• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Βελτιστοποίηση της έκθεσης του αξονικού τομογράφου σε παιδιατρικές εξετάσεις / Paediatric computed tomography exposure optimization

Τζιωρτζή, Άντρη 15 December 2008 (has links)
The utilization of Computed Tomography in paediatric examinations constantly increases. During the procedure, a high amount of dose is delivered to children, which could be avoided. This study examined whether the selection of scanning parameters – tube voltage and tube current-time product- could be based on patient size instead of patient age or weight aiming, for dose reduction. The SRS78 spectrum processor software was employed to generate spectra with tube voltage between 80kVp and 120kVp and with tube current-time product between 50mAs and 165mAs. These spectra were attenuated by different thicknesses of polymethylmethacrylate (PMMA) phantoms. The simulation technique was validated with experimental measurements acquired on CTDI phantoms on a Siemens Somatom plus 4 scanner. The image quality was assessed in terms of noise, contrast and contrast-to-noise ratio (CNR). Furthermore the contrast of iodine, adipose tissue and cortical-bone relative to muscle were calculated in order to examine how the contrast of different materials was influenced when tube voltage changed. The data analysis shows that there is a definite relationship between image quality and the size of a patient. When exposure settings are kept constant, the level of noise, contrast and Contrast-to-Noise Ratio (CNR) depends on the size of the phantom. Noise is increased exponentially and contrast is reduced linearly as the size of the phantom is increased. CNR is markedly higher in small size phantoms. Moreover, when tube voltage was reduced the noise level was increased less in the small size phantoms and the contrast of high atomic number materials is reduced more when tube voltage is reduced. The CNR for high atomic number materials presents modest improvements when tube voltage is increased therefore examinations with contrast agents could be performed at lower tube voltages. Furthermore the high CNR in small size phantoms could be traded off with lower mAs. In particularly the mAs could be reduced by up to 95% while maintaining the same CNR as for adults resulting in dramatic dose reductions for children. Moreover, since Computed Tomography stands out from all the other X-ray techniques due to its ability to detect structures of similar densities the detect ability of low contrast details was investigated. The Catphan phantom and particularly the CTP515 module was employed. The phantom was scanned with the Siemens Somatom plus 4 scanner at 80kVp, 120kVp and 140kVp and with tube current-time product between 43mAs and 165mAs. The image quality was assessed subjectively and objectively. It is observed that when 120kVp and 140kVp are applied there are not sufficient differences on image quality which justify the selection of 140kVp in paediatric protocols. When 80kVp is applied structures with contrast lower than 10HU are not detected. Concerning mAs does not contribute to the detection of low contrast details except if it is combined with high tube voltages. However, mAs contribute to the visualisation of smaller in size details but above a threshold value, higher mAs does not serve any purpose and the value of 300mAs employ in many protocols is not justified. In conclusion, the reduction of dose during paediatric Computed Tomography examinations is more than probable since scanning parameters could be reduced without degradation of image quality. However in order to assure the reduction of dose without side effects, protocols must be constructed which will individualize the Computed Tomography examinations. That is, the optimum spectrum must be selected relative to the diagnostic task and the size of the patient. / -
2

Optimisation et réduction de la dose d’irradiation au scanner : aspects techniques et impact en pratique clinique courante / CT radiation dose optimization and reduction : technical aspects and impact in clinical pratice

Gervaise, Alban 03 October 2016 (has links)
Depuis son introduction dans les années 1970, le scanner est devenu une technique d’imagerie médicale incontournable grâce à son excellente performance pour le diagnostic de nombreuses pathologies. Toutefois, le scanner est un examen d’imagerie irradiant. Compte-tenu des risques potentiels de cancer radio-induit liés aux faibles doses de rayons X, la réduction de la dose d’irradiation au scanner est primordiale. Dans ce travail, nous avons étudié plusieurs facteurs techniques et comportementaux qui permettent d’optimiser et de réduire la dose d’irradiation au scanner, tout en préservant une excellente performance diagnostique. Du côté des facteurs comportementaux, la sensibilisation des équipes médicales et paramédicales est fondamentale dans une démarche d’optimisation de la dose d’irradiation au scanner. De même, la limitation du nombre de phases d’acquisition et la réduction de la couverture d’acquisition sont deux manières simples pour réduire les doses délivrées. Du côté des facteurs techniques, nous avons montrés que l’utilisation des reconstructions itératives, par rapport aux reconstructions standards en rétroprojection filtrée, permet de réduire de moitié la dose d’irradiation des scanners, à qualité d’image équivalente. L’acquisition en mode volumique pour les scanners avec une faible couverture d’acquisition et