• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • Tagged with
  • 18
  • 18
  • 7
  • 7
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo do eletrocardiograma sob uma abordagem matemática. / Electrocardiogram evaluation under a mathematical approach.

Melco, Tito Coutinho 10 November 2006 (has links)
O eletrocardiograma transMITe informações com relação à passagem do pulso elétrico pelo coração e, conseqüentemente, do funcionamento deste. Desde o início da sua utilização, possibilitada pelo trabalho de Willem Einthoven criando a primeira máquina capaz de medir o pulso elétrico de forma não invasiva e com sensibilidade forte o bastante para ser capaz de produzir um gráfico proveitoso, o eletrocardiograma é muito utilizado para avaliação clínica de pacientes. Entretanto a evolução das máquinas que o descrevem não foi muito além do que o elaborado por Einthoven no início do século 20. As máquinas capazes de captar o eletrocardiograma se tornaram menores (até portáteis para algumas aplicações), gráficos passaram a ser disponibilizados em telas de vídeo (ao invés das fitas de papel) e, como maior evolução, as máquinas que observam o eletrocardiograma passaram a conseguir captar a ocorrência de um ciclo cardíaco com alta confiabilidade e, atualmente, passaram a medir também o parâmetro ST com precisão deliMITada (necessitando ajuda do operador para ajuste em alguns casos). É baseado nestes fatos que esta dissertação procura estudar algoritmos matemáticos, de forma mais focada nos modelos do impulso elétrico durante os ciclos cardíacos, e avaliar suas capacidades de interpretar parâmetros do ciclo de ECG de forma precisa e rápida para que o médico tenha prontamente os dados necessários para realizar a avaliação clínica do paciente. Em primeira análise foram estudados os algoritmos para detecção do pulso de eletrocardiograma (detecção da onda R), em seguida feito o janelamento da curva de ECG a fim de separar os ciclos cardíacos. A partir deste ponto foram analisados os modelos matemáticos gerados por equações polinomiais, Transformada de Fourier e Transformada wavelet. E, com o intuito de filtrar ruídos e gerar derivações não medidas, foi implementado um filtro de kalman em um modelo vetorial do eletrocardiograma. Para avaliar os resultados obtidos foram utilizados requisitos de desempenho declarados pelo FDA norte americano e pela norma européia IEC60601-2-51. Essas análises foram feitas através da utilização dos algoritmos gerados nas curvas provindas do banco de dados do PhisioNet. O método polinomial não foi considerado interessante na medida em que não possibilita gerar uma equação para um ciclo cardíaco, mas sim várias equações (uma para cada ponto do ciclo). Os demais métodos apresentaram melhor eficiência na medida em que foram capazes de gerar parâmetros com significado físico e possibilitando melhor caracterização de pontos importantes da curva do eletrocardiograma. / The electrocardiogram gives information related to the passage of an electric pulse through the heart and, therefore, to his state function. Since the beginning of electrocardiogram utilization, thanks to the work of Willem Einthoven building the first machine capable of measuring the electric pulse non-invasively and with sensitivity enough to be able to provide a profitable graph, it is widely used for clinical evaluation of patients. However the evolution of the machines that describes the electrocardiogram hadn´t much more advances since the elaborated by Einthoven in the beginning of the 20th century. They become smaller (even portable for some applications), the graphs are now displayed in video screens (instead of the paper strip) and, taking place as the biggest evolutions, machines that observes the electrocardiogram became able to recognize a cardiac cycle with high reliability and, more recently, became able to measure the ST parameter with liMITed precision (it needs the help of the operator to set specific measuring points in some cases). It is based in these facts that this dissertation looks for analyzing mathematic algorithms, more specifically the mathematic models of the electric impulse during the cardiac cycles, and evaluate their capacities to expound ECG parameters in a fast and reliable way in order to the physician receive promptly the data needed for his clinical evaluation of the patient. For the first step were analyzed some algorithms for electrocardiogram pulse detection (detection of R wave), in the following step were done the windowing of the ECG wave in order to separate the cardiac cycles. In this step were analyzed the mathematic models generated by polynomial equations, Fourier Transform and Wavelet Transform. And, in order to filter noises and generate leads not measure, it was implemented a kalman´s filter at a vector model. To evaluate the obtained results were used the requirements of performance given by north-american FDA and by the European rule IEC60601-2-51. These evaluations were done by executing the generated algorithms in the waves supplied by the databank PhisioNet. The polynomial method weren´t considered interesting because it weren´t able to generate an equation for the cardiac cycle, but many equations (one for each point of the cycle). The other methods showed a better efficiency since they were capable of generate parameters with physical meaning and being able to do a better characterization of the important points of the electrocardiogram wave.
2

