Avaliação da aplicação da análise de segunda ordem em pórticos de edifícios correntes em aço / Assessment of the application of second order analysis to current steel building frames

Pires Filho, Carlos Augusto Bonifácio 01 March 2011 (has links)
Made available in DSpace on 2015-03-26T13:28:04Z (GMT). No. of bitstreams: 1 texto completo.pdf: 6612372 bytes, checksum: b13d5987ee6587979e4a1d61f6ce7737 (MD5) Previous issue date: 2011-03-01 / Fundação de Amparo a Pesquisa do Estado de Minas Gerais / This work presents the assessment of the application of second-order analysis to currents steel structures. Aspects related to the structural analysis, structural stability and design, are discussed according to the requirements of ABNT NBR8800:1986 and ABNT NBR8800:2008. The first-order analysis and the effective length approach are compared with the second-order analysis considering the initial imperfections proposed by ABNT NBR8800:2008. The results of the second-order analysis performed with a computer program are compared with the results obtained with the Notional Load Approach (MAES), regarded in the Annex D of ABNT NBR8800:2008. Eight case studies are presented in order to compare the responses of the different types of analysis carried out and to compare the results of the ultimate load-carrying capacity of structural members according to the methodology proposed by ABNT NBR8800:1986 and ABNT NBR8800:2008. It was found out that the results obtained with MAES were very close to those obtained with an approximated second-order analysis (ASO) performed with SAP2000. Moreover, it was noted a close proximity between the results of normal force, shear force and bending moment for the different types of analysis performed (APO, ASO and ASO-MAES), confirming the hypothesis that to "non-sway" frames the influence of second-order effects is not relevant. Regarding the ultimate load-carrying capacity verification of columns, it was found that the ABNT NBR8800:2008 interaction equation led, systematically, to a more economical design. On the other hand, the ABNT NBR8800:1986 approach, using the effective length concept, was always conservative. / Neste trabalho apresenta-se uma avaliação da aplicabilidade da análise de segunda ordem a estruturas de aço correntes. Aspectos relacionados à análise estrutural, à estabilidade estrutural e ao dimensionamento, são discutidos segundo as prescrições da ABNT NBR8800:1986 e da ABNT NBR8800:2008. A análise de primeira ordem e o método do coeficiente de flambagem (K) são avaliados e confrontados com a análise de segunda ordem e a consideração das imperfeições iniciais proposto pela ABNT NBR8800:2008. Os resultados das análises realizadas de acordo com as normas citadas anteriormente, obtidos com auxílio de um programa computacional, são comparados com os resultados obtidos por meio da aplicação do Método de Amplificação dos Esforços Solicitantes (MAES), previsto no Anexo D da ABNT NBR8800:2008. São apresentados oito estudos de caso com o intuito de comparar as respostas dos diferentes tipos de análise e comparar os resultados da verificação da capacidade última de elementos estruturais, segundo a metodologia proposta pela ABNT NBR8800:1986 e pela ABNT NBR8800:2008. Os resultados obtidos por meio do MAES foram muito próximos daqueles obtidos por meio da análise de segunda ordem aproximada (ASO), realizada com auxílio do programa computacional SAP 2000. Notou-se uma grande proximidade entre os resultados de esforços normal, cortante e momento fletor para os diferentes tipos de análise realizados (APO, ASO e ASO-MAES), confirmando a premissa de que em estruturas de pequena deslocabilidade a influência dos efeitos de segunda ordem não é relevante, ou seja, não há um aumento considerável dos esforços internos solicitantes. Com relação às verificações da capacidade última dos pilares, observou-se que a metodologia da ABNT NBR8800:2008 conduziu, sistematicamente, a um dimensionamento mais econômico. Por outro lado, a metodologia prevista na ABNT NBR8800:1986, que utiliza o conceito do comprimento efetivo de flambagem, mostrou-se sempre a favor da segurança.
2

