• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Viabilidade de pós-tratamento aeróbio de efluentes de reatores UASB visando reúso.

PAIVA, Laio Ariel Leite de. 13 September 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-09-13T17:38:25Z No. of bitstreams: 1 LAIO ARIEL LEITE DE PAIVA – DISSERTAÇÃO (PPGECA) 2016.pdf: 2279883 bytes, checksum: ddf555f3b9251dc01dc78d5b5fe5df71 (MD5) / Made available in DSpace on 2018-09-13T17:38:25Z (GMT). No. of bitstreams: 1 LAIO ARIEL LEITE DE PAIVA – DISSERTAÇÃO (PPGECA) 2016.pdf: 2279883 bytes, checksum: ddf555f3b9251dc01dc78d5b5fe5df71 (MD5) Previous issue date: 2016-02-29 / Capes / Sistemas anaeróbios modernos de tratamento de esgoto doméstico, embora bastante eficientes na remoção de matéria orgânica e sólidos em suspensão, não produzem um efluente com qualidade compatível com os padrões legais para descarga em corpos d’água receptores. Por essa razão esses sistemas têm que ser associados a unidades de pós-tratamento. Este trabalho trata de uma investigação experimental sobre a viabilidade de se aplicar o sistema de lodo ativado como uma alternativa do pós-tratamento, especificamente para o caso em que se prevê o efluente final para reúso. Na investigação experimental se usou um reator de bateladas sequenciais (RBS) em escala de bancada como unidade de pós-tratamento. Os resultados experimentais mostraram que a qualidade de efluente do sistema RBS de pós-tratamento em relação a matéria orgânica é muito boa. Na otimização do reator RBS se desenvolveu um modelo que permite estabelecer o tempo de permanência mínimo para o pós-tratamento em função de dois parâmetros básicos: a constante de utilização de material orgânico biodegradável pelas bactérias heterotróficas do lodo gerado no sistema de pós-tratamento e a sedimentabilidade deste lodo. A constante de utilização de material orgânico foi determinada por testes respirométrico. O lodo gerado no sistema de pós-tratamento surpreendentemente mostrou ter uma sedimentabilidade bem superior àquela normalmente encontrada em sistemas de lodo ativado tratando esgoto bruto, o que constitui um argumento sólido para a aplicação do sistema RBS na prática de pós tratamento do efluente do reator UASB. / Modern anaerobic systems for domestic sewage treatment, although very effective in removing organic matter and solid suspended, do not produce an effluent quality compatible with the legal standards for discharge into water bodies’ receivers. Therefore, such systems have to be associated with post treatment units. This paper deals with an experimental investigation into the feasibility of applying the activated sludge system as an alternative post-treatment, specifically for the case where intended use of the treated wastewater is reuse. In the experimental investigation research, a sequencing batch reactor (RBS) at bench scale was use as post treatment. The experimental results showed that the effluent quality of the RBS post treatment system in relation to organic matter was very good. An algorithm to optimize the RBS reactor was developed and allowed establishing the minimum residence time for the post-treatment in terms of two basic parameters: the utilization constant of biodegradable organic material by heterotrophic bacteria in the post-treatment system and the sludge settleability. The organic material using respirometric constant was determined from the oxygen uptake rate during the post treatment. The sludge from the post-treatment system surprisingly showed a much better settleability than what normally found in activated sludge systems treating raw sewage, which provides a strong argument for the application of the RBS system in practice post-treatment of the UASB reactor effluent.
2

Estudo do desempenho de reator anaeróbio-aeróbio de escoamento ascendente no tratamento de esgoto sanitário com espuma de poliuretano como suporte de imobilização da biomassa / Study on the performance of an anaerobic-aerobic upflow reactor in the treatment of wastewater using polyurethane foam as a support for biomass immobilization