l’utilisation de la modulation automatique du milliampérage permettent aussi de réduire et d’optimiser les doses. Enfin, nous nous sommes intéressés à l’optimisation de protocoles de scanner en pratique clinique courante en se focalisant sur les scanners réalisés pour la recherche d’une colique néphrétique et pour les scanners en imagerie ostéo-articulaire. Dans ce dernier domaine, nous avons aussi proposé des protocoles de scanner pour des applications cliniques avancées comme le scanner dynamique des articulations ou le scanner de perfusion tumorale / Since its introduction in the 1970s, computed tomography (CT) has become the technique of reference in medical imaging for many diseases due to its high diagnostic performance. Its main limitation is the radiation dose delivered to the patient. Considering the potential risks of radiation-induced cancer caused even with low dose exposure, dose reduction in CT is essential. In this work, we studied several technical and behavioral factors that allow for CT radiation dose reduction and optimization, without modifying the diagnostic performance. Among the behavioral factors studied, education and awareness of radiologists and radiology technicians are important elements for CT radiation dose reduction. Limiting CT scan coverage and the number of acquisition phases is also a straightforward and effective way to reduce dose exposure. Regarding technical factors, we have shown that iterative reconstruction algorithms can reduce in half the radiation dose in comparison with standard filtered back projection, while maintaining equivalent image quality. The use of wide volume mode for acquisitions with a short coverage and the use of the automatic tube current modulation can also be used to reduce and optimize CT radiation dose. Finally, we provide guidelines to optimize CT radiation dose in some clinical settings such as renal colic and musculoskeletal CT. We also propose practical guidelines for advanced clinical applications of joint dynamic CT and perfusion CT in musculoskeletal disease
3

Stratégies d’optimisation des protocoles en scanographie pédiatrique / Optimization Strategies on pediatric CT Protocol

Rani, Kaddour 14 December 2015 (has links)
Depuis le début des années soixante-dix, le nombre de scanners par hôpitaux n’a fait qu’augmenter et leur utilisation est de plus en plus fréquente. Même si cette technique permet de donner des informations cliniques précieuses, elle a un revers qui est l’exposition du patient à des rayonnements ionisants. La sensibilité des enfants aux rayonnements est plus grande que celle des adultes, les enfants ont une espérance de vie importante et ont donc plus de risques de développer des cancers dans le futur. Il y a donc nécessité de tenter de réduire la dose au patient. Cette thèse vise donc à développer des stratégies d’optimisation sur les protocoles cliniques en utilisant des méthodes de simulation et de modélisation permettant de comprendre l’influence des paramètres des protocoles sur les indicateurs de qualité d’image et sur la dose délivrée au patient. Ce travail se divise en quatre parties: La première partie porte sur la modélisation de l’influence des paramètres des protocoles scanographiques sur deux indicateurs de qualité d’image et un indicateur de dose en utilisant la méthodologie des plans d’expériences. La seconde partie traite du développement d’un Protocole Générique Optimisé (PGO) pour la région de l’abdomen. A partir des données des modèles développés, un PGO recalculé pour cinq morphologies de patients pédiatriques et pour quatre modèles de scanners a été réalisé. L’ensemble des résultats, ont permis le développement d’un outil d’aide à l’optimisation permettant à l’utilisateur de générer un protocole optimisé en fonction du modèle de scanner et de la morphologie du patient. / For the last 10-years, computed tomography (CT) procedures and their increased use have been a major source for concern in the scientific community. This concern has been the starting point for several studies aiming to optimize the dose while maintaining a diagnostic image quality. In addition, it is important to pay special attention to dose levels for children (age range considered to be from a newborn baby to a 16-y-old patient). Indeed, children are more sensitive to ionizing radiations, and they have a longer life expectancy. Optimizing the CT protocols is a very difficult process due to the complexity of the acquisition parameters, starting with the individual patient characteristics, taking into account the available CT device and the required diagnostic image quality. This PhD project is contributing to the advancement of knowledge by: (1) Developing a new approach that can minimize the number of testing CT scans examinations while developing a predictive mathematical model allowing radiologists to prospectively anticipate how changes in protocols will affect the image quality and the delivered dose for four models of CT scan. (2) Setting-up a Generic Optimized Protocol (based on the size of the phantom CATPAHN 600) for four models of CT scan. (3) Developing a methodology to adapt the GOP to five sizes of pediatric patient using Size Specific Dose Estimate calculation (SSDE). (4) Evaluating subjective and objective image quality between size-based optimised CT protocol and age-based CT protocols. (5) Developing a CT protocol optimization tool and a tutorial helping the radiologists in the process of optimization.
