• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • 41
  • 19
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 109
  • 109
  • 109
  • 44
  • 44
  • 43
  • 37
  • 37
  • 36
  • 32
  • 22
  • 19
  • 17
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Graphite filter atomizer in atomic absorption spectrometry

Katskov, DA 07 December 2006 (has links)
Graphite filter atomizers (GFA) for electrothermal atomic absorption spectrometry (ETAAS) show substantial advantages over commonly employed electrothermal vaporizers and atomizers, tube and platform furnaces, for direct determination of high and medium volatility elements in matrices associated with strong spectral and chemical interferences. Two factors provide lower limits of detection and shorter determination cycles with the GFA: the vaporization area in the GFA is separated from the absorption volume by a porous graphite partition; the sample is distributed over a large surface of a collector in the vaporization area. These factors convert the GFA into an efficient chemical reactor. The research concerning the GFA concept, technique and analytical methodology, carried out mainly in the author's laboratory in Russia and South Africa, is reviewed. Examples of analytical applications of the GFA in AAS for analysis of organic liquids and slurries, bio-samples and food products are given. Future prospects for the GFA are discussed in connection with analyses by fast multi-element AAS.
2

Determinação simultânia de Cd/Pb em cimento usando TI como padrão interno e de Cr/Mn em alumina por espectrometria de absorção atômica com amostragem de suspensão / Simultaneous determination of Cd/Pb in cement using Tl as internal standard and Cr/Mn in alumina by atomic absorption spectrometry with slurry sampling

Souza, Alexandre Luiz de 18 September 2007 (has links)
O objetivo desse trabalho foi o desenvolvimento de métodos analíticos para a determinação simultânea de Cd/Pb em cimento e Cr/Mn em alumina por espectrometria de absorção atômica com atomização eletrotérmica (SIMAAS) e amostragem de suspensão. Considerando os erros de amostragem de suspensão e as condições compromissadas impostas para a determinação simultânea, foi também objetivo do trabalho estudar a aplicação de padrão interno para corrigir erros sistemático e aleatório. A viabilidade de se usar o Tl como padrão interno foi explorada na determinação de Cd e Pb em cimento. O uso do padrão interno se baseou na hipótese de que o elemento Tl deveria adsorver quantitativamente sobre as partículas do material em suspensão. Foi feito o estudo térmico dos elementos Cd, Pb e Tl em soluções aquosas e suspensões, na presença e ausência de diferentes modificadores químicos. O melhor modificador químico (5 µg Pd + 3 µg Mg) foi escolhido com base nos gráficos de correlação. As melhores temperaturas de pirólise e atomização para a determinação simultânea de Cd e Pb foram 600°C e 2000°C, respectivamente. A preparação das amostras foi feita com suspensões contendo 30 µg L-1 de Tl em 0,1 % (v v-1) de HNO3 + 0,025 % (m v-1) de Triton X-100. A avaliação da exatidão foi feita com a determinação de Cd e Pb em cimento de construção civil e dentário com análise de solução e análise de materiais de referência de sedimento marinho (MESS1 e BCSS 1) e de rio (Buffalo River, IEAEA 356). Os resultados foram concordantes em um nível de confiança de 95% (teste t-student). Os limites de detecção (LD) obtidos foram 0,14 µg L-1 (1,4pg) para o Cd e de 1,2 µg L-1 (12 pg) para Pb. As massas características foram 1,2 pg e 25 pg para Cd e Pb, respectivamente. Na determinação simultânea de Cr e Mn em alumina não foi utilizado padrão