• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Bioensaios de toxicidade utilizando invertebrados aquáticos em exposição ao Alquilbenzeno Linear Sulfonado / Toxicity bioassays using aquatic invertebrates in exposure to the Linear Alkylbenzene Sulfonate

Felipe, Mayara Caroline 26 March 2019 (has links)
Alquilbenzeno Linear Sulfonado (LAS) é o surfactante aniônico mais utilizado no mundo e é encontrado constantemente em esgoto doméstico e águas residuárias de lavanderia. A remoção de LAS em reatores foi comprovada em estudos anteriores, mas pouco se sabe sobre a toxicidade desse composto em amostras mais complexas para a biota aquática. Neste trabalho, objetivou-se avaliar duas Hipóteses; A: O LAS padrão causa efeitos negativos na biota aquática, e B: O tratamento em reator de leito fluidificado de amostra complexa contendo LAS (água residuária de lavanderia comercial combinada com esgoto doméstico bruto) diminui os efeitos negativos na biota aquática. Ambas as hipóteses foram avaliadas por meio de bioensaios de toxicidade com: Chironomus sancticaroli, Allonais inaequalis e Daphnia magna, analisados a partir da mortalidade dos organismos e análises estatísticas, para determinar os efeitos tóxicos dos LAS padrão e das amostras do reator, comparados ao controle. Para avaliar a Hipótese A foram realizados testes de toxicidade aguda, crônica e crônica de gerações com o LAS padrão. No teste de toxicidade crônica de gerações, com a espécie C. sancticaroli, foram analisados a deformidade bucal, comprimento das larvas, tamanho das asas das fêmeas e fecundidade potencial com o LAS padrão em 3 gerações. Para responder a Hipótese B, foram realizados bioensaios de toxicidade aguda e crônica com os afluentes, efluentes e diluições dos efluentes nas seis fases de operação do reator. C. sancticaroli foi a espécie mais tolerante tanto em teste de toxicidade aguda como crônica com LAS padrão (CL50-96h 25,25 mg.L-1 e CL50-10dias 18,11 mg.L-1), seguido de A. inaequalis (CL50-96h 8,13 mg.L-1 e CL50-10dias 8,56 mg.L-1). A espécie mais sensível ao LAS foi D. magna (CE50-48h 6,11mg.L-1 e CE50-21dias 3,21 mg.L-1). No teste de toxicidade crônica de longa duração, não existiu diferença estatística entre as gerações para o desenvolvimento das larvas do inseto C. sancticaroli, entretanto evidenciaram diferença estatística entre as gerações quanto ao tamanho das asas das fêmeas, indicando que esses organismos podem sofrer alterações fisiológicas quando a exposição ao contaminante é contínua, confirmando a Hipótese A. Os resultados ecotoxicológicos com o reator evidenciaram toxicidade de 100% de todos afluentes e efluentes para A. inaequalis e D. magna. Já C. sancticaroli apresentou menor toxicidade nas primeiras fases de operação (de 20 a 100% de mortalidade). Em geral, foi identificado diferença de toxicidade das fases do reator por meio das diluições. Nas fases menos tóxicas, a diminuição da mortalidade era observada a partir de diluição de 50%; nas fases mais tóxicas, a partir de 20%. É possível concluir que a Fase VIb de operação do reator apresentou diminuição da toxicidade. Entretanto, ao se analisar testes de toxicidade crônica nessa fase, conclui-se que o efluente mesmo depois do tratamento em reator causa efeito negativo nos organismos-teste avaliados, dessa forma é possível refutar a Hipótese B. A partir dos resultados apresentados, é possível concluir que o LAS causa impacto ambiental, principalmente em exposição continua, e que mesmo com remoção em sistema biológico de efluentes reais (água residuária