Ferramenta computacional para análise do potencial de bombeamento de água utilizando aerogeradores de pequeno porte acoplados a motobombas por meio de inversores de frequênciaNASCIMENTO, Max Alexandre Seabra do 26 April 2012 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-03-20T18:01:59Z
No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_FerramentaComputacionalAnalise.pdf: 5164783 bytes, checksum: 86f7882d5ca2558eb263a396e1c96241 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-03-27T15:53:00Z (GMT) No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_FerramentaComputacionalAnalise.pdf: 5164783 bytes, checksum: 86f7882d5ca2558eb263a396e1c96241 (MD5) / Made available in DSpace on 2013-03-27T15:53:00Z (GMT). No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_FerramentaComputacionalAnalise.pdf: 5164783 bytes, checksum: 86f7882d5ca2558eb263a396e1c96241 (MD5)
Previous issue date: 2012 / FINEP - Financiadora de Estudos e Projetos / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / FAPESPA - Fundação Amazônia de Amparo a Estudos e Pesquisas / O objetivo desta dissertação é desenvolver uma ferramenta computacional para a análise do potencial de bombeamento de água com base nos valores de velocidades de vento de uma localidade, utilizando um aerogerador de pequeno porte acoplado a um conjunto motobomba convencional, por intermédio de um inversor de frequência. No trabalho são apresentados dois métodos para o cálculo da vazão. O método 1 utiliza um modelo teórico, enquanto que no método 2 o modelamento é feito a partir de dados de bombeamento obtidos em laboratório. Os dois métodos descrevem o funcionamento de um sistema de bombeamento de água envolvendo os equipamentos citados. Utilizando os modelos matemáticos descritos, foi criado um programa em linguagem Delphi®, para a obtenção dos valores de vazão e volume de água bombeada, além do número de pessoas que podem ser atendidas, com base nos dados de velocidade de vento do local, para com isso, ser possível analisar a viabilidade ou não de instalação do sistema. O funcionamento do programa é descrito através de um exemplo, que contém valores reais de velocidade de vento, e cujos resultados são analisados de forma a possibilitar seu entendimento. / The goal of this dissertation is to allow, through a computational tool, the analysis of the potential of a water pumping system based on the values of wind speeds in one location, using a small wind turbine coupled to a centrifugal pump through a variable speed drive. In the work two methods for the calculation of the flow are presented. Method 1 uses a theoretical model, while in method 2 the modeling is done from pumping data obtained in laboratory. The two methods describe the operation of a water pumping system involving the above equipment. Using the mathematical models described, a program was developed in Delphi® to obtain the values for the flow and volume of pumped water, and the number of people that can be supplied on the basis of the data of wind speed for the site, in order to analyze the feasibility of the system. The operation of the program is described through an example, in order to facilitate its understanding, which contains real values of wind speed, and the results are analyzed.
|
2 |
Tratamento de dejetos bovinos em sistema intensivo de produção de leite com aeração mecânica / Treatment of cattle manure in intensive system of production of milk with mechanical aerationAssenheimer, Adriane 29 March 2007 (has links)
Made available in DSpace on 2017-07-10T17:37:04Z (GMT). No. of bitstreams: 1
Adriane Assenheimer.pdf: 1563722 bytes, checksum: 86dc567faf8f5b3b7b7c293078fb7abb (MD5)
Previous issue date: 2007-03-29 / This work had as objective to evaluate the acting of an aeration equipment adopted in the treatment of dejections of bovine confined in the system ?free stall?, with the recycling of the diluted effluent in the cleaning of the facilities and subsequent use in the areas of cultivation of forages. A reactor was used, operated by the process of mud activated by ?boat-load? (LAB), with system of lingering and intermittent aeration, dimensioned for a time of hydraulic retention of 24 days, with dilution of the dejections in water in the proportion of volume 1:1. Samplings were accomplished in the entrance and inside the aeration tanks, in the exit of the irrigation tubulation and of the pure dejections of the animals. The following parameters were determined: pH, temperature, total Biochemical Oxygen Demand (BOD), total Chemical Oxygen Demand (COD), organic matter, total solids, total fixed solids, total solids suspended, solids suspended fixed, solids suspended volatile, total nitrogen, nitrogen amoniacal, potassium, phosphorus, total carbon, calcium and magnesium. High reductions of BOD (59,05%) and COD (48,16%) were reached for the irrigation effluent. Related to the stabilization of the organic matter, the relationship C/N of the irrigation effluent was of 13,9, indicating that the effluent was stabilized. Through the obtained results, it was found that the aeration system was efficient to reduce and to stabilize the organic matter of the liquid effluent, making possible the recycling in the cleaning of the facilities, providing considerable economy of water, with subsequent release of that treated effluent in the cultivation areas, improving the physical, chemical and biological characteristics of the soil / Este trabalho teve como objetivo avaliar o desempenho de um equipamento de aeração adotado no tratamento de dejetos de bovinos confinados em sistema free stall , com reciclagem do efluente diluído na limpeza das instalações e posterior utilização nas áreas de cultivo de forragens. Utilizou-se um reator, operado pelo processo de lodo ativado por batelada (LAB), com sistema de aeração prolongada e intermitente, dimensionado para um tempo de retenção hidráulica de 24 dias, com diluição dos dejetos em água na proporção de volume 1:1. Foram realizadas amostragens na entrada e no interior dos tanques de aeração, na saída da tubulação de irrigação e dos dejetos puros dos animais. Foram determinados os seguintes parâmetros: pH, temperatura, demanda bioquímica de oxigênio (DBO) e demanda química de oxigênio (DQO) totais, matéria orgânica, sólidos totais, sólidos voláteis totais, sólidos fixos totais, sólidos suspensos totais, sólidos suspensos fixos, sólidos suspensos voláteis, nitrogênio total, nitrogênio amoniacal, potássio, fósforo, carbono total, cálcio e magnésio. Altas reduções de DBO (59,05%) e DQO (48,16%) foram alcançadas para o efluente de irrigação. Com relação à estabilização da matéria orgânica, a relação C/N do efluente de irrigação foi de 13,9, indicando que o efluente foi estabilizado. Através dos resultados obtidos, conclui-se que o sistema de aeração foi eficiente para reduzir e estabilizar a matéria orgânica do efluente líquido, tornando possível a sua reciclagem na limpeza das instalações, proporcionando economia considerável de água, com posterior lançamento desse efluente tratado nas áreas de cultivo, melhorando as características físicas, químicas e biológicas do solo
|