interno. O estudo envolveu a obtenção de curvas de pirólise e atomização em presença de diferentes modificadores. Estudos de interferência mostraram que 100 mg L-1 de Al provocaram aumento nos sinais analíticos dos elementos que foi eliminado com o modificador químico NaOH (0,2 mol L-1) + HF (0,4 mol L-1) combinado com 350 µg de Nb. Nessa condição as temperaturas de pirólise e atomização foram 1400°C e 2400°C, respectivamente. As suspensões de alumina foram preparadas em 2 % (v v-1) HNO3. A avaliação da exatidão foi feita com a determinação de Cr e Mn em material de referência de alumina (Alumina Reduction Grade - 699) e os resultados foram concordantes em um nível de confiança de 95% (teste t-student). Os limites de detecção (LD), estimados a partir da variabilidade de 20 medidas consecutivas de uma solução contendo 2 % (v v-1) HNO3 foram 0,11 µg L-1 (2,2 pg) para Cr e 0,17 µg L-1 (3,5 pg) para o Mn. As massas características foram 10 pg e 1,3 pg para Cr e Mn, respectivamente. / The aim of this work was the development of analytical methods for the simultaneous determination of Cd/Pb in cement and Cr/Mn in alumina by electrothermal atomic absorption spectrometry (SIMAAS) and slurry sampling. Considering the errors of slurry sampling and the imposed compromissed conditions for the simultaneous determination, it was also the aiming of this work to study the application of internal standard for the sistematic and random errors correction. The viability of using Tl as internal standard was investigated for Cd and Pb determination in cement. The internal standard aplicability was based on the hypothesis of the element Tl would have to adsorver quantitatively on the particles of the material in suspension. The thermal behaviour of Cd, Pb and Tl in aqueous solutions and suspensions was obtained in presence and absence of different chemical modifiers. The best chemical modifier (5 mg Pd + 3 mg Mg) was chosen based on correlation graphs. The pyrolysis and atomization temperatures for the simultaneous determination of Pb were 600°C and 2000°C, respectively. The sample the preparation was made with 30 mg L-1 of Tl in 0,1% (v v-1) of HNO3 + 0.025% (m v-1 of Triton X-100. The evaluation of the accuracy was made with the determination of Cd and Pb in cement, microwave extraction in acid media and analysis of marine sediment reference materials (MESS1 and BCSS 1) and river sediment (Buffalo River, IEAEA 356). The results are concordant at 95% of confidence level using Studen\'s t-test. The detention limits (LD) was 0.14 µg L-1 (1.4 pg) for Cd and 1.2 µg L-1(12 pg) for Pb. The characteristic masses were 1.2 pg and 25 pg for Cd and Pb, respectively. The simultaneous determination of Cr and Mn in alumina was done without internal standard. Pyrolysis and atomization temperaturas were obtained in presence of different modifiers. Studies of interference shown that 100 mg L-1 of Al provoked increase in the analytical signals of Cr and Mn that was eliminated with the chemical modifier NaOH (0,2 mol L-1) + HF (0,4 mol L-1) combined with 350 mg of Nb as permanent chemical modifier. In this condition pyrolysis and atomization temperatures were 1400 °C and 2400 °C, respectively. The alumina suspensions were prepared in 2% (v v-1) HNO3. The evaluation of the accuracy was made with the determination of Cr and Mn in alumina reference material (Reduction Alumina Grating - 699) and the results were concordant at 95 % of the confidence level using Student\'s t-test. The detention limits (LD) were 0.11 µg L-1 (2.2 pg) for Cr and 0.17 µg L-1 (3.5 pg) for Mn. The characteristic masses were 10 and 1.3 pg for Cr and Mn, respectively.
3

