Spelling suggestions: "subject:"aparelho respiratória - fisiologia"" "subject:"parelho respiratória - fisiologia""
1 |
Efeito do docetaxel e da dexametasona nas propriedades mecânicas e na histologia dos pulmõesMoreira, Gabrielle Scattolin 21 May 2015 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Medicina, Programa de Pós-Gradua cão em Ciências Médicas, 2015. / Submitted by Tania Milca Carvalho Malheiros (tania@bce.unb.br) on 2015-11-16T17:52:44Z
No. of bitstreams: 1
2015_GabrielleScattolinMoreira.pdf: 20626840 bytes, checksum: b85c4b405753b0407b7c06acbcef80fb (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2015-12-01T20:53:54Z (GMT) No. of bitstreams: 1
2015_GabrielleScattolinMoreira.pdf: 20626840 bytes, checksum: b85c4b405753b0407b7c06acbcef80fb (MD5) / Made available in DSpace on 2015-12-01T20:53:54Z (GMT). No. of bitstreams: 1
2015_GabrielleScattolinMoreira.pdf: 20626840 bytes, checksum: b85c4b405753b0407b7c06acbcef80fb (MD5) / Introducão: A prevalência estimada de pneumonia induzida por docetaxel e de 10% sendo fatal em 40% dos casos e os corticóides são rotineiramente utilizados para reduzir a incidência de náuseas, vômitos e de síndrome de retencão hídrica induzida pelos taxanes. Contudo, são escassos os estudos que avaliam se o seu uso e capaz de reduzir os efeitos delet erios do docetaxel aos pulmões. Objetivo: avaliar se a dexametasona e capaz de atenuar as alteracões mecânicas do sistema respiratório e da morfologia do tecido pulmonar de ratos expostos ao docetaxel. Métodos: 64 ratos da raça wistar foram divididos em 8 grupos de acordo com as doses de docetaxel administradas (0, 70, 140 e 210 mg.m2) e a dexametasona (quando aplicada) foi administrada na dose de 5 mg.kg1 concomitantemente com o docetaxel e ap ós 24 e 48 horas da primeira dose. Ap ós 4 semanas, foram avaliadas a impedância do sistema respiratório e dos pulmões, e a morfologia do tecido pulmonar. Resultados: O docetaxel aumentou a elastância
estática do sistema respiratório (p=0,04), a dissipação (p<0,001) e a conservacão de energia no tecido pulmonar (p=0,024), e a deposi cão do colágeno no parênquima pulmonar (p<0,001) sem quaisquer efeitos protetores da dexametasona para estas variáveis. Houve interação entre docetaxel/dexametasona no aumento do depósito de brascolagenas nos vasos pulmonares (p=0,04). Conclusões: A exceção do remodelamento vascular pulmonar, a dexametasona não atenuou o aumento da impedância do sistema respiratório, dos pulmões, e da deposicão de colágeno no parênquima pulmonar após administração única de docetaxel. / Rationale: the estimated prevalence of docetaxel-induced pneumonia is 10% being fatal in 40% of the cases and the corticosteroids are routinely administered in clinical practice to reduce
the incidence of taxane-induced nausea, vomiting and uid retention syndrome. However, there are few studies that evaluate whether its use can reduce the deleterious e ects of docetaxel
to the lungs. Objective: to evaluate whether the dexamethasone can mitigate the
alterations of the respiratory system mechanical properties and lung tissue morphology of rats exposed to docetaxel. Methods: 64 male wistar rats were divided into 8 groups according to the docetaxel doses (0, 70, 140, and 210 mg.m2) and dexamethasone (5 mg.kg1, when applied) was concomitantly administered with the docetaxel and 24 and 48 hours after the
rst dose injected. After 4 weeks the respiratory system and lung's impedances and the lung tissue morphology were evaluated. Results: The docetaxel increased the respiratory system
elastic elastance (p=0,04), the energy dissipation (p<0,001) and conservation (p=0,024) in the lung tissue, and the collagen ber deposition in the lung parenchyma (p<0,001) without any
protection e ects of the dexamethasone for these variables. There was an interaction e ect of docetaxel/dexamethasone on the collagen ber deposition in the lung vasculature (p=0,04). Conclusions: Except to the lung vascular remodeling, the dexamethasone did not mitigate
the docetaxel-induced increase of the respiratory system and lung impedances was well as the collagen deposition in the lung parenchyma.