Contribuição ao estudo da estabilidade de edifícios de andares múltiplos em aço / Contribution to the study of stability of steel multi-storey buildings

Camargo, Rafael Eclache Moreira de 20 August 2012 (has links)
Este trabalho apresenta uma análise comparativa de diferentes sistemas estruturais para um edifício de 20 pavimentos. Cada um dos modelos foi dimensionado através dos princípios do método da análise direta, presente na ABNT NBR 8800:2008. O método da amplificação dos esforços solicitantes (MAES) foi usado para se obter de forma simplificada os esforços atuantes nos elementos do edifício considerando os efeitos locais e globais de segunda ordem. A incidência do vento foi simulada de duas formas diferentes. Na primeira, chamada de uniforme, o vento foi aplicado sem excentricidade, gerando apenas o efeito de tombamento nas estruturas. Na segunda hipótese, considerou-se uma excentricidade devida aos efeitos de vizinhança, prescrita pela ABNT NBR 6123:1988, responsável por ocasionar o tombamento e a torção dos edifícios. Todas as análises numéricas foram repetidas fazendo o uso de outro método simplificado de segunda ordem, conhecido como P-Delta. Por meio dos resultados obtidos, constatou-se que a possibilidade de se reduzir a sobrecarga para o dimensionamento de pilares proporciona uma economia de material, mas, por outro lado, tem como consequência o aumento do tempo de análise, pois exige a utilização de diferentes combinações de cálculo para o dimensionamento de vigas e pilares. A estratégia utilizada para simular os efeitos de vizinhança mostrou-se satisfatória, pois permitiu introduzir de maneira fácil e prática a torção ocasionada pela incidência excêntrica do vento. Observou-se também que esses efeitos ocasionaram o aumento dos momentos fletores e dos deslocamentos das estruturas analisadas. Em relação à avaliação dos efeitos de segunda ordem, comprovou-se que, para a classificação da deslocabilidade, a combinação de cálculo crítica é aquela que possui o maior carregamento gravitacional. Entretanto, para o dimensionamento dos elementos, foi constatado que outras hipóteses de cálculo, principalmente aquelas em que o vento é a ação variável principal, podem ser determinantes. Por fim, foi observado que os resultados obtidos pelo método P-Delta ficaram bastante semelhantes àqueles calculados pelo MAES, com desvios desprezíveis. O MAES, por sua vez, mostrou-se bastante trabalhoso, pois exige a modelagem de diferentes tipos de estruturas para a determinação dos esforços. / This work presents a comparative analysis of different structural systems for a 20-storey building. Each model has been designed using the principles of the direct analysis method (DAM), present in the ABNT NBR 8800:2008. The first-order amplification method (FOAM) was used to obtain, in a simplified manner, the forces acting on the building elements, including local and global second-order effects. The incidence of the wind was simulated in two different ways. In the first case, named uniform, the wind was applied without eccentricity, generating only structure overturning. In the second case, it was considered an eccentricity due to vicinity effects, prescribed by the ABNT NBR 6123:1988, responsible for causing twisting and building overturning. All numerical analysis were carried out a simplified second-order method known as P-Delta. From the results obtained it was found that the reduction of live loads in the design of columns provides material economy, but on the other hand, increases analysis time, since it requires different combinations for beams and columns. The strategy used to simulate the vicinity effects was satisfactory, because it allowed, in an easy and practical way, the consideration of the torsion produced by the wind eccentric impact. It was also observed that these effects increased the bending moments and the displacements of the structures. About the second-order effects, it was shown that, for sway or non-sway classification, the critical combination is one with greatest gravitational loading. However, for the design of the elements, it was observed that other loading conditions can be critical, especially those in which the wind is the main live load. Finally, the results obtained by the P-Delta method were very similar to those calculated by the first-order amplification method. The FOAM was, in turn, very laborious, because it requires the modeling of different types of structures for the determination of the forces.
3