Determination of selenium in biological materials by flow injection hydride generation atomic absorption spectrometry (FI-HG-AAS) : applications /

Galgan, Vera, January 2007 (has links) (PDF)
Diss. (sammanfattning) Uppsala : Sveriges lantbruksuniversitet, 2007. / Härtill 4 uppsatser.
4

Determinação simultânia de Cd/Pb em cimento usando TI como padrão interno e de Cr/Mn em alumina por espectrometria de absorção atômica com amostragem de suspensão / Simultaneous determination of Cd/Pb in cement using Tl as internal standard and Cr/Mn in alumina by atomic absorption spectrometry with slurry sampling

Alexandre Luiz de Souza 18 September 2007 (has links)
O objetivo desse trabalho foi o desenvolvimento de métodos analíticos para a determinação simultânea de Cd/Pb em cimento e Cr/Mn em alumina por espectrometria de absorção atômica com atomização eletrotérmica (SIMAAS) e amostragem de suspensão. Considerando os erros de amostragem de suspensão e as condições compromissadas impostas para a determinação simultânea, foi também objetivo do trabalho estudar a aplicação de padrão interno para corrigir erros sistemático e aleatório. A viabilidade de se usar o Tl como padrão interno foi explorada na determinação de Cd e Pb em cimento. O uso do padrão interno se baseou na hipótese de que o elemento Tl deveria adsorver quantitativamente sobre as partículas do material em suspensão. Foi feito o estudo térmico dos elementos Cd, Pb e Tl em soluções aquosas e suspensões, na presença e ausência de diferentes modificadores químicos. O melhor modificador químico (5 µg Pd + 3 µg Mg) foi escolhido com base nos gráficos de correlação. As melhores temperaturas de pirólise e atomização para a determinação simultânea de Cd e Pb foram 600°C e 2000°C, respectivamente. A preparação das amostras foi feita com suspensões contendo 30 µg L-1 de Tl em 0,1 % (v v-1) de HNO3 + 0,025 % (m v-1) de Triton X-100. A avaliação da exatidão foi feita com a determinação de Cd e Pb em cimento de construção civil e dentário com análise de solução e análise de materiais de referência de sedimento marinho (MESS1 e BCSS 1) e de rio (Buffalo River, IEAEA 356). Os resultados foram concordantes em um nível de confiança de 95% (teste t-student). Os limites de detecção (LD) obtidos foram 0,14 µg L-1 (1,4pg) para o Cd e de 1,2 µg L-1 (12 pg) para Pb. As massas características foram 1,2 pg e 25 pg para Cd e Pb, respectivamente. Na determinação simultânea de Cr e Mn em alumina não foi utilizado padrão interno. O estudo envolveu a obtenção de curvas de pirólise e atomização em presença de diferentes modificadores. Estudos de interferência mostraram que 100 mg L-1 de Al provocaram aumento nos sinais analíticos dos elementos que foi eliminado com o modificador químico NaOH (0,2 mol L-1) + HF (0,4 mol L-1) combinado com 350 µg de Nb. Nessa condição as temperaturas de pirólise e atomização foram 1400°C e 2400°C, respectivamente. As suspensões de alumina foram preparadas em 2 % (v v-1) HNO3. A avaliação da exatidão foi feita com a determinação de Cr e Mn em material de referência de alumina (Alumina Reduction Grade - 699) e os resultados foram concordantes em um nível de confiança de 95% (teste t-student). Os limites de detecção (LD), estimados a partir da variabilidade de 20 medidas consecutivas de uma solução contendo 2 % (v v-1) HNO3 foram 0,11 µg L-1 (2,2 pg) para Cr e 0,17 µg L-1 (3,5 pg) para o Mn. As massas características foram 10 pg e 1,3 pg para Cr e Mn, respectivamente. / The aim of this work was the development of analytical methods for the simultaneous determination of Cd/Pb in cement and Cr/Mn in alumina by electrothermal atomic absorption spectrometry (SIMAAS) and slurry sampling. Considering the errors of slurry sampling and the imposed compromissed conditions for the simultaneous determination, it was also the aiming of this work to study the application of internal standard for the sistematic and random errors correction. The viability of using Tl as internal standard was investigated for Cd and Pb determination in cement. The internal standard aplicability was based on the hypothesis of the element Tl would have to adsorver quantitatively on the particles of the material in suspension. The thermal behaviour of Cd, Pb and Tl in aqueous solutions and suspensions was obtained in presence and absence of different chemical modifiers. The best chemical modifier (5 mg Pd + 3 mg Mg) was chosen based on correlation graphs. The pyrolysis and atomization temperatures for the simultaneous determination of Pb were 600°C and 2000°C, respectively. The sample the preparation was made with 30 mg L-1 of Tl in 0,1% (v v-1) of HNO3 + 0.025% (m v-1 of Triton X-100. The evaluation of the accuracy was made with the determination of Cd and Pb in cement, microwave extraction in acid media and analysis of marine sediment reference materials (MESS1 and BCSS 1) and river sediment (Buffalo River, IEAEA 356). The results are concordant at 95% of confidence level using Studen\'s t-test. The detention limits (LD) was 0.14 µg L-1 (1.4 pg) for Cd and 1.2 µg L-1(12 pg) for Pb. The characteristic masses were 1.2 pg and 25 pg for Cd and Pb, respectively. The simultaneous determination of Cr and Mn in alumina was done without internal standard. Pyrolysis and atomization temperaturas were obtained in presence of different modifiers. Studies of interference shown that 100 mg L-1 of Al provoked increase in the analytical signals of Cr and Mn that was eliminated with the chemical modifier NaOH (0,2 mol L-1) + HF (0,4 mol L-1) combined with 350 mg of Nb as permanent chemical modifier. In this condition pyrolysis and atomization temperatures were 1400 °C and 2400 °C, respectively. The alumina suspensions were prepared in 2% (v v-1) HNO3. The evaluation of the accuracy was made with the determination of Cr and Mn in alumina reference material (Reduction Alumina Grating - 699) and the results were concordant at 95 % of the confidence level using Student\'s t-test. The detention limits (LD) were 0.11 µg L-1 (2.2 pg) for Cr and 0.17 µg L-1 (3.5 pg) for Mn. The characteristic masses were 10 and 1.3 pg for Cr and Mn, respectively.
5