4

Διόρθωση της εξασθένησης της γ-ακτινοβολίας (attenuation correction) μέσω υπολογιστικής αξονικής τομογραφίας (CT) χαμηλής ευκρίνειας σε τομογραφικές (SPECT) σπινθηρογραφικές μελέτες αιμάτωσης μυοκαρδίου. Διαγνωστική και προγνωστική αξία

Σαββόπουλος, Χρήστος 07 May 2015 (has links)
Η διερεύνηση της διαγνωστικής και προγνωστικής αξία της διόρθωσης φωτονιακής εξασθένησης με χάρτες μέσω CT χαμηλής δόσης και ευκρίνειας στη στεφανιαία νόσο. ΠΕΙΡΑΜΑΤΙΚΟ ΣΚΕΛΟΣ Υλικό και Μέθοδος: Σε ομοίωμα Data Spectrum πραγματοποιήθηκαν SPECT/CT απεικονίσεις με 201Tl & 99mTc αφενός χωρίς ελλείμματα στο καρδιακό ένθεμα όπου μετρήθηκε ομοιογένεια εικόνας και κρούσεις και αφετέρου με την τοποθέτηση ελλειμμάτων, «διατοιχωματικών» & «υπενδοκαρδίων» όπου υπολογίστηκαν το μέγεθος (FWHM) και η αντίθεση του ελλείμματος. Κατόπιν οι AC & NAC απεικονίσεις συνεκρίθησαν κατά ζεύγη ως προς τις προαναφερθείσες παραμέτρους. Αποτελέσματα: Στις μετρήσεις χωρίς έλλειμμα ευνοήθηκε η μέθοδος με διόρθωση (AC) αυξάνοντας την ομοιογένεια της φυσιολογικής εικόνας και εξομαλύνοντας το λόγο κρούσεων κατωτέρου/προσθίου τοιχώματος. Στις απεικονίσεις με έλλειμμα η AC μέθοδος εμφάνισε καλύτερο FWHM ενώ η τεχνική χωρίς διόρθωση εξασθένησης (NAC) αποδείχθηκε ανώτερη ως προς την αντίθεση του ελλείμματος. ΔΙΑΓΝΩΣΤΙΚΟ ΣΚΕΛΟΣ Υλικό και Μέθοδος: Διερευνήθηκαν αναδρομικώς 120 εξεταζόμενοι χαμηλού pre-test κινδύνου ΣΝ με αρνητικούς κλινικούς δείκτες και 120 πρώϊμα στεφανιογραφηθέντες (<60 ημέρες μετά MPI με 201Tl + CT-AC). Οι AC & NAC εικόνες εκτιμήθηκαν τυφλά τόσο ποιοτικά όσο και ημιποσοτικά (Summed Stress Score - SSS, Summed Difference Score - SDS). Κατόπιν, υπολογίστηκε το normalcy στον πληθυσμό χαμηλού κινδύνου ενώ στους στεφανιογραφηθέντες με gold standard τα αγγειογραφικά δεδομένα υπολογίστηκαν ευαισθησίες, ειδικότητες και διαγνωστικές ακρίβειες στο γενικό πληθυσμό και κατά φύλο στην επικράτεια του LAD και του συνδυασμού RCA/LCx οι οποίες συνεκρίθησαν με τη McNemar δοκιμασία. Τέλος, σχεδιάστηκαν ROC καμπύλες και έγινε σύγκριση μεταξύ τους κατά ζεύγη. Αποτελέσματα: Στον πληθυσμό χαμηλού κινδύνου η AC τεχνική υπερίσχυσε στο normalcy, ενώ στους στεφανιογραφηθέντες στατιστική σημαντικότητα παρατηρήθηκε στην περιοχή κατανομής της RCA/LCx στο γενικό πληθυσμό και στους άνδρες, όπου η NAC μέθοδος ήταν πιο ευαίσθητη και η AC πιο ειδική, χωρίς να προκύψουν στατιστικώς σημαντικά αποτελέσματα κατά τις συγκρίσεις ως προς τη διαγνωστική ακρίβεια και στις κατά ζεύγη συγκρίσεις των AUC στις ROC καμπύλες. ΠΡΟΓΝΩΣΤΙΚΟ ΣΚΕΛΟΣ Υλικό και Μέθοδος: Πρόκειται για προοπτική μελέτη με 637 συμμετέχοντες στους οποίους πραγματοποιήθηκε SPECT/CT απεικόνιση ρουτίνας και εκτιμήθηκαν ημιποσοτικά οι AC & NAC εικόνες (SSS – τυφλή ανάλυση). Μετά από κλινική παρακολούθηση κατεγράφησαν οι θάνατοι (πρωτεύον καταληκτικό σημείο), καθώς και οι συνδυασμοί θανάτων/ΟΕΜ και θανάτων/ΟΕΜ/οψίμων επαναγγειώσεων (δευτερεύοντα καταληκτικά