na pesquisa ora apresentada, esta metodologia foi aplicada para a avaliar da situação quanto à contaminação do solo e das águas subterrâneas em área industrial desativada, onde ocorreu a infiltração de resíduos perigosos diretamente solo. Portanto, os objetivos aqui propostos foram detectar e mapear a presença dos contaminantes em subsuperfície através do emprego de métodos geofísicos. Para tal finalidade, foram executados levantamentos eletromagnéticos utilizando-se dois métodos geofísicos distintos: o eletromagnético indutivo (EM) e o geo-radar (GPR). Os resultados obtidos por estas técnicas puderam ser comparados e correlacionados com as informações geológicas e hidrogeológicas existentes sobre o local, além de outros dados. O método eletromagnético indutivo (EM) foi empregado para se obter a condutividade elétrica aparente do terreno em diferentes profundidades de investigação, o que proporcionou o mapeamento da pluma de contaminação associada, segundo a interpretação realizada, com a presença de contaminantes inorgânicos disseminados no solo e dissolvidos na água subterrânea. O mapeamento da pluma de contaminação indicou sua abrangência fora dos limites da indústria, alcançando outras propriedades próximas porém, descartou a possibilidade de contaminação da Represa Hermínio Ometto, uma vez que o sentido de fluxo da propagação da contaminação não se observa em direção a este corpo d\'água superficial. Quanto ao método de geo-radar, devido à alta resolução fornecida por este método, foi possível imagear a contaminação presente na zona não saturada, detectar a contaminação da água subterrânea e observar a existência de um gradiente no nível d\'água identificado, confirmando as indicações do fluxo da contaminação apontadas no levantamento eletromagnético indutivo. Além disso, constatou-se a potencialidade da antena de baixa frequência (25MHz) na determinação da extensão da contaminação presente na água subterrânea. Os resultados geofísicos também foram comparados às análises químicas e às informações provenientes das descrições geológicas e das medições do nível d\'água nos poços monitorados, demonstrando uma forte correspondência entre os dados. / In the last years it has constantly increased the usage of geophysical methods in environmental evaluation of contaminated sites with hazardous waste, once they have proved to be an efficient tool in the diagnoses of soil and groundwater contamination. In this kind of application, the geophysical surveys can suply valuable information, not only on the existence of underground contamination, but also on the geological background of the investigated locations. Thus, in the study now presented, this methodolgy was applied in the evaluation of soil and groundwater contamination of an abandoned industrial area, where the hazardous wastes were infiltrated directly into the soil. Therefore, the proposed goals were to detect and map the presence of the contaminants on the subsurface, through the use of geophysical methods. For such purpose, electromagnetic surveys were conducted using two distinct geophysical methods: the inductive eletromagnetic (EM) and the ground penetrating radar (GPR). The results obtained from these techniques could be compared and correlated with the geological and groundwater data, besides others information. The inductive electromagnetic method (EM) was carried out to obtain apparent electrical conductivity of the terrain in different investigated depths, what allowed to map contaminant plume related, according to the interpretation, with the presence of inorganic compounds disseminated in the ground and dissolved in the groundwater. Mapping of the contaminant plume indicated its size to be bigger than the industry boundaries, reaching other surrounding properties, but it removed any idea of contamination of the Hermínio Ometto Dam, once the flow of the contamination was not observed to head towards this surface water source. Regarding the GPR method, due to its high-resolution results, it was possible in the sections to visualize the contaminants present in the non-saturated zone, also to the detect the possible groundwater contamination, besides to observe the existence of a gradient to water table, confirming the indications of the contamination flow pointed by the inductive electromagnetic survey. It was verified that the low frequency antenna (25MHz) is an able tool to the determine of the extension of the groundwater contamination. The geophysical results were also compared to the chemical analysis and to the information gathered from geological descriptions and also from the measurements of the water table level taken from monitored wells, demonstrating an evident correspondence between all data.
116

Avaliação da ocorrência e do transporte de microrganismos no aqüífero freático do cemitério de Vila Nova Cachoeirinha, município de São Paulo. / Assessment of occurrence and transport of microorganisms in the unconfined aquifer of Vila Nova Cachoeirinha cemetery, city of São Paulo.

