• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Akustikreglering i kulturhistorisk bruksmiljö / Acoustic control in industrial cultural buildings  Författare:

Mattias, Hallberg January 2020 (has links)
En äldre industribyggnad är oftast byggd i hårda material så som tegel, stål och plåt vilket alla ger upphov till hög andel reflektioner av ljudenergi. Absorptionsnivån i dessa material är låga vilket leder till långa efterklangstider. Att montera in akustikreglerande åtgärder i dessa byggnader står i konflikt med att äldre industribyggnader ofta har ett kulturhistoriskt värde.  Syftet med arbetet var att undersöka möjligheten till att genomföra akustikreglering i en kulturhistoriskt värdefull byggnad utan att väsentligt påverka detta värde. Avseende ambitionsnivån ur akustisk synpunkt var målet att halvera efterklangstiden.  De genomförda efterklangstidsmätningarna visar på en relativ lång efterklangstid i mellanregistret och en kortare vid låga och höga frekvenser. Resultatet av de beräkningar som är genomförda visar att i den mindre, av två stycken, hyttan kan målet med en halverad efterklangstid uppnås för majoriteten av oktavbanden. Åtgärdsförslaget för den större hyttan skulle däremot inte leda till att målet uppfylls fullt ut, utan för detta skulle ytterligare åtgärder behöva sättas in. Hänsyn till hyttans kulturvärde motiverar dock att en längre efterklangstid kan accepteras. / An older industrial building is usually built in hard materials such as brick, steel and sheet metal, all of which give rise to a high proportion of reflections of sound energy. The absorption level in these materials is low, which leads to long reverberation times. Installing acoustic regulatory measures in these buildings conflicts with the fact that older industrial buildings often have a cultural-historical value.  The purpose of this work was to investigate the possibility of implementing acoustic regulations in a culturally and historically valuable building without substantially affecting its cultural value. Regarding the level of ambition from an acoustic perspective, the objective was to halve the reverberation time.  The measured reverberation time shows a relative long reverberation time in the mid frequencies and a shorter one at low and high frequencies. The results of the calculations that have been carried out show that in the smaller production hall, of two, the objective of a halved reverberation time can be achieved in the majority of the octave bands. The proposed measures for the larger production hall would not lead to the objective being fully met, but further measures would need to be implemented. Consideration of the cultural value of the glass factory justifies that a longer reverberation time can be accepted.

Page generated in 0.0473 seconds