• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Determinação de frações de volume em fluxos bifásicos óleo-gás e água-gás utilizando redes neurais artificiais e densitometria gama

Peixoto, Philippe Netto Belache, Instituto de Engenharia Nuclear 04 1900 (has links)
Submitted by Almir Azevedo (barbio1313@gmail.com) on 2016-05-13T13:22:37Z No. of bitstreams: 0 / Made available in DSpace on 2016-05-13T13:22:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2016-04 / Este trabalho apresenta uma metodologia baseada nos princípios de atenuação de raios gama para a identificação de frações de volume em sistemas bifásicos compostos por óleo-gás e água-gás que são encontrados na indústria petrolífera offshore e onshore. Esta metodologia baseia-se no reconhecimento de contagens por segundo no fotopico da fonte de radiação, utilizando um sistema de detecção composto por um detector de Nal(TI), uma fonte de Cs137 sem colimação posicionada a 180º com relação ao detector em um regime de fluxo estratificado liso. A modelagem matemática para a simulação computacional utilizando o código Monte Carlo N-Particle eXtended (MCNP-X) foi realizada utilizando as medições experimentais das características do detector (resolução energética e eficiência), das características dos materiais água e óleo (densidade e coeficiente de atenuação) e a medição das frações de volume. Para a predição destas frações foram utilizadas redes neurais artificiais (RNAs) e para se obter um treinamento adequado das RNAs para a predição das frações de volume foram simuladas no código MCNP-X um maior número de frações de volume. Dados experimentais foram utilizados no conjunto de padrões necessários para a validação das RNAs e os dados gerados por meio do código computacional MCNP-X foram utilizados nos conjuntos de treinamento e teste das RNAs. Foram utilizadas RNAs do tipo feed-forward multilayer perceptron (MLP) e analisadas duas funções de treinamento, Levenberg-Marquadt (LM) e gradiente descendente com momento (GDM), ambas utilizando o algoritmo de treinamento Backpropagation. As RNAs identificaram corretamente as frações de volume no sistema multifásico, com erros relativos médios inferiores a 1,21%, possibilitando a aplicação desta metodologia para tal propósito
2

Estudo da técnica de rastreamento de partícula radioativa para avaliação de agitadores industriais utilizando redes neurais artificiais

Dam, Roos Sophia de Freitas, Instituto de Engenharia Nuclear 02 1900 (has links)
Submitted by Almir Azevedo (barbio1313@gmail.com) on 2018-04-27T12:15:53Z No. of bitstreams: 1 dissertação mestrado ien 2018 Roos Sophia de Freitas Dam.pdf: 1402693 bytes, checksum: 6a8bc7c98b0b3e3e3d55619f51dd2f72 (MD5) / Made available in DSpace on 2018-04-27T12:15:53Z (GMT). No. of bitstreams: 1 dissertação mestrado ien 2018 Roos Sophia de Freitas Dam.pdf: 1402693 bytes, checksum: 6a8bc7c98b0b3e3e3d55619f51dd2f72 (MD5) Previous issue date: 2018-02 / Agitadores ou misturadores são amplamente utilizados nas indústrias química, farmacêutica e de cosméticos quando processos como dispersão e homogeneização são desejados. Estes equipamentos são utilizados para misturar líquidos, promover reações de substâncias químicas, manter líquidos homogêneos durante armazenamento Agitadores industriais são construídos com características específicas para cada aplicação, dependendo de parâmetros como densidade, fase e viscosidade dos produtos a serem agitados. Durante a produção de um produto, o equipamento pode falhar e comprometer o procedimento de agitação ou mistura, tornando-se necessário avaliar o desempenho do misturador. Desta forma, é muito importante ter uma ferramenta de diagnóstico e de desempenho para unidades industriais visando garantir a qualidade do produto. O método utilizado neste trabalho baseia-se nos princípios da técnica de Rastreamento de Partícula Radioativa, que correlaciona as contagens obtidas por um arranjo de detectores com a posição instantânea ocupada por uma partícula radioativa. A geometria de detecção desenvolvida utiliza oito detectores cintiladores de NaI(Tl), uma fonte pontual de 137Cs (662 keV) com emissão isotrópica de raios gama e um tubo de policloreto de vinila como seção de teste. O modelo matemático foi desenvolvido utilizando o código MCNP-X, onde inicialmente o tubo é preenchido com ar e a partícula radioativa é posicionada em seu interior. Em um segundo momento, o tubo é preenchido com uma mistura de concreto. Nas