• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 77
  • 5
  • 1
  • 1
  • Tagged with
  • 84
  • 84
  • 44
  • 32
  • 23
  • 23
  • 14
  • 13
  • 12
  • 11
  • 10
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Lesões da aorta abdominal : contribuição esfigmomanométrica para o seu diagnóstico

Pestana, Gaspar Augusto de Melo January 1924 (has links)
No description available.
2

Um caso de aneurisma da aorta abdominal

Lemos, Benjamim de Meneses Antunes January 1921 (has links)
No description available.
3

Alterações do padrão fluxo sanguíneo após tratamento endovascular do aneurisma sacular da aorta com triplo stent : modelo em suínos

Oliveira, Jahir Richard de January 2012 (has links)
Resumo não disponível
4

Endovascular repair of abdominal aortic aneurysms aspects on a novel technique /

Malina, Martin. January 1998 (has links)
Thesis (doctoral)--Lund University, 1998. / Added t.p. with thesis statement inserted.
5

Endovascular repair of abdominal aortic aneurysms aspects on a novel technique /

Malina, Martin. January 1998 (has links)
Thesis (doctoral)--Lund University, 1998. / Added t.p. with thesis statement inserted.
6

Tratamento endovascular do aneurisma da aorta abdominal

Rampinelli, Amandio January 2000 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. / Made available in DSpace on 2012-10-17T22:48:17Z (GMT). No. of bitstreams: 0 / Avaliar a factibilidade e a eficácia do tratamento endovascular com à utilização de endopróteses auto-expansíveis em um modelo experimental de Aneurisma de Aorta Abdominal em cães. Em nenhum dos casos observou-se fuga, migração ou oclusão das endopróteses. O tratamento endovascular dos Aneurismas de Aorta Abdominal em modelo experimental em cães mostrou-se factúvel e eficaz.
7

Alterações do padrão fluxo sanguíneo após tratamento endovascular do aneurisma sacular da aorta com triplo stent : modelo em suínos

Oliveira, Jahir Richard de January 2012 (has links)
Resumo não disponível
8

Avaliação em médio prazo da pressão intra-saco após correção endovascular de aneurisma de aorta abdominal com o uso de sensor sem fio

Lain, Vinícius Victorazzi January 2010 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Ciências Médicas. / Made available in DSpace on 2013-07-16T03:50:53Z (GMT). No. of bitstreams: 1 310110.pdf: 339089 bytes, checksum: 73dbf9bdb335a97c9e58214037a9667e (MD5) / Justificativa: O objetivo do tratamento endovascular do aneurisma de aorta abdominal é a exclusão do saco aneurismático da circulação sistêmica. Para acompanhar a eficácia do tratamento é necessária a realização de angiotomografias seriadas. A monitorização continuada da pressão poderia diagnosticar precocemente casos em que esteja ocorrendo falha desse tratamento, auxiliando ou substituindo a tomografia. Objetivo: Avaliar a eficácia em médio prazo da medida de pressão através de sensor sem fio implantado no saco aneurismático após tratamento endovascular de aneurisma de aorta abdominal (AAA). Desenho do Estudo: Quarenta pacientes submetidos a tratamento endovascular de aneurisma de aorta abdominal receberam implante de sensor sem fio para monitorização em médio prazo da pressão intra-saco. Os dados foram analisados no primeiro, sexto, décimo segundo meses e anualmente. A cada análise, uma angiotomografia informava o diâmetro do aneurisma, presença e tipo de vazamento. A pressão arterial sistêmica assim como todos os dados pressóricos obtidos através do sensor foram coletados. Resultados: No seguimento, dos 40 sensores implantados apenas em dois o sinal não pode ser detectado. A pressão de pulso obtida apresentou boa sensibilidade em afastar a presença de vazamento quando inferior a 25mmHg no primeiro ano. Após esse período, o Índice de Endotensão mostra-se como a variável que mais se aproxima dos dados tomográficos. Na presença de vazamantos tipo I ou III, o sensor é capaz de identificar sucesso ou falha após a correção do vazamento. Até o segundo ano de seguimento, resultados apresentados pelo sensor são concordantes com dados tomográficos, a partir daí, perdem acurácia. Conclusão: Na amostra estudada não foi possível obter sensibilidade suficiente para substituir a realização da tomografia no acompanhamento dos AAA tratados por técnica endovascular. Um maior número de pacientes é necessário para estabelecer o verdadeiro papel da monitorização pressórica sem fio no seguimento do tratamento endovascular do aneurisma de aorta abdominal. / Racional: The objective of endovascular treatment of an abdo-minal aortic aneurysm is to exclude the aneurysm sac from systemic circulation. In order to assess treatment effectiveness it is necessary to perform serial computed tomography (CT). Continued pressure moni-toring could provide an early diagnosis of cases in which this treatment is failing, helping or replacing CT. Objective: Evaluation of medium-term effectiveness of pressure measurement using a wireless sensor implanted in the aneurysm sac after endovascular treatment of abdominal aortic aneurysm. Method: Forty patients undergoing endovascular treatment for abdominal aortic aneurysm had a wireless sensor implanted for medium-term monitoring of intrasac pressure. The data were analyzed in the first, sixth and twelfth month and annually. At each analysis, a CT scan in-formed the aneurysm diameter, presence and risk of endoleaks. System-ic arterial pressure was collected, as well as all pressure data obtained through the sensor. Results: Of the 40 sensors implanted, the signal could not be de-tected only in two. The pulse pressure obtained presented good sensitivi-ty to rule out the presence of leakage when it was less than 25mmHg during the first year. After this period, the Endotension Index is the variable that comes closest to the CT scan data. With type I or III endo-leaks, the sensor can identify success or failure after endoleak repair. Until the second year of follow up, the results presented by the sensor agree with CT data, and then become less accurate. Conclusions: In the sample studied sufficient sensitivity could not be achieved to replace the CT when following AAA treated by the en-dovascular technique. A larger number of patients is needed to deter-mine the true role of wireless pressure monitoring when following en-dovascular treatment of abdominal aortic aneurysm.
9

