• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Concordância entre o débito cardíaco estimado através das técnicas de termodiluição transpulmonar e de análise de contorno de pulso e a técnica de termodiluição de artéria pulmonar em cães anestesiados com isoflurano

Garofalo, Natache Arouca January 2016 (has links)
Orientador: Francisco José Teixeira-Neto / Resumo: Introdução e objetivos: Mensurações do débito cardíaco (DC) pela técnica termodiluição transpulmonar (DCTP) e pela análise de contorno de pulso com calibração pela técnica transpulmonar (DCACP) são alternativas menos invasivas em comparação ao DC fornecido pela técnica de termodiluição de artéria pulmonar (DCP). Entretanto, instabilidades hemodinâmicas podem alterar o desempenho destes métodos. A Fase I do estudo objetivou avaliar se a utilização de 10 mL de indicador térmico (solução fisiológica a ≤ 5oC) para o DCTP (artéria femoral) promoveria melhor concordância e habilidade em detectar alterações no DCP em comparação a 5 mL de indicador. Na Fase II, objetivou-se verificar se alterações na resistência vascular sistêmica (RVS) influenciariam a concordância e a habilidade em detectar tendências entre o DCACP e o DCP. Métodos: Em 8 cães adultos (20,8–31,5 kg), mensurações simultâneas em triplicata do DCTP e DCP foram obtidas utilizando 5 e 10 mL de indicador térmico durante anestesia com isoflurano associado ou não com a infusão contínua intravenosa de remifentanil (0,3 e 0,6 μg/kg/min) ou de dobutamina (2,5 e 5,0 μg/kg/min) (Fase I). Durante a Fase II, o DCACP e o DCP foram mensurados simultaneamente (triplicata) antes e durante alterações na RVS induzidas pela infusão contínua de fenilefrina (1,0 μg/kg/min) ou de nitroprussiato (1,0 μg/kg/min). A acurácia e a precisão da concordância entre métodos foram estudadas pela análise de Bland-Altman para medidas múltiplas (Fase I) ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Background and objectives: Cardiac output (CO) measurements by transpulmonary thermodilution (TPTDCO) and by pulse contour analysis calibrated with transpulmonary thermodilution (PCACO) are less invasive alternatives to pulmonary artery thermodilution (PATDCO). However, hemodynamic instability could affect the performance of these methods. The objective of Phase I of the study was to determine if the use of 10 mL of thermal indicator (physiological saline at ≤ 5oC) for TPTDCO (measured in the femoral artery) would improve the agreement and trending ability with PATDCO in comparison to 5 mL of indicator. During Phase II, the aim was to verify if changes in systemic vascular resistance (SVR) would alter the agreement and trending ability between PCACO and PATDCO. Methods: In eight adult dogs (20.8–31.5 kg), simultaneous TPTDCO and PATDCO measurements (averaged from 3 repetitions) using 5 and 10 mL of thermal indicator were obtained during isoflurane anesthesia combined or not with intravenous remifentanil (0.3 e 0.6 μg/kg/min) or dobutamine (2.5 e 5.0 μg/kg/min) (Phase-1). During Phase-2, triplicate PCACO and PATDCO measurements were recorded before and during phenylephrine (1.0 μg/kg/min) or nitroprusside (1.0 μg/kg/min) induced changes in SVR. The accuracy and precision of agreement was evaluated by the Bland-Altman method for multiple measurements (Phase I) and for single measurements per subject (Phase 2). The ability of the test methods (PCACO and TPTDCO) to detect changes... (Complete abstract click electronic access below) / Doutor

Page generated in 0.1174 seconds