Abreu, Sergio Brasil 27 June 2003 (has links)
O projeto consistiu na concepção e avaliação do desempenho de um sistema anaeróbio-aeróbio para tratamento de esgoto sanitário. O leito do reator foi dividido em quatro compartimentos de igual volume. Foi usada espuma de poliuretano para imobilização da biomassa e, para facilitar a partida do reator, esse material suporte foi previamente inoculado. O projeto teve três fases distintas: na primeira etapa, foi observada a importância da concentração de biomassa anaeróbia no desempenho de reator anaeróbio a princípio operado com metade do leito reacional com espuma e, a seguir, com o leito todo preenchido com espuma. Na segunda etapa, foram testados diferentes tempos de detenção hidráulica no reator que operou apenas em condições anaeróbias. Na última etapa foi operado o reator combinado anaeróbio-aeróbio. Ficou constatada a importância da concentração de microrganismos no desempenho do reator anaeróbio, pois com o aumento da quantidade de espuma, o reator atingiu resultados melhores e maior estabilidade operacional. Foi comprovada a influência do tempo de detenção hidráulica (TDH) no desempenho do reator. Tempos de detenção muito altos acarretam problemas de transferência de massa líquido-sólido, e baixos TDH dificultam adequada ação dos microrganismos. O melhor resultado para o reator em operação exclusivamente anaeróbia foi para o TDH de 10 horas, no qual se conseguiu reduzir a DQO de amostra bruta de 389 +/- 70 mg/L para 137 +/- 16 mg/L, em média. Para o reator operado anaeróbio-aeróbio a DQO de amostra bruta decresceu de 259 +/- 69 mg/L para 93 +/- 31 mg/L, em média. A comparação de todos os resultados obtidos, evidenciou a importância do pós-tratamento aeróbio na remoção de parcela de matéria orgânica não removida em tratamento unicamente anaeróbio. / The project consisted in the design and performance evaluation of an anaerobic-aerobic system for wastewater treatment. Polyurethane foam was used for biomass immobilization and, to smooth the reactor start-up, this supporting material was previously inoculated. The project was divided in three distinct phases. In the first one, the importance of the anaerobic biomass concentration was observed in the performance of the anaerobic reactor in a way to operate the reactor primarily with half of the reaction bed filled with foam and subsequently operate it with the bed completely filled with foam. In the second phase, different times of hydraulic retention were tested with the reactor operating exclusively in anerobic conditions. In the third and last phase, an anaerobic-aerobic combined reactor was operated. It was possible to confirm the importance of microorganism concentration in the performance of the anaerobic reactor, since the increase in the amount of foam allowed the reactor to reach better results and greater operational stability. The influence of the hydraulic retention time in the reactor performance was also proved. Very high retention times cause problems in the liquid-solid mass transference, while low retention times do not allow an adequate action of microorganisms. The best result for the reactor with an exclusive anaerobic operation was the 10 hour retention time, when it was possible to reduce the COD of a 389 +/- 70 mg/L gross sample to a 137 +/- 16 mg/L in average. On the other hand, for the anaerobic-aerobic operating reactor, the COD of a gross sample dropped from 259 +/- 69 mg/ L to 93 +/- 31 mg/L in average. Finally, comparing all the obtained results, it was possible to verify the importance of the anaerobic post treatment in the removal of a part of the organic matter not removed in an exclusively anaerobic treatment.
3

Reator anaeróbio-aeróbio de leito fixo, com recirculação da fase líquida, aplicado ao tratamento de esgoto sanitário / Anaerobic-aerobic fixed bed reactor, with recycle of the liquid phase, applied to the treatment of domestic sewage