Bolivar Antunes Matos 30 May 2001 (has links)
Este trabalho avaliou a ocorrência e o transporte de microrganismos no aqüífero freático do cemitério de Vila Nova Cachoeirinha, localizado em terrenos pré-cambrianos, zona norte do município de São Paulo. A metodologia aplicada foi dividida em etapas de laboratório e de campo. No laboratório, foram montadas colunas de solo do cemitério. Traçadores químico e biológico foram injetados nas colunas e o seu fluxo monitorado no efluente. Um modelo numérico foi usado para simular o transporte dos traçadores nas colunas. Em campo, foram realizadas investigações a fim de caracterizar o aqüífero freático. A monitoração da qualidade das águas foi realizada para estudar a ocorrência e o transporte de elementos químicos, bactérias e vírus nas águas subterrâneas. No cemitério, o embasamento está a cerca de 9,0 m de profundidade na cota mais baixa e 20,5 m no topo. O nível freático encontra-se entre 4 e mais de 16 m. O solo do cemitério é formado pelo material de alteração das rochas graníticas, de caráter predominantemente argiloso (~43% de argila), pH =5,0, matéria orgânica entre 0,7 e 4,2% e capacidade de troca de cátions entre 10,2 e 109,0 mmolc/kg. A condutividade hidráulica do aqüífero varia de 2,90 x 10-8 a 8,41 x 10-5 m/s. O gradiente hidráulico na porção oeste do cemitério é de aproximadamente 0,07 m/m; considerando o meio homogêneo e isotrópico e uma porosidade efetiva de 2%, a velocidade linear média foi estimada em 8 cm/dia. As amostras de água do aqüífero freático do cemitério de Vila Nova Cachoeirinha apresentaram, principalmente, bactérias heterotróficas (53 x 103 UFC/mL), bactérias proteolíticas (31 NMP/100 mL) e clostrídios sulfito-redutores (45 NMP/100 mL). Também foram encontrados enterovírus e adenovírus nas amostras. As principais fontes de contaminação das águas subterrâneas no cemitério são as sepulturas com menos de um ano, localizadas nas cotas mais baixas, próximas ao nível freático. Nestes locais, é maior a ocorrência de bactérias em geral. Há um grande consumo do oxigênio existente nas águas. As sepulturas ainda provocam um acréscimo na quantidade de sais minerais, aumentando a condutividade elétrica destas águas. Parece haver um aumento na concentração dos íons maiores bicarbonato, cloreto, sódio e cálcio, e dos metais ferro, alumínio, chumbo e zinco nas águas próximas de sepulturas. As bactérias são transportadas poucos metros, diminuindo em concentração com o aumento da distância à fonte de contaminação. Os vírus parecem ter uma mobilidade maior que as bactérias, podendo atingir algumas dezenas de metros no aqüífero freático do cemitério de Vila Nova Cachoeirinha. Os vírus foram transportados, no mínimo, 3,2 m na zona não saturada até alcançar o aqüífero. / This work assessed occurrence and transport of microorganisms in the unconfined aquifer of Vila Nova Cachoeirinha cemetery, located on pre-cambrian terrains at the northern zone of the city of São Paulo The applied methodology was divided in laboratory and field stages. In the lab, cemetery soil columns were designed; chemical and biological tracers were injected in the columns and the effluent was monitored. A numerical model was used to simulate the tracers’ transport through the columns. In the field, several investigations were done to characterize the unconfined aquifer; water quality was monitored to study occurrence and transport of chemicals, bacteria and viruses in groundwater. In Vila Nova Cachoeirinha cemetery, the depth to the bedrock is about 9.0 m at small elevation areas and 20.5 m at the top of the hill. The depth to the water table varies from 4 to over 16 m. The soil is formed by the weathered material of the granite rocks, clay content of 43%, pH = 5,0, cation exchange capacity between 10.2 and 109.0 mmolc/kg. The hydraulic conductivity of the aquifer varies from 2.90 x 10-8 to 8.41 x 10-5 m/s. The hydraulic gradient at the western part of the study area is about 0.07 m/m; considering a homogeneous and isotropic medium and an effective porosity of 2%, the average linear velocity was estimated in 8 cm/day. The water samples of the unconfined aquifer of Vila Nova Cachoeirinha cemetery presented, mainly, heterotrophic bacteria (53 x 103 UFC/mL), proteolitic bacteria (31 NMP/100 mL) and clostridium perfringes (45 NMP/100 mL). We have also found enterovirus and adenovirus in groundwater. The main sources of contamination are the within-a-year-graves located at the low elevation areas, close to the water table. At these sites, the occurrence of bacteria is greater and there is a greater consumption of oxygen in the water due to oxidation of organic matter. Moreover, the graves cause an increase in salts and electrical conductivity of the groundwater. There seems to be an increase in major ions: hydrogen carbonate, chloride, sodium, calcium; and metals: iron, aluminium, lead and zinc, next to the graves. The bacteria traveled a distance of a few meters, decreasing in concentration with increasing distance to the graves. The viruses seem to be more mobile than bacteria, they traveled distances of tens of meters at the Vila Nova Cachoeirinha cemetery. The viruses were transported at least 3.2 m through the unsaturated zone before reaching the unconfined aquifer.
117

