• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Absorção da radiação por aerossóis na Amazônia / Light Absorption by Aerosol Particle in Amazonia

Holanda, Bruna Amorim 03 December 2015 (has links)
Neste estudo foi feita uma detalhada caracterização das propriedades óticas de partículas de aerossóis biogênicos, de poluição urbana e de queimadas na bacia Amazônia. Foram utilizadas diferentes abordagens, incluindo medidas in-situ e por sensoriamento remoto em várias localidades. Radiômetros solares da rede AERONET e instrumentos de medida de absorção (Aetalômetros e MAAP) e espalhamento (Nefelômetros) foram utilizados no experimento GoAmazon2014/5 que estudou o efeito das emissões urbanas de Manaus nas propriedades de aerossóis. Em regiões impactadas pela queima de biomassa, a forçante radiativa foi quantificada através de medidas da AERONET, separando as contribuições de carbono orgânico (OC) e elementar (EC). Com base apenas nas propriedades óticas dos aerossóis, foi feita uma análise qualitativa dos tipos de aerossóis dominantes durante a queima de biomassa na Amazônia, avaliando seus impactos no balanço radiativo. O OC emitido nas queimadas tem forte efeito de resfriamento no topo da atmosfera, com uma forçante radiativa de -53 ± 17 W/m². O EC é altamente absorvedor e, apesar de estar presente em menor quantidade que o OC, apresenta um forte efeito na forçante radiativa no topo da atmosfera, tornando-a significativamente menos negativa, com efeitos de até -12 ± 9 W/m². As propriedades de absorção e espalhamento associadas com as emissões urbanas da cidade de Manaus foram analisadas. Uma significativa diferença na componente de absorção da profundidade ótica foi observada entre dois sítios localizados vento acima e vento abaixo da pluma urbana. O efeito da absorção é notável principalmente na estação chuvosa, mas também pode ser observado com as plumas de queimadas na estação seca. A partir de medidas in-situ, foi observado que o albedo de espalhamento simples (SSA) médio diminui de 0,92 ± 0,06 antes de Manaus para 0,83 ± 0,11 na região impactada pela pluma urbana durante a estação chuvosa. Medidas in-situ do coeficiente de absorção do particulado PM10 foram realizadas em paralelo com o PM2.5 durante a estação chuvosa na reserva ZF2 para análise da absorção de partículas grossas biogênicas. Em condições de dominância do particulado biogênico, a absorção em 880 nm do PM10 é cerca de 10% superior à absorção do PM2.5 no mesmo comprimento de onda, inferindo a absorção da radiação por partículas biogênicas na moda grossa. / In this study, a detailed characterization of aerosol optical properties for the biological, urban pollution and biomass burning aerosols was performed in the Amazon basin. A number of different approaches were used, including in-situ and remote sensing measurements in several locations. As part of the GoAmazon2014/5 experiment, solar radiometers from AERONET Network and in-situ instruments measuring absorption (Aethalometers and MAAP) and scattering coefficients (Nephelometers) were used to assess the effect of Manaus urban emissions on the aerosol properties. In regions heavily affected by the biomass burning events, the radiative forcing retrieved by AERONET was quantified, separating the contributions of organic carbon (OC) and elemental (EC). Based exclusively on the aerosol optical properties, a qualitative analysis of the dominant aerosol types was performed in the Amazon, assessing its impact on the radiative balance. The OC emitted from biomass burn has strong cooling effect at the top of the atmosphere, presenting an instantaneous radiative forcing of -53 ± 17 W/m². The EC is highly absorbing and, despite its lower concentration compared to the OC, showed a strong effect on the instantaneous radiative forcing at the top of the atmosphere, making it significantly less negative, with an effect up to -12 ± 9 W/m². The absorption and scattering properties associated with the urban emissions from the Manaus city were analyzed. A significant difference on the absorption optical depth was observed between two sites located upwind and downwind of the urban plume, respectively. The effect of absorption is particularly remarkable in the rainy season, but can also be observed with the biomass burning plumes during the dry season. In-situ measurements showed that the averaged single scattering albedo (SSA) decreased from 0.92 ± 0.06 upwind to 0.83 ± 0.11 downwind of Manaus urban plume during the wet season. In-situ measurements of the spectral absorption coefficient of PM10 cut size were performed in parallel with the PM2.5 during the wet season at ZF2 reserve in order to study the light absorption by biological coarse particles. In atmospheric conditions with the dominance of biological particles, the PM10 absorption at 880 nm is up to 10 % higher than the PM2.5 absorption at the same wavelength, inferring the absorption of radiation by coarse mode biological particles.
2