Contribuição ao estudo da estabilidade de edifícios de andares múltiplos em aço / Contribution to the study of stability of steel multi-storey buildings

Rafael Eclache Moreira de Camargo 20 August 2012 (has links)
Este trabalho apresenta uma análise comparativa de diferentes sistemas estruturais para um edifício de 20 pavimentos. Cada um dos modelos foi dimensionado através dos princípios do método da análise direta, presente na ABNT NBR 8800:2008. O método da amplificação dos esforços solicitantes (MAES) foi usado para se obter de forma simplificada os esforços atuantes nos elementos do edifício considerando os efeitos locais e globais de segunda ordem. A incidência do vento foi simulada de duas formas diferentes. Na primeira, chamada de uniforme, o vento foi aplicado sem excentricidade, gerando apenas o efeito de tombamento nas estruturas. Na segunda hipótese, considerou-se uma excentricidade devida aos efeitos de vizinhança, prescrita pela ABNT NBR 6123:1988, responsável por ocasionar o tombamento e a torção dos edifícios. Todas as análises numéricas foram repetidas fazendo o uso de outro método simplificado de segunda ordem, conhecido como P-Delta. Por meio dos resultados obtidos, constatou-se que a possibilidade de se reduzir a sobrecarga para o dimensionamento de pilares proporciona uma economia de material, mas, por outro lado, tem como consequência o aumento do tempo de análise, pois exige a utilização de diferentes combinações de cálculo para o dimensionamento de vigas e pilares. A estratégia utilizada para simular os efeitos de vizinhança mostrou-se satisfatória, pois permitiu introduzir de maneira fácil e prática a torção ocasionada pela incidência excêntrica do vento. Observou-se também que esses efeitos ocasionaram o aumento dos momentos fletores e dos deslocamentos das estruturas analisadas. Em relação à avaliação dos efeitos de segunda ordem, comprovou-se que, para a classificação da deslocabilidade, a combinação de cálculo crítica é aquela que possui o maior carregamento gravitacional. Entretanto, para o dimensionamento dos elementos, foi constatado que outras hipóteses de cálculo, principalmente aquelas em que o vento é a ação variável principal, podem ser determinantes. Por fim, foi observado que os resultados obtidos pelo método P-Delta ficaram bastante semelhantes àqueles calculados pelo MAES, com desvios desprezíveis. O MAES, por sua vez, mostrou-se bastante trabalhoso, pois exige a modelagem de diferentes tipos de estruturas para a determinação dos esforços. / This work presents a comparative analysis of different structural systems for a 20-storey building. Each model has been designed using the principles of the direct analysis method (DAM), present in the ABNT NBR 8800:2008. The first-order amplification method (FOAM) was used to obtain, in a simplified manner, the forces acting on the building elements, including local and global second-order effects. The incidence of the wind was simulated in two different ways. In the first case, named uniform, the wind was applied without eccentricity, generating only structure overturning. In the second case, it was considered an eccentricity due to vicinity effects, prescribed by the ABNT NBR 6123:1988, responsible for causing twisting and building overturning. All numerical analysis were carried out a simplified second-order method known as P-Delta. From the results obtained it was found that the reduction of live loads in the design of columns provides material economy, but on the other hand, increases analysis time, since it requires different combinations for beams and columns. The strategy used to simulate the vicinity effects was satisfactory, because it allowed, in an easy and practical way, the consideration of the torsion produced by the wind eccentric impact. It was also observed that these effects increased the bending moments and the displacements of the structures. About the second-order effects, it was shown that, for sway or non-sway classification, the critical combination is one with greatest gravitational loading. However, for the design of the elements, it was observed that other loading conditions can be critical, especially those in which the wind is the main live load. Finally, the results obtained by the P-Delta method were very similar to those calculated by the first-order amplification method. The FOAM was, in turn, very laborious, because it requires the modeling of different types of structures for the determination of the forces.