A inserção das aguas subterraneas no sistema de abastecimento : um estudo de caso na Avenida Paulista São Paulo

Rodrigues, Francisco de Assis 19 September 2002 (has links)
Orientador : Sueli Yoshinaga Pereira / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Geociencias / Made available in DSpace on 2018-08-02T06:12:26Z (GMT). No. of bitstreams: 1 Rodrigues_FranciscodeAssis_M.pdf: 5493980 bytes, checksum: 7f922481b851bbe8f90b987a9f923975 (MD5) Previous issue date: 2002 / Resumo: O ponto de partida do presente trabalho foi a caracterização das águas subterrâneas para o abastecimento em uma área central do município de São Paulo, cuja área, além de possuir as cotas topográficas mais elevadas da cidade, assenta à Avenida Paulista, o principal centro financeiro do País. Na perspectiva de caracterização dos recursos hídricos subterrâneos, local e regionalmente, discutiu-se as condições que vêm fazendo com que esta fonte de recursos deixe de ser vista como estratégica para ser a fonte principal de abastecimento de um grande número de usuários. Para atingir tais objetivos adotou-se os seguintes procedimentos: primeiro foi realizado um levantamento de dados relacionados à exploração de águas subterrâneas, junto aos órgãos com demandas no setor, tais como a SABESP, o DAEE e os próprios usuários; segundo foi consultada a bibliografia especifica disponível sobre o assunto na RMSP, tais como teses, dissertações, relatórios técnicos, artigos de revistas, plano de recursos hídricos da BATe trabalhos de simpósios e congressos; terceiro, feito esse levantamento, foi elaborado um cronograma de trabalho que incluiu visitas aos poços cadastrados na área de estudo, onde se realizaram testes de medida de nível e de potencial de hidrogênio-pH da água. Satisfeitas estas condições, observou-se que a água subterrânea já está inserida no sistema de abastecimento, pois na área de estudo, seu uso corresponde, em média, ao atendimento de 57% das necessidades dos usuários. Por outro lado, observou-se também que a sua importância vem crescendo a cada dia em face de, pelo menos, quatro fatores, tais como os mostrados a seguir: degradação dos mananciais de superfície; custos elevados dos serviços de abastecimento e esgotamento sanitário; déficit de qualidade da água na RMSP e limitações do concessionário dos serviços para ampliar os sistemas produtores, posto que essa condição além de implicar em altos investimentos, ainda se depara com a dificuldade de encontrar um manancial que possa exportar água sem prejudicar o abastecimento da Bacia Hidrográfica onde está inserido. Por fim, este trabalho demonstrou que a água subterrânea na área estudada é, em geral, de boa qualidade, a estrutura dos poços de produção varia de usuário para usuário, as normas de utilização do recurso são cumpridas apenas parcialmente, a importância do recurso é crescente e por essa razão os órgãos competentes não podem prescindir de sua inserção, no sistema de gerenciamento de recursos hídricos / Abstract: The main motivation for this research is the characterization of groundwater resources to supply the Municipality of São Paulo. Part of the city is located at high altitude, including Paulista Avenue, the financial center of Brazil. Under the local and regional perspective of groundwater resources characterization, the research gives insights that these resources should be no longer considered as strategic source of water supply, but of fundamental importance for a large number of users. In order to achieve these goals, we have adopted procedures as: - a huge research of data related to exploration of groundwater from main database as SABESP, DAEE and even water users; - survey of literature records about the topic in the RMSP (metropolitan area of São Paulo city) , including theses, dissertations, scientific papers; - visit and monitoring of selected water producing wells in terms of groundwater level and pH. It was found that the groundwater resources corresponds to 57% of user's need. In addition, it was verified that strategic importance of the groundwater consuption has increased because: - pollution of surface water; - high cost due to supply and sanitation services; - deficit of drinking water in the RMSP and limitations of the water supplier company in providing additional volumes because of restrictions in a) investment and b) availability of water without harming the natural capability of supply of the natural hydrographic basin. Finally, this work has demonstrated that: a) the groundwater is, on average, of good quality; b) well's the quality of wel constructions changes from users; c) the legislation about the use of water has been only in part fulfilled; - since water supply is of paramount importance, the Authorities must consider its insertion in the management of water resources / Mestrado / Administração e Politica de Recursos Minerais / Mestre em Geociências
118