Absorção da radiação por aerossóis na Amazônia / Light Absorption by Aerosol Particle in Amazonia

Bruna Amorim Holanda 03 December 2015 (has links)
Neste estudo foi feita uma detalhada caracterização das propriedades óticas de partículas de aerossóis biogênicos, de poluição urbana e de queimadas na bacia Amazônia. Foram utilizadas diferentes abordagens, incluindo medidas in-situ e por sensoriamento remoto em várias localidades. Radiômetros solares da rede AERONET e instrumentos de medida de absorção (Aetalômetros e MAAP) e espalhamento (Nefelômetros) foram utilizados no experimento GoAmazon2014/5 que estudou o efeito das emissões urbanas de Manaus nas propriedades de aerossóis. Em regiões impactadas pela queima de biomassa, a forçante radiativa foi quantificada através de medidas da AERONET, separando as contribuições de carbono orgânico (OC) e elementar (EC). Com base apenas nas propriedades óticas dos aerossóis, foi feita uma análise qualitativa dos tipos de aerossóis dominantes durante a queima de biomassa na Amazônia, avaliando seus impactos no balanço radiativo. O OC emitido nas queimadas tem forte efeito de resfriamento no topo da atmosfera, com uma forçante radiativa de -53 ± 17 W/m². O EC é altamente absorvedor e, apesar de estar presente em menor quantidade que o OC, apresenta um forte efeito na forçante radiativa no topo da atmosfera, tornando-a significativamente menos negativa, com efeitos de até -12 ± 9 W/m². As propriedades de absorção e espalhamento associadas com as emissões urbanas da cidade de Manaus foram analisadas. Uma significativa diferença na componente de absorção da profundidade ótica foi observada entre dois sítios localizados vento acima e vento abaixo da pluma urbana. O efeito da absorção é notável principalmente na estação chuvosa, mas também pode ser observado com as plumas de queimadas na estação seca. A partir de medidas in-situ, foi observado que o albedo de espalhamento simples (SSA) médio diminui de 0,92 ± 0,06 antes de Manaus para 0,83 ± 0,11 na região impactada pela pluma urbana durante a estação chuvosa. Medidas in-situ do coeficiente de absorção do particulado PM10 foram realizadas em paralelo com o PM2.5 durante a estação chuvosa na reserva ZF2 para análise da absorção de partículas grossas biogênicas. Em condições de dominância do particulado biogênico, a absorção em 880 nm do PM10 é cerca de 10% superior à absorção do PM2.5 no mesmo comprimento de onda, inferindo a absorção da radiação por partículas biogênicas na moda grossa. / In this study, a detailed characterization of aerosol optical properties for the biological, urban pollution and biomass burning aerosols was performed in the Amazon basin. A number of different approaches were used, including in-situ and remote sensing measurements in several locations. As part of the GoAmazon2014/5 experiment, solar radiometers from AERONET Network and in-situ instruments measuring absorption (Aethalometers and MAAP) and scattering coefficients (Nephelometers) were used to assess the effect of Manaus urban emissions on the aerosol properties. In regions heavily affected by the biomass burning events, the radiative forcing retrieved by AERONET was quantified, separating the contributions of organic carbon (OC) and elemental (EC). Based exclusively on the aerosol optical properties, a qualitative analysis of the dominant aerosol types was performed in the Amazon, assessing its impact on the radiative balance. The OC emitted from biomass burn has strong cooling effect at the top of the atmosphere, presenting an instantaneous radiative forcing of -53 ± 17 W/m². The EC is highly absorbing and, despite its lower concentration compared to the OC, showed a strong effect on the instantaneous radiative forcing at the top of the atmosphere, making it significantly less negative, with an effect up to -12 ± 9 W/m². The absorption and scattering properties associated with the urban emissions from the Manaus city were analyzed. A significant difference on the absorption optical depth was observed between two sites located upwind and downwind of the urban plume, respectively. The effect of absorption is particularly remarkable in the rainy season, but can also be observed with the biomass burning plumes during the dry season. In-situ measurements showed that the averaged single scattering albedo (SSA) decreased from 0.92 ± 0.06 upwind to 0.83 ± 0.11 downwind of Manaus urban plume during the wet season. In-situ measurements of the spectral absorption coefficient of PM10 cut size were performed in parallel with the PM2.5 during the wet season at ZF2 reserve in order to study the light absorption by biological coarse particles. In atmospheric conditions with the dominance of biological particles, the PM10 absorption at 880 nm is up to 10 % higher than the PM2.5 absorption at the same wavelength, inferring the absorption of radiation by coarse mode biological particles.
3

