• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da gestão do uso e reúso de água em abatedouro de aves

Luiz Araújo da Silva, Jorge January 2007 (has links)
Made available in DSpace on 2014-06-12T18:05:08Z (GMT). No. of bitstreams: 2 arquivo8169_1.pdf: 3232041 bytes, checksum: b2b7b6f4f6950f3aad43b7c5e9717601 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2007 / O setor avícola de Pernambuco é de relevância sócio-econômica, em especial as atividades ligadas à produção e industrialização do frango de corte. Neste contexto a sustentabilidade ambiental da cadeia produtiva é imprescindível. O objetivo deste trabalho foi identificar os impactos ambientais gerados pelos efluentes e recomendar soluções para otimização da água e seu reúso, mediante um modelo microeconômico de controle aplicado no abatedouro avícola da Agropecuária Serrote Redondo no município de Afogados da Ingazeira, semi-árido de Pernambuco. Para isso foi realizada uma análise do processo de abate e, posteriormente a identificação da demanda de água e a geração de efluentes. Foram estabelecidas quais as áreas com maior potencial para aplicação de alternativas para o uso racional e reúso da água. O consumo médio de água por ave abatida foi de 23,76 litros dos quais 72,3 % estão diretamente ligados ao abate. O efluente gerado apresentou DQO e DBO de 4325 e 3346 mg/L, respectivamente. Para as lagoas de estabilização, as eficiências calculadas para a DQO, DBO e remoção de óleos e graxas foram de 92,0 %, 94,6 % e 94,4 %, respectivamente. Com base nos resultados obtidos foram identificadas ações pontuais para a melhoria dos processos de tratamento dos efluentes. Mediante o uso da hidrometração foi possível identificar os principais pontos de consumo de água no abatedouro e propor medidas de gestão de água. Os levantamentos obtidos por meio do desenvolvimento deste trabalho permitem concluir que o uso racional e reúso da água são ferramentas básicas para os programas de gestão de águas e efluentes em abatedouros de aves, mas que as mesmas devem ser criteriosamente analisadas, pois podem apresentar restrições de ordem técnica ou econômica
2

Avaliação da biodegradação anaeróbia de efluente de abatedouro de aves

Patrice Alexandre Lima, Danielle 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T17:37:41Z (GMT). No. of bitstreams: 2 arquivo2406_1.pdf: 2039924 bytes, checksum: b52fd4471609abf41c601c09dec158a3 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente trabalho buscou avaliar a aplicabilidade da tecnologia anaeróbia para tratamento de efluente de abatedouro de aves, onde foi testado de forma comparativa, o uso da água residuária bruta, pré-tratada por sistema de flotação por ar dissolvido (FAD) e pré-tratada com hidrólise alcalina. Na primeira etapa do trabalho foi realizada a caracterização da água residuária do abatedouro de aves. O sistema de tratamento adotado pela empresa é composto de um FAD seguido de três lagoas sendo a 1ª anaeróbia e a 2ª e 3ª facultativas. Esse sistema apresentou, durante a caracterização, eficiência de remoção de DQO bruta, DBO bruta e óleos e graxas de 92%, 99% e 98%, respectivamente. Em escala de laboratório foram operados simultaneamente três reatores anaeróbios (R1, R2 e R3). Em R1 foi utilizado água residuária bruta, em R2 água residuária pré-tratada pelo sistema FAD da empresa e em R3 água residuária bruta pré-tratada por hidrólise alcalina com NaOH 0,1% (m/v) no laboratório. Os reatores sofreram choque de carga orgânica no 19º dia de operação, por este motivo apresentaram diferentes condições antes e depois do choque de carga. A eficiência média de remoção de DQO em R1, R2 e R3 foram 71±4%, 68±4% e 75±4%, respectivamente. No entanto, apesar do fato de que possuíam eficiências de remoção aproximadas o reator R1 apresentou colmatação de gordura na parte superior e obstrução progressiva do leito reacional tendo sua operação finalizada por este fim. Em R2 foi observado lavagem de biomassa o que pode ter acarretado na eficiência média de 68%. Em R3 foi observado maior estabilidade em relação ao choque de carga, com manutenção de DQO efluente filtrada praticamente estável. Contudo R3 também apresentou flotação do lodo e colmatação de gordura, tendo sua alimentação impossibilitada, a operação também foi finalizada. Após o choque de carga foi verificado o acúmulo de ácidos orgânicos voláteis nos três reatores. O reator R1 não mostrou estabilidade em reverter esta situação. Em R2 apesar do acúmulo o sistema mostrou que talvez a acumulação de ácidos pudesse ser revertida, necessitando possivelmente de período operacional mais longo. O reator R3 apresentou, apesar do acúmulo, remoção de ácidos principalmente o ácido acético e o ácido propiônico garantido maior estabilidade ao reator. Sendo assim o reator R3 demonstrou bom desempenho na remoção de matéria orgânica e ácidos orgânicos voláteis, tendo maior estabilidade durante o choque de carga orgânica. Entretanto, um período mais longo seria necessário para avaliar estratégias a fim de impedir a flotação do lodo e colmatação de gordura no reator
3

