• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

マイクロ流路の集積化と血液検査への適用に関する研究

野田, 雄一郎 25 November 2013 (has links)
京都大学 / 0048 / 新制・課程博士 / 博士(工学) / 甲第17961号 / 工博第3809号 / 新制||工||1583(附属図書館) / 30791 / 京都大学大学院工学研究科マイクロエンジニアリング専攻 / (主査)教授 小寺 秀俊, 教授 中部 主敬, 教授 岩田 博夫 / 学位規則第4条第1項該当 / Doctor of Philosophy (Engineering) / Kyoto University / DFAM
2

Microscale Tools for Sample Preparation, Separation and Detection of Neuropeptides / Mikroskaliga verktyg för provpreparering, separation och detektion av neuropeptider

Dahlin, Andreas January 2005 (has links)
<p>The analysis of low abundant biological molecules is often challenging due to their chemical properties, low concentration and limited sample volumes. Neuropeptides are one group of molecules that fits these criteria. Neuropeptides also play an important role in biological functions, which makes them extra interesting to analyze. A classic chemical analysis involves sampling, sample preparation, separation and detection. In this thesis, an enhanced solid supported microdialysis method was developed and used as a combined sampling- and preparation technique. In general, significantly increased extraction efficiency was obtained for all studied peptides. To be able to control the small sample volumes and to minimize the loss of neuropeptides because of unwanted adsorption onto surfaces, the subsequent analysis steps were miniaturized to a micro total analysis system (µ-TAS), which allowed sample pre-treatment, injection, separation, manipulation and detection. </p><p>In order to incorporate these analysis functions to a microchip, a novel microfabrication protocol was developed. This method facilitated three-dimensional structures to be fabricated without the need of clean room facilities. </p><p>The sample pre-treatment step was carried out by solid phase extraction from beads packed in the microchip. Femtomole levels of neuropeptides were detected from samples possessing the same properties as microdialysates. The developed injection system made it possible to conduct injections from a liquid chromatographic separation into a capillary electrophoresis channel, which facilitated for advanced multidimensional separations. An electrochemical sample manipulation system was also developed. In the last part, different electrospray emitter tip designs made directly from the edge of the microchip substrate were developed and evaluated. The emitters were proven to be comparable with conventional, capillary based emitters in stability, durability and dynamic flow range. Although additional developments remain, the analysis steps described in this thesis open a door to an integrated, on-line µ-TAS for neuropeptides analysis in complex biological samples.</p>
3

Microscale Tools for Sample Preparation, Separation and Detection of Neuropeptides / Mikroskaliga verktyg för provpreparering, separation och detektion av neuropeptider

Dahlin, Andreas January 2005 (has links)
The analysis of low abundant biological molecules is often challenging due to their chemical properties, low concentration and limited sample volumes. Neuropeptides are one group of molecules that fits these criteria. Neuropeptides also play an important role in biological functions, which makes them extra interesting to analyze. A classic chemical analysis involves sampling, sample preparation, separation and detection. In this thesis, an enhanced solid supported microdialysis method was developed and used as a combined sampling- and preparation technique. In general, significantly increased extraction efficiency was obtained for all studied peptides. To be able to control the small sample volumes and to minimize the loss of neuropeptides because of unwanted adsorption onto surfaces, the subsequent analysis steps were miniaturized to a micro total analysis system (µ-TAS), which allowed sample pre-treatment, injection, separation, manipulation and detection. In order to incorporate these analysis functions to a microchip, a novel microfabrication protocol was developed. This method facilitated three-dimensional structures to be fabricated without the need of clean room facilities. The sample pre-treatment step was carried out by solid phase extraction from beads packed in the microchip. Femtomole levels of neuropeptides were detected from samples possessing the same properties as microdialysates. The developed injection system made it possible to conduct injections from a liquid chromatographic separation into a capillary electrophoresis channel, which facilitated for advanced multidimensional separations. An electrochemical sample manipulation system was also developed. In the last part, different electrospray emitter tip designs made directly from the edge of the microchip substrate were developed and evaluated. The emitters were proven to be comparable with conventional, capillary based emitters in stability, durability and dynamic flow range. Although additional developments remain, the analysis steps described in this thesis open a door to an integrated, on-line µ-TAS for neuropeptides analysis in complex biological samples.

Page generated in 0.023 seconds