|
2 |
Propostas de técnicas para caracterização e classificação automática de sons pulmonares adventíciosRiella, Rodrigo Jardim 2010 October 1914 (has links)
Nesta tese, descrevem-se técnicas matemáticas visando a caracterização e classificação de sons pulmonares adventícios, por meio de sua análise espectral. Para alcançar este objetivo, desenvolveu-se duas novas metodologias, que utilizam Análise em Multiresolução, implementada a partir da Transformada Wavelet Discreta. A primeira metodologia desenvolvida é utilizada para classificar automaticamente os sons pulmonares em quatro grupos: sons normais e sons adventícios contínuos e descontínuos, notificando também o caso de ocorrência das duas anomalias no mesmo ciclo respiratório. Durante o processamento, o ciclo respiratório é decomposto até seu décimo nível, calculando a energia dos coeficientes detalhe em cada nível de decomposição, assim como a energia dos coeficientes de aproximação. Deste cálculo, obtém-se uma curva de variação da energia em relação ao nível de decomposição, sendo que as curvas obtidas se mostraram curvas caracterísitcas em relação ao tipo de som adventício. Tais curvas são aplicadas a uma simulação de Rede Neural Artificial de Função de Base Radial, que atua como classificador entre os quatro grupos. Esta técnica foi testada utilizando dez wavelets, sendo treinadas cem redes neurais para cada uma. Os melhores resultados apresentaram índice de acerto entre 88% e 92,36% para o conjunto de teste, em um total de 275 ciclos respiratórios. A segunda metodologia, denominada Filtragem por Análise Espectral Seletiva, decompõe o som pulmonar até seu quarto nível, calculando o espectro dos coeficientes aproximação e, baseado na componente de frequência prepoderante, calcula um filtro FIR multibanda. Este filtro é utilizado para eliminar todas as {sic} componentes espectrais dos coeficientes de aproximação, com exceção do mais proeminente. Após o procedimento de filtragem, o sinal é recomposto através de reconstrução wavelet. Para a avaliação de seus resultados, foram testadas dez wavelets no processo de decomposição e reconstrução. Para a wavelet que apresentou melhores resultados, obteve-se uma atenuação dos sons cardíacos da ordem de 6dB em relação aos sons adventícios que ocorrem na mesma faixa espectral, utilizando a Densidade Espectral de Potência dos sinais como referência. Esta metodologia mostrou resultados satisfatórios na tarefa de eliminar tanto os ruídos relativos ao fluxo aéreo normal nas vias aeríferas quanto os sons cardíacos, mantendo somente os sons adventícios nas gravações de sons pulmonares. / In this thesis, the investigation of methods to characterize and classify adventitious lung sounds by spectral analysis is described. To accomplish this task, two novel techniques were developed, through Multiressolution Analysis, based on the Discrte Wavelet Transform. The first technique aims to detect abnormal sounds and classity them info four groups: normal, continuous and discontinuous adventitions lung sounds, also notifying their simultaneous occurence. During its processing, the respiratory cycle signal is decomposed up to its tenth level, and the energy present in the detail and approximation coefficients for each decomposition level is calculated, resulting on a curve of energy versus decomposition level. The resulting curves show different signatures for each kind of adventitious sound. These signatures are used as data source for a classifier system based on Radial Basis Function Artificial Neural Networks. This technique was tested for ten different wavelets, training a hundred neural networks for each wavelet, totalizing a thousand neural networks trained. The best performance rates for each wavelet reach values from 88% to 92.36% for the test group, in a set of 275 respiratory cycles. In the second technique, named Filtering by Selective Spectral Analysis, the lung sound is decomposed until its fourth level, the approximation coefficients spectra are calculatedand, based on the highest frequency component found on those coefficients, a multiband FIR filter is determined. This filter is used to eliminate all frequency components in the approximation coefficients except the highest one. After the filtering procedure, the signal is recomposed by wavelet reconstruction. In order to evaluate the proposed technique, ten wavelets were used in the decomposition and reconstruction stages. The wavelet which presented the best performance attenuated heart sounds 6 dB more than the adventitious sounds that occur in the same spectral band. For measuring this attenuation, the Power Spectral Density was used. This procedure showed satisfactory results, elimination the normal airflow noise and cardiac sounds, leaving only the adventitious sounds in the recorded lung sounds.
