• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Biosusceptometria de corrente alternada para avaliação de esvaziamento gástrico e trânsito gastrintestinal /

Quini, Caio César. January 2011 (has links)
Orientador: José Ricardo de Arruda Miranda / Banca: Luciana Corá / Banca: Clélia Akiko Hiruma Lima / Resumo: O trato gastrintestinal (TGI) constitui um grupo de importantes atividades motoras, es-sencial à vida. Uma série de metodologias é empregada no estudo dessas atividades e das patologias a elas associadas. No entanto, estas técnicas são geralmente invasivas, requerem cirurgia, inserção do cateter, ou, para a construção de um modelo temporal destas funções, demandam o sacrifício de uma série de animais na obtenção dos dados necessários. A Biosusceptometria de Corrente Alternada (BAC) é uma técnica biomagnética de baixo custo, portá-til, não-invasiva, livre de radiação ionizante, que pode ser utilizada para avaliar as proprieda-des do TGI pelo monitoramento da posição e concentração de materiais ferromagnéticos, usa-dos como marcadores magnéticos. O objetivo desta dissertação foi, através de um sistema BAC associado a marcadores magnéticos, apresentar uma nova forma de analisar propriedades do trato gastrintestinal, co-mo o esvaziamento gástrico e tempo de trânsito gastrointestinal, de alimentos sólidos e líqui-dos em modelos animais de pequeno porte. Um sistema dedicado foi construído para analisar estas propriedades. A instrumenta-ção consiste em dois pares de bobinas, um de referência e outro para a detecção. Cada par é composto por uma bobina de excitação e uma detecção. Uma linha de base fixa separa os pa-res de detecção e referência, e funciona também como suporte para a instrumenta-ção. Também é importante ressaltar que as bobinas de detecção são dispostas em uma confi-guração gradiométrica. Seu princípio de funcionamento baseia-se em um transformador de fluxo magnético, que o par (excitação e detecção), localizado mais distante da amostra magnética funciona co-mo uma referência para o sistema. Assim, quando se aproxima um material magnético... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The gastrointestinal tract (GIT) motor activities constitute an important group, essen-tial to life. A series of methodologies is employed in the study of these activities and its asso-ciated pathologies. However, these techniques are generally invasive, require surgery, catheter insertion or, in the temporal model construction issue, require the sacrifice of a series of ani-mals to record the necessary data. The Biosusceptometry of Alternate Current (BAC) is a low cost biomagnetic technique, portable, non-invasive and radiation free, which can be used to evaluate GIT properties by monitoring position and concentration of ferromagnetic materials when used as magnetic markers. The objective of this dissertation was to present a new way to measure GIT properties like gastric emptying and gastrointestinal transit time of both solid and liquid food in small animal models, using the BAC system associated with magnetic markers. A dedicated biosusceptometry system was constructed to analyze these particular properties. The instrumentation is constituted of two coil pairs, one for reference and another for detection. Each pair consists of an excitation coil and a detection one. A fixed baseline separates the detection and reference pairs, and works also as support to the instrumentation. It is also important to point that the detection coils are arranged in a gradiometric connection. Its working principle is based on a magnetic flux transformer, which the pair (excita-tion and detection) located farther from the sample works as a reference. Thus, when ap-proaching a magnetic material to the sensor, the balance created between the two faces of the sensor will be broken. This imbalance can be measured, digitalized and acquired. The mag-netic tracer used in the liquid transit determination was a commercial... (Complete abstract, click electronic access below) / Doutor
2

Biosusceptometria de corrente alternada para avaliação de esvaziamento gástrico e trânsito gastrintestinal