Avaliação qualitativa da água residuária de abatedouro de aves para fins de reúso em irrigação

Minghini, Israel [UNESP] 20 November 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-11-20Bitstream added on 2014-06-13T19:14:05Z : No. of bitstreams: 1 minghini_i_me_botfca.pdf: 448467 bytes, checksum: b2a4f494cb357e662adbf52c2039ccbb (MD5) / O objetivo do presente trabalho consistiu na avaliação de parâmetros de qualidade da água residuária proveniente de abatedouro de aves, visando analisar a possibilidade de reutilizá-la na irrigação de culturas agrícolas, após sua caracterização. As águas residuárias do abatedouro de aves, localizado na cidade de Pereiras – SP, foram coletadas em diferentes dias e épocas do ano e analisadas quanto aos seguintes parâmetros: pH, temperatura, condutividade elétrica, fósforo total, nitrato, nitrito, sólidos sedimentáveis, ferro, alumínio, turbidez, Salmonellas sp, macro e micronutrientes. As temperaturas do ar e da água foram medidas no momento da coleta.A discussão dos resultados obtidos esteve de acordo com a Resolução do Conselho Nacional do Meio Ambiente (CONAMA) nº 357, de 17 de março de 2005, que estabelece os padrões para classificação dos corpos de água. A condutividade elétrica foi avaliada segundo padrões propostos pela Companhia de Tecnologia de Saneamento Básico (CETESB, 2005) e o alumínio, segundo valor estabelecido pelo Ministério da Saúde – Portaria nº 1 469. Os resultados obtidos permitem concluir que a água residuária analisada, não deve ser descartada diretamente em corpos hídricos naturais, porém, pode ser utilizada na irrigação de culturas agrícolas, após simples desinfecção. / The aim of this search consisted in comparing the quality of wastewater from a poultry slaughterhouse, trying to analyze the possibility of using it in the irrigation of agricultural growing, after its make-up. Samples were colleted from wastewater from a poultry slaughterhouse in Pereiras – SP, in different days or time of the year, analyzing the following: pH, temperature, electrical conductivity, total phosphorus, nitrate, nitrite, sedimentary solids, iron, aluminium, muddy, salmonella, macro and micro nutrients. The temperature of the air and of the water were measured at collection time.The results were evaluated according to the Resolution of the Environment National Council (CONAMA) nº 357, on March 17th- 2005, which establish the patterns to classify the water contents. The electrical conductivity was evaluated according to the amount suggested by CETESB/2005 and the aluminium according to the established amount by Health Ministry – Regulation nº 1.469. The obtained results allow to conclude that the analyzed wastewater, must not be rejected in natural water contents, however, it can be used in the irrigation of agricultural growing, after simple disinfection.
4

Disseminação de bactérias dos gêneros Campylobacter e Salmonella em linhas de abate de aves