Análise integrada dos efeitos da expansão urbana nas águas subterrâneas como suporte a gestão dos recursos hídricos da zona norte de Natal RN

VASCONCELOS, Mickaelon Belchior 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T18:02:22Z (GMT). No. of bitstreams: 2 arquivo2516_1.pdf: 9186059 bytes, checksum: 506f3e8320706ee92f03648f4b8b9749 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A área de estudo está localizada na zona norte de Natal, totalizando 66 km2, onde 19% está favorável para ocorrência de infiltração direta de águas pluviais. Possui uma população de 300.000 habitantes, no qual o volume captado de águas subterrâneas representa 46% da demanda hídrica da população. Este trabalho tem o objetivo de verificar os efeitos da expansão urbana e realizar uma análise integrada de dados dando suporte para a gestão dos Recursos Hídricos. Com a expansão ocorrida a partir do final da década de 1970, a zona norte de Natal passou de uma zona predominantemente com vegetação nativa e agrícola para uma zona urbanizada, com algumas áreas periurbunas. A formação de centros urbanos na maioria das vezes geram impactos nas águas subterrâneas, e na cidade de Natal, isso não é diferente, onde parte da área ainda ocorre o lançamento de resíduos domésticos em fossas e sumidouros. Com isso, é gerado um aumento do processo de contaminação das águas subterrâneas, pois a geologia da área formada por sedimentos do Grupo Barreiras (cobertura residual e sedimentos eólicos) proporciona o deslocamento de contaminantes. Com pluviosidade média anual de aproximadamente 1735 mm, os dados do balanço hídrico mostram um excedente de 522,1 mm, com deficiência de 586 e uma ETP de 1799 mm. Estão inseridos na área 577 pontos d água, onde 301 são poços escavados, 06 fontes naturais e 270 são poços tubulares. Na área de estudo ocorrem aquíferos livres a semi-confinados e o fluxo subterrâneo é divergente a partir do setor central da área seguindo em direção aos rios Potengi e Doce. O balanço hidrológico mostra que ocorre uma entrada de água de 74,2×106 m3/ano e uma saída de 64×106 m3/ano, o que corresponde a um saldo positivo de 9,95×106 m3/ano. Este saldo positivo, tem que ser verificado com atenção, pois diante dos valores, existem agregados muitas incertezas hidrogeológicas que variam sazonalmente. A classificação hidroquímica possui uma diferenciação entre as águas superficiais e as águas subterrâneas. Nas águas subterrâneas, predominam amostras cloretadas, enquato nas águas superficiais apresentam-se cloretadas com uma tendência para bicarbonatada. No que refere-se aos cátions, as águas superficiais são predominantemente sódicas, enquanto que as águas subterrâneas estão amplamente divididas em sódicas e mistas, possuindo também uma amostra cálcica. Baseado em trabalhos anteriores a área possui uma transmissividade variando de 6,1×10-4 m2/s à 1,8×10-3 m2/s e a condutividade hidráulica 2,2×10-6 m/s à 6,3×10-5 m/s. A utilização da metodologia GOD na determinação da vulnerabilidade das águas subterrâneas integrada com os dados de fontes potenciais de contaminação, mostrou-se útil para a determinação do índice de risco a contaminação da águas subterrâneas. Ocorre uma predominância de risco moderado na parte central da área, com as zonas de risco forte estando localizadas as margens do rio Doce e zona do mangue. O potencial de risco baixo está isolado principalmente em decorrência da elevada profundidade do nível das águas subterrâneas. A área de estudo, em termos gerais, possui um sistema hidrogeológico em equilíbrio, pois nos últimos 10 anos não apresentou mudanças significativas na direção do fluxo das águas subterrâneas. O saldo positivo no balanço hidrológico deve ser analisado com atenção, visto que associado a estes valores, existem muitas estimativas que estão agregados as incertezas hidrogeológicas, que com a expansão urbana na área de estudo, tende a modificar a configuração da área. O adensamento populacional deve ocorrer com medidas que mantenham a sustentabilidade hídrica, evitando problemas associados. A implantação de um Plano de Gestão dos Recursos Hídricos Subterrâneos, representa uma forma de promover o desenvolvimento sustentável na área de estudo
119

Caracterização química das águas subterrâneas do aqüífero fissural do município de Iguaraci-PE