Oliveira Netto, Antonio Pedro de 28 March 2007 (has links)
Este trabalho avaliou o desempenho de um sistema que combina os processos anaeróbio e aeróbio, para tratamento de esgoto sanitário, operado de modo contínuo sem e com recirculação da fase líquida. A combinação dos processos anaeróbio e aeróbio tem como objetivo aproveitar as vantagens de cada um, minimizando seus aspectos negativos. Foi utilizado um reator, em escala de bancada, de leito fixo e fluxo contínuo de escoamento ascendente com argila expandida e espuma de poliuretano como suportes de imobilização da biomassa. O desempenho do sistema foi avaliado em três diferentes tempos de detenção hidráulica (TDH), 6, 8 e 10 horas, na fase anaeróbia, nos quais os melhores valores de remoção de matéria orgânica chegaram a 80%, com valores de DQO efluente abaixo de 150 mg/L. Com a inserção da fase aeróbia ao sistema (TDH de aproximadamente 11 horas, sendo 8 horas para a fase anaeróbia e 3 horas para a fase aeróbia), a eficiência subiu para mais de 90% com DQO efluente abaixo dos 50 mg/L. A nitrificação ocorreu perto do 15° dia operacional do sistema combinado e estava praticamente estável ao fim dessa etapa operacional. Após o 20º dia de operação as concentrações de nitrito mantiveram-se sempre baixas, o que indica equilíbrio da nitrificação. Foram obtidos ganhos quando feita recirculação do efluente tratado, principalmente em relação à remoção de matéria orgânica (95%) e remoção de nitrogênio total que foi de 75% para razão de recirculação de 1,5. O reator avaliado apresentou estabilidade operacional, alta remoção de matéria orgânica e nitrogênio sem a necessidade de adição de fonte exógena de carbono e de suplementação de alcalinidade. / This work evaluated the performance of a system that combines anaerobic and aerobic processes, for treatment of domestic sewage. The bench-scale fixed-film reactor was operated in a continuous way without and with recycle of the liquid phase. Expanded clay and polyurethane foam were used as supports for immobilization of the biomass. Initially, the system was operated under anaerobic condition and its performance was evaluated for three different hydraulic retention times (HRT), 6, 8 and 10 h. In this phase, COD removal efficiency of 80% was reached for HRT of 10 h, with effluent COD below 150 mgCOD/L. The combined anaerobic-aerobic operation (HRT of approximately 11 h, being 8 h for the anaerobic phase and 3 h for the aerobic phase) favored the organic matter removal that reached 90%, with effluent COD below 50 mgCOD/L. The operation with liquid recycle provided the best results with COD removal of 95% and total nitrogen removal of 75% under recycle ratio of 1.5. The anaerobic-aerobic fixed bed reactor, with recycle of the liquid phase, proved to be an excellent alternative for domestic sewage treatment, mainly when organic matter and nitrogen removals are required. The concomitant C and N removal without addition of exogenous source electron donor and with no additional alkalinity supplementation was the main advantage of this reactor over the conventional reactors applied for this purpose.
4

Reator anaeróbio-aeróbio de leito fixo em escala piloto, com recirculação da fase líquida, aplicado ao tratamento de esgoto sanitário / Anaerobic-aerobic pilot-scale fixed-bed reactor, with recycle of the liquid phase, applied to the treatment of domestic sewage

Oliveira Netto, Antonio Pedro de 29 April 2011 (has links)
Este trabalho fundamentou-se na concepção, desenvolvimento tecnológico, ampliação de escala e avaliação do comportamento de sistema combinado anaeróbio-aeróbio de leito fixo e fluxo ascendente, com recirculação da fase líquida, para tratamento de esgoto sanitário. O reator, em escala piloto, foi construído em formato cilíndrico e confeccionado em fibra de vidro com volume total de aproximadamente 2,5 \'M POT.3\', com intuito de desenvolver um sistema capaz de operar como única unidade de tratamento para remoção de matéria orgânica e nitrogênio, reduzindo a geração de lodo e o consumo de energia pela combinação dos processos anaeróbio e aeróbio, possibilitando o aproveitamento das vantagens de cada um e minimizando seus aspectos negativos. Os melhores resultados operacionais foram encontrados para a etapa com tempo de detenção hidráulica total (TDH) de 12 horas e razão de recirculação (r) igual a 3,0, apresentando eficiências médias de remoção de DQO, \'N\'-NTK e SST de 92 ± 3%; 68 ± 11% e 75 ± 7%, respectivamente, com valores médios efluentes de 54 ± 22 mgDQO/L, 14 ± 10 mg \'N\'-NTK/L e 70 ± 42 mgSST/L. Os valores médios de carga orgânica volumétrica (COV) e carga volumétrica de nitrogênio (CVN) removidas foram de 1,08 ± 0,04 kgDQO/\'M POT.3\'.dia e 0,06 ± 0,02 kgNTK/\'M POT.3\'.dia para esta etapa. A estabilidade operacional durante a etapa com TDH de 12 h, a alta remoção de matéria orgânica e nitrogênio, sem a necessidade de adição de fonte exógena de carbono, para promover o processo de desnitrificação, e de suplementação de alcalinidade consumida durante a nitrificação, e a reduzida necessidade de manutenção devido à tecnologia de fabricação adotada, comprovam a viabilidade técnica de utilização do reator combinado de leito fixo como unidade compacta para pequenas comunidades ou vazões afluentes, para tratamento de esgoto sanitário. / This work was based on design, technology development, scale up and performance evaluation of an up-flow combined anaerobic-aerobic fixed bed system, with recycle of the liquid phase, for treatment of domestic sewage. The pilot scale reactor was built in a fiberglass cylindrical shape with a total volume of approximately 2.5 \'M POT.3\', aiming at the development of a system capable of operate as a single treatment unit for organic matter and nitrogen removal, with low sludge production and energy consumption by the advantages of combination of anaerobic and aerobic processes. The improved operating results were found for the condition with overall hydraulic retention time (HRT) of 12 hours and recycle ratio (r) equal to 3.0, with average removal efficiencies of COD, TKN and TSS of 92 ± 3%, 68 ± 11% and 75 ± 7%, respectively, with average effluent values of 54 ± 22 mgCOD/L, 14 ± 10 mgTKN/L and 70 ± 42 mgTSS/L. The average values of removed organic loading rate (OLR) and nitrogen volumetric loading (NVL) reached 1.06 ± 0.04 kgCOD/\'M POT.3.d and 0.06 ± 0.02 kgTKN/\'\'M POT.3\'.d for this phase. The operational stability during the stage with HRT of 12 h, the high organic matter and nitrogen removal, without addition of exogenous carbon source (electron donor) to promote the denitrification process, with no supplementation of alkalinity consumed during nitrification, and the reduced maintenance due to manufacturing technology adopted, proved the technical feasibility of the combined fixed-bed reactor as a compact unit for small communities or low inflow rates, for treatment of domestic sewage.
5