Cortez, Ana Lígia Lordello [UNESP] 04 May 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-05-04Bitstream added on 2014-06-13T19:43:39Z : No. of bitstreams: 1 cortez_all_dr_jabo.pdf: 430590 bytes, checksum: 666a520b7c02417cfef371371e073100 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Os objetivos do presente trabalho foram verificar a ocorrência de Campylobacter jejuní, Campylobacter calí, Salmonella spp., Salmonella Enteritidis e Salmonella Typhimurium em abatedouros de aves e avaliar a resistência das amostras de Salmonella spp. isoladas frente a antimicrobianos de uso comum. Foram colhidas amostras de fezes; penas; água de escaldamento, evisceração e resfriamento; e amostras de carcaça não eviscerada, eviscerada e resfriada em seis abatedouros de aves. Campylobacter jejuni foi detectada em 14 amostras (5%), a maior porcentagem foi em amostras de fezes oito amostras (22%), e C. calí em foi isolada em uma amostra de pena (0,35%). Salmonella spp. foi detectada em 18% (52/288) dos isolados, enquanto os sorotipos S. Enteritidis em 5,6% (16/288) e S. Typhimurium em 2,4% (7/288). Os testes de resistência aos antimicrobianos apontaram 25 amostras resistentes ao aztreonam e à ampicilina (86,2%), 21 à tetraciclina (72,4%) e 16 à amoxicilina/ácido clavulânico e sulfazotrim (55,2%). Nenhum dos isolados testados apresentou 100% de resistência ou sensibilidade aos antimicrobianos utilizados. Os resultados indicam que há uma necessidade de melhorar a qualidade higiênico-sanitária em linhas de abate de aves e o cuidado com o uso indiscriminado de antibióticos na avicultura, oferecendo aos consumidores produtos livres de agentes zoonóticos. / The present study was carried out to report the occurrence of Campylobacter jejuní, Campylobacter calí, Salmonella spp., Salmonella Enteritidis e Salmonella Typhimurium in chicken abattoirs and to evaluate the resistance of Salmonella spp. isolated to antibiotics of common use. Samples of feces; feathers; scald, evisceration, and chiller water; and non-eviscerated, eviscerated, and chilted carcasses were coUeded from six chicken abattoirs. Campylobacter jejuni was isolated in 14 samples (5%), isolation was greater in feces, eight samples (22%), one feather sample was positive for the species C. calí (0.35%). Salmonella spp. was detected in 18% (52/288) of the isolates, whereas serotypes S. Enteritidis were identified in 5.6% (16/288) and S. Typhimurium and 2.4% (7/288). Antibiotic tests indicate 25 resistant samples to aztreonam and to ampicilin (86.2%), 21 to tetracycline (72.4%) and 16 to amoxicilin/clavulanic acid and to sulfazotrim (55.2%). None sample tested were 100% resistant or sensitive to ali the antibiotics tested. The results exhibit the need to improve hygiene and sanitary standards in poultry sfaughter fines, and care with the indiscriminate use of antibiotics in avicultura, offering to the consumers products free of zoonotic agents.
5

Avaliação de desempenho de reator anaeróbio-aeróbio com recirculação da fase líquida no tratamento de água residuária proveniente de abatedouro de aves / Performance evaluation of an anaerobic-aerobic reactor with recycle of the liquid phase for treatment of poultry slaughterhouse wastewater

