• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Critical characteristics for corticosteroid solution metered dose inhaler bioequivalence

Grainger, C.I., Saunders, M., Buttini, F., Telford, Richard, Merolla, L.L., Martin, G.P., Jones, S.A., Forbes, B. 15 October 2019 (has links)
No / Determining bioequivalence for solution pressurized metered dose inhalers (pMDI) is difficult because the critical characteristics of such products are poorly defined. The aim of this study was to elucidate the non-aerodynamic properties of the emitted aerosol particles from two solution pMDI products that determine their biopharmaceutical differences after deposition. Novel particle capture and analysis techniques were employed to characterize the physicochemical and biopharmaceutical properties of two beclomethasone dipropionate (BDP) products: QVAR and Sanasthmax. The BDP particles emitted from the Sanasthmax inhaler were discernibly different those emitted from QVAR in terms of size (50% larger, less porous), solid state (less crystalline) and dissolution (20-fold slower). When deposited onto the surface of respiratory epithelial cell layers, QVAR delivered ∼50% more BDP across the cell layer in 60 min than Sanasthmax. Biopharmaceutical performance was not attributable to individual particle properties as these were manifold with summative and/or competing effects. The cell culture dissolution− absorption model revealed the net effect of the particle formed on drug disposition and was predictive of human systemic absorption of BDP delivered by the test inhalers. This illustrates the potential of the technique to detect the effect of formulation on the performance of aerosolized particles and contribute to assessment of bioequivalence. / This work was in part funded by a grant from the Safety and Environmental Assurance Centre, Unilever Colworth, U.K. Particle sizing was performed by Steve Ingham, Institute of Pharmaceutical Science, King’s College London.
2

Comparative study of immunodeficient rat strains in engraftment of hiPSC-derived airway epithelia / ヒトiPS細胞由来気道上皮移植における免疫不全ラット系統の比較検討

林, 泰之 23 May 2024 (has links)
京都大学 / 新制・課程博士 / 博士(医学) / 甲第25488号 / 医博第5088号 / 新制||医||1073(附属図書館) / 京都大学大学院医学研究科医学専攻 / (主査)教授 後藤 慎平, 教授 平井 豊博, 教授 浅野 雅秀 / 学位規則第4条第1項該当 / Doctor of Medical Science / Kyoto University / DFAM
3

A numerical study of periciliary liquid depth in MDCT-based human airway models

Wu, Dan 01 May 2015 (has links)
Periciliary liquid (PCL) is a critical component of the respiratory system for maintaining mucus clearance. As PCL homeostasis is affected by evaporation and mechanical forces, which are in turn affected by various breathing conditions, lung morphology and ventilation distribution, the complex process of PCL depth regulation in vivo is not fully understood. We propose an integrative approach to couple a thermo-fluid computational fluid dynamics (CFD) model with an epithelial cell model to study the dynamics of PCL depth using subject-specific human airway models based on multi-detector row computed-tomography (MDCT) volumetric lung images. The thermo-fluid CFD model solves three-dimensional (3D) incompressible Navier-Stokes and transport equations for temperature and water vapor concentration with a realistic energy flux based boundary condition imposed at airway wall. A corresponding one-dimensional (1D) thermo-fluid CFD model is also developed to provide necessary information to the 3D model. Both 1D and 3D models are validated with experimental measurements, and the temperature and humidity distributions in the airways are investigated. Correlations for the dimensionless parameters of Nusselt number and Sherwood number are proposed for characterizing heat and mass transfer in the airways. As one of the key applications of the thermo-fluid CFD model, the water loss rates in the both 1D and 3D airway models are studied. It is found that the secondary flows formed at the bifurcations elevate the regional heat and mass transfer during inspiration and hence the water loss rate, which can only be observed in the 3D models. Among the three human airway models studied in both 1D and 3D, little inter-subject variability is observed for the distributions of temperature and humidity. However, the inter-subject variability could be dramatic for the distribution of water loss rate, as it is greatly affected by airway diameter and regional ventilation. A method is proposed to construct an ion-channel conductance model for both normal and cystic fibrosis (CF) epithelial cells, which couples an existing fluid secretion model with an existing nucleotide and nucleoside metabolism model (collectively named epithelial cell model). The epithelial cell models for both normal and CF are capable of predicting PCL depth based on mechanical stresses and evaporation, and are validated with a wide range of experimental data. With these two models separately validated and tested, the integrated model of the thermo-fluid CFD model and epithelial cell model is applied to MDCT-based human airway models of three CF subjects and three normal subjects to study and compare PCL depth regulation under regular breathing conditions. It is found that evaporative water loss is the dominant factor in PCL homeostasis. Between three types of mechanical forces, cyclic shear stress is the primary factor that triggers ATP release and increases PCL depth. In addition, it is found that that greater diameters of the airways in the 4th-7th generations in CF subjects decrease evaporative water loss, resulting in similar PCL depth as normal subjects. Under regular breathing conditions, the average PCL depths of normal and CF is around 6 to 7 µm, with mechanical forces play a greater role in regulating CF PCL depth. Comparing to 7.68 µm normal base level (considered as optimum PCL depth), this average PCL depth is about 8 to 21% lower. This might suggest that mechanical forces alone cannot entirely balance evaporative water loss, and other mechanisms might be involved.

Page generated in 0.047 seconds