Spelling suggestions: "subject:"aerogenerators"" "subject:"termogenerators""
1 |
Estudo e comparação de sistemas de geração eólica utilizando DFIG e PMSG / Study and comparation of wind energy systems using DFIG and PMSGCorrêa, André da Silva 20 February 2015 (has links)
Made available in DSpace on 2016-12-12T17:38:33Z (GMT). No. of bitstreams: 1
Andre da Silva Correa.pdf: 3150015 bytes, checksum: 8df17c41e03f4cea1d464cb6c5d5b970 (MD5)
Previous issue date: 2015-02-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Given the increased contribution of wind farms under complementarity the generating units of electricity derived from petroleum, thermoelectric or hydroelectric energy matrix constituents of countries around the world, this dissertation investigates the advantages and disadvantages between the two main topologies currently used by rogue wind generation. Comparisons between the Doubly Fed Induction Generator and Permanent Magnet Generator are developed in order to establish the different dynamic behavior of each type of wind unit. The constituent parts of wind turbines are studied, performed the modeling and usual control methods are discussed. The simulations were performed in a computer program Matlab / Simulink® whose control models were developed according to the literature, as well as the respective block diagrams for each model. / Diante do crescimento da contribuição dos parques eólicos em regime de complementaridade às unidades geradoras de energia elétrica derivadas de petróleo, termoelétricas ou hidroelétricas constituintes da matriz energética de países espalhados pelo mundo, a presente dissertação de mestrado investiga as vantagens e desvantagens entre as duas principais topologias utilizadas atualmente para geração eólica. São estabelecidas comparações entre o Gerador de Indução Duplamente Alimentado e o Gerador de Ímãs Permanentes, a fim de se estabelecer os diferentes comportamentos dinâmicos de cada tipo de unidade eólica. São estudadas as partes constituintes de aerogeradores, realizadas as modelagens e discutidos os métodos de controle usuais. As simulações foram realizadas em programa computacional Matlab/Simulink®, cujos modelos de controle foram desenvolvidos de acordo com a literatura, assim como os respectivos diagramas de bloco para cada modelo.
|
2 |
Estudos de estabilidade de sistemas elétricos de potência na presença de diferentes modelos de unidades eólicas / Stability analysis of power systems in the presence of wind generation plants with different modelsAlexandre Prodóssimo Sohn 19 February 2014 (has links)
Diante da crescente penetração da energia elétrica gerada por unidades eólicas no sistema elétrico de inúmeros países, a presente dissertação de mestrado investiga os problemas de estabilidade transitória, para geradores síncronos, de estabilidade de tensão, para geradores síncronos e aerogeradores e de estabilidade de velocidade, para aerogeradores, em sistemas de transmissão de energia elétrica, frente a grandes perturbações. São estabelecidas comparações entre os diferentes comportamentos dinâmicos de cada tipo de unidade eólica, referentes aos tipos A, B, C e D. Também, são verificados os efeitos de contingências aplicadas a sistemas teste, na presença de sistemas de geração convencionais dotados de geradores síncronos e parques eólicos compostos pelos tipos de unidades eólicas citadas, a fim de verificar a relação entre os diferentes sistemas de geração. As simulações realizadas contemplam aspectos dinâmicos de modelos genéricos de aerogeradores. São estudadas as partes constituintes de aerogeradores, realizadas as modelagens e discutidos os métodos de controle usuais. As principais características dos modelos genéricos de unidades eólicas, assim como os respectivos diagramas de bloco para cada modelo são apresentados. As simulações são realizadas no programa computacional PSS/E, cujos modelos, já validados, representam aerogeradores reais de fabricantes distintos. É observado que as diferentes características dos modelos de unidades eólicas e as estratégias de controle empregadas para atenuar os efeitos negativos de contingências impostas ao sistema, influenciam significativamente o perfil da tensão e o fluxo de potência na rede elétrica. Este fato é refletido em diferentes respostas dos sistemas de geração. As unidades eólicas mostram-se resistentes à perderem a estabilidade e apresentam-se capazes de estabilizar um sistema elétrico de potência, devido aos mecanismos de controle de velocidade e potência dos mesmos. A violação da curva LVRT mostra-se a principal causa da desconexão de aerogeradores da rede elétrica. Verifica-se neste trabalho que os aerogeradores somente tornam-se instáveis quando os geradores síncronos perdem o sincronismo, ou quando o controle do torque aerodinâmico é desconsiderado. / Considering the growing penetration of electrical energy generated by wind turbines in the power system of numerous countries, the present masters dissertation investigates the problems of transient stability, for synchronous generators, voltage stability, for synchronous generators and aerogenerators, and velocity stability, for aerogenerators, in transmission systems, before large disturbances. Comparisons are made between the different dynamic behaviors of each type of wind energy conversion system, namely types A, B, C and D. The effects of contingencies in some test systems in the presence of wind farms with different types of aerogenerators and conventional synchronous generators are verified, whose aim of the simulations is to analyze the relation between the different generation systems. The simulations performed contemplate dynamic aspects of generic models of wind turbines. The components of wind turbines are studied, the modeling of these components is elaborated and the usual control methods are discussed. The main characteristics of generic wind models and the diagram blocks are presented. The simulations were performed in software PSS/E, whose models already validated, represent real machines. The different characteristics of aerogenerator models and the control strategies employed to mitigate the negative consequences, from several contingencies, significantly influence the voltage profile and the power flow network. This fact implies in different responses of generation systems. It is verified that wind generators are very robust to perturbations and contribute to the stabilization of synchronous generators in a power system, increasing the average critical clearing times. Unstable modes related to the acceleration of the wind generator rotor are hardly ever observed due to the existing mechanisms of control of speed and generated power. It is observed that violation of the LVRT curve is the main cause of disconnection of wind turbines from the grid and it consists of the main cause of power system collapse triggered by problems in this type of generators.