Quini, Caio César [UNESP] 27 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-27Bitstream added on 2014-06-13T21:01:41Z : No. of bitstreams: 1 quini_cc_me_botib.pdf: 604874 bytes, checksum: 6395053c8e32771be0353a9c71b35966 (MD5) / O trato gastrintestinal (TGI) constitui um grupo de importantes atividades motoras, es-sencial à vida. Uma série de metodologias é empregada no estudo dessas atividades e das patologias a elas associadas. No entanto, estas técnicas são geralmente invasivas, requerem cirurgia, inserção do cateter, ou, para a construção de um modelo temporal destas funções, demandam o sacrifício de uma série de animais na obtenção dos dados necessários. A Biosusceptometria de Corrente Alternada (BAC) é uma técnica biomagnética de baixo custo, portá-til, não-invasiva, livre de radiação ionizante, que pode ser utilizada para avaliar as proprieda-des do TGI pelo monitoramento da posição e concentração de materiais ferromagnéticos, usa-dos como marcadores magnéticos. O objetivo desta dissertação foi, através de um sistema BAC associado a marcadores magnéticos, apresentar uma nova forma de analisar propriedades do trato gastrintestinal, co-mo o esvaziamento gástrico e tempo de trânsito gastrointestinal, de alimentos sólidos e líqui-dos em modelos animais de pequeno porte. Um sistema dedicado foi construído para analisar estas propriedades. A instrumenta-ção consiste em dois pares de bobinas, um de referência e outro para a detecção. Cada par é composto por uma bobina de excitação e uma detecção. Uma linha de base fixa separa os pa-res de detecção e referência, e funciona também como suporte para a instrumenta-ção. Também é importante ressaltar que as bobinas de detecção são dispostas em uma confi-guração gradiométrica. Seu princípio de funcionamento baseia-se em um transformador de fluxo magnético, que o par (excitação e detecção), localizado mais distante da amostra magnética funciona co-mo uma referência para o sistema. Assim, quando se aproxima um material magnético... / The gastrointestinal tract (GIT) motor activities constitute an important group, essen-tial to life. A series of methodologies is employed in the study of these activities and its asso-ciated pathologies. However, these techniques are generally invasive, require surgery, catheter insertion or, in the temporal model construction issue, require the sacrifice of a series of ani-mals to record the necessary data. The Biosusceptometry of Alternate Current (BAC) is a low cost biomagnetic technique, portable, non-invasive and radiation free, which can be used to evaluate GIT properties by monitoring position and concentration of ferromagnetic materials when used as magnetic markers. The objective of this dissertation was to present a new way to measure GIT properties like gastric emptying and gastrointestinal transit time of both solid and liquid food in small animal models, using the BAC system associated with magnetic markers. A dedicated biosusceptometry system was constructed to analyze these particular properties. The instrumentation is constituted of two coil pairs, one for reference and another for detection. Each pair consists of an excitation coil and a detection one. A fixed baseline separates the detection and reference pairs, and works also as support to the instrumentation. It is also important to point that the detection coils are arranged in a gradiometric connection. Its working principle is based on a magnetic flux transformer, which the pair (excita-tion and detection) located farther from the sample works as a reference. Thus, when ap-proaching a magnetic material to the sensor, the balance created between the two faces of the sensor will be broken. This imbalance can be measured, digitalized and acquired. The mag-netic tracer used in the liquid transit determination was a commercial... (Complete abstract, click electronic access below)
3

Estudo da biodistribuição e determinação da eliminação de nanopartículas magnéticas em tempos longos por biosusceptometria de corrente alternada

Faria, João Victor Carneiro January 2020 (has links)
Orientador: José Ricardo de Arruda Miranda / Resumo: Nanopartículas magnéticas (NPMs) têm sido alvo de vários estudos por conta de sua versatilidade, que se destaca quando comparadas a outros materiais. NPMs apresentam tamanho reduzido, alta susceptibilidade magnética e devido a possibilidade de alteração química de revestimento, apresentam um alto poder teranóstico. Entretanto, antes de aplicá-los clinicamente é de extrema importância conhecer seus destinos e possibilidades de interação no organismo. A quantificação da biodistribuição de NPMs por meio de suas características intrínsecas ainda se mostra como um desafio. A Biosusceptometria de corrente alternada (BAC) é uma técnica biomagnética que atua detectando a quantidade de materiais magnéticos em ambientes biológicos. Essa técnica, em relação às demais presentes no mercado, apresenta baixo custo e portabilidade. Baseado na problemática em torno da detecção e quantificação de NPMs, nesse estudo foi analisada a biodistribuição e eliminação de NPMs de ferrita de manganês revestidas com citrato e albumina via sistema BAC. Para isso, foram utilizados 100 ratos Wistar, separados em 2 grupos experimentais (NPMs revestidas com albumina e citrato) e 10 subgrupos, variando o tempo de eutanásia dos animais (1, 4, 12, 24 e 48 horas e 5, 10, 15, 30 e 60 dias após a administração). Para análise da biodistribuição, foram coletados 5 órgãos de interesse: fígado, pulmão, baço, rins e coração, além do sangue e, para análise da eliminação, foram coletadas as fezes dos animais. Foi possível ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Magnetic nanoparticles (MNPs) have been widely used in several studies due to their high versatility compared to other materials. MNPs presents small size, high magnetic susceptibility and, due to the possibility of biochemical alteration of its surface, enables a high level of theranostics applications. However, before applying them clinically, it is of paramount importance understand its destinations and possibilities of interaction in the organism. The biodistribution quantification of NPMs through their intrinsic characteristics still is a challenge. Alternating current biosusceptometry (ACB) is a biomagnetic technique that acts detecting a quantity of magnetic materials in biological samples. In comparison with the other techniques, ACB presents low cost and portability. Based on the lack of accessible techniques to study biodistribution and elimination process of MNPs, this work aimed to analyze the biodistribution and determine the elimination of manganese ferrite magnetic nanoparticles coated with citrate and albumin via BAC system. For this work, we used 100 Wistar rats, separated into 2 experimental groups (MNPs coated with albumin and citrate) and 10 subgroups, changing the euthanasia time point (1, 4, 12, 24 and 48 hours and 5, 10, 15, 30 and 60 days after administration). For biodistribution analysis, we collected the blood and 5 organs of interest: liver, lung, spleen, kidneys and heart, and, for elimination analysis, we collected the animal’s feces. It was poss... (Complete abstract click electronic access below) / Mestre
4

