• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Diagnóstico de fraturas verticais mésio-distais em dentes com pino metálico: influência da aplicação de filtros em imagens de TCFC de diferentes resoluções

Silva, Débora de Martin e 03 October 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-01-10T11:02:38Z No. of bitstreams: 1 deborademartinesilva.pdf: 1886712 bytes, checksum: 5ecc4d3526d4a3d4a1302e9997a870da (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2017-01-31T11:21:03Z (GMT) No. of bitstreams: 1 deborademartinesilva.pdf: 1886712 bytes, checksum: 5ecc4d3526d4a3d4a1302e9997a870da (MD5) / Made available in DSpace on 2017-01-31T11:21:03Z (GMT). No. of bitstreams: 1 deborademartinesilva.pdf: 1886712 bytes, checksum: 5ecc4d3526d4a3d4a1302e9997a870da (MD5) Previous issue date: 2016-10-03 / O objetivo nesse estudo foi avaliar a influência da aplicação de filtros em imagens de tomografia computadorizada de feixe cônico (TCFC), de diferentes resoluções, obtidas para diagnóstico de fraturas radiculares verticais (FRV) mésio-distais, associadas a dentes com pinos metálicos. Quarenta dentes foram tratados endodonticamente e vinte receberam pinos metálicos. Dez dentes sem pino e dez dentes com pino foram submetidos à FRV no sentido mésio-distal. A amostra foi submetida a radiografias periapicais e a exames de TCFC com voxel de 0,25 e 0,30 mm. Com o objetivo de reduzir a influência do artefato metálico nas imagens tomográficas, as mesmas foram avaliadas com e sem a aplicação de filtros (“Sharpen” e “Hard”). As imagens foram avaliadas por dois radiologistas que deveriam identificar a presença da FRV. Valores de acurácia (curva ROC) para as diversas variáveis foram comparados por meio de análise de variância e teste t. Não foi observada diferença entre as imagens com e sem a aplicação dos filtros (p = 0,860). Imagens obtidas com voxel de 0,25 mm foram mais acuradas (p = 0,001). A presença do pino metálico reduziu a acurácia do diagnóstico de FRV (p = 0,001) e as imagens tomográficas mostraram resultados superiores quando comparadas à radiografia periapical (p = 0,005). Pode-se concluir que a presença de pino metálico e o tamanho do voxel interferem significativamente no diagnóstico de FRV. Independente da formação de artefatos metálicos associados aos pinos metálicos, a aplicação de filtros não melhorou o diagnóstico. Para FRV mésio-distais, as imagens de TCFC são superiores às periapicais. / The aim of this study was to evaluate the influence of applying filters in cone beam computed tomography (CBCT) images at different resolutions. These CBCT images were obtained for diagnosing mesiodistal vertical root fractures (VRF) in teeth with metal posts. Forty teeth were treated endodontically, and twenty received metal posts. Ten teeth without posts and ten teeth with posts were subjected to VRF in the mesiodistal direction. The sample was submitted to periapical radiographs and CBCT exams with a voxel of 0.25 and 0.30 mm. In order to reduce the influence of the metal artifact in the CT images, the teeth were evaluated with and without the application of filters ("Sharpen" and "Hard"). The images were evaluated by two radiologists who had to identify the presence of VRF. Accuracy values (ROC curves) for the different variables were compared using an analysis of variance and t-test. No difference was observed between images with and without filter application (p = 0.860). Images obtained with a 0.25 mm voxel were more accurate (p = 0.001). The presence of the metal post reduced the accuracy of the diagnosis of VRF (p = 0.001), and the CT images showed superior results compared to periapical radiographs (p = 0.005). It can be concluded that the presence of a metal post and the voxel size significantly interfere with the diagnosis of VRF. Independent of the formation of metal artifacts associated with metallic cores, applying filters did not improve the diagnosis. For mesiodistal VRF, the CBCT images are superior to the periapical radiographs.
2

Influência de artefatos metálicos produzidos pela presença de implantes de titânio na análise das cristas ósseas periodontais adjacentes, em tomografia computadorizada de feixe cônico / Assessment of the influence of metallic artefacts caused by dental titanium implants in cone beam computed tomography images at periodontal adjacent structures

Caio Cesar Cremonini 01 June 2015 (has links)
Objetivo: Avaliação da influência de artefatos metálicos nas imagens de tomografia computadorizada de feixe cônico (TCFC), causados por implantes dentários, nas estruturas periodontais dos dentes adjacentes a esse implante. Materiais e Métodos: 23 pacientes foram submetidos ao exame de TCFC antes e após a colocação do implante dentário. Foram realizadas medidas da espessura das corticais vestibulares (CV) por um observador calibrado (ICC=0,95), nos cortes parassagitais de imagens previamente obtidas. Foi calculada a frequência de graus de influência do artefato metálico causado pelo implante (leve, moderado e severo) para distância horizontal ao implante, espessura da CV, e distância vertical em relação à crista óssea vestibular (COV). Resultados: excluídos 5 pacientes, em 18 selecionados, examinou-se 24 implantes unitários na região posterior de mandíbula, sendo 24 dentes teste mesiais (DTM) e 17 dentes teste distais (DTD) a esses implantes. Houve associação entre distância vertical da COV e impossibilidade de se mensurar a espessura da CV para o DTM e DTD (p<0,05 para ambos). Não houve associação entre espessura da cortical vestibular e distância horizontal para a severidade de influência de artefatos (p>0,05 para ambos). Houve associação entre distância horizontal e nível de influência de artefatos em quaisquer estruturas periodontais adjacentes ao implante, para DTM e DTD somados (p<0,05). Conclusão: Os artefatos metálicos causados por implantes dentários podem influenciar a interpretação da imagem de TCFC em sítios periodontais adjacentes, e o grau de influência depende da distância horizontal do implante dentário a quaisquer estruturas periodontais, e quanto mais próximo da COV, maior influência do artefato na identificação e mensuração de estruturas na CV. / Objective: The objective of this study was to evaluate the influence of metallic artifacts in CBCT (Cone beam computed tomography) images, caused by dental titanium implants, at adjacent periodontal structures. Materials and Methods: 23 patients were submitted a CBCT examination before and after the implant placement. Thickness Measurements of buccal cortical were performed by a calibrated observer (ICC=0.95), at parassagital cross-sections of previously obtained images. The frequency of influence level (mild, moderate, severe) of the artifact was calculated for horizontal distance of the implant, buccal cortical thickness and vertical distance of the buccal alveolar crest. Results: 5 patients were excluded, and 18 selected, 24 unitary implants cases at posterior mandible were examined, 24 mesial test teeth (MTT) and 17 Distal test teeth (DTT) from the implants. There was an association between the vertical distance of the buccal alveolar crest and the impossibility to measure the thickness of buccal cortical for MTT and DTT (p<0.05 for both). There was no association between the thickness of buccal cortical and horizontal distance for the artifacts level of influence (p>0.05 for both). There was association between horizontal distance and the level of the artifact influence at any periodontal structure, for the sum of MTT and DTT (p<0.05). Conclusion: the metallic artifacts caused by dental implants can influence the CBCT image interpretation at periodontal adjacent sites, and the level of the influence depends on the horizontal distance of the dental implant at any periodontal structures, and the vertical distance from the buccal alveolar crest.
3

Influência de artefatos metálicos produzidos pela presença de implantes de titânio na análise das cristas ósseas periodontais adjacentes, em tomografia computadorizada de feixe cônico / Assessment of the influence of metallic artefacts caused by dental titanium implants in cone beam computed tomography images at periodontal adjacent structures

Cremonini, Caio Cesar 01 June 2015 (has links)
Objetivo: Avaliação da influência de artefatos metálicos nas imagens de tomografia computadorizada de feixe cônico (TCFC), causados por implantes dentários, nas estruturas periodontais dos dentes adjacentes a esse implante. Materiais e Métodos: 23 pacientes foram submetidos ao exame de TCFC antes e após a colocação do implante dentário. Foram realizadas medidas da espessura das corticais vestibulares (CV) por um observador calibrado (ICC=0,95), nos cortes parassagitais de imagens previamente obtidas. Foi calculada a frequência de graus de influência do artefato metálico causado pelo implante (leve, moderado e severo) para distância horizontal ao implante, espessura da CV, e distância vertical em relação à crista óssea vestibular (COV). Resultados: excluídos 5 pacientes, em 18 selecionados, examinou-se 24 implantes unitários na região posterior de mandíbula, sendo 24 dentes teste mesiais (DTM) e 17 dentes teste distais (DTD) a esses implantes. Houve associação entre distância vertical da COV e impossibilidade de se mensurar a espessura da CV para o DTM e DTD (p<0,05 para ambos). Não houve associação entre espessura da cortical vestibular e distância horizontal para a severidade de influência de artefatos (p>0,05 para ambos). Houve associação entre distância horizontal e nível de influência de artefatos em quaisquer estruturas periodontais adjacentes ao implante, para DTM e DTD somados (p<0,05). Conclusão: Os artefatos metálicos causados por implantes dentários podem influenciar a interpretação da imagem de TCFC em sítios periodontais adjacentes, e o grau de influência depende da distância horizontal do implante dentário a quaisquer estruturas periodontais, e quanto mais próximo da COV, maior influência do artefato na identificação e mensuração de estruturas na CV. / Objective: The objective of this study was to evaluate the influence of metallic artifacts in CBCT (Cone beam computed tomography) images, caused by dental titanium implants, at adjacent periodontal structures. Materials and Methods: 23 patients were submitted a CBCT examination before and after the implant placement. Thickness Measurements of buccal cortical were performed by a calibrated observer (ICC=0.95), at parassagital cross-sections of previously obtained images. The frequency of influence level (mild, moderate, severe) of the artifact was calculated for horizontal distance of the implant, buccal cortical thickness and vertical distance of the buccal alveolar crest. Results: 5 patients were excluded, and 18 selected, 24 unitary implants cases at posterior mandible were examined, 24 mesial test teeth (MTT) and 17 Distal test teeth (DTT) from the implants. There was an association between the vertical distance of the buccal alveolar crest and the impossibility to measure the thickness of buccal cortical for MTT and DTT (p<0.05 for both). There was no association between the thickness of buccal cortical and horizontal distance for the artifacts level of influence (p>0.05 for both). There was association between horizontal distance and the level of the artifact influence at any periodontal structure, for the sum of MTT and DTT (p<0.05). Conclusion: the metallic artifacts caused by dental implants can influence the CBCT image interpretation at periodontal adjacent sites, and the level of the influence depends on the horizontal distance of the dental implant at any periodontal structures, and the vertical distance from the buccal alveolar crest.
4

Influência da região anatômica na formação de artefatos metálicos produzidos por implantes dentários em imagens de tomografia computadorizada de feixe cônico / Effect of anatomical region on the formation of metal artifacts produced by dental implants in cone beam computed tomographic images

Machado, Alessiana Helena 21 July 2017 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-08-21T19:15:12Z No. of bitstreams: 1 alessianahelenamachado.pdf: 2020827 bytes, checksum: 87061a02b07d6d6e92c3f1dcee06da4c (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-24T12:04:37Z (GMT) No. of bitstreams: 1 alessianahelenamachado.pdf: 2020827 bytes, checksum: 87061a02b07d6d6e92c3f1dcee06da4c (MD5) / Made available in DSpace on 2017-08-24T12:04:37Z (GMT). No. of bitstreams: 1 alessianahelenamachado.pdf: 2020827 bytes, checksum: 87061a02b07d6d6e92c3f1dcee06da4c (MD5) Previous issue date: 2017-07-21 / O objetivo no presente estudo foi comparar, quantitativamente, os artefatos metálicos produzidos em imagens de tomografia computadorizada de feixe cônico (TCFC) por implantes instalados em diferentes regiões maxilomandibulares. Para isso, um total de 200 implantes, selecionados de exames de TCFC, foi dividido em quatro grupos: Grupo 1 (n = 50) - implantes localizados na região anterior da maxila; Grupo 2 (n = 50) - implantes localizados na região posterior da maxila; Grupo 3 (n = 50) - implantes localizados na região anterior da mandíbula e Grupo 4 (n = 50) - implantes localizados na região posterior da mandíbula. Os implantes ainda foram classificados em isolados ou adjacentes a outros implantes. Foram selecionados três cortes axiais de cada implante incluído na amostra (apical, médio e cervical). Nesses cortes foram mensurados os artefatos produzidos pelos implantes. Para comparar as variáveis com dois grupos foi aplicado o teste U de Mann-Whitney. Para a comparação entre os cortes axiais foram aplicados os testes de Kruskal-Wallis e Student-Newman-Keuls. A mandíbula apresentou uma quantidade de artefatos maior que a maxila (corte apical: p = 0,0024; corte médio: p < 0,0001). A região anterior produziu mais artefatos que a região posterior (corte apical: p = 0,0105; corte médio: p < 0,0316). Não houve diferença significativa na quantidade de artefatos entre implantes isolados e adjacentes e o corte cervical foi o mais acometido por artefatos. Pode-se concluir que os implantes dentários sempre produzem artefatos metálicos em imagens de TCFC, sendo esses artefatos influenciados pela localização anatômica na arcada dentária. / The objective of the present study was to compare, quantitatively, the metal artifacts produced in cone beam computed tomography (CBCT) images by dental implants installed in different maxillomandibular regions. A total of 200 implants selected from CBCT examinations were divided into four groups: Group 1 (n = 50) - implants located in the anterior maxilla; Group 2 (n = 50) - implants located in the posterior maxilla; Group 3 (n = 50) - implants located in the anterior mandible; and Group 4 (n = 50) - implants located in the posterior mandible. The implants were further classified as isolated or adjacent to other implants. Three axial slices were selected for each sampled implant (apical, middle and cervical). On each slice, the artifacts produced by the implants were counted. The Mann-Whitney U test was used to compare the variables between groups. The Kruskal-Wallis and Student-NewmanKeuls tests were used to compare the axial slices. The mandible showed a greater number of artifacts than the maxilla (apical slice: p = 0.0024; middle slice: p < 0.0001). The anterior region produced more artifacts than the posterior region (apical slice: p = 0.0105; middle slice: p < 0.0316). There was no significant difference in the number of artifacts between isolated and adjacent implants, and the cervical slice was most affected by artifacts. It can be concluded that dental implants always produce metal artifacts in CBCT images, and these artifacts are affected by the anatomical location in the dental arch.
5

Quantificação de artefatos metálicos produzidos por implantes dentários em imagens de tomografia computadorizada de feixe cônico obtidas com diferentes protocolos de aquisição / Quantification of metallic artifacts produced by dental implants in cbct images obtained using different acquisition protocols

Fardim, Karolina Aparecida Castilho 08 August 2018 (has links)
Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-10-24T11:31:17Z No. of bitstreams: 0 / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-10-24T15:48:14Z (GMT) No. of bitstreams: 0 / Made available in DSpace on 2018-10-24T15:48:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2018-08-08 / O objetivo do trabalho foi quantificar, em imagens de tomografia computadorizada de feixe cônico (TCFC) obtidas com diferentes protocolos, os artefatos metálicos produzidos por implantes de titânio instalados em diferentes regiões da mandíbula. Os implantes foram instalados em quatro diferentes regiões (incisivo, canino, pré-molar e molar) de um phamtom e submetidos a exames de TCFC com variação da posição do objeto no interior do FOV (central, anterior, posterior, direita e esquerda), variação do FOV (6 x 13 e 12 x 13 cm) e do tamanho do voxel (0,25 e 0,30 mm). Um corte axial da região cervical de cada implante foi selecionado para quantificação. Os testes de Kruskal-Wallis e Student-Newman-Keuls foram utilizados para comparação das regiões dos dentes e entre as diferentes posições do phantom dentro do FOV. O teste de Wilcoxom foi utilizado para comparar a variação de tamanho do FOV e voxel. O teste ANOVA fatorial para avaliar a interação entre as variáveis do estudo. A região de incisivo apresentou a maior quantidade de artefatos, em comparação as outras regiões (p=0,0315). Não houve diferença significativa na variação da posição do phantom dentro do FOV (p=0,7418). O FOV menor produziu mais artefatos (p<0,0001). Ao comparar as imagens produzidas com diferentes resoluções, o menor voxel produziu mais artefatos (p<0,0001). Os artefatos metálicos sofrem influência do tamanho do FOV e do voxel, além da região anatômica. A variação da localização do phantom no interior do FOV não alterou a quantidade de artefatos. / O objetivo do trabalho foi quantificar, em imagens de tomografia computadorizada de feixe cônico (TCFC) obtidas com diferentes protocolos, os artefatos metálicos produzidos por implantes de titânio instalados em diferentes regiões da mandíbula. Os implantes foram instalados em quatro diferentes regiões (incisivo, canino, pré-molar e molar) de um phamtom e submetidos a exames de TCFC com variação da posição do objeto no interior do FOV (central, anterior, posterior, direita e esquerda), variação do FOV (6 x 13 e 12 x 13 cm) e do tamanho do voxel (0,25 e 0,30 mm). Um corte axial da região cervical de cada implante foi selecionado para quantificação. Os testes de Kruskal-Wallis e Student-Newman-Keuls foram utilizados para comparação das regiões dos dentes e entre as diferentes posições do phantom dentro do FOV. O teste de Wilcoxom foi utilizado para comparar a variação de tamanho do FOV e voxel. O teste ANOVA fatorial para avaliar a interação entre as variáveis do estudo. A região de incisivo apresentou a maior quantidade de artefatos, em comparação as outras regiões (p=0,0315). Não houve diferença significativa na variação da posição do phantom dentro do FOV (p=0,7418). O FOV menor produziu mais artefatos (p<0,0001). Ao comparar as imagens produzidas com diferentes resoluções, o menor voxel produziu mais artefatos (p<0,0001). Os artefatos metálicos sofrem influência do tamanho do FOV e do voxel, além da região anatômica. A variação da localização do phantom no interior do FOV não alterou a quantidade de artefatos.

Page generated in 0.0683 seconds