Análise dos aneurismas de aorta abdominal tratados com endoprótese fenestrada

Oliveira, Gustavo Paludetto 02 March 2018 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Medicina, Programa de Pós-Graduação em Ciências Médicas, 2018. / Submitted by Fabiana Santos (fabianacamargo@bce.unb.br) on 2018-08-17T21:42:56Z No. of bitstreams: 1 2018_GustavoPaludettoOliveira.pdf: 12493694 bytes, checksum: 6b41edf3a6a23dd88b25d1ab7952d147 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-08-21T17:52:25Z (GMT) No. of bitstreams: 1 2018_GustavoPaludettoOliveira.pdf: 12493694 bytes, checksum: 6b41edf3a6a23dd88b25d1ab7952d147 (MD5) / Made available in DSpace on 2018-08-21T17:52:25Z (GMT). No. of bitstreams: 1 2018_GustavoPaludettoOliveira.pdf: 12493694 bytes, checksum: 6b41edf3a6a23dd88b25d1ab7952d147 (MD5) Previous issue date: 2018-08-17 / Objetivo: O estudo relata os resultados de um centro único para avaliar a eficácia da Endoprótese (EP) Gore Excluder C3® (WL Gore, Flagstaff, AZ) modificada pelo cirurgião para o tratamento de aneurismas de aorta abdominal (AAA) justarrenais sintomáticos. Métodos: vinte e oito pacientes foram tratados e acompanhados de 2011 a 2013. O seguimento foi calculado por tomografia em 1, 6, 12 e 18 meses. O objetivo primário foi avaliar a ausência de Endoleak (EL) de tipo I e III. Os objetivos secundários foram a avaliação da patência dos stents, o diâmetro dos aneurismas, migração da EP e necessidade de intervenções secundarias. Resultados: houve 21 homens e 7 mulheres, com idade média de 71,1 anos de idade. O diâmetro médio do aneurisma foi de 61,8mm. Vinte e cinco pacientes não apresentaram EL I e III. Um total de 52 artérias viscerais foram envolvidas em fenestras: 09 pacientes necessitaram de 01 fenestras em uma artéria renal (AR), 14 pacientes de fenestras ambas as artérias renais e 05 pacientes foram tratados com 03 fenestras, para ambas artérias renais e Artéria Mesentérica Superior (SMA). Três pacientes (10,7%) tiveram migração da EP maior que 5mm. Houve 02 oclusões AR e 01 de SMA. Dois pacientes (7,1%) necessitaram de intervenções secundárias para tratamento de oclusão da artéria renal e EL de tipo I ou III. O diâmetro médio de AAA após 18 meses foi de 53,9mm e houve diminuição maior que 5 mm em 17 (60,7%) dos 28 pacientes. A taxa de pacientes livre de intervenções secundárias foi de 92,9%. Não ocorreram mortes relacionadas ao procedimento. Conclusão: Este estudo retrospectivo demonstrou que o tratamento endovascular de AAA justa/pararrenais com a EP Gore Excluder C3® modificada pelo cirurgião foi efetivo e pode ser uma opção para tratar pacientes selecionados em casos de emergência. / Objective: This study reports the results of a single center trial to evaluate the effectiveness of the Surgeon Modified Gore Excluder C3® (WL Gore, Flagstaff, AZ) for treatment of symptomatic juxtarenal abdominal aortic aneurysms (AAAs). Methods: Twenty-eight patients were treated from 2011 to 2013. Follow-up was computed by tomography imaging at 1, 6, 12 and 18 months. Primary end point included absence of type I and III Endoleak (EL). Secondary end points were patency of stents, change in aneurysm diameter, migration and surveillance freedom from re-interventions. Results: There were 21 male and 7 female patients with a mean age of 71,1 years old. Mean aneurysm diameter was 61,8mm. Twenty-five patients had no EL I and III. A total of 52 visceral arteries required fenestrations incorporations: 09 patients required 01 fenestration to one renal artery (RA), 14 patients had 02 both RA fenestrations and 05 patients had 03 fenestrations to both RA and Superior Mesenteric Artery (SMA). Three patients (10,7%) had migration >5mm. There were 02 RA and 01 SMA occlusions. Two patients (7,1%) required secondary interventions for renal artery occlusion and type I or III EL. Mean AAA diameter after 18 months was 53,9mm and there was a greater than 5 mm decrease in 17 (60,7%) out of 28 patients. Freedom from secondary interventions was 92,9%. No deaths occurred. Conclusion: This retrospective study demonstrated that endovascular repair of juxtarenal AAAs with the Modified Gore Excluder C3® was effective and can be an option to treat selected patients in emergency cases.
10

Alterações do padrão fluxo sanguíneo após tratamento endovascular do aneurisma sacular da aorta com triplo stent : modelo em suínos

Oliveira, Jahir Richard de January 2012 (has links)
Resumo não disponível

Page generated in 0.0705 seconds