Estudo da influência de processos de conservação na distribuição de espécies elementares em água de coco por espectrometria de absorção e emissão atômica / Study of influence of conservation processes in the distribution of elemental species in coconut water by atomic absorption spectrometry and optical emission spectrometry

Naozuka, Juliana 23 July 2004 (has links)
A água de coco é um isotônico natural, uma bebida pouco calórica e muito nutritiva, representando 1,4 % do mercado de refrigerantes e de isotônicos artificiais. Aliado ao crescente mercado interno e externo, surge os processos de conservação com o intuito de preservação da água de coco fora do fruto, facilitando a comercialização e aumentando o tempo de vida de prateleira. Considerando o pressuposto, esse trabalho teve como objetivo principal avaliar a influência dos processos de conservação, ultrafiltração, congelamento e pasteurização, na concentração de Al, Ca, Cu, Fe, K, Mg, Mn, Na, Se e Zn em água de coco. As determinações foram feitas por espectrometria de emissão óptica com plasma indutivamente acoplado e espectrometria de absorção atômica com atomização eletrotérmica. Investigação no sentido de determinar espécies livres de Se4+ e Se6+, em água de coco, por geração de hidretos e pré-concentração na superfície de um tubo de grafite modificada com Ir também foi objetivo desse trabalho. Os estudos foram realizados por meio das determinações das concentrações totais dos elementos e em diferentes frações (filtrado e resíduo), obtidas após ultrafiltração com membrana de celulose (0,100 e 0,025 µm). Em todos os processos de conservação estudados, exceto na ultrafiltração, as concentrações totais dos elementos de interesse foram preservadas. A ultrafiltração com filtro de 0,025 μm promoveu a retenção de uma quantidade significativa de Fe (30%) e Zn (50 %). A influência dos processos de conservação, com base na distribuição dos elementos de interesse, mostrou uma tendência de variação na distribuição de Cu, Fe e Zn na água de coco pasteurizada e em todos os elementos na congelada, sobretudo para aquelas com tempo de congelamento superior a 30 dias. A especiação de Se6+ e Se4+ foi feita após redução do Se6+ com 2,0 mol L-1 HCl + 1 mol L-1 KBr e aquecimento por microondas focalizadas em microfrascos, apresentando cerca de 95 % de eficiência na redução na ausência da amostra de água de coco. / The coconut water is a natural isotonic, nutritive and low caloric drink, corresponding to 1.4 % of the soft drink and artificial isotonic market store. The conservation processes of the coconut water appear in association to the expansion of the internal and external market, increasing the shelf-life of the product and its comercialization. The objective of this work was evaluate the influence of the conservation processes, such as, ultrafiltration, freezing and pasteurization based on the concentrations of Al, Ca, Cu, Fe, K, Mg, Mn, Na, Se and Zn in the coconut water. The determinations were done by inductively coupled plasma-optical emission spectrometry and electrothermal atomic absorption spectrometry. The investigation of free-species of Se4+ and Se6+, in coconut water, by hydride generation and pre-concentration on the modified graphite tube surface with Ir was also the aim of this project. The studies were carried out through the determinations of the total concentration of the interest elements and in different fractions (filtrate and residue), obtained after ultrafiltration with cellulose membrane filters (0.100 and 0.025 µm). In all processes of conservation studied, except the ultrafiltration, the total concentrations were preserved. The ultrafiltration with filters of 0.025 µm promoted the retention of significant concentration of Fe (30%) e Zn (50%). Considering the distribuituion of the interest elements, the influence of the conservation processes showed a tendency of the variation in the Cu, Fe and Zn distribuition for the pasteurized coconut water, and for all elements in the frozen, mainly for frozen samples storaged for more than 30 days. The speciation of Se4+ and Se6+ was carried out after reduction of Se6+ with 2 mol L-1 HCl + 1 mol L-1 KBr and using microvials heated in a focused microwave. The reduction efficiency of the Se6+ to Se4+ was 95 %, in absence of coconut water.
6