Pontes, Ana Flávia Vieira 27 April 2009 (has links)
Este trabalho buscou avaliar o desempenho de um reator de leito fixo e escoamento ascendente, operado de modo contínuo, com argila expandida e espuma de poliuretano como suportes para imobilização da biomassa, no tratamento de água residuária proveniente de abatedouro de aves. Na primeira fase do trabalho, o reator foi operado em condição anaeróbia e anaeróbia-aeróbia, no tratamento da água residuária bruta proveniente do abatedouro. No entanto, sua eficiência na redução de matéria orgânica pode ser atribuída a processos de adsorção e não biodegradação, o que resultou em períodos de operação curtos devido à obstrução do leito reacional. Na segunda fase, o reator foi alimentado com água residuária coletada após o pré-tratamento por sistema de flotação por ar dissolvido (FAD), realizado no próprio abatedouro, com intuito de minimizar a carga lipídica e a concentração de sólidos na entrada do reator. Assim, a vida útil do reator foi prolongada, com eficiências médias de remoção de DQO e nitrogênio total de 90 \'+ OU -\' 4% e 44 \'+ OU -\' 10%, respectivamente, e eficiência de desnitrificação de 89 \'+ OU -\' 6%, para o reator anaeróbio-aeróbio com razão de recirculação do efluente líquido igual a 1,5. Assim, o reator demonstrou bom desempenho na remoção simultânea de matéria orgânica e nutrientes, desde que seja precedido por sistema de pré-tratamento para remoção parcial de sólidos e óleos e graxas. / This work aimed to evaluate the performance of an up-flow fixed bed reactor, operated in a continuous way, using expanded clay and polyurethane foam as supports for immobilization of the biomass, for treatment of poultry slaughterhouse wastewater. Initially, the reactor was operated under anaerobic and anaerobic-aerobic conditions for the treatment of poultry slaughterhouse wastewater. However, the COD removal efficiency was related to adsorption and not to biodegradation processes. In this way, the operational periods were short due to solids retention in the system. In the second part of this work, trying to reduce the lipids and solids concentration in the reactor\'s affluent, the wastewater was collected after a pre-treatment installed at the poultry slaughterhouse. This pre-treatment was constituted of a dissolved air flotation (DAF) system. As a result, the operational longevity of the reactor was increased and the COD and total nitrogen removal efficiencies were 90 \'+ OU -\' 4% and 44 \'+ OU -\' 10% respectively, and the denitrification efficiency was 89 \'+ OU -\' 6% under an anaerobic-aerobic condition with a recycle ratio of the liquid phase of 1,5. Therefore, the reactor showed a good performance in reducing the organic matter and removing nutrients simultaneously, since it is preceded by a pre-treatment for the partial removal of solids, oils and grease.
6

Fatores físico-químico e bacteriológicos do sistema de lavagem e pré-resfriamento de carcaças de frango e sua relação com a pesquisa de Salmonella spp. em carcaças pré-resfriadas

Andrade, Paulo Henrique Marques de [UNESP] 02 December 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-12-02Bitstream added on 2014-06-13T19:09:24Z : No. of bitstreams: 1 andrade_phm_me_arafcf.pdf: 233794 bytes, checksum: 4fb09f68aeeb569be13ec267ab33fc6f (MD5) / Universidade Estadual Paulista (UNESP) / O objetivo do trabalho foi a análise bacteriológica e físico-química de amostras da água do Sistema de Pré-resfriamento de um abatedouro de aves e na análise bacteriológica de carcaças de frango antes, no interior e após o Sistema de Pré-resfriamento. As variáveis físico-químicas da água foram relacionadas com presença ou ausência de Salmonella spp. nas carcaças após sistema de pré-resfriamento. Em relação à contagem bacteriana, observamos que a saída do pré-chiller é o ponto de coleta onde há maior contaminação da água. No entanto, há uma queda significativa na contaminação da água na saída do chiller. Na análise por agrupamento hierárquico adotando a variável Salmonella spp. como classe, não foi possível verificar tendência de separação entre as amostras contaminadas e as não contaminadas, porém, pode-se perceber que com o aumento da velocidade de abate a separação entre as amostras passa a existir. Ao analisar as componentes principais, considerando todas as variáveis, observamos que existe uma relação entre a contaminação por Salmonella spp. e a vazão da renovação da água do pré-chiller. Assim, foi possível verificar que o controle dos parâmetros físico-químicos e microbiológicos da água do sistema de pré-resfriamento, bem como as diversas variáveis das condições de abate, são fundamentais para garantirem carcaças pré-resfriadas livres de Salmonella spp. Torna-se necessário propor estudos específicos de cada variável a fim de que as condições ideais de abate sejam estabelecidas e o processo seja autocontrolado / This study was based on microbiological and physicochemical analysis of water samples from the pre-cooling system of a poultry slaughterhouse and the bacteriological analysis of chicken carcasses before, during and after the pre-cooling system. The physicochemical variables of the water were related to the presence or absence of Salmonella spp. in the carcasses after the pre-cooling system. Regarding the amount of bacteria, it was observed that the output of the pre-chiller is the collecting point where the water is most contaminated. However, there is a significant decrease of contamination in the water leaving the chiller. In the hierarchical cluster analysis taking the variable Salmonella spp. as a class it was not possible to verify the trend of separation between the contaminated samples and the non-contaminated ones, although it was realized that with the increase in speed of slaughter the separation between samples exists. By analyzing the main components, considering all variables, it was observed that there is a relation between the contamination by Salmonella spp. and the flow rate of the water renewal in the pre-chiller. Therefore, it was verified that the control of physicochemical and microbiological parameters of the water in the pre-cooling system and the variables of slaughtering conditions are essential to guarantee pre-cooled carcasses free from Salmonella spp. This it becomes necessary to propose specific studies of each variable so that the ideal conditions for slaughter are established and the process can become self-controlled
7

