1 |
An evaluation of the level of naturally occuring radioactive materials in soil samples along the Chao Phraya river basinSantawamaitre, Todsadol January 2012 (has links)
The aim of this study was to evaluate the level of natural radioactivity in river sediments and riverbank surface soils collected along the Chao Phraya River and its tributaries in Thailand. The activity concentrations of naturally occurring radioactive materials in the 238U and 232Th decay chains and from 40K were determined by means of a gamma-ray spectrometry system using a hyper-pure germanium (HPGe) detector in a low background configuration. The ranges of activity concentrations of 238U, 232Th and 40K were found to be 13.9 ± 0.4 ~ 76.8 ± 1.7, 12.9 ± 0.3 ~ 142.9 ± 2.8 and 178.4 ± 6.1 ~ 810.7 ± 26.7 Bq.kg-1, respectively. The results of this current study have been compared with the world mean values of 35, 30 and 400 Bq.kg-1, respectively, specified by the UNSCEAR (2000). The artificial radionuclide, 137Cs, was not observed in statistically significant amounts above the background level in the current study. Additionally, the -, distribution of the activity concentrations to various particle sizes of soil was . investigated in this current study. It can be assumed from the results that the grain size or the fraction of sand and clay content is one of the factors that affects the activity concentrations of 238U and 232Th in the soil samples, while only a weak correlation between the activity concentration of 40K and the particle size in soil samples was observed in this current study. Concerning radiological risk to human health, the absorbed gamma dose rate (D) in air at 1 metre above the ground surface was estimated to lie in the range 21.7±0.4 to 155.7±2.2 nGy.h-1; the outdoor annual effective dose equivalent (AEDE) was evaluated to vary from 26.6±0.4 to 190.9±2.7 ~SV.il, with the arithmetic mean value of 79.06±33.23 ~Svf\ which is comparable to the worldwide effective dose of 70~Svfl. Also, the values of the Raeq and the Hex for all soil samples in the present work are lower than the accepted safety limit value of 370 Bq.ki1 and below the limit of unity, respectively. The results indicate that the radiation hazard from primordial radionuclides in all soil samples from the area studied in this current work is not significant.
|
2 |
Microsystèmes séparatifs pour l'extraction liquide-liquide des radioéléments dans les protocoles d'analyse / Separation microsystems for liquid-liquid extraction of radionuclides in the analytical proceduresHellé, Gwendolyne 14 November 2014 (has links)
L'analyse radiochimique est indispensable à de nombreuses étapes de la gestion des déchets nucléaires et du contrôle de l’environnement. Un protocole d’analyse comprend généralement plusieurs étapes de séparations chimiques longues, manuelles et difficiles à mettre en œuvre en raison de leur confinement en boite à gants. Il est nécessaire de proposer des solutions innovantes et robustes pour automatiser ces étapes mais aussi réduire le volume de déchets radioactifs et chimiques en fin de cycle analytique. Une solution consiste à miniaturiser les analyses en les réalisant en laboratoire sur puce.L’objectif de cette thèse est de proposer une approche raisonnée de la conception de microsystèmes séparatifs dédiés à l’extraction liquide-liquide de radionucléides. Pour cela le comportement hydrodynamique et les performances d’extraction dans un même microsystème ont été étudiés pour les systèmes Eu(III)-HNO3/DMDBTDMA, Eu(III)-AcO(H,Na)-HNO3/HDEHP et U(VI)-HCl/Aliquat® 336. Une méthodologie a été mise au point pour l’implémentation de l’extraction liquide-liquide en microsystème pour chaque système chimique d’extraction et la comparaison des résultats a permis de mettre en évidence l’influence du rapport des viscosités des phases sur les écoulements. Grâce à la modélisation à la fois de l’hydrodynamique et du transfert de masse en microsystème, les critères liés aux propriétés physiques et cinétiques des systèmes chimiques ont été dégagés afin de proposer une conception rationnelle de microsystèmes à façon. Enfin plusieurs exemples de mises en œuvre de l’extraction liquide-liquide en microsystème pour des applications analytiques applicables dans le domaine du nucléaire comme la séparation U/Co ou le couplage microextraction liquide-liquide/ICP-MS sont décrits. / Radiochemical analyses are necessary to numerous steps for nuclear wastes management and for the control of the environment. An analytical protocol generally includes different steps of chemical separations which are lengthy, manual and complicated to implement because of their confinement in glove boxes and because of the hostile chemical and radiochemical media. Thus there is a huge importance to propose innovative and robust solutions to automate these steps but also to reduce the volumes of the radioactive and chemical wastes at the end of the analytical cycle. One solution consists in the miniaturization of the analyses through the use of lab-on-chip.The objective of this thesis work was to propose a rational approach to the conception of separation microsystems for the liquid-liquid extraction of radionuclides. To achieve this, the hydrodynamic behavior as well as the extraction performances have been investigated in one chip for three different chemical systems: Eu(III)-HNO3/DMDBTDMA, Eu(III)-AcO(H,Na)-HNO3/HDEHP and U(VI)-HCl/Aliquat® 336. A methodology has been developed for the implementation of the liquid-liquid extraction in microsystem for each chemical system. The influence of various geometric parameters such as channel length or specific interfacial area has been studied and the comparison of the liquid-liquid extraction performances has led to highlight the influence of the phases viscosities ratio on the flows. Thanks to the modeling of both hydrodynamics and mass transfer in microsystem, the criteria related to physical and kinetic properties of the chemical systems have been distinguished to propose a rational conception of tailor-made chips. Finally, several examples of the liquid-liquid extraction implementation in microsystem have been described for analytical applications in the nuclear field: U/Co separation by Aliquat® 336, Eu/Sm separation by DMDBTDMA or even the coupling between a liquid-liquid extraction chip and the system of detection which is the ICP-MS.
|
3 |
Contribution à la réduction des pertes d'informations dans l'industrie du bois : utilisation de la Résonance Quadrupolaire Nucléaire pour l'identification de marqueurs chimiques et de la virtualisation du processus de production pour la détermination de nomenclatures divergentes / Contribution to the information loss reduction in the wood industryJover, Jérémy 13 December 2013 (has links)
La conservation des informations dans les industries dont le processus de transformation est divergent à toujours posé d'important contraintes, et l'industrie du bois n'y manque pas. Les solutions de traçabilité existantes à l'heure actuelle ne permettent pas de conserver ces informations tout au long du cycle de vie du produit bois. L'objectif de cette thèse est de montrer la faisabilité de deux concepts permettant d'améliorer la conservation de l'information : le paradigme de matière communicante et le paradigme de Virtual Manufacturing. Avec le premier paradigme, il est possible de conserver les informations relatives à l'origine du produit grâce à un marquage chimique introduit dans l'ensemble de la matière que nous identifions par Résonance Quadrupolaire Nucléaire. Dans le deuxième paradigme pour anticipons les caractéristiques biométriques des produits finaux en numérisant la matière et en virtualisant les opérations de transformation. Grâce à cela, il est possible de déterminer, malgré l'imperfection des données et des décisions les caractéristiques des produits / Information conservation in the divergent process has always imposed important constraints. In the Wood industry, in which the problem is present, has no solution to conserve information all along the wood life cycle. This thesis goal is to validate the use of two new paradigms allowing improving the information conservation: the communicating material and the virtual manufacturing. With the first one, the wood material is intrinsically marked with chemical product which can be identify with the Nuclear Quadrupole Resonance and allow conserving the material origin. With the second one, it is possible to anticipate sawmill production by foresee the final product characteristics
|
Page generated in 0.0199 seconds