Biosusceptometria de corrente alternada para avaliação da contratilidade uterina em ratas prenhes

Simões, Luís Gustavo de Oliveira. January 2019 (has links)
Orientador: José Ricardo de Arruda MIranda / Resumo: A contração uterina é um processo fisiológico espontâneo com impacto direto no ciclo menstrual/estral e na gestação. Disfunções na atividade uterina estão relacionadas com infertilidade, abortos e partos prematuros, sendo este último a maior causa de mortalidade e morbidade infantil no mundo. Sendo assim, se faz necessário o desenvolvimento de metodologias in vivo para monitorar o processo mecânico uterino. O objetivo deste trabalho foi aplicar a técnica de Biosusceptometria de Corrente Alternada para avaliação in vivo da atividade mecânica uterina em ratas prenhes. Foram utilizadas 40 ratas fêmeas Wistar prenhes com idade entre 10 e 15 semanas e com peso médio de 250 g. Através da Biosusceptometria de Corrente Alternada, 18 animais foram utilizados para avaliação da contratilidade uterina durante a prenhez e 8 foram usadas para avaliação da atividade uterina frente à ação da ocitocina. Na primeira etapa foi realizada uma cirurgia de fixação do marcador magnético em três posições da serosa uterina: próximo ao ovário; na região média entre o ovário e a cérvice; e próximo à cérvice. A atividade uterina foi monitorada nos dias 0, 7, 14, 20 e 21 de prenhez para cada posição do marcador. Na segunda etapa, foi realizado o implante do marcador magnético somente próximo à cérvice, e a atividade foi avaliada antes e depois da administração de ocitocina no dia 20 de prenhez. Os resultados obtidos foram perfis de contração para cada situação proposta, os quais apresentaram contrações ba... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Uterine contraction is a spontaneous physiologic process with direct impact on menstrual/estrous cycle and pregnancy. Uterine activity dysfunction are related with infertility, abortion and premature birth, in which the last is the major cause of childish mortality and morbidity in the world. Therefore, in vivo methods to assess the mechanical process of the uterus under real physiologic condition remains necessary to be developed. The aim of this study was to apply Alternate Current Biosusceptometry to assess in vivo mechanical uterine activity of pregnant rats. Forty Wistar female pregnant rats with 10 to 15 weeks age and weighing 250 g were used. Through Alternate Current Biosusceptometry, 30 animals were used for uterine contraction analysis during pregnancy and 10 were used to evaluate uterine contractility due to oxytocin action. On the first part, an implant surgery was performed to fix the magnetic marker on uterus serous at three different position: near ovary; middle distance between ovary and cervix, and near cervix. Uterine peristalsis were measured at days 0, 7, 14, 20 and 21 of pregnancy. On the second part, magnetic marker was implanted only on near cervix and uterine activity was evaluated before and after the oxytocin administration on day 20 of pregnancy. Contraction profiles were obtained as results to each proposed analysis, in which presented high frequency and low frequency basal contraction and intense contractions. During pregnancy evolution, was obser... (Complete abstract click electronic access below) / Doutor
5

Μέθοδοι βελτίωσης της μεταβατικής ευστάθειας σύνθετων ηλεκτρικών συστημάτων εναλλασσόμενου - συνεχούς ρεύματος

Μάρης, Θεόδωρος 16 November 2009 (has links)
- / -

Page generated in 0.1033 seconds