Avaliação de desempenho de reator anaeróbio-aeróbio com recirculação da fase líquida no tratamento de água residuária proveniente de abatedouro de aves / Performance evaluation of an anaerobic-aerobic reactor with recycle of the liquid phase for treatment of poultry slaughterhouse wastewater

Ana Flávia Vieira Pontes 27 April 2009 (has links)
Este trabalho buscou avaliar o desempenho de um reator de leito fixo e escoamento ascendente, operado de modo contínuo, com argila expandida e espuma de poliuretano como suportes para imobilização da biomassa, no tratamento de água residuária proveniente de abatedouro de aves. Na primeira fase do trabalho, o reator foi operado em condição anaeróbia e anaeróbia-aeróbia, no tratamento da água residuária bruta proveniente do abatedouro. No entanto, sua eficiência na redução de matéria orgânica pode ser atribuída a processos de adsorção e não biodegradação, o que resultou em períodos de operação curtos devido à obstrução do leito reacional. Na segunda fase, o reator foi alimentado com água residuária coletada após o pré-tratamento por sistema de flotação por ar dissolvido (FAD), realizado no próprio abatedouro, com intuito de minimizar a carga lipídica e a concentração de sólidos na entrada do reator. Assim, a vida útil do reator foi prolongada, com eficiências médias de remoção de DQO e nitrogênio total de 90 \'+ OU -\' 4% e 44 \'+ OU -\' 10%, respectivamente, e eficiência de desnitrificação de 89 \'+ OU -\' 6%, para o reator anaeróbio-aeróbio com razão de recirculação do efluente líquido igual a 1,5. Assim, o reator demonstrou bom desempenho na remoção simultânea de matéria orgânica e nutrientes, desde que seja precedido por sistema de pré-tratamento para remoção parcial de sólidos e óleos e graxas. / This work aimed to evaluate the performance of an up-flow fixed bed reactor, operated in a continuous way, using expanded clay and polyurethane foam as supports for immobilization of the biomass, for treatment of poultry slaughterhouse wastewater. Initially, the reactor was operated under anaerobic and anaerobic-aerobic conditions for the treatment of poultry slaughterhouse wastewater. However, the COD removal efficiency was related to adsorption and not to biodegradation processes. In this way, the operational periods were short due to solids retention in the system. In the second part of this work, trying to reduce the lipids and solids concentration in the reactor\'s affluent, the wastewater was collected after a pre-treatment installed at the poultry slaughterhouse. This pre-treatment was constituted of a dissolved air flotation (DAF) system. As a result, the operational longevity of the reactor was increased and the COD and total nitrogen removal efficiencies were 90 \'+ OU -\' 4% and 44 \'+ OU -\' 10% respectively, and the denitrification efficiency was 89 \'+ OU -\' 6% under an anaerobic-aerobic condition with a recycle ratio of the liquid phase of 1,5. Therefore, the reactor showed a good performance in reducing the organic matter and removing nutrients simultaneously, since it is preceded by a pre-treatment for the partial removal of solids, oils and grease.

Page generated in 0.0879 seconds