duas situações, o algoritmo de localização utilizado pela rede foi capaz de predizer a posição instantânea da partícula radioativa. / Agitators or mixers are highly used in the chemical, pharmaceutical and cosmetic industries when processes such as dispersion and homogenization are desired. This equipment is used to mix liquids, promote reactions of chemical substances, keep homogeneous liquid bulk during storage. Agitators and mixers are designed for each application with specific configurations, depending on the characteristics, such as density, phase and viscosity of the agitated product. During the production process, the equipment may fail and compromise the stirring or mixing procedure, thus it is very important to have a diagnosis tool for these industrial units to assure the quality of the product. The method here presented is based on the principles of the radioactive particle tracking technique, which correlates the counts obtained by an array of detectors with the instantaneous position of the radioactive particle. The detection geometry developed in this work employs eight NaI(Tl) scintillation detectors, a 137Cs (662 keV) point source with isotropic emission of gamma-rays and a polyvinyl chloride tube as a test section. The mathematical model was developed using the MCNP-X code, where the tube is first filled with air and the radioactive particle is positioned inside it. Then, the tube is filled with a concrete mixture. In both situations, the search algorithm given by the network was capable to predict the instantaneous position of the radioactive particle.
3

Infiltração da água em amostras de solo indeformadas e remodeladas em colunas utilizando modelos determinísticos / Infiltration of water in undisturbed and remodeling soil samples in columns using deterministic models

Verena Benício de Oliveira 11 October 2018 (has links)
Define-se infiltração da água no solo como a entrada da água através da superfície do solo. O processo de infiltração separa, assim, quanto da precipitação pluvial, por exemplo, flui sobre a superfície do solo e quanto flui abaixo da superfície do solo, esta última tanto vertical como horizontalmente. Diversos fatores interferem neste processo, podendo-se destacar aqueles relacionados ao tipo de solo e declividade do terreno e às características do solo e da cobertura vegetal, bem como aquelas relacionadas à precipitação. São conhecidas diversas equações de infiltração, propostas para expressar a lei da infiltração da água em solos, que é o gráfico da taxa de infiltração da água com o tempo. São equações desenvolvidas empiricamente ou a partir de considerações físicas e aplicam-se somente a solos homogêneos e que permanecem homogêneos durante o processo. Dados da literatura têm mostrado que para nossos solos o avanço da frente de molhamento no processo de infiltração vertical também é proporcional à raiz quadrada do tempo, como a solução da equação de Richards obtida por Philip para a infiltração horizontal, porém com uma velocidade maior. Dado este fato, levanta-se a hipótese de utilizar a equação proposta por Philip para a infiltração na direção horizontal também para a direção vertical, em colunas com amostra de solo indeformada e com amostra de solo homogeneamente remodelada. Este trabalho trata do processo da infiltração de água no solo, especificamente a vertical descendente. Pretendeu-se avaliar as equações clássicas da lei da infiltração em amostras homogêneas de três solos estruturalmente distintos com estrutura deformada e indeformada. O experimento foi conduzido em latoratório, em nove colunas com amostras de três solos com características distintas, sendo um Cambissolo Háplico, um Latossolo Vermelho Amarelo distrófico e um Nitossolo Vermelho eutroférrico. As curvas da taxa de infiltração foram determinadas em laboratório e o conteúdo de água foi determinado pela técnica da atenuação gama. A equação proposta por Kostiakov para a lei da infiltração ajustou-se muito bem (máximo R2 para todos os solos, com exceção da coluna indeformada do Nitossolo) por praticamente coincidir com a equação de ajuste estatistico dos dados. Já o mesmo não ocorreu com a equação proposta por Horton para a qual os coeficientes de determinação variaram de 0,528 a 0,898 (sem considerer a amostra do Nitossolo indeformada). Com relação ao modelo de Green & Ampt que, ao contrário das equações de Kostiakov e Horton que são modelos empíricos, pode-se dizer