de lavanderia comercial combinada com esgoto doméstico) existe impacto, possivelmente com a interação entre os diversos compostos tóxicos e o LAS. / Linear Alkylbenzene Sulfonate (LAS) is the most commonly utilized anionic surfactant in the world and it is present in domestic sewage and laundry wastewater. Removal of LAS in reactors has been proven in previous studies, but little is known about the toxicity to the aquatic biota. The objectives of this study were tested into two Hypotheses, A: The standard surfactant LAS causes negative effects on aquatic biota, and B: Treatment in complex sample fluidized bed reactor containing LAS (commercial laundry wastewater combined with raw domestic sewage) diminishes the negative effects on aquatic biota. Both Hypotheses were evaluated toxicity bioassays using three test organisms: Chironomus sancticaroli, Allonais inaequalis and Daphnia magna. To evaluate the Hypothesis A, acute, chronic and long-term chronic toxicity tests were performed with standard LAS. In the long-term chronic tests with C. sancticaroli organisms, we analyzed the oral deformity, larval length, female wing size and potential fecundity in contact with the standard LAS in 3 generations. Acute and chronic bioassays with affluents, effluents and effluent dilutions in the VI operating phases of the fluidized bed reactor were proceeded to evaluate the Hypothesis B. The results were analyzed from the mortality of the organisms, and statistical analysis were performed to determine the similarity of the toxic effects of the LAS and reactor samples, compared to the control. The species C. sancticaroli was the most tolerant species in both acute and chronic trials with standard LAS (LC50-96h 25.25 mg.L-1 and LC50- 10 days 18.11 mg.L-1), followed by species of A. inaequalis (LC50-96h 8.13 mg.L-1 and LC50-10 days 8.56 mg.L-1). The species most sensitive to LAS was D. magna (CE50-48h 6.11mg.L-1 and CE50-21dias 3.21mg.L-1). In the long-term chronic test, there is no statistical difference between the generations for the development of C. sancticaroli insect larvae. However, they showed a statistical difference between the generations regarding the size of the female wings, indicating that these organisms may undergo physiological changes when exposure to the contaminant is continuous. From these results it is possible to confirm Hypothesis A. The ecotoxicological results with the reactor showed toxicity of 100% of all tributaries and effluents for A. inaequalis and D. magna. The C. sancticaroli species had low toxicity in the first stages of operation (from 20 to 100% mortality). In general, toxicity difference of the reactor phases was identified by half of the dilution analysis. In the less toxic phases, the decrease in mortality was observed from 50% dilution; in the most toxic phases, from 20%. It is also possible to conclude that Phase VIb showed a decrease in the mortality of the test organisms where a chronic test was performed. However, when analyzing the chronic tests, it can be concluded that the effluent even after the treatment in the reactor causes a negative effect on the test organisms evaluated, so it is possible to refute the Hypothesis B. From the results presented, it is possible to conclude that the LAS causes environmental impact, mainly in continuous exposure, and that even with treatment of actual effluents (commercial laundry wastewater combined with domestic sewage) there is an impact, possibly with the interaction between the various toxic compounds and the LAS.