Teoremas tauberianos para séries de Fourier

Gioveli, Izabel January 1999 (has links)
Neste trabalho, vamos caracterizar certas propriedades das séries de Fourier em função da velocidade de convergência a zero de seus coeficientes de Fourier. É fundamental em nossas hipóteses supor que a seqüência dos coeficientes an é monótona decrescente a zero. / In this work we characterize certain properties of Fourier series. It is of fundamental importance in our hypothesis to assume that an 1s a monotone sequence decreasing to zero.
3

Caracterização do sinal de emissão acústica proveniente da deformação axial em poço de visita de polietileno / Signal characteristics of acoustic emissions from the axial strain in polyethylene manhole

Gouveia Filho, Marcos Daniel 02 February 2015 (has links)
GOUVEIA FILHO, M. D. Caracterização do sinal de emissão acústica proveniente da deformação axial em poço de visita de polietileno. 2015. 119 f. Dissertação (Mestrado em Ciências de Materiais) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2015. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2015-06-19T11:26:39Z No. of bitstreams: 1 2015_dis_mdgouveiafilho.pdf: 5709600 bytes, checksum: 812b44a902a3961edaa2ce2098b2df33 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2015-06-23T17:57:35Z (GMT) No. of bitstreams: 1 2015_dis_mdgouveiafilho.pdf: 5709600 bytes, checksum: 812b44a902a3961edaa2ce2098b2df33 (MD5) / Made available in DSpace on 2015-06-23T17:57:35Z (GMT). No. of bitstreams: 1 2015_dis_mdgouveiafilho.pdf: 5709600 bytes, checksum: 812b44a902a3961edaa2ce2098b2df33 (MD5) Previous issue date: 2015-02-02 / he use of new materials in the sanitation industry aims to improve water treatment conditions and optimize the performance of the structures of sewage systems. Studies show that investments in sanitation are four times more effective than health. Manhole (PV) is an integral structure of the collection networks of major importance sewage because it is the sewage flow of the meeting from various facilities that are guided and follow for further processing. Non-destructive tests are widely used in modern industry worldwide to evaluate the quality and detection of changes in structure, small surface flaws, presence of cracks and other physical disruptions, being capable of detecting flaws in structures prematurely allowing constant monitoring and real time frame. The technique of acoustic emission (AE) is effective both during subsequent tests the implementation of the structure, guaranteeing their structural integrity, and in the real-time monitoring of the frame subject to the usual charging service, while performing its function without need of interrupting. To properly investigate the structure is necessary to know how the defects are and their respective acoustic activity. In this study, the acoustic emission signals generated in polyethylene manholes by variable axial deformation during loading are characterized both in time domain and in the frequency domain creating the signature of the defect / A utilização de novos materiais na indústria do saneamento, visa melhorar as condições do tratamento de água e otimizar o desempenho das estruturas de redes coletoras de esgoto. Estudos comprovam que os investimentos realizados em saneamento básico são quatro vezes mais efetivos que na saúde. Poço de visita (PV) é uma estrutura integrante das redes coletoras de esgotos de grande importância, pois nele ocorre o encontro do fluxo de esgotos provenientes de diversas instalações que são orientados e seguem para o posterior tratamento. Os ensaios não destrutivos são largamente utilizados na indústria moderna em todo o mundo para avaliação da qualidade e detecção de variações na estrutura, pequenas falhas superficiais, presença de trincas e outras interrupções físicas, sendo capaz de detectar prematuramente falhas em estruturas permitindo a monitoração constante da estrutura e em tempo real. A técnica de emissão acústica (EA) é eficaz tanto na fase de testes subsequentes à implementação da estrutura, garantindo sua integridade estrutural, quanto no monitoramento em tempo real d a estrutura sujeita a carregamento usual de serviço, enquanto desempenha sua função, sem necessidade de interrupção. Para investigar corretamente a estrutura é necessário conhecer como os defeitos se manifestam e sua respectiva atividade acústica. Neste trabalho, os sinais de emissão acústica gerados em poços de visita de polietileno por deformação axial durante carregamento variável são caracterizados tanto no domínio do tempo quanto no domínio da frequência criando a assinatura do defeito
4