Vasconcelos Gomes Lopes, Alexandre January 2005 (has links)
Made available in DSpace on 2014-06-12T18:05:57Z (GMT). No. of bitstreams: 2 arquivo6826_1.pdf: 2522579 bytes, checksum: 8bff219cd8db1227b313cd3f1d1b7b4b (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2005 / A presente dissertação de mestrado foi realizada através de estudos das águas subterrâneas do município de Iguaraci, estado de Pernambuco. Geologicamente a área em questão, situa-se na Província Borborema, caracterizada pela predominância do macrosistema fraturado. Tem como objetivo a caracterização química dessas águas, que em sua maioria, localizam-se no aqüífero fissural. O município de Iguaraci situa-se na região fisiográfica do sertão do Pajeú, possuindo uma área de 650Km2, inserido entre as coordenadas métricas 9116000 e 9148000N e 650000 e 700000E. A metodologia utilizada constou de levantamento bibliográfico, pesquisa em trabalhos técnicos e visitas ao campo para observação da geologia e hidrogeologia. Nesta etapa foram selecionados 52 poços tubulares para posterior coleta das águas subterrâneas e análises físico-químicas no LAMSA (Laboratório de Análises Minerais Solos e Águas da UNIVERSIDADE FEDERAL DE PERNAMBUCO). Os parâmetros determinados foram: pH, condutividade elétrica, alcalinidade total e de carbonatos, dureza total, cálcio, magnésio, sódio, potássio, carbonatos, bicarbonatos e cloretos, utilizando-se a metodologia analítica do Standad Methodos For The Examination of Water and Waste Water . Com base nos resultados das análises caracterizou-se quimicamente as águas subterrâneas, elaborando-se o mapa de qualidade e uso das águas. Isto permitiu delimitar zonas hidrogeoquímicas homogêneas, para melhor aproveitamento deste manancial hídrico para os diversos usos, quer seja humano, agrícola, pecuário ou industrial. Os dados revelaram que os gnaisses apresentam águas subterrâneas de melhor qualidade, em relação aos teores de sais, enquanto os granitos mostraram valores mais elevados. Na área pesquisada ocorre a predominância das águas bicarbonatadas mistas. O pH dominante é alcalino com valor médio de 7,8. De acordo com os índices hidrogeoquímicos conclui-se que as águas subterrâneas pesquisadas são de origem continental. Pode-se afirmar que 42,3% dessas águas são inadequadas para o consumo humano, enquanto 94,24% se prestam para o consumo animal. As águas subterrâneas da região em sua grande maioria (94,24%), se enquadram na classe C3S1
120

Remediação de sitios contaminados atraves da extração de vapores do solo

Roehrig, Jackson 18 December 1991 (has links)
Orientador: Eugenio da Motta Singer / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-14T02:47:06Z (GMT). No. of bitstreams: 1 Roehrig_Jackson_M.pdf: 3444161 bytes, checksum: 01f72e9b35dc5ec3afb329fb7887e5be (MD5) Previous issue date: 1991 / Resumo: : A Extração de Vapores do Solo (EVS) é uma técnica frequentemente aplicada na remediação de zonas vadosas contaminadas por compostos voláteis, como por exemplo gasolina e solventes orgâno-clorados, bem como no controle da migração de gases, como por exemplo o metano. Consiste da formação de um gradiente de pressões no solo, responsável pelo fluxo preferencial de gases e vapores. Este trabalho apresenta as equações de fluxo de gases em meios porosos, e compara os resultados correspondentes com as equações de fluxo de águas subterrâneas.As equações de equilíbrio entre as fases do solo são analisadas a partir dos fatores que afetam a EVS. Um modelo simplificado descrevendo a extração de vapores do solo é desenvolvido a partir destas equações básicas. Considerando-se o solo homogêneo e equilíbrio instantâneo entre fases, o modelo proposto também leva em consideração os efeitos decorrentes da presença de co-solventes. Finalmente, a relevância de alguns parâmetros tais como fração de carbono orgânico, umidade do solo e fração de co-solvente é analisada a partir de um exemplo de aplicação para um caso típico... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: The Soil Vapor Extraction (EVS) is a technique frequently applied in the remediation of contaminated vadose zones by volatile compounds such as gasoline and chlorinated organic solvents, as well as on the gas migration, as methane for example. The procedure consists on creating apressure gradient in the soil, inducing preferencial flow of gases and vapours. This work presents the gas flow equations in the porous media and compares the corresponding results against established groundwater flow. The soil phase equilibrium equations are analysed under the light of the controlling factors over EVS. A simplified model describing vapour extraction is developed from those basic equations. Assuming homogeneous soil and instantaneous equilibrium amongst phases, the presently proposed model also takes into account the effects brought about by the presence of co-solvents. Finally, the relevance of some parameters such as organic carbon fraction, soil humidity and co-solvent fraction are analysed under one typical application case... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Mestre em Engenharia Civil

Page generated in 0.0766 seconds