|
3 |
Estudos de estabilidade de sistemas elétricos de potência na presença de diferentes modelos de unidades eólicas / Stability analysis of power systems in the presence of wind generation plants with different modelsSohn, Alexandre Prodóssimo 19 February 2014 (has links)
Diante da crescente penetração da energia elétrica gerada por unidades eólicas no sistema elétrico de inúmeros países, a presente dissertação de mestrado investiga os problemas de estabilidade transitória, para geradores síncronos, de estabilidade de tensão, para geradores síncronos e aerogeradores e de estabilidade de velocidade, para aerogeradores, em sistemas de transmissão de energia elétrica, frente a grandes perturbações. São estabelecidas comparações entre os diferentes comportamentos dinâmicos de cada tipo de unidade eólica, referentes aos tipos A, B, C e D. Também, são verificados os efeitos de contingências aplicadas a sistemas teste, na presença de sistemas de geração convencionais dotados de geradores síncronos e parques eólicos compostos pelos tipos de unidades eólicas citadas, a fim de verificar a relação entre os diferentes sistemas de geração. As simulações realizadas contemplam aspectos dinâmicos de modelos genéricos de aerogeradores. São estudadas as partes constituintes de aerogeradores, realizadas as modelagens e discutidos os métodos de controle usuais. As principais características dos modelos genéricos de unidades eólicas, assim como os respectivos diagramas de bloco para cada modelo são apresentados. As simulações são realizadas no programa computacional PSS/E, cujos modelos, já validados, representam aerogeradores reais de fabricantes distintos. É observado que as diferentes características dos modelos de unidades eólicas e as estratégias de controle empregadas para atenuar os efeitos negativos de contingências impostas ao sistema, influenciam significativamente o perfil da tensão e o fluxo de potência na rede elétrica. Este fato é refletido em diferentes respostas dos sistemas de geração. As unidades eólicas mostram-se resistentes à perderem a estabilidade e apresentam-se capazes de estabilizar um sistema elétrico de potência, devido aos mecanismos de controle de velocidade e potência dos mesmos. A violação da curva LVRT mostra-se a principal causa da desconexão de aerogeradores da rede elétrica. Verifica-se neste trabalho que os aerogeradores somente tornam-se instáveis quando os geradores síncronos perdem o sincronismo, ou quando o controle do torque aerodinâmico é desconsiderado. / Considering the growing penetration of electrical energy generated by wind turbines in the power system of numerous countries, the present masters dissertation investigates the problems of transient stability, for synchronous generators, voltage stability, for synchronous generators and aerogenerators, and velocity stability, for aerogenerators, in transmission systems, before large disturbances. Comparisons are made between the different dynamic behaviors of each type of wind energy conversion system, namely types A, B, C and D. The effects of contingencies in some test systems in the presence of wind farms with different types of aerogenerators and conventional synchronous generators are verified, whose aim of the simulations is to analyze the relation between the different generation systems. The simulations performed contemplate dynamic aspects of generic models of wind turbines. The components of wind turbines are studied, the modeling of these components is elaborated and the usual control methods are discussed. The main characteristics of generic wind models and the diagram blocks are presented. The simulations were performed in software PSS/E, whose models already validated, represent real machines. The different characteristics of aerogenerator models and the control strategies employed to mitigate the negative consequences, from several contingencies, significantly influence the voltage profile and the power flow network. This fact implies in different responses of generation systems. It is verified that wind generators are very robust to perturbations and contribute to the stabilization of synchronous generators in a power system, increasing the average critical clearing times. Unstable modes related to the acceleration of the wind generator rotor are hardly ever observed due to the existing mechanisms of control of speed and generated power. It is observed that violation of the LVRT curve is the main cause of disconnection of wind turbines from the grid and it consists of the main cause of power system collapse triggered by problems in this type of generators.
|
Page generated in 0.4906 seconds