Teoremas tauberianos para séries de Fourier

Gioveli, Izabel January 1999 (has links)
Neste trabalho, vamos caracterizar certas propriedades das séries de Fourier em função da velocidade de convergência a zero de seus coeficientes de Fourier. É fundamental em nossas hipóteses supor que a seqüência dos coeficientes an é monótona decrescente a zero. / In this work we characterize certain properties of Fourier series. It is of fundamental importance in our hypothesis to assume that an 1s a monotone sequence decreasing to zero.
5

Estudo do eletrocardiograma sob uma abordagem matemática. / Electrocardiogram evaluation under a mathematical approach.

Tito Coutinho Melco 10 November 2006 (has links)
O eletrocardiograma transMITe informações com relação à passagem do pulso elétrico pelo coração e, conseqüentemente, do funcionamento deste. Desde o início da sua utilização, possibilitada pelo trabalho de Willem Einthoven criando a primeira máquina capaz de medir o pulso elétrico de forma não invasiva e com sensibilidade forte o bastante para ser capaz de produzir um gráfico proveitoso, o eletrocardiograma é muito utilizado para avaliação clínica de pacientes. Entretanto a evolução das máquinas que o descrevem não foi muito além do que o elaborado por Einthoven no início do século 20. As máquinas capazes de captar o eletrocardiograma se tornaram menores (até portáteis para algumas aplicações), gráficos passaram a ser disponibilizados em telas de vídeo (ao invés das fitas de papel) e, como maior evolução, as máquinas que observam o eletrocardiograma passaram a conseguir captar a ocorrência de um ciclo cardíaco com alta confiabilidade e, atualmente, passaram a medir também o parâmetro ST com precisão deliMITada (necessitando ajuda do operador para ajuste em alguns casos). É baseado nestes fatos que esta dissertação procura estudar algoritmos matemáticos, de forma mais focada nos modelos do impulso elétrico durante os ciclos cardíacos, e avaliar suas capacidades de interpretar parâmetros do ciclo de ECG de forma precisa e rápida para que o médico tenha prontamente os dados necessários para realizar a avaliação clínica do paciente. Em primeira análise foram estudados os algoritmos para detecção do pulso de eletrocardiograma (detecção da onda R), em seguida feito o janelamento da curva de ECG a fim de separar os ciclos cardíacos. A partir deste ponto foram analisados os modelos matemáticos gerados por equações polinomiais, Transformada de Fourier e Transformada wavelet. E, com o intuito de filtrar ruídos e gerar derivações não medidas, foi implementado um filtro de kalman em um modelo vetorial do eletrocardiograma. Para avaliar os resultados obtidos foram utilizados requisitos de desempenho declarados pelo FDA norte americano e pela norma européia IEC60601-2-51. Essas análises foram feitas através da utilização dos algoritmos gerados nas curvas provindas do banco de dados do PhisioNet. O método polinomial não foi considerado interessante na medida em que não possibilita gerar uma equação para um ciclo cardíaco, mas sim várias equações (uma para cada ponto do ciclo). Os demais métodos apresentaram melhor eficiência na medida em que foram capazes de gerar parâmetros com significado físico e possibilitando melhor caracterização de pontos importantes da curva do eletrocardiograma. / The electrocardiogram gives information related to the passage of an electric pulse through the heart and, therefore, to his state function. Since the beginning of electrocardiogram utilization, thanks to the work of Willem Einthoven building the first machine capable of measuring the electric pulse non-invasively and with sensitivity enough to be able to provide a profitable graph, it is widely used for clinical evaluation of patients. However the evolution of the machines that describes the electrocardiogram hadn´t much more advances since the elaborated by Einthoven in the beginning of the 20th century. They become smaller (even portable for some applications), the graphs are now displayed in video screens (instead of the paper strip) and, taking place as the biggest evolutions, machines that observes the electrocardiogram became able to recognize a cardiac cycle with high reliability and, more recently, became able to measure the ST parameter with liMITed precision (it needs the help of the operator to set specific measuring points in some cases). It is based in these facts that this dissertation looks for analyzing mathematic algorithms, more specifically the mathematic models of the electric impulse during the cardiac cycles, and evaluate their capacities to expound ECG parameters in a fast and reliable way in order to the physician receive promptly the data needed for his clinical evaluation of the patient. For the first step were analyzed some algorithms for electrocardiogram pulse detection (detection of R wave), in the following step were done the windowing of the ECG wave in order to separate the cardiac cycles. In this step were analyzed the mathematic models generated by polynomial equations, Fourier Transform and Wavelet Transform. And, in order to filter noises and generate leads not measure, it was implemented a kalman´s filter at a vector model. To evaluate the obtained results were used the requirements of performance given by north-american FDA and by the European rule IEC60601-2-51. These evaluations were done by executing the generated algorithms in the waves supplied by the databank PhisioNet. The polynomial method weren´t considered interesting because it weren´t able to generate an equation for the cardiac cycle, but many equations (one for each point of the cycle). The other methods showed a better efficiency since they were capable of generate parameters with physical meaning and being able to do a better characterization of the important points of the electrocardiogram wave.
6