σημεία). Κατόπιν, ορίστηκαν διαχωριστικές SSS τιμές του πληθυσμού βάσει της συχνότητας συμβαμάτων, και σχεδιάστηκαν Kaplan-Meier καμπύλες επιβίωσης στο γενικό πληθυσμό και στις SSS υποομάδες (AC & NAC) οι οποίες συνεκρίθησαν μεταξύ τους με την LogRank μέθοδο. Τέλος, οι κλινικές και απεικονιστικές παράμετροι αξιολογήθηκαν με την Cox μέθοδο, τόσο στο μονοπαραγοντικό (univariate) μοντέλο όσο και στην πολυπαραγοντική ανάλυση παλινδρόμησης (multivariate regression analysis). Αποτελέσματα: Κατά τη διάρκεια της κλινικής παρακολούθησης (ѱSD = 42.3±12.8 μήνες) σημειώθηκαν 24 θάνατοι (7 καρδιογενείς), 13 ΟΕΜ και 28 επαναγγειώσεις. Από την κατηγοριοποίηση του πληθυσμού προέκυψαν τρεις SSS υποομάδες για κάθε μέθοδο: 0-4, 5-13 και >13 (NAC) και 0-2, 3-9 και >9 (AC). Στην Kaplan-Meier ανάλυση η NAC παρήγαγε στατιστικώς σημαντικά αποτελέσματα μεταξύ των ομάδων 5-13 και >13 ως προς θανάτους και μεταξύ όλων των SSS υποπληθυσμών για αμφότερα τα δευτερεύοντα καταληκτικά σημεία, ενώ η AC κατάφερε να διαχωρίσει μεταξύ 0-2 & >9 ως προς θανάτους/ΟΕΜ και 0-2 & 3-9 ως προς συνολικά συμβάματα. Στο μονοπαραγοντικό Cox μοντέλο η NAC απεικόνιση κατάφερε στατιστική σημαντικότητα τόσο για SSS>4 όσο και >13 ως προς όλα τα καταληκτικά σημεία με την AC να παρουσιάζει ανάλογα αποτελέσματα για SSS>2 ως προς μείζονα και συνολικά συμβάματα και για SSS>9 ως προς το σύνολο των συμβαμάτων. Τέλος, στην πολυπαραγοντική ανάλυση παλινδρόμησης, η NAC αποδείχθηκε ανεξάρτητη προβλεπτική παράμετρος για θανάτους/ΟΕΜ και σύνολο συμβαμάτων, ενώ στην AC δεν παρατηρήθηκαν στατιστικώς σημαντικά αποτελέσματα. Συμπέρασμα: Η διόρθωση φωτονιακής εξασθένησης μέσω χαρτών εξασθένησης με CT δεν φαίνεται να προσαυξάνει τη διαγνωστική ακρίβεια ή την προγνωστική ισχύ του SPECT αιματώσεως μυοκαρδίου και η ανεπίλεκτη χρησιμοποίησή της στην κλινική πράξη μπορεί να οδηγήσει σε υποεκτίμηση της στεφανιαίας νόσου και του κινδύνου καρδιακών συμβαμάτων που αυτή συνεπάγεται. / To investigate the diagnostic and prognostic value of photon attenuation correction through maps derived from low-dose/low-resolution CT in coronary artery disease. EXPERIMENTAL PART Materials and Methods: SPECT/CT 201Tl and 99mTc imaging was performed on a Data Spectrum torso phantom, firstly without “myocardial” defects (assessment of overall and regional image uniformity and counts) and afterwards with the insertion of “subendocardial” and “transmural” defects (measurement of defect FWHM and contrast); subsequently, attenuation corrected (AC) & non-corrected (NAC) images were compared pairwise as regards the aforementioned parameters. Results: AC was favoured in the measurements without defects by increasing image uniformity and optimizing inferior-to-anterior wall count ratio. When defects were imaged, AC was superior at the assessment of FWHM whereas NAC achieved better defect contrast. DIAGNOSTIC PART Materials and Methods: One-hundred and twenty