Reator anaeróbio-aeróbio de leito fixo, com recirculação da fase líquida, aplicado ao tratamento de esgoto sanitário / Anaerobic-aerobic fixed bed reactor, with recycle of the liquid phase, applied to the treatment of domestic sewage

Antonio Pedro de Oliveira Netto 28 March 2007 (has links)
Este trabalho avaliou o desempenho de um sistema que combina os processos anaeróbio e aeróbio, para tratamento de esgoto sanitário, operado de modo contínuo sem e com recirculação da fase líquida. A combinação dos processos anaeróbio e aeróbio tem como objetivo aproveitar as vantagens de cada um, minimizando seus aspectos negativos. Foi utilizado um reator, em escala de bancada, de leito fixo e fluxo contínuo de escoamento ascendente com argila expandida e espuma de poliuretano como suportes de imobilização da biomassa. O desempenho do sistema foi avaliado em três diferentes tempos de detenção hidráulica (TDH), 6, 8 e 10 horas, na fase anaeróbia, nos quais os melhores valores de remoção de matéria orgânica chegaram a 80%, com valores de DQO efluente abaixo de 150 mg/L. Com a inserção da fase aeróbia ao sistema (TDH de aproximadamente 11 horas, sendo 8 horas para a fase anaeróbia e 3 horas para a fase aeróbia), a eficiência subiu para mais de 90% com DQO efluente abaixo dos 50 mg/L. A nitrificação ocorreu perto do 15° dia operacional do sistema combinado e estava praticamente estável ao fim dessa etapa operacional. Após o 20º dia de operação as concentrações de nitrito mantiveram-se sempre baixas, o que indica equilíbrio da nitrificação. Foram obtidos ganhos quando feita recirculação do efluente tratado, principalmente em relação à remoção de matéria orgânica (95%) e remoção de nitrogênio total que foi de 75% para razão de recirculação de 1,5. O reator avaliado apresentou estabilidade operacional, alta remoção de matéria orgânica e nitrogênio sem a necessidade de adição de fonte exógena de carbono e de suplementação de alcalinidade. / This work evaluated the performance of a system that combines anaerobic and aerobic processes, for treatment of domestic sewage. The bench-scale fixed-film reactor was operated in a continuous way without and with recycle of the liquid phase. Expanded clay and polyurethane foam were used as supports for immobilization of the biomass. Initially, the system was operated under anaerobic condition and its performance was evaluated for three different hydraulic retention times (HRT), 6, 8 and 10 h. In this phase, COD removal efficiency of 80% was reached for HRT of 10 h, with effluent COD below 150 mgCOD/L. The combined anaerobic-aerobic operation (HRT of approximately 11 h, being 8 h for the anaerobic phase and 3 h for the aerobic phase) favored the organic matter removal that reached 90%, with effluent COD below 50 mgCOD/L. The operation with liquid recycle provided the best results with COD removal of 95% and total nitrogen removal of 75% under recycle ratio of 1.5. The anaerobic-aerobic fixed bed reactor, with recycle of the liquid phase, proved to be an excellent alternative for domestic sewage treatment, mainly when organic matter and nitrogen removals are required. The concomitant C and N removal without addition of exogenous source electron donor and with no additional alkalinity supplementation was the main advantage of this reactor over the conventional reactors applied for this purpose.
6