Teoremas tauberianos para séries de Fourier

Gioveli, Izabel January 1999 (has links)
Neste trabalho, vamos caracterizar certas propriedades das séries de Fourier em função da velocidade de convergência a zero de seus coeficientes de Fourier. É fundamental em nossas hipóteses supor que a seqüência dos coeficientes an é monótona decrescente a zero. / In this work we characterize certain properties of Fourier series. It is of fundamental importance in our hypothesis to assume that an 1s a monotone sequence decreasing to zero.
7

Análise das séries temporais de monitoramento de nível d'água em poços no aqüífero Rio Claro

Carnier Neto, Dagmar [UNESP] 25 August 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-08-25Bitstream added on 2014-06-13T20:27:11Z : No. of bitstreams: 1 carnierneto_d_me_rcla.pdf: 3759097 bytes, checksum: 779710eaadd918035376669c43711516 (MD5) / Esse trabalho apresenta os resultados obtidos com o monitoramento detalhado de nível d'água, realizado no período de 2002 a 2005 em poços no Aqüífero Rio Claro. Os problemas encontrados durante a coleta de dados dos poços de monitoramento foram solucionados por meio de programas desenvolvidos para este fim. Em seguida, os dados já tratados serviram à avaliação qualitativa dos fenômenos observados e comparados com aqueles encontrados na literatura. Por fim, foram aplicadas técnicas de análise de séries temporais (Análise de Fourier, Correlação Cruzada e Análise R/S) a esses dados, a fim de se verificar as periodicidades de alguns fenômenos naturais, como os ciclos sazonais e de maré terrestre, bem como estimar a relação temporal entre a pluviometria e a recarga, e avaliar o grau de persistência e auto-correlação das variações de nível d'água. Os resultados obtidos mostram que o monitoramento detalhado é capaz de fornecer informações que, além de contribuírem para um melhor conhecimento das características do aqüífero, podem auxiliar em processos de remediação, através da melhor caracterização da variação do nível d'água e seu conseqüente transporte vertical de contaminantes. / This work presents the results of detailed water level monitoring in the course of 2002 to 2005 in monitoring in wells on Rio Claro Aquifer. Problems found during data aquisition were solved by specific programs developed for this purpose. Qualitative evaluation of observed phenomena was made, comparing it with those from literature and, at the end, methods to time-series analysis were applied on data (Fourier Analysis, Cross-Correlation and R/S Analysis), in order to verify the periodicities of natural phenomena, like those resulting from seasonal cycles and earth-tides, to estimate temporal relationship between rainfall and well recovering, and evaluate the persistence and degree of auto-correlation of water levels variations. The results shows that detailed monitoring process gives important information that leads to a better knowledge on the aquifer characteristics, and it can help remediation process through a better characterization of water level variations and its consequent vertical transport of contaminants.
8

Estudo dos potenciais evocados miogênicos vestibulares de estado estável / Study of vestibular evoked myogenic potentials of steady state