patients with negative clinical markers for CAD as well as 120 patients (90 males, 30 females) who were subjected to coronary angiography within 60 days post-MPI (201Tl SPECT/CT) were retrospectively reviewed. AC & NAC images were evaluated blindly both qualitatively and semi-quantitavely (Overall Summed Stress Score – SSS & Summed Difference Score – SDS as well as corresponding scores for LAD and RCA/LCx vascular domains). In the low-risk population, AC & NAC normalcy rate was assessed and in the population with angiographic reference sensitivity, specificity and diagnostic accuracy were calculated for both AC & NAC MPI which were compared with the McNemar test. Finally, ROC curves were created and the AUC were compared. Results: In the low-risk population AC increased normalcy rate while in the patients with angiographic correlation statistically significant results were obtained in the general and male population in the RCA/LCx territory, where NAC was more sensitive and AC displayed higher specificity without any significant results as regards diagnostic accuracy or ROC AUC comparisons. PROGNOSTIC PART Materials and Methods: 637 unselected patients underwent 201Tl MPI with CT-AC. AC & NAC images were interpreted blindly and summed stress scores (SSS) were calculated. Study endpoints were all-cause mortality and the composites of death/non-fatal acute myocardial infarction (AMI) and death/AMI/late revascularization. On the basis of the event rate distribution across SSS values SSS subgroups were created, Kaplan-Meier curves were drawn and compared by the use of the LogRank test and finally clinical and scintigraphic parameters were entered into the univariete and multivariate Cox regression model. Results: During a follow-up of 42.3±12.8 months 24 deaths, 13 AMIs and 28 revascularizations were recorded. Prognostic SSS groups formed were: 0-4,5-13,>13 for NAC and 0-2,3-9,>9 for AC. Kaplan-Meier functions were statistically significant between NAC SSS groups for all study endpoints. AC discriminated only between SSS 0-2 and >9 for death/AMI and between 0-2 and 3-9 for death/AMI/revascularization. In the univariate Cox regression, abnormal NAC achieved statistical significance for all endpoints whereas AC managed to do so only for SSS >2 & >9 regarding major and all events and for SSS>9 as regards all events. In the multivariate model, abnormal AC yielded no significance for either endpoint whereas abnormal NAC proved independent from other covariates for the composite endpoints. CONCLUSION: Photon attenuation correction with the use of CT-derived attenuation maps does not seem to increase the diagnostic accuracy or prognostic value of myocardial perfusion SPECT and its non-selective utilization in clinical practice may lead to underestimation of coronary artery disease and the subsequent risk of cardiac events.

Page generated in 0.0412 seconds