2

Testes ecotoxicológicos para avaliação do potencial impacto ambiental em corpos receptores por efluente de Estação de Tratamento de Esgoto / Ecotoxicological tests to evaluate the potential environmental impact in receiving bodies by effluent from Sewage Treatment Plant

Issa, Carina Graminha 22 March 2019 (has links)
O crescimento das cidades sem planejamento adequado tem como consequências a ampla geração e incorreta destinação de resíduos sólidos e líquidos e a falta de esgotamento sanitário adequado, resultando em impactos negativos ao meio ambiente e aos corpos hídricos. O esgoto doméstico é composto predominantemente por matéria orgânica, além de nitrogênio, fósforo, organismos patogênicos e elementos potencialmente tóxicos (e.g.: fármacos), que podem ou não ser removidos nas estações de tratamento de esgoto. Esse efluente final (esgoto tratado), é encaminhado para o corpo receptor, normalmente um rio ou córrego. Quando não removidos durante os processos de tratamento, os compostos remanescentes no esgoto podem causar alterações físicas, químicas e principalmente biológicas nos corpos receptores. Entre as principais alterações biológicas destaca-se a perda de biodiversidade aquática presente no corpo hídrico receptor. O presente trabalho avaliou o possível impacto ambiental causado pelo efluente final de Estação de Tratamento de Esgoto (E.T.E.) em corpos hídricos receptores por meio de testes ecotoxicológicos. Foram selecionadas três estações de tratamento de esgoto, as quais foram avaliadas. Foram coletadas amostras do afluente bruto (P0), efluente final (P1), um ponto a montante (P2) e um ponto a jusante (P3) da mistura do esgoto com o corpo receptor de cada estação. Foram realizados ensaios de toxicidade aguda utilizando as espécies de invertebrados aquáticos Daphnia magna, Chironomus sancticaroli, Allonais inaequalis. Os organismos foram expostos às amostras coletadas para avaliação da sobrevivência. Para a E.T.E. 1, foi constatado adequada eficiência de remoção de toxicidade do esgoto quando comparado o afluente bruto ao efluente tratado, e não foram observados impactos do lançamento do efluente no corpo receptor. A E.T.E. 2, mostrou baixa eficiência de remoção de toxicidade do afluente bruto para o efluente tratado, refletindo em potencial tóxico a longo prazo ao corpo receptor. Da mesma forma, a E.T.E. 3 se mostrou ineficiente para remoção de toxicidade do afluente bruto para o efluente tratado, que refletiu em potencial tóxico ao corpo receptor em longo prazo. De acordo com os resultados obtidos no presente estudo, ressalta-se a importância da utilização de testes ecotoxicológicos como complementação aos parâmetros físicos e químicos exigidos pela legislação para avaliação da eficiência de remoção de contaminantes presentes no esgoto e que possuem potencial para geração de impacto a curto ou longo prazo à biota aquática presente no corpo hídrico receptor. / The increase of cities, without adequate planning, results in the wide generation and incorrect destination of solid and liquid wastes and the lack of adequate sanitary structure, resulting in negative impacts on the environment. Domestic sewage is composed predominantly of organic matter, in addition to nitrogen, phosphorus, pathogenic organisms and potentially toxic elements (e.g., drugs), which may or may not be removed at sewage treatment plants. This final effluent (treated sewage) is conveyed to water bodies, usually a river or stream. When not removed during the treatment processes, the remaining compounds in the sewage can cause physical, chemical and especially biological changes in the water bodies. Among the main biological changes is the loss of aquatic biodiversity present in the receiving water body. Thus, the present study evaluated the possible environmental impact caused by the final effluent from Sewage Treatment Plant (S.T.P.) in receiving water bodies by means of ecotoxicological tests. Three sewage treatment stations were selected. Samples of the raw tributary (P0), final effluent (P1) and the upstream (P2) and downstream (P3) points of the sewage mixture with the receiving body of each station were collected. Acute tests were carried out using the aquatic species Daphnia magna, Chironomus sancticaroli, Allonais inaequalis. The organisms were exposed to the samples collected for evaluation of survival in acute tests. For E.T.E. 1, it was found good toxicity removal efficiency of the station when comparing the raw affluent to the treated effluent, and no impacts of effluent release on the receiving body were observed. E.T.E. 2, showed low toxicity removal efficiency from the raw affluent to the treated effluent, reflecting long term toxic potential to the water body. Likewise, E.T.E. 3 was shown to be inefficient to remove toxicity from the raw affluent to the treated effluent, which reflected toxic potential to the water body in long term. According to the results obtained in the present study, the importance of the use of ecotoxicological tests as complementation of the physical and chemical parameters required by the legislation to evaluate the efficiency of removal of pollutants present in the sewage that have potential to generate impact in the short or long term to aquatic biota present in the body water recipient.

Page generated in 0.0486 seconds