Avaliação da dose de radiação absorvida e sua importância na definição dos protocolos dos exames de tomografia computadorizada / Evaluation of absorbed radiation dose and its importance for the definition of computerized tomography exam protocols

Altemani, João Mauricio Carrasco, 1950- 28 August 2018 (has links)
Orientador: Fernando Cendes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-28T02:24:31Z (GMT). No. of bitstreams: 1 Altemani_JoaoMauricioCarrasco_D.pdf: 1901312 bytes, checksum: bcace160b968ce113f8f422a3db9339b (MD5) Previous issue date: 2015 / Resumo: Esse trabalho foi realizado para avaliar as doses de radiação absorvidas em exames de tomografia computadorizada em um hospital geral que atende uma grande população no Brasil. O FDA (Food and Drug Administration) considera que exames de CT com a absorção de uma dose efetiva de 10 mSv podem ser associados com um aumento na probabilidade de desenvolver um câncer fatal na proporção de 1/2000. Foram revisados 1352 relatórios de exames de tomografia computadorizada, provenientes de dois aparelhos, um com 16 e outro com 64 detectores. No aparelho de 16 detectores doses absorvidas ? 10 mSv foram observadas em 182 casos de um total de 326 pacientes (56%), enquanto no aparelho de 64 detectores essas doses foram observadas em 517 casos de um total de 996 pacientes (52%). Doses absorvidas > 100 mSv foram observadas em 16% de todos pacientes. Em ambos aparelhos , exames de abdome e de tórax + abdome apresentaram doses significantemente maiores que nos exames de pescoço, cabeça e tórax. Exames de abdome e tórax + abdome realizados com espessura de 1,25 mm no tomógrafo de 16 detectores e com 1,0 mm no aparelho de 64 detectores mostraram uma significante redução da dose absorvida em comparação com os mesmos tipos de exame realizados com espessura de 0,5 mm no aparelho de 64 detectores. Os exames de tórax realizados com espessura de 1,25 mm no tomógrafo de 16 detectores também mostraram uma significante diminuição da dose absorvida em comparação ao mesmo tipo de exame realizado no aparelho de 64 detectores com cortes de 0,5 mm. O aumento da espessura dos cortes tomográficos não causou uma significativa alteração na qualidade das imagens. Em conclusão, exames de tomografia computadorizada são frequentemente associados com altas doses de radiação absorvida indicando que os protocolos de exames devem ser reavaliados. Para exames de tomografia de abdome e de tórax + abdome , o aumento da espessura dos cortes pode proteger os pacientes de altas doses de radiação desnecessárias / Abstract: This study was conducted to evaluate the absorbed radiation doses in CT examinations in a general hospital that serves a large population in Brazil. The Food and Drug Administration (FDA) considers that CT examination with an effective dose of 10 mSv may be associated with an increase in the possibility of fatal cancer of around 1/2000. CT examinations of 1352 patients performed in two types of CT equipment (with 16 and 64 detectors) were reviewed. In the 16 detector CT scanner, an absorbed dose ?10 mSv was detected in 182 out of 326 patients (56%) whereas in the 64 detector CT scanner, in 517 out of 996 (52%). Absorbed dose > 100 mSv was seen in 16% of all patients. In both CT scanners, examinations of abdomen and thorax+ abdomen presented an absorbed dose significantly higher than neck, head and thorax. Examinations of abdomen and thorax+ abdomen performed with slices of 1,25 mm in the 16 detector CT scanner and with 1,0 mm in the 64 detector CT scanner showed a significant reduction of the absorbed dose in comparison to the same type of examination with slices of 0.5 mm in the 64 detector CT scanner. The examinations of thorax performed with slices of 1,25 mm in the 16 detector scanner also showed a significant reduction of the absorbed dose in comparison to the examinations performed with slices of 0,5 mm in the 64 detectors scanner. The increase of the slice thickness did not lead to noticeable alteration of the image quality. In conclusion, CT examinations were often associated with high doses of absorbed radiation indicating that the protocols of the examinations should be reevaluated. For CT examinations of abdomen and thorax+abdomen, the increase of the slice thickness can protect patients from unnecessarily high doses of radiation / Doutorado / Fisiopatologia Médica / Doutor em Ciências
4