Estudo do desempenho de reator anaeróbio-aeróbio de escoamento ascendente no tratamento de esgoto sanitário com espuma de poliuretano como suporte de imobilização da biomassa / Study on the performance of an anaerobic-aerobic upflow reactor in the treatment of wastewater using polyurethane foam as a support for biomass immobilization

Sergio Brasil Abreu 27 June 2003 (has links)
O projeto consistiu na concepção e avaliação do desempenho de um sistema anaeróbio-aeróbio para tratamento de esgoto sanitário. O leito do reator foi dividido em quatro compartimentos de igual volume. Foi usada espuma de poliuretano para imobilização da biomassa e, para facilitar a partida do reator, esse material suporte foi previamente inoculado. O projeto teve três fases distintas: na primeira etapa, foi observada a importância da concentração de biomassa anaeróbia no desempenho de reator anaeróbio a princípio operado com metade do leito reacional com espuma e, a seguir, com o leito todo preenchido com espuma. Na segunda etapa, foram testados diferentes tempos de detenção hidráulica no reator que operou apenas em condições anaeróbias. Na última etapa foi operado o reator combinado anaeróbio-aeróbio. Ficou constatada a importância da concentração de microrganismos no desempenho do reator anaeróbio, pois com o aumento da quantidade de espuma, o reator atingiu resultados melhores e maior estabilidade operacional. Foi comprovada a influência do tempo de detenção hidráulica (TDH) no desempenho do reator. Tempos de detenção muito altos acarretam problemas de transferência de massa líquido-sólido, e baixos TDH dificultam adequada ação dos microrganismos. O melhor resultado para o reator em operação exclusivamente anaeróbia foi para o TDH de 10 horas, no qual se conseguiu reduzir a DQO de amostra bruta de 389 +/- 70 mg/L para 137 +/- 16 mg/L, em média. Para o reator operado anaeróbio-aeróbio a DQO de amostra bruta decresceu de 259 +/- 69 mg/L para 93 +/- 31 mg/L, em média. A comparação de todos os resultados obtidos, evidenciou a importância do pós-tratamento aeróbio na remoção de parcela de matéria orgânica não removida em tratamento unicamente anaeróbio. / The project consisted in the design and performance evaluation of an anaerobic-aerobic system for wastewater treatment. Polyurethane foam was used for biomass immobilization and, to smooth the reactor start-up, this supporting material was previously inoculated. The project was divided in three distinct phases. In the first one, the importance of the anaerobic biomass concentration was observed in the performance of the anaerobic reactor in a way to operate the reactor primarily with half of the reaction bed filled with foam and subsequently operate it with the bed completely filled with foam. In the second phase, different times of hydraulic retention were tested with the reactor operating exclusively in anerobic conditions. In the third and last phase, an anaerobic-aerobic combined reactor was operated. It was possible to confirm the importance of microorganism concentration in the performance of the anaerobic reactor, since the increase in the amount of foam allowed the reactor to reach better results and greater operational stability. The influence of the hydraulic retention time in the reactor performance was also proved. Very high retention times cause problems in the liquid-solid mass transference, while low retention times do not allow an adequate action of microorganisms. The best result for the reactor with an exclusive anaerobic operation was the 10 hour retention time, when it was possible to reduce the COD of a 389 +/- 70 mg/L gross sample to a 137 +/- 16 mg/L in average. On the other hand, for the anaerobic-aerobic operating reactor, the COD of a gross sample dropped from 259 +/- 69 mg/ L to 93 +/- 31 mg/L in average. Finally, comparing all the obtained results, it was possible to verify the importance of the anaerobic post treatment in the removal of a part of the organic matter not removed in an exclusively anaerobic treatment.
7

Reator anaeróbio-aeróbio de leito fixo em escala piloto, com recirculação da fase líquida, aplicado ao tratamento de esgoto sanitário / Anaerobic-aerobic pilot-scale fixed-bed reactor, with recycle of the liquid phase, applied to the treatment of domestic sewage

Antonio Pedro de Oliveira Netto 29 April 2011 (has links)
Este trabalho fundamentou-se na concepção, desenvolvimento tecnológico, ampliação de escala e avaliação do comportamento de sistema combinado anaeróbio-aeróbio de leito fixo e fluxo ascendente, com recirculação da fase líquida, para tratamento de esgoto sanitário. O reator, em escala piloto, foi construído em formato cilíndrico e confeccionado em fibra de vidro com volume total de aproximadamente 2,5 \'M POT.3\', com intuito de desenvolver um sistema capaz de operar como única unidade de tratamento para remoção de matéria orgânica e nitrogênio, reduzindo a geração de lodo e o consumo de energia pela combinação dos processos anaeróbio e aeróbio, possibilitando o aproveitamento das vantagens de cada um e minimizando seus aspectos negativos. Os melhores resultados operacionais foram encontrados para a etapa com tempo de detenção hidráulica total (TDH) de 12 horas e razão de recirculação (r) igual a 3,0, apresentando eficiências médias de remoção de DQO, \'N\'-NTK e SST de 92 ± 3%; 68 ± 11% e 75 ± 7%, respectivamente, com valores médios efluentes de 54 ± 22 mgDQO/L, 14 ± 10 mg \'N\'-NTK/L e 70 ± 42 mgSST/L. Os valores médios de carga orgânica volumétrica (COV) e carga volumétrica de nitrogênio (CVN) removidas foram de 1,08 ± 0,04 kgDQO/\'M POT.3\'.dia e 0,06 ± 0,02 kgNTK/\'M POT.3\'.dia para esta etapa. A estabilidade operacional durante a etapa com TDH de 12 h, a alta remoção de matéria orgânica e nitrogênio, sem a necessidade de adição de fonte exógena de carbono, para promover o processo de desnitrificação, e de suplementação de alcalinidade consumida durante a nitrificação, e a reduzida necessidade de manutenção devido à tecnologia de fabricação adotada, comprovam a viabilidade técnica de utilização do reator combinado de leito fixo como unidade compacta para pequenas comunidades ou vazões afluentes, para tratamento de esgoto sanitário. / This work was based on design, technology development, scale up and performance evaluation of an up-flow combined anaerobic-aerobic fixed bed system, with recycle of the liquid phase, for treatment of domestic sewage. The pilot scale reactor was built in a fiberglass cylindrical shape with a total volume of approximately 2.5 \'M POT.3\', aiming at the development of a system capable of operate as a single treatment unit for organic matter and nitrogen removal, with low sludge production and energy consumption by the advantages of combination of anaerobic and aerobic processes. The improved operating results were found for the condition with overall hydraulic retention time (HRT) of 12 hours and recycle ratio (r) equal to 3.0, with average removal efficiencies of COD, TKN and TSS of 92 ± 3%, 68 ± 11% and 75 ± 7%, respectively, with average effluent values of 54 ± 22 mgCOD/L, 14 ± 10 mgTKN/L and 70 ± 42 mgTSS/L. The average values of removed organic loading rate (OLR) and nitrogen volumetric loading (NVL) reached 1.06 ± 0.04 kgCOD/\'M POT.3.d and 0.06 ± 0.02 kgTKN/\'\'M POT.3\'.d for this phase. The operational stability during the stage with HRT of 12 h, the high organic matter and nitrogen removal, without addition of exogenous carbon source (electron donor) to promote the denitrification process, with no supplementation of alkalinity consumed during nitrification, and the reduced maintenance due to manufacturing technology adopted, proved the technical feasibility of the combined fixed-bed reactor as a compact unit for small communities or low inflow rates, for treatment of domestic sewage.

Page generated in 0.0615 seconds