Oliveira, Aline Cabral de January 2010 (has links)
A avaliação do potencial evocado miogênico vestibular é realizada por meio da captação de um potencial eletromiográfico, no domínio do tempo, decorrente da estimulação acústica da mácula sacular. Um método promissor, utilizado em outros tipos de potenciais evocados, possibilita a análise dos potenciais no domínio das frequências. A técnica de estado estável, como é conhecida, viabiliza a realização do exame com diferentes tipos de estímulos, simultaneamente, e a análise de cada uma das respostas em separado. O presente estudo teve como objetivo utilizar a técnica de estado estável para a obtenção de potenciais evocados miogênicos vestibulares, comparando a presença de respostas nos exames desses potenciais no domínio do tempo, com as obtidas nos exames, no domínio das frequências. Desse modo, captou-se o potencial evocado miogênico vestibular, no domínio do tempo, em 156 orelhas (78 adultos jovens com audição normal) nas frequências de 250, 500, 1000 e 2000 Hz e seguiu-se com a captação do potencial evocado miogênico de estado estável nessas mesmas frequências portadoras (escolhida uma frequência para cada indivíduo), moduladas em 20, 37, 40, 43, 70, 77 e 80 Hz. Na captação do exame no tempo, observou-se presença de onda em 150 dos 156 exames realizados (96,15%). As respostas encontradas, por frequência modulada, independente da portadora, registraram maiores presenças de picos e amplitudes médias para frequências menores que 43 Hz. A avaliação das respostas, por frequência portadora até 1.000 Hz, teve maior eficiência nas moduladoras de 37, 40 e 43 Hz, com odds ratio maior que 6,9. Para a portadora de 500 Hz, modulada a 20 Hz, entretanto, a resposta também esteve presente de maneira significativa e o valor do odds ratio igual a 11,5. Em 2.000 Hz, as respostas só foram observadas adequadamente em 37 e 40 Hz, porém com índices baixos de igualdade com as respostas do domínio do tempo (63,3 %). O potencial evocado miogênico vestibular de estado estável possui forte associação com o VEMP no domínio do tempo, sendo as respostas mais adequadas entre 37 e 43 Hz, independente da frequência portadora. _________________________________________________________________________________________ ABSTRACT: The evaluation of vestibular evoked myogenic potential is done by the collect of an eletromiogenic potential, within a certain time, originated from an acoustic stimulation of the saculus. A promising method, used in other kinds of evoked potential, allows an analysis of potentials according to the frequencies.The steady state technique, as we know, allows the execution of this test with different kinds of stimulus, simultaneously, and the analysis of each response separately. This present study aimed using the steady state technique to obtain the vestibular evoked myogenic potentials, comparing the presence of responses in these potentials tests within the time, with the ones obtained according to the frequencies. So, the vestibular evoked myogenic potentials were collected, within the time, in 156 ears (78 subjects) in the frequencies of 250, 500, 1000 and 2000 Hz and after that these potentials were collected in these same frequencies (chosen one frequency for each subject), but the frequencies were modulated in 20, 37, 40, 43, 70, 77 and 80 Hz. In the collection of the responses within the time, it was observed the presence of wave in 150 of the 156 ears tested (96,15%). The found responses, according to the modulated frequencies, independently of which one was, showed more presences of picks and medium amplitudes for frequencies under 43 Hz. In the collection of the responses within the time, it was observed the presence of wave in 150 of the 156 ears tested (96,15%). The found responses, according to the modulated frequencies, independently of which one was, showed more presences of picks and medium amplitudes for frequencies under 43 Hz. In 2000 Hz, the responses were just observed adequately in 37 and 40 Hz, however in low rates of equality with the responses according the time. (36,3%). The vestibular evoked myogenic potentials of steady state has a strong association with VEMP within the time, and more adequate responses are between 37 and 43 Hz, independently of the frequency.
9

Propriedades globais de uma classe de complexos diferenciais / Global properties of a class of differential complexes