Síntese e avaliação de novos candidatos a fotoprotetores absorvedores de radiações UVA e UVB, desenhados a partir de compostos análogos a produtos naturais / Synthesis and evaluation of novel candidates for UVA and UVB absorber photoprotectors, drawn from compounds analogous to natural products

Luzin, Rangel Magalhães 29 August 2018 (has links)
Submitted by Liliane Ferreira (ljuvencia30@gmail.com) on 2018-09-19T14:46:51Z No. of bitstreams: 2 Tese - Rangel Magalhães Luzin - 2018.pdf: 3753425 bytes, checksum: 3ac739156d95f6ef2de370e5c5ce093c (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-09-20T11:32:29Z (GMT) No. of bitstreams: 2 Tese - Rangel Magalhães Luzin - 2018.pdf: 3753425 bytes, checksum: 3ac739156d95f6ef2de370e5c5ce093c (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-09-20T11:32:29Z (GMT). No. of bitstreams: 2 Tese - Rangel Magalhães Luzin - 2018.pdf: 3753425 bytes, checksum: 3ac739156d95f6ef2de370e5c5ce093c (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-08-29 / It is known that sun exposure is one of the factors that contribute greatly to the appearance of skin cancer. Cancer cases have arisen annually on the planet and many of these cases have direct correlation with sun exposure. Knowing that both UVA and UVB radiation are harmful to health when the person is overexposed, the need arises for the use of devices to protect the skin and one of these ways and already recognized by the scientific community is through the prophylactic use of protectors solar power. Thus, this work proposes the synthesis, structural characterization, thermal stability verification, molar absorptivity calculation and in vitro UVB protection factor (PFUVB) calculated by the spectrophotometric method described by Mansur of new compounds derived from structures analogous to natural products. The structural planning was based on triazine derivatives (they are already commercially used with relative efficiency) and the use of chalcones, which are structures that besides having double bonds and conjugated aromatic structures that favor the absorption of the ultraviolet radiation, are studied compounds for various purposes and present in various plants, thus constituting a natural structure. In the planning, the choice of such structures was also due to the synthesis of compounds of high molar mass (above 900 daltons), contributing to safe structures, with low toxicity probability, low skin permeation and in compliance with the demands of the current legislation. The data obtained in the work reinforce the success of the same, where we had for the prototypes synthesized, molar absorptions superior to commercial filters. Establishing a​​research with the use of chalcones in safe and efficient sunscreens. / É sabido que a exposição solar é um dos fatores de grande contribuição para o surgimento do câncer. Casos de câncer tem surgido anualmente no planeta e muitos desses casos tem direta correlação com a exposição solar. Sabendo que tanto a radiação UVA quanto a UVB são nocivas à saúde quando o indivíduo é exposto em demasia, surge a necessidade do uso de artifícios para a proteção da pele e uma dessas maneiras e já reconhecida pelo meio científico é através do uso profilático de protetores solares. Assim este trabalho se propôs a síntese, caracterização estrutural, verificação de estabilidade térmica, cálculo de absortividade molar e fator de proteção solar UVB (FPUVB) in vitro calculado pelo método espectrofotométrico descrito por Mansur de novos compostos derivados de estruturas análogas a produtos naturais. O planejamento estrutural foi baseado nos derivados triazínicos (pois já são de uso comercial com relativa eficiência) e o uso de chalconas, que são estruturas que além de possuir duplas ligações e estruturas aromáticas conjugadas que favorecem a absorção da radiação ultravioleta, são compostos bastante estudados para diversos fins e presente em vários vegetais, constituindo assim uma estrutura natural. No planejamento, a escolha de tais estruturas se deu também pela síntese de compostos de alta massa molar (acima de 900 Daltons), contribuindo para estruturas seguras, com probabilidade de baixa toxicidade, baixa permeação cutânea e atendendo aos reclames das legislações vigentes. Os dados obtidos no trabalho reforçam o sucesso do mesmo, onde tivemos para os protótipos sintetizados, absorções molares superiores a filtros comerciais. Estabelecendo assim uma nova linha de pesquisas com a utilização de chalconas em filtros solares seguros e eficientes.

Page generated in 0.0432 seconds