|
3 |
Propostas de técnicas para caracterização e classificação automática de sons pulmonares adventíciosRiella, Rodrigo Jardim 2010 October 1914 (has links)
Nesta tese, descrevem-se técnicas matemáticas visando a caracterização e classificação de sons pulmonares adventícios, por meio de sua análise espectral. Para alcançar este objetivo, desenvolveu-se duas novas metodologias, que utilizam Análise em Multiresolução, implementada a partir da Transformada Wavelet Discreta. A primeira metodologia desenvolvida é utilizada para classificar automaticamente os sons pulmonares em quatro grupos: sons normais e sons adventícios contínuos e descontínuos, notificando também o caso de ocorrência das duas anomalias no mesmo ciclo respiratório. Durante o processamento, o ciclo respiratório é decomposto até seu décimo nível, calculando a energia dos coeficientes detalhe em cada nível de decomposição, assim como a energia dos coeficientes de aproximação. Deste cálculo, obtém-se uma curva de variação da energia em relação ao nível de decomposição, sendo que as curvas obtidas se mostraram curvas caracterísitcas em relação ao tipo de som adventício. Tais curvas são aplicadas a uma simulação de Rede Neural Artificial de Função de Base Radial, que atua como classificador entre os quatro grupos. Esta técnica foi testada utilizando dez wavelets, sendo treinadas cem redes neurais para cada uma. Os melhores resultados apresentaram índice de acerto entre 88% e 92,36% para o conjunto de teste, em um total de 275 ciclos respiratórios. A segunda metodologia, denominada Filtragem por Análise Espectral Seletiva, decompõe o som pulmonar até seu quarto nível, calculando o espectro dos coeficientes aproximação e, baseado na componente de frequência prepoderante, calcula um filtro FIR multibanda. Este filtro é utilizado para eliminar todas as {sic} componentes espectrais dos coeficientes de aproximação, com exceção do mais proeminente. Após o procedimento de filtragem, o sinal é recomposto através de reconstrução wavelet. Para a avaliação de seus resultados, foram testadas dez wavelets no processo de decomposição e reconstrução. Para a wavelet que apresentou melhores resultados, obteve-se uma atenuação dos sons cardíacos da ordem de 6dB em relação aos sons adventícios que ocorrem na mesma faixa espectral, utilizando a Densidade Espectral de Potência dos sinais como referência. Esta metodologia mostrou resultados satisfatórios na tarefa de eliminar tanto os ruídos relativos ao fluxo aéreo normal nas vias aeríferas quanto os sons cardíacos, mantendo somente os sons adventícios nas gravações de sons pulmonares. / In this thesis, the investigation of methods to characterize and classify adventitious lung sounds by spectral analysis is described. To accomplish this task, two novel techniques were developed, through Multiressolution Analysis, based on the Discrte Wavelet Transform. The first technique aims to detect abnormal sounds and classity them info four groups: normal, continuous and discontinuous adventitions lung sounds, also notifying their simultaneous occurence. During its processing, the respiratory cycle signal is decomposed up to its tenth level, and the energy present in the detail and approximation coefficients for each decomposition level is calculated, resulting on a curve of energy versus decomposition level. The resulting curves show different signatures for each kind of adventitious sound. These signatures are used as data source for a classifier system based on Radial Basis Function Artificial Neural Networks. This technique was tested for ten different wavelets, training a hundred neural networks for each wavelet, totalizing a thousand neural networks trained. The best performance rates for each wavelet reach values from 88% to 92.36% for the test group, in a set of 275 respiratory cycles. In the second technique, named Filtering by Selective Spectral Analysis, the lung sound is decomposed until its fourth level, the approximation coefficients spectra are calculatedand, based on the highest frequency component found on those coefficients, a multiband FIR filter is determined. This filter is used to eliminate all frequency components in the approximation coefficients except the highest one. After the filtering procedure, the signal is recomposed by wavelet reconstruction. In order to evaluate the proposed technique, ten wavelets were used in the decomposition and reconstruction stages. The wavelet which presented the best performance attenuated heart sounds 6 dB more than the adventitious sounds that occur in the same spectral band. For measuring this attenuation, the Power Spectral Density was used. This procedure showed satisfactory results, elimination the normal airflow noise and cardiac sounds, leaving only the adventitious sounds in the recorded lung sounds.
|
Page generated in 0.0844 seconds