Botós, Hugo Cattarucci 23 March 2018 (has links)
Considere a variedade Tn x S1 com coordenadas (t;x) e considere uma 1-forma diferencial fechada e real a(t) em Tn. Neste trabalho consideramos o operador Lpa = dt +a(t) Λ ∂x de D\'p em D\'p+1, onde D\'p é o espaço das p-correntes da forma u = ∑ Ι I Ι = puI (t, x)dtI. O operador acima define um complexo de cocadeia formado pelos espaços vetoriais D\'p e pelos homomorfismos lineares Lpa : D\'p → D\'p+1. Definiremos o que significa resolubilidade global no complexo acima e caracterizaremos para quais 1-formas a o complexo é globalmente resolúvel. Faremos o mesmo com respeito a hipoeliticidade global no primeiro nível do complexo. / Consider the manifold Tn x S1 with coordinates (t;x) and let a(t) be a real and closed differential 1-form on Tn. In this work we consider the operator Lpsub>a = dt +a(t) Λ ∂x de D\'p from D\'p to D\'p+1, where D\'p is the space of all p-currents u = ∑ Ι I Ι = puI (t, x)dtI . The above operator defines a cochain complex consisting of the vector spaces D\'p and of the linear maps Lpa : D\'p → D\'p+1. We define what global solvability means for the above complex and characterize for which 1-forms a the complex is globally solvable. We will do the same with respect to global hypoellipticity on the first level of the complex.
10

Simulação numérica de camadas de mistura compressíveis através de esquemas de alta precisão

Peçanha, Núbia Lúcia Guimarães January 2000 (has links)
Nesta dissertação, apresenta-se um estudo sobre esquemas numéricos de alta precisão para modelagem matemática de camadas de mistura compressíveis em desenvolvimento temporal. O objetivo central é analisar condições de transição em camadas de mistura para diferentes números de Reynolds e Mach. Ap resenta-se, em primeiro lugar, a motivação à utilização de esquemas numéricos de alta precisão que visem obter soluções de problemas de escoamentos que envolvem diversas escalas de tempo e espaço, os parâmetros físicos relevantes para o tipo de escoamento aqui analisado e algumas definições essenciais como camada de mistura e instabilidade de Kelvin-Helmholtz. Descrevem-se, na continuação, as equações que governam os escoamentos viscosos compressíveis, a adimensionalização correspondente dessas equações, o sistema de equações adimensionais e as condições iniciais e de contorno. A Teoria da instabilidade Linear Hidrodinârnica para escoamentos livres incompressíveis e compressíveis é revisada onde, em particular, mostra-se a importância da escolha da taxa de amplificação máxima no tocante aos efeitos de compressibilidade e de viscosidade e constata-se a instabilidade do perfil tangente hiperbólica. São descritos os esquemas de diferenças finitas implícitos compactos de alta que permitem obter melhores resultados que os de ordem inferior com menor custo computacional. São demonstradas aproximações para a primeira e segunda derivadas e formulações para a fronteira da primeira e segunda derivadas, cujos resultados são aproximados aos dos métodos espectrais com a vantagem de usar domínios e condições de fronteira mais gerais. Em seguida, faz-se wna análise dos erros dos esquemas numéricos. Por último, apresentam-se alguns dos resultados obtidos de simulações numéricas comparando-se com toda a teoria física estudada para diversos números de Mach e Reynolds. Em particular, analisa-se a evolução temporal dos vórtices coerentes para diferentes condições de compressibilidade e viscosidade. / In this work a study about high precision numerical schemes for the mathematical modeling of compressible temporal mixing layer is presented. The main objetive is to analise the transition conditions for the mi.xing layer with different Reynolds and Mach numbers. Firstly, the rnotivation of using high precision schemes to solve flows problems that involved different time and length scales is presented, along with the description of the main physical parameters and others definit ions such as mixing layers and Kelvin-Helrnholtz instability. T hen, the governing equations for compressible viscous flows, their adimensionalisation and the corresponding initial and boundary condit ions are established. The linear stability t heory is revised for both incompressible and compressible free shear flows. In parti-cular, it is showed the importance of t he choice of the maximum amplification rate for the compressibility and viscosity conditions adopted and it is verified the instability of the hyperbolic tangent profile. Then the high precision compact finite differences are presented along .vith approximation for the first and second derivatives for the central and boundary region of the computational domain. Finally, some results obtained from numerical simulations vlith differents Reynolds and Mach numbers are presented and the temporal evolution of coherent vortices is analysed.

Page generated in 0.0338 seconds