Desenvolvimento de métodos para determinações elementares em cimentos por espectrometria de absorção atômica com forno de grafite e amostragem direta de sólidos / Development of methods for elemental determination in cements by atomic absorption spectrometry with graphite furnace and direct solid sampling

Intima, Danielle Polidorio 18 September 2008 (has links)
O objetivo desse trabalho foi o desenvolvimento de métodos analíticos para a determinação de Cd, Pb, Cu, Ni, Co, Cr e Mn em cimentos Portland por espectrometria de absorção atômica com atomização em forno de grafite e amostragem direta de sólidos. Não foi necessário nenhum tipo de pré-tratamento das amostras, pois apresentaram tamanhos médios de partículas (~12 µm) adequados para aplicação em análise direta de sólidos. Os programas de aquecimento foram otimizados a partir da avaliação térmica de cada um dos elementos (curvas de pirólise e atomização), do uso de modificadores químicos e de matriz e da comparação de curvas de calibração em solução aquosa e na presença da amostra sólida. Todas as determinações dos elementos foram feitas usando curvas de calibração obtidas em meio de solução aquosa. Devido a alta concentração nas amostras, no caso do Cu, Ni, Co, Cr e Mn foi necessário o uso da correção de fundo por efeito Zeeman com 3 campos, aumentando a representatividade. Nessa condição, foi possível a pesagem de alíquotas da amostra de até 200 µg para análise. As melhores condições para as determinações de Cd e Pb foi com o uso do modificador químico 5 µg de Pd em 0,1 % m v-1 de Triton X-100. Nessa condição, as melhores temperaturas de pirólise e atomização foram 600°C e 2000°C para Cd e 900°C e 2100°C para Pb, respectivamente. As determinações de Cu e Ni foram possíveis sem o uso de modificador químico ou de matriz. As temperaturas de pirólise e atomização foram 1200°C e 2600°C, respectivamente, para os dois elementos. As determinações de Co, Cr e Mn foram realizadas com o uso de modificador de matriz (Na2CO3 + ZnO) que promoveu uma fusão in situ durante o programa de aquecimento. Nessas condições, as temperaturas de pirólise e atomização foram 1400 °C e 2600 °C, respectivamente. Os limites de detecção (3σ) para as determinações diretas em cimento Portland foram 0,011 µg g-1 para Cd, 0,28 µg g-1 para Pb, 0,25 µg g-1 para Cu, 0,24 µg g-1 para Ni, 0,11 µg g-1 para Co, 1,1 µg g-1 para Cr e 1,97 µg g-1 para Mn. As concentrações características foram 0,0098 µg g-1 para Cd, 0,21 µg g-1 para Pb, 0,17 µg g-1 para Cu, 0,24 µg g-1 para Ni, 0,068 µg g-1 para Co, 0,62 µg g-1 para Cr e 0,14 µg g-1 para Mn. As exatidões dos métodos foram avaliadas a partir da análise de materiais de referência de cimento Protland (NIST 1886a e 1889a) e de sedimentos marinhos (NBCC MESS-1 e NBCC BCSS-1). Todos os resultados concordaram a um nível de 95% de confiança, quando aplicado o teste t-Student. / The objective of this work was the development of analytical methods for the determination of Cd, Pb, Cu, Ni, Co, Cr e Mn in Portland cement by solid sampling graphite furnace atomic absorption spectrometry. It was not necessary any pretreatment of the samples, because the particles size (12 µm) were apropriated for direct solid analysis. The heating programs were optimized by thermal evaluation of each element (pyrolysis and atomization curves), using chemical and matrix modifiers and comparison of the calibration curves obtained in presence of aqueous solutions and solid samples. All determinations of the elements were performed against aqueous calibration curves. Due to the high concentration in the samples, for Cu, Ni, Co, Cr e Mn determinations were necessary 3-field Zeeman background correction, improving the representativity. Using this condition, it was possible weight aliquots of samples up to 200 µg. The best condition for Cd and Pb determinations was 5 µg of Pd in 0.1% m v-1 de Triton X-100 as chemical modifier. The pyrolysis and atomization temperatures were 600°C and 2000°C for Cd and 900°C and 2100°C for Pb, respectively. The determinations of Cu e Ni were possible without chemical modifier. The pyrolysis and atomization temperatures were 1200°C and 2600°C, respectively, for both elements. For the determinations of Co, Cr e Mn were used a matrix modifier (Na2CO3 + ZnO) for the in situ fusion, during the heating program. In this condition, the pyrolysis and atomization temperatures were 1400°C and 2600°C, respectively, for all elements. The detection limits (3σ) for the direct determination of Portland cement were 0.011 µg g-1 for Cd, 0.28 µg g-1 for Pb, 0.25 µg g-1 for Cu, 0.24 µg g-1 for Ni, 0.11 µg g-1 for Co, 1.1 µg g-1 for Cr and 1.97 µg g-1 for Mn. The characteristic concentrations were 0.0098 µg g-1 for Cd, 0.21 µg g-1 for Pb, 0.17 µg g-1 for Cu, 0.24 µg g-1 for Ni, 0.068 µg g-1 for Co, 0.62 µg g-1 for Cr and 0,14 µg g-1 for Mn. The accuracy of the methods was evaluated by reference materials of Portland cement (NIST 1886a and 1889a) and marine sediments (NBCC MESS-1 and NBCC BCSS-1) analysis. All results are in good agreement with the recommended concentration at 95 % (t-Student test) as confidence level.
7

