Spelling suggestions: "subject:"análise dde faltas"" "subject:"análise dee faltas""
1 |
Análise de faltas em sistemas elétricos de potência considerando dados incertos / Fault analysis in electric power systems considering uncertain dataRuback, Rodolfo Oliveira 02 August 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-03-13T20:53:05Z
No. of bitstreams: 1
rodolfooliveiraruback.pdf: 2343401 bytes, checksum: 8f9848927e2f5b7628d4e279716725d4 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-03-16T12:53:44Z (GMT) No. of bitstreams: 1
rodolfooliveiraruback.pdf: 2343401 bytes, checksum: 8f9848927e2f5b7628d4e279716725d4 (MD5) / Made available in DSpace on 2017-03-16T12:53:44Z (GMT). No. of bitstreams: 1
rodolfooliveiraruback.pdf: 2343401 bytes, checksum: 8f9848927e2f5b7628d4e279716725d4 (MD5)
Previous issue date: 2016-08-02 / A análise de faltas, também conhecida como análise de curto-circuito, é imprescindível tanto no âmbito de planejamento quanto na operação de um sistema elétrico de potência. Essa análise é geralmente realizada de forma determinística, para dados valores em um instante de tempo. Contudo, o sistema de potência é dinâmico e seus parâmetros estão sujeitos a variações. Desta forma, a utilização do modelo determinístico se torna inviável face as inúmeras simulações necessárias no sentido de representar todas as possíveis combinações das variações envolvidas no problema. Este trabalho propõe incorporar a matemática intervalar na análise de faltas, de modo a possibilitar a representação das incertezas dos parâmetros na forma de intervalos e, por conseguinte, gerar resultados intervalares de tensão e corrente na barra de falta, refletindo tais incertezas. Portanto, o objetivo básico é modelar e implementar um método para análise de faltas intervalar. Dois sistemas testes, um de 5 barras e outro de 14 barras, são utilizados para gerar as tensões e correntes intervalares no ponto de falta. Tais resultados são validados pela simulação de Monte Carlo. / Fault Analysis, also known as short-circuit analysis, is essential both in the planning and the operation of an electric power system. This analysis is usually done in a deterministic way for data values in an instant of time. However, the power system is dynamic and his parameters are subject to variations. Thus, using the deterministic model has become inaccurate face the numerous simulations required to represent all the combinations of possibles variations involved in the problem. This paper proposes to incorporate interval mathematics to fault analysis, in a way to represent the parameter uncertainties as intervals and therefore generate interval results of voltage and current in the short-circuited bar, reflecting these uncertainties. Therefore, the basic objective is to model and implement a method for interval fault analysis. Two test systems, one with 5 bars and the other with 14 bars, are used to generate voltages and currents interval in the fault point. These results are validated by Monte Carlo simulation.
|
2 |
MODELAGEM DE REDES AÉREAS COM RETORNO POR TERRA EM SISTEMAS DE DISTRIBUIÇÃO DE ENERGIA ELÉTRICA PARA ANÁLISES DE FALTAS DE ALTA IMPEDÂNCIA / MODELING OF AERIAL NETS WITH RETURN FOR LAND IN SYSTEMS OF DISTRIBUTION OF ELECTRIC ENERGY STOPS ANALYSES OF LACKS OF HIGH IMPEDANCESouza, Júlio César Nascimento 22 September 2006 (has links)
Made available in DSpace on 2016-08-17T14:53:02Z (GMT). No. of bitstreams: 1
Julio Cesar Nascimento Sousa.pdf: 971697 bytes, checksum: b4ee5e79977202a1c5eba4528ed34766 (MD5)
Previous issue date: 2006-09-22 / This work focuses on the modeling of single-phase and three-phase distribution with
earth return, for high impedance faults analysis. The main motivation is the lack of definitive
solutions for such faults. These faults often occur when an overhead conductor breaks and
falls on high impedance surface such as asphalt road, cement, trees, among others. That fault
is analyzed in a Single wire earth return system - SWER, and in a rural three-phase feeder.
The SWER is deduced starting from a generic three-phase system, where
simplifications based on practical assumptions are added. Simulations are accomplished in
two distribution test systems, with the objective of identifying the behavior pattern of the high
impedance faults. It is also included a discussion and analysis of results and suggestions
related to future works. / Este trabalho focaliza a modelagem das redes de distribuição monofásicas e trifásicas
com retorno por terra, para análise das faltas de alta impedância. A motivação principal está
no fato de não existirem soluções definitivas para essas faltas. Este tipo de falta ocorre quando
um cabo energizado rompe e cai sobre um tipo de superfície, tal como asfalto, areia, árvores,
dentre outros. Essa falta é analisada em uma rede Monofásica com Retorno por Terra MRT
em uma rede trifásica rural.
A rede MRT é deduzida a partir de uma rede trifásica genérica, onde são adicionadas
hipóteses simplificadoras práticas. São realizadas simulações em dois sistemas testes de
distribuição, com o objetivo de identificar o padrão de comportamento das faltas de alta
impedância. É realizada uma discussão e análise de resultados, sugerindo-se trabalhos futuros.
|
Page generated in 0.0476 seconds