• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Performance evaluation of reversible heat pumps when using refrigerant mixtures

Leelananda, Rajapaksha Kankanamge January 2003 (has links)
No description available.
2

Impact of widespread adoption of heat pumps on power system operation

Akmal, Muhammad January 2011 (has links)
The thesis involves research on power system operation, under high wind penetration, using controllable heat pump loads. The work used experimental measurements from the test rig of an underfloor heating arrangement supplied from an air-source heat pump in the Renewable Energy Laboratory at Queen's University Belfast. LabVIEW based data acquisition was used for experimental assessment of various aspects of the operation of the heat pump as an electrical load. Electric heat profile along with electric demand has been scheduled with generation portfolios for the best utilization of heat pump loads using the WILMAR planning tool for network integration of significant wind power. Three scenarios (peak shifting, following wind and following price) are examined to encourage more wind penetration and to ease system operation and the results are compared with the base case. The results show a significant decrease in the system operational cost, with fewer unit start-ups and less wind curtailment. The use of emergency reserve from heating load can lead to enhancement of system performance, by reducing operating cost, fewer unit start-ups and improving capacity factors of efficient plant technologies. A thermal model of the heating system is also developed and different control strategies are applied to maintain building temperatures while using thermal load for user comfort and demand-side management for supporting power system operation. Building temperature variations are also determined for different control strategies. Then a dynamic simulation model for the heat pump is developed for low-voltage network studies. The developed model is used for high penetrations of heat pump loads in low-voltage grids using the DlgSILENT software package. It was found that the typical distribution network can accommodate a certain percentage of heat pumps, provided that the heat pumps employ soft-starters and the network is not overloaded. Power quality criteria are just satisfied under these circumstances. The work concludes that well-controlled heat pumps have a good potential to support the operation of power systems with highly variable renewable generation, making use of thermal storage, provided the low-voltage networks allow their installation.
3

Etude expérimentale de cycles de pompe à chaleur utilisant des mélanges à base de CO2 / Experimental study of heat pump thermodynamic cycles using CO2 based mixtures

Bouteiller, Paul 06 April 2017 (has links)
Cette étude consiste en l’expérimentation de mélanges de fluides frigorigènes à base de CO2 dans les applications de pompes à chaleur domestiques. L’objectif est l’obtention de performances supérieures à une pompe à chaleur au CO2 double-service (eau chaude sanitaire et chauffage). L’ajout d’autres composés au CO2 déplace le point critique et de façon plus générale modifie les lignes d’équilibre de phases. On peut alors s’attendre à la réduction des pressions de fonctionnement et à une augmentation du rendement énergétique du cycle thermodynamique. Une pompe à chaleur mono-étagée au CO2 est utilisée comme référence, et les conditions de température externes à la boucle thermodynamique sont invariantes. Deux scénarii sont considérés : La production d’eau chaude sanitaire (ECS), où l’eau est chauffée de 10 °C à 65 °C ; la production d’eau de chauffage (CH) où l’au est chauffée de 30 °C à 35 °C. Dans les deux cas, l’eau glycolée en l’entrée de l’évaporateur est régulée à 7 °C. Afin de pouvoir analyser le comportement des cycles thermodynamiques avec mélanges, il est essentiel de connaitre la composition du fluide frigorigène en circulation. Pour ce faire, nous avons mis au point une technique de mesure statistique et non-intrusive de la composition: Des cellules optiques installées sur les tubes de la boucle permettent de recueillir les spectres d’absorption du fluide en circulation, grâce à un spectromètre proche infrarouge à transformée de Fourier. Un étalonnage méticuleux est effectué via l’acquisition de nombreux spectres d’échantillons ayant des compositions connues. Un modèle statistique est alors créé pour lier les concentrations aux données spectrales. Les compositions peuvent ensuite être estimées à partir de nouveau spectres, dont l’acquisition rapide permet l’analyse de la composition du fluide même en fonctionnement dynamique de la pompe à chaleur. Des mélanges de CO2 & propane, et CO2 & R-1234yf ont été testés, montrant des potentiels d’amélioration des performances de la pompe à chaleur pour les applications de chauffage des locaux. / The aim of this work is to experiment CO2 based mixtures as working fluids for heat pump applications in buildings, in order to enhance their performances compared to pure CO2 dual services heat pumps. Since adding other chemicals to CO2 moves the critical point and generally equilibrium lines, it is expected that lower operating pressures as well as higher global efficiencies can be reached. A simple stage pure CO2 cycle is used as reference, with fixed external conditions. Two scenarios are considered: water is heated from 10 °C to 65 °C for Domestic Hot Water (DHW) scenario and from 30 °C to 35 °C for Central Heating (CH) scenario. In both cases, water at the evaporator inlet is set at 7 °C to account for such outdoor temperature conditions. In order to understand the dynamic behaviour of thermodynamic cycles with mixtures, it is essential to measure the fluid circulating composition. To this end, we have developed a non intrusive method. Online optical flow cells allow the recording of infrared spectra by means of a Fourier Transform Infra Red spectrometer. A careful calibration is performed by measuring a statistically significant number of spectra for samples of known composition. Then, a statistical model is constructed to relate spectra to compositions. After calibration, compositions are obtained by recording the spectrum in few seconds, thus allowing for a dynamic analysis. Mixtures of CO2 & propane and CO2 & R-1234yf have been tested and showed great potential on enhancing performances of the heat pump for central heating applications.
4

Étude et conception d'une pompe à chaleur intégrée dans le procédé d'épuration du biogaz / Study and design of a heat pump integrated in a biogas upgrading process

Keryakos, Elie 05 May 2017 (has links)
L’engagement de l’Europe sur les énergies renouvelables amène à l’accélération du développement du biométhane comme énergie renouvelable. Les travaux de cette thèse portent sur une partie du procédé Cryo Pur qui est un procédé essentiellement frigorifique qui va permettre en refroidissant le biogaz de la température ambiante à -120 °C, de séparer successivement l’eau, le CO2 et des polluants pour obtenir du méthane et du CO2 liquides de hautes puretés. Les objectifs poursuivis sont méthodologiques et expérimentaux. La méthode est celle de l’intégration énergétique associée à une analyse exergétique du procédé. L’analyse intègre la production frigorifique et la production de chaleur par les groupes frigorifiques pour son utilisation dans le procédé de méthanisation. L’optimisation énergétique part de l’analyse exergétique et identifie les pertes des différentes étapes du procédé et intègre à la fois les productions frigorifiques aux différents niveaux de température et la production de chaleur utilisée dans le digesteur. Le besoin en chaleur du digesteur se situe autour de 50 à 55 °C pour les bactéries thermophiles. Pour l’épuration du biogaz et la liquéfaction du biométhane, les besoins frigorifiques se situent de la température ambiante jusqu’à-120 °C. Dans le procédé Cryo Pur, la production frigorifique s’effectue à 4 niveaux de températures : 2°C, -40 °C, -78 °C et -120 °C. La pompe à chaleur est couplée aux différents systèmes frigorifiques en refroidissant un frigoporteur à une température qui fait l’objet de l’optimisation globale du système de thermo-frigo-pompe. En effet la pompe à chaleur refroidit les condenseurs des 4 systèmes frigorifiques et la chaleur récupérée des groupes froids est valorisée à 55 °C par la pompe à chaleur.Complémentairement à cette optimisation énergétique globale, la thèse se focalise sur le givrage et dégivrage de l’eau contenue dans le biogaz. Cette opération consomme beaucoup d’énergie et un travail d’optimisation énergétique est mené pour minimiser la consommation d’énergie pour la déshumidification du biogaz de la température ambiante à -78 °C. La représentation des cycles associés au givrage et dégivrage de la glace hydrique et des pertes associées aux montées et descentes en température des masses métalliques des échangeurs requière une modélisation dynamique de ces phénomènes. Du point de vue expérimental les cycles de givrage et dégivrage de l’eau font l’objet d’une optimisation quant à leur gestion.Les travaux de la modélisation donneront lieu à dimensionner les échangeurs des cycles de givrage et de dégivrage. Le but finalement étant l’obtention d’un rendement exergétique le plus élevé possible. Les essais ont permis de valider les modèles d’échangeurs et des systèmes frigorifiques. L’optimisation intègre également le choix des mélanges des fluides frigorigènes. / Europe's commitment to renewable energy leads to accelerate the biomethane development as a renewable energy. The work of this thesis is based on the Cryo Pur process which is essentially a cooling process that will allow the biogas cooling from ambient temperature to -120 °C. While cooling the biogas, water vapor, CO2 and pollutants must be separated to obtain liquefied biomethane and bio CO2. The objectives pursued are methodological and experimental. The method used is the energy integration associated with an exergy analysis of the process. The analysis integrates the cooling production and the heat production by the refrigeration units for the use in the methanisation process. The energy optimization starts from the exergy analysis and identifies the losses of the various stages of the process and integrates both the cooling production at different temperature levels and the heat production used in the digester. The heat requirement of the digester is around 50 to 55 °C for the thermophilic bacteria. For the biogas upgrading and the liquefaction of biomethane, the cooling requirements are from ambient temperature to -120 °C. In the Cryo Pur process, refrigeration is carried out at 4 different temperature levels: 2 °C, -40 °C, -78 °C and -120 °C. The heat pump is coupled to the various refrigeration systems by cooling a refrigerant at a temperature which is the objective of the overall optimization of the heat pump system. The heat pump cools the condensers of the 4 refrigeration systems and the heat recovered from the refrigeration systems is upgraded to 55 °C by the heat pump.In addition to this overall energy optimization, the thesis focuses on the frosting and defrosting of the water contained in the biogas. This operation consumes a lot of energy. An energy optimization work is carried out to minimize the energy consumption for the dehumidification of biogas from ambient temperature to -78 ° C. The representation of the frosting and defrosting cycles and the losses associated with the temperature of the metallic mass of the heat exchangers requires a dynamic modeling. The dynamic modeling will lead to design the heat exchangers. The ultimate aim is to achieve the highest possible exergy efficiency. Tests made it possible to validate the models of the heat exchangers and refrigeration systems. The optimization also integrates the choice of refrigerant mixtures.

Page generated in 0.0178 seconds