tratar-se de um modelo semi-analítico, os ajustes dos dados também não foram muito bons (R2 variando de 0,802 a 0,898, sem considerer a amostra do Nitossolo indeformada). O modelo quase todo analítico de Philip, baseado na solução da equação de Richards para a direção horizontal, ajustou-se muito bem aos dados desta pesquisa que foi desenvolvida para a direção vertical descendente, visto que o gráfico da posição de frente de molhamento em relação a fonte de água em função da raiz quadrada do tempo de infiltração resultou numa linha reta com alto coeficiente de determinação para todas as amostras (R2 maior que 0,99 para as deformadas e R2 maior que 0,95 para as deformadas). Todos os modelos apresentaram um ajuste ruim (R2 menor que 0,1) para a coluna indeformada do solo 3 (Nitossolo). Provavelmente devido à presença de bioporo no interior da coluna, com fluxo preferencial da água ou também ao processo de amostragem que é muito dificuldato devido a forte estruturação deste solo. / Soil water infiltration is defined as the entry of water through the soil surface. The infiltration process thus separates how much of the rainfall, for example, flows over the soil surface and how much it flows below the surface of the soil, the latter both vertically and horizontally. Several factors interfere in this process, being possible to highlight those related to the type of soil and slope of the terrain and to the characteristics of the soil and vegetation cover, as well as those related to precipitation. Several infiltration equations are known, proposed to express the law of water infiltration in soils, which is the graph of the infiltration rate of water as a function of time. They are equations developed empirically or from physical considerations and apply only to homogeneous soils that remain homogeneous during the process. Literature data have shown that for our soils the advance of the wetting front in the vertical infiltration process is also proportional to the square root of the time, as the solution of the Richards equation obtained by Philip for horizontal infiltration, but with a higher velocity. Given this fact, the hypothesis is proposed to use the equation proposed by Philip for the infiltration in the horizontal direction also for the vertical direction, in columns with undisturbed soil sample and with homogeneously remodeled soil sample. This work deals especifically with the process of vertical descending soil water infiltration. It was intended to evaluate the classical equations of the infiltration law in homogeneous samples of three structurally distinct soils with disturbed and undisturbed structure. The experiment was carried out in a laboratory, in nine columns with three soils distinct characteristics, being a Haplic Cambisol, a Dystrophic Yellow Red Latosol and an eutrophic Red Nitosol. The infiltration rate curves were determined in the laboratory and the water content was determined by the gamma ray attenuation technique. The equation proposed by Kostiakov for the infiltration law adjusted very well (maximum R2 for all soils, except for the undisturbed Nitosol column) since it practically coincide with the equation of statistical fit of the data. The same did not occur with the equation proposed by Horton for which the coefficients of determination ranged from 0,528 to 0.898 (not considering the undisturbed column of Nitosol. In relation to the Green & Ampt model, unlike the Kostiakov and Horton equations that are empirical models, it can be said that it is a semi-analytical model, the data adjustments were also not good changing from 0,802 to 0,848 also not considering the undisturbed Nitosol. Philip\'s almost all-analytical model, based on the solution of the Richards equation for the horizontal direction, fitted very well the data from this work that were conducted in the downward vertical direction, since the graph of the wet facing front position the water source as a function of the square root of the infiltration time resulted in a straight line with a high coefficient of determination for all samples (R2 greater than 0.99 for the deformed and R2 greater than 0.95 for the deformed ones). All models presented a poor fit (R2 less than 0.01) for the undisturbed soil 3 column (Nitosol). Probably due to the presence of biopore inside the column, with preferential flow of water or to the sampling process that is very difficult due to the strong structure of this soil.