Avaliação de indicadores biológicos de exposição para As, Be, Cd, Hg, Ni, e Pb em trabalhadores de incineradores de resíduos de serviços de saúde / Evaluation of biological indicators of expousure for As, Be, Cd, Hg, Ni and Pb in workers of medical wastes incineration

Pavesi, Thelma 28 August 2006 (has links)
Este trabalho avalia indicadores biológicos de exposição ocupacional de trabalhadores de incineradores de resíduos de serviços de saúde. Os elementos estudados são arsênio, berílio, cádmio, mercúrio, níquel (amostras de urina) e chumbo (amostras de sangue). Os índices obtidos são comparados com (a) os limites estabelecidos pela legislação brasileira, (b) os limites estabelecidos pela American Conference of Governmental Industrial Hygienists (ACGIH) e (c) com os mesmos índices medidos em outros trabalhadores das mesmas usinas trabalhando em diferentes áreas, funções e turnos. As determinações foram realizadas por espectrometria de absorção atômica: por forno de grafite para berílio, cádmio, níquel e chumbo; através da geração de hidreto para arsênio; por geração de vapor frio para mercúrio. Os métodos foram otimizados e validados através de material certificado e ensaios de recuperação. As amostras foram coletadas em 5 dias consecutivos, antes e após cada jornada de trabalho. As médias de concentração para os indicadores biológicos foram inferiores aos limites para exposição ocupacional para os agentes estudados. No caso do arsênio, entretanto, alguns indivíduos apresentaram valores de concentração acima do estabelecido pela legislação brasileira. / The biological occupational exposure indices of workers in medical waste incineration plants is evaluated. Arsenic, beryllium, cadmium, mercury and nickel (urine samples) and lead (blood samples) are studied. The measured indices are compared with (a) the limits imposed by Brazilian law, (b) limits established by American Conference of Industrial Governmental Hygienists and (c) the same indices measured for co-workers in different workplaces, activities and workshifts. The measurements have been carried through atomic absorption spectrometry: by graphite furnace for of beryllium, cadmium, nickel and lead; using the hidride generation for arsenic; and by cold vapor generation for Hg. The employed methods have been optimized and validated through certified samples and recovery essays. The samples were collected in 5 consecutive workdays, before and after each working shift. The measured indices are found to be below their respective occupational exposure limits when the average for each group of workers is taken. In the case of the arsenic, however, some individual workers have shown levels above the limits imposed by Brazilian law.
8

\"Avaliação da espectrometria de absorção atômica com atomização eletrotérmica em filamento de tungstênio para determinação de alumínio\" / \"Evaluation of tungsten coil electrothermal atomic absorption spectrometry for aluminium determination\"

Godoi, Quienly 27 October 2006 (has links)
Este trabalho teve como objetivo avaliar o filamento de tungstênio de 150 W (OSRAM) como atomizador eletrotérmico para determinação de alumínio em amostras de águas, incluindo um estudo sistemático sobre o seu comportamento eletrotérmico na presença de até 1000 mg l-1 de sódio, potássio, cálcio, magnésio e/ou da mistura destes elementos. Alguns parâmetros, como comprimento de onda, corrente da lâmpada de catodo oco, altura de observação e temperatura de atomização do alumínio foram avaliