• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 122
  • 13
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

A peroxide sensor for the food and beverages industry

Moody, A. P. January 2002 (has links)
No description available.
52

Accelerated testing of synthetic flexible leaflet heart valves

D'Souza, Selwyn Stephen January 2002 (has links)
No description available.
53

An automated diagnostic system for tubular carcinoma of the breast : a model for computer-based cancer diagnosis

Leong, F. Joel W-M. January 2002 (has links)
No description available.
54

Aspects of the development of British scientific instrument making in the second half of the nineteenth century

Meliconi, Ilaria January 2003 (has links)
No description available.
55

Computational methods of design by analysis for pressure vessel components

Muscat, Martin January 2002 (has links)
No description available.
56

Monte Carlo computing applied to X-ray room design

McVey, Graham Hugh January 2002 (has links)
Currently, x-ray rooms are designed by employing measured scatter and transmission data obtained nearly thirty years ago. Subsequently, there is a clear need to reevaluate this information as the use of modern equipment is becoming increasingly common. For example, x-ray tubes with medium frequency generators are replacing single phase units. Recent literature has re-evaluated transmission data. However, the scatter found in x-ray rooms has not been studied in detail. Two programs using Monte Carlo techniques have been developed for this purpose. The first program models the x-ray room including a slab phantom simulating the patient, a DAP meter, air and the room walls. The second program implements a realistic model of a patient in the imaging system. The results of the two programs have been validated by comparison with each other and by measurements. The results confirm that the patient is the primary source of scatter in a x-ray room. However, large variations in the scatter values are observed for different x-ray examinations and when the imaging parameters are changed. The results also show that there is a significant scatter contribution from other materials in the primary xray beam including the air, DAP meter and x-ray collimators. The first program has been used to calculate the scatter at a door positioned behind a protective screen at the radiographer's console. It predicts that no shielding in the door is required for the imaging system investigated. Therefore, a valuable computational tool has been developed which will aid the decision process in the design of clinical x-ray rooms.
57

Fatigue behaviour of hydrostatically extruded HAPEX

McGregor, William John January 2001 (has links)
No description available.
58

Design and development of a CD-based diagnostic system

Campbell, Aileen Margaret January 2002 (has links)
No description available.
59

The design and development of devices for aerial pollution abatement

Lewis, Andrew January 2002 (has links)
No description available.
60

Development of a gas-phase biosensor for exposure measurement

Sandström, Mattias January 2002 (has links)
No description available.

Page generated in 0.0133 seconds