4

ÁREA ELEMENTAR REPRESENTATIVA DA DENSIDADE DO SOLO DE AMOSTRAS COLETADAS EM ANÉIS VOLUMÉTRICOS VIA ANÁLISE TOMOGRÁFICA

Ferreira, Talita Rosas 14 March 2014 (has links)
Made available in DSpace on 2017-07-21T19:26:08Z (GMT). No. of bitstreams: 1 Talita Rosas Ferreira.pdf: 6282017 bytes, checksum: f3b7825f0878fb8865db212f2fd79a70 (MD5) Previous issue date: 2014-03-14 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The computed tomography (CT) represents a technique that provides images of samples, allowing the study of different soil physical phenomena by qualitative and quantitative analysis in 2D and 3D. In the area of applied physics to porous media is a matter of investigation the definition of representative elementary areas (REA) regarding measurements of physical properties of this media. REA is related to the minimum area of a sample needed to represent its characteristics of interest. The aim of this study was to define REAs to be adopted for density (ρs) measurements from sample soil collected in volumetric rings. Having this purpose in mind, three soils with different textures were analyzed: Geric Ferralsol (GF), Rhodic Ferralsol (RF) and Eutric Nitosol (EN). Six samples from each soil were submitted to the method of volumetric ring (VR) and CT for ρs evaluation. A first generation tomograph equipped with 241Am gamma-ray source was used in the image acquisition. Consecutive areas were selected according to three different schemes (consecutive areas increasing from a first area selected at the center of the image and consecutive areas increasing from a first area selected at the inferior and superior borders of the sample) with size areas ranging from 1.2 to 678.8 mm². For ρs measurements, the following criteria were adopted: 1) relative deviation (RD) between ρs – RV and each of the areas not superior to 10, 8, 6, 4 and 2%; 2) RD between ρs - CT obtained for the last area selected inside the tomographic image and each of the remaining areas equally not superior than the criteria from item 1; 3) that at least three consecutive areas must not differ in RD values among themselves, using the variation criterion presented in items 1 and 2. It was considered that the REA for ρs was reached at the variation criteria of 4%. The REA found for ρs, according to the area selection starting from the center, superior and inferior borders of the tomographic images, were: 432.0; 393.3 and 334.0 mm² (GF), 473.1; 457.4 and 393.3 mm² (RF) and 349.7; 457.4 and 334,0 mm² (EN), respectively. The results obtained by the area selection starting from the center were assumed to be the real values of REA for the studied soils. In this study, it was also proposed an alternative criterion of analysis based on the results obtained, which use as reference, simultaneously, the methods of VR and CT. Therefore, it was possible to define that áreas measuring 432.0 mm² e 349.7 mm² provide, respectively , reliable density values for the LVA and NV soils. / A Tomografia Computadorizada (TC) é uma técnica que fornece imagens do interior de amostras, permitindo a investigação de diferentes fenômenos físicos que ocorrem no solo por meio de análises qualitativas e quantitativas em 2D e 3D. Na área de física aplicada a meios porosos, uma questão que vem sendo estudada nos últimos anos diz respeito à definição de áreas elementares representativas (AER) para medidas de propriedades físicas desses meios. A AER está relacionada com a área mínima de uma amostra, necessária para representar suas características de interesse. O objetivo deste estudo foi definir AERs para medidas de densidade (ρs) de amostras de solo coletadas em anéis volumétricos. Para isso, três solos de diferentes texturas foram analisados: Latossolo Vermelho-amarelo (LVA), Latossolo Vermelho (LVE) e Nitossolo Vermelho (NV). Seis amostras de cada solo foram submetidas a dois métodos para determinação da sua ρs: método do anel volumétrico (AV) e da TC. Para a obtenção das imagens foi utilizado um tomógrafo de raios gama de primeira geração equipado com fonte de 241Am. Foram selecionadas, nas imagens tomográficas, áreas consecutivas, de acordo com três diferentes esquemas (áreas concêntricas crescentes a partir de uma área no centro da amostra e áreas crescentes a partir de uma área selecionada nas bordas inferior e superior da amostra), com áreas variando de 1,2 até 678,8 mm². Para medidas de ρs, os seguintes critérios foram adotados para a definição da AER: 1) desvio relativo (DR) entre o valor médio de ρs - AV e cada uma das demais áreas não superior a 10, 8, 6, 4 e 2%; 2) DR entre o valor médio de ρs - TC obtido para a última área (UA) selecionada na imagem tomográfica e para cada uma das demais áreas igualmente não superior aos critérios do item 1; 3) que pelo menos três áreas consecutivas não devessem diferir entre si nos valores de ρs, de acordo com os itens 1 e 2. Considerou-se que a AER para a ρs foi atingida no critério de variação de 4%. As AERs obtidas para ρs, de acordo com uma seleção de áreas partindo do centro, face inferior e face superior das imagens tomográficas foram, respectivamente, 432,0; 393,3 e 334,0 mm² (solo LVA), 473,1; 457,4 e 393,3 mm² (solo LVE) e 349,7; 457,4 e 334,0 mm² (solo NV). Os resultados obtidos por meio da seleção de áreas partindo do centro das imagens tomográficas foram adotados como valores oficiais de AER dos solos estudados. Também foi proposto neste trabalho um novo critério de análise baseado nos resultados que utilizam como referência os métodos do AV e da TC, simultaneamente, a partir do qual foi possível determinar que as áreas de tamanho 432,0 mm² e 349,7 mm², respectivamente, fornecem valores de densidade confiáveis para os solos LVA e NV.
5

Infiltração da água em amostras de solo indeformadas e remodeladas em colunas utilizando modelos determinísticos / Infiltration of water in undisturbed and remodeling soil samples in columns using deterministic models

Oliveira, Verena Benício de 11 October 2018 (has links)
Define-se infiltração da água no solo como a entrada da água através da superfície do solo. O processo de infiltração separa, assim, quanto da precipitação pluvial, por exemplo, flui sobre a superfície do solo e quanto flui abaixo da superfície do solo, esta última tanto vertical como horizontalmente. Diversos fatores interferem neste processo, podendo-se destacar aqueles relacionados ao tipo de solo e declividade do terreno e às características do solo e da cobertura vegetal, bem como aquelas relacionadas à precipitação. São conhecidas diversas equações de infiltração, propostas para expressar a lei da infiltração da água em solos, que é o gráfico da taxa de infiltração da água com o tempo. São equações desenvolvidas empiricamente ou a partir de considerações físicas e aplicam-se somente a solos homogêneos e que permanecem homogêneos durante o processo. Dados da literatura têm mostrado que para nossos solos o avanço da frente de molhamento no processo de infiltração vertical também é proporcional à raiz quadrada do tempo, como a solução da equação de Richards obtida por Philip para a infiltração horizontal, porém com uma velocidade maior. Dado este fato, levanta-se a hipótese de utilizar a equação proposta por Philip para a infiltração na direção horizontal também para a direção vertical, em colunas com amostra de solo indeformada e com amostra de solo homogeneamente remodelada. Este trabalho trata do processo da infiltração de água no solo, especificamente a vertical descendente. Pretendeu-se avaliar as equações clássicas da lei da infiltração em amostras homogêneas de três solos estruturalmente distintos com estrutura deformada e indeformada. O experimento foi conduzido em latoratório, em nove colunas com amostras de três solos com características distintas, sendo um Cambissolo Háplico, um Latossolo Vermelho Amarelo distrófico e um Nitossolo Vermelho eutroférrico. As curvas da taxa de infiltração foram determinadas em laboratório e o conteúdo de água foi determinado pela técnica da atenuação gama. A equação proposta por Kostiakov para a lei da infiltração ajustou-se muito bem (máximo R2 para todos os solos, com exceção da coluna indeformada do Nitossolo) por praticamente coincidir com a equação de ajuste estatistico dos dados. Já o mesmo não ocorreu com a equação proposta por Horton para a qual os coeficientes de determinação variaram de 0,528 a 0,898 (sem considerer a amostra do Nitossolo indeformada). Com relação ao modelo de Green & Ampt que, ao contrário das equações de Kostiakov e Horton que são modelos empíricos, pode-se dizer tratar-se de um modelo semi-analítico, os ajustes dos dados também não foram muito bons (R2 variando de 0,802 a 0,898, sem considerer a amostra do Nitossolo indeformada). O modelo quase todo analítico de Philip, baseado na solução da equação de Richards para a direção horizontal, ajustou-se muito bem aos dados desta pesquisa que foi desenvolvida para a direção vertical descendente, visto que o gráfico da posição de frente de molhamento em relação a fonte de água em função da raiz quadrada do tempo de infiltração resultou numa linha reta com alto coeficiente de determinação para todas as amostras (R2 maior que 0,99 para as deformadas e R2 maior que 0,95 para as deformadas). Todos os modelos apresentaram um ajuste ruim (R2 menor que 0,1) para a coluna indeformada do solo 3 (Nitossolo). Provavelmente devido à presença de bioporo no interior da coluna, com fluxo preferencial da água ou também ao processo de amostragem que é muito dificuldato devido a forte estruturação deste solo. / Soil water infiltration is defined as the entry of water through the soil surface. The infiltration process thus separates how much of the rainfall, for example, flows over the soil surface and how much it flows below the surface of the soil, the latter both vertically and horizontally. Several factors interfere in this process, being possible to highlight those related to the type of soil and slope of the terrain and to the characteristics of the soil and vegetation cover, as well as those related to precipitation. Several infiltration equations are known, proposed to express the law of water infiltration in soils, which is the graph of the infiltration rate of water as a function of time. They are equations developed empirically or from physical considerations and apply only to homogeneous soils that remain homogeneous during the process. Literature data have shown that for our soils the advance of the wetting front in the vertical infiltration process is also proportional to the square root of the time, as the solution of the Richards equation obtained by Philip for horizontal infiltration, but with a higher velocity. Given this fact, the hypothesis is proposed to use the equation proposed by Philip for the infiltration in the horizontal direction also for the vertical direction, in columns with undisturbed soil sample and with homogeneously remodeled soil sample. This work deals especifically with the process of vertical descending soil water infiltration. It was intended to evaluate the classical equations of the infiltration law in homogeneous samples of three structurally distinct soils with disturbed and undisturbed structure. The experiment was carried out in a laboratory, in nine columns with three soils distinct characteristics, being a Haplic Cambisol, a Dystrophic Yellow Red Latosol and an eutrophic Red Nitosol. The infiltration rate curves were determined in the laboratory and the water content was determined by the gamma ray attenuation technique. The equation proposed by Kostiakov for the infiltration law adjusted very well (maximum R2 for all soils, except for the undisturbed Nitosol column) since it practically coincide with the equation of statistical fit of the data. The same did not occur with the equation proposed by Horton for which the coefficients of determination ranged from 0,528 to 0.898 (not considering the undisturbed column of Nitosol. In relation to the Green & Ampt model, unlike the Kostiakov and Horton equations that are empirical models, it can be said that it is a semi-analytical model, the data adjustments were also not good changing from 0,802 to 0,848 also not considering the undisturbed Nitosol. Philip\'s almost all-analytical model, based on the solution of the Richards equation for the horizontal direction, fitted very well the data from this work that were conducted in the downward vertical direction, since the graph of the wet facing front position the water source as a function of the square root of the infiltration time resulted in a straight line with a high coefficient of determination for all samples (R2 greater than 0.99 for the deformed and R2 greater than 0.95 for the deformed ones). All models presented a poor fit (R2 less than 0.01) for the undisturbed soil 3 column (Nitosol). Probably due to the presence of biopore inside the column, with preferential flow of water or to the sampling process that is very difficult due to the strong structure of this soil.

Page generated in 0.0756 seconds