• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Técnica de modificação intraoperatória de endoprotese de ePTFE, para tratamento de aneurismas de aorta abdominal sem colo adequado

Oliveira, Gustavo Paludetto 28 February 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências Médicas, Programa de Pós-Graduação em Ciências Médicas, 2014. / Submitted by Larissa Stefane Vieira Rodrigues (larissarodrigues@bce.unb.br) on 2014-11-18T15:18:55Z No. of bitstreams: 1 2014_GustavoPaludettoOliveira.pdf: 5627138 bytes, checksum: 182a458d77794e8be7775bf64f7b03e5 (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2014-11-24T15:52:03Z (GMT) No. of bitstreams: 1 2014_GustavoPaludettoOliveira.pdf: 5627138 bytes, checksum: 182a458d77794e8be7775bf64f7b03e5 (MD5) / Made available in DSpace on 2014-11-24T15:52:03Z (GMT). No. of bitstreams: 1 2014_GustavoPaludettoOliveira.pdf: 5627138 bytes, checksum: 182a458d77794e8be7775bf64f7b03e5 (MD5) / INTRODUÇÃO: Resultados em curto prazo demonstram que os aneurismas abdominais sem colo adequado (<15 mm), também podem ser tratados com sucesso utilizando dispositivos configurados para preservação das artérias viscerais através de “scallops”, fenestrações e ramos. Desenvolvemos uma técnica original de fenestração usando a endoprótese Gore Excluder C3® (W.L. Gore & Ass., USA),para o tratamento de aneurismas sem colo proximal adequado usando fenestrações, garantindo uma área de vedação mínima de 15 milímetros e também para a preservação do fluxo nas artérias viscerais. OBJETIVO: O objetivo dessa técnica é de oferecer uma alternativa eficiente, rápida e de fácil execução para o tratamento endovascular de pacientes com aneurismas de aorta abdominal justa e pararrenais ,sem colo adequado para implante de EP convencionais, em casos de emergência médica e/ou impossibilidade de cirurgica aberta, usando uma endoprótese de ePTFE fenestrada. MÉTODO: Um dispositivo de ePTFE reposicionável Gore Excluder C3® (W.L. Gore & Ass., USA) foi manualmente fenestrado usando material cirúrgico tipo "punch de aorta",sendo suturados fios-guia na borda para obter marcadores radiopacos e para reforçar as fenestrações. que foram posteriormente pré-canuladas com fios-guia 0018". O dispositivo foi “reencapado” usando segmento de um introdutor tipo Dry-seal® (W.L. Gore & Ass., USA) . O dispositivo foi introduzido “in vitro” em um modelo de vidro que imita a anatomia de uma aorta com aneurisma. Manobras para abrir, fechar, girar até encontrar a melhor posição para liberação da endoprótese foram feitas. Através das fenestras, stents grafts foram colocados para as artérias viscerais. RESULTADOS: Foi possível modificar o dispositivo reposicionável Gore Excluder C3 ® sem danificar a estrutura metálica e cobertura de ePTFE preservando sua funcionalidade. O tempo de modificação e de “re-encapamento” foi menor do que uma hora. Não houve vazamentos ou lacunas entre as fenestras e o stents grafts. CONCLUSÃO: A técnica proposta foi eficaz , rápida e não complexa para excluir aneurismas de aorta abdominal sem colo adequado podendo ser utilizada como uma alternativa promissora no tratamento destas lesões. __________________________________________________________________________ ABSTRACT / INTRODUCTION: Short-term results demonstrate that abdominal aneurysms without proper neck (<15 mm), can also be successfully treated with devices configured for preservation of visceral arteries through "scallops", fenestrations and branches. We developed an original technique of endoprosthesis fenestration using the Gore Excluder ® C3 (WL Gore & Ass, USA) device, for the treatment of aneurysms without adequate proximal neck using fenestrations ensuring a minimum sealing area of 15 mm and also preserving the flow in the visceral arteries. OBJECTIVE: The objective of this technique is to provide an efficient, rapid and easy endovascular treatment of patients with abdominal aortic aneurysms without proper neck to implant conventional EP, in cases of medical emergency and / or impossibility of open surgery using a fenestrated endoprosthesis of ePTFE. METHOD: A Gore Excluder ® C3 (WL Gore & Ass, USA) ePTFE device was repositioned manually using fenestrated surgical equipment type "punch aorta", being sutured guidewires on the edge for radiopaque markers and strengthen fenestrations, which were afterwards pre-cannulated with guidewires 0018. The device was re-sheathed using a segment of an introducer ® Dry-seal (specify the company.) It was introduced" in vitro "in an artificial model of aorta (specify ). Maneuvers to open, close and rotate until finding the best position for releasing the endoprosthesis were made. Through fenestrae, stent grafts were placed to the visceral arteries.. RESULTS: It was possible to modify the repositionable device Gore Excluder ® C3 without damaging the metal structure and coverage of ePTFE preserving its functionality. The modification time and "resheeting" was less than one hour. There were no leaks or gaps between fenestrae grafts and stents. CONCLUSION: The proposed technique was effective, fast and not complex to exclude abdominal aortic aneurysms without adequate neck and might a promising alternative for treating such lesions.
2

Análise dos aneurismas de aorta abdominal tratados com endoprótese fenestrada

Oliveira, Gustavo Paludetto 02 March 2018 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Medicina, Programa de Pós-Graduação em Ciências Médicas, 2018. / Submitted by Fabiana Santos (fabianacamargo@bce.unb.br) on 2018-08-17T21:42:56Z No. of bitstreams: 1 2018_GustavoPaludettoOliveira.pdf: 12493694 bytes, checksum: 6b41edf3a6a23dd88b25d1ab7952d147 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-08-21T17:52:25Z (GMT) No. of bitstreams: 1 2018_GustavoPaludettoOliveira.pdf: 12493694 bytes, checksum: 6b41edf3a6a23dd88b25d1ab7952d147 (MD5) / Made available in DSpace on 2018-08-21T17:52:25Z (GMT). No. of bitstreams: 1 2018_GustavoPaludettoOliveira.pdf: 12493694 bytes, checksum: 6b41edf3a6a23dd88b25d1ab7952d147 (MD5) Previous issue date: 2018-08-17 / Objetivo: O estudo relata os resultados de um centro único para avaliar a eficácia da Endoprótese (EP) Gore Excluder C3® (WL Gore, Flagstaff, AZ) modificada pelo cirurgião para o tratamento de aneurismas de aorta abdominal (AAA) justarrenais sintomáticos. Métodos: vinte e oito pacientes foram tratados e acompanhados de 2011 a 2013. O seguimento foi calculado por tomografia em 1, 6, 12 e 18 meses. O objetivo primário foi avaliar a ausência de Endoleak (EL) de tipo I e III. Os objetivos secundários foram a avaliação da patência dos stents, o diâmetro dos aneurismas, migração da EP e necessidade de intervenções secundarias. Resultados: houve 21 homens e 7 mulheres, com idade média de 71,1 anos de idade. O diâmetro médio do aneurisma foi de 61,8mm. Vinte e cinco pacientes não apresentaram EL I e III. Um total de 52 artérias viscerais foram envolvidas em fenestras: 09 pacientes necessitaram de 01 fenestras em uma artéria renal (AR), 14 pacientes de fenestras ambas as artérias renais e 05 pacientes foram tratados com 03 fenestras, para ambas artérias renais e Artéria Mesentérica Superior (SMA). Três pacientes (10,7%) tiveram migração da EP maior que 5mm. Houve 02 oclusões AR e 01 de SMA. Dois pacientes (7,1%) necessitaram de intervenções secundárias para tratamento de oclusão da artéria renal e EL de tipo I ou III. O diâmetro médio de AAA após 18 meses foi de 53,9mm e houve diminuição maior que 5 mm em 17 (60,7%) dos 28 pacientes. A taxa de pacientes livre de intervenções secundárias foi de 92,9%. Não ocorreram mortes relacionadas ao procedimento. Conclusão: Este estudo retrospectivo demonstrou que o tratamento endovascular de AAA justa/pararrenais com a EP Gore Excluder C3® modificada pelo cirurgião foi efetivo e pode ser uma opção para tratar pacientes selecionados em casos de emergência. / Objective: This study reports the results of a single center trial to evaluate the effectiveness of the Surgeon Modified Gore Excluder C3® (WL Gore, Flagstaff, AZ) for treatment of symptomatic juxtarenal abdominal aortic aneurysms (AAAs). Methods: Twenty-eight patients were treated from 2011 to 2013. Follow-up was computed by tomography imaging at 1, 6, 12 and 18 months. Primary end point included absence of type I and III Endoleak (EL). Secondary end points were patency of stents, change in aneurysm diameter, migration and surveillance freedom from re-interventions. Results: There were 21 male and 7 female patients with a mean age of 71,1 years old. Mean aneurysm diameter was 61,8mm. Twenty-five patients had no EL I and III. A total of 52 visceral arteries required fenestrations incorporations: 09 patients required 01 fenestration to one renal artery (RA), 14 patients had 02 both RA fenestrations and 05 patients had 03 fenestrations to both RA and Superior Mesenteric Artery (SMA). Three patients (10,7%) had migration >5mm. There were 02 RA and 01 SMA occlusions. Two patients (7,1%) required secondary interventions for renal artery occlusion and type I or III EL. Mean AAA diameter after 18 months was 53,9mm and there was a greater than 5 mm decrease in 17 (60,7%) out of 28 patients. Freedom from secondary interventions was 92,9%. No deaths occurred. Conclusion: This retrospective study demonstrated that endovascular repair of juxtarenal AAAs with the Modified Gore Excluder C3® was effective and can be an option to treat selected patients in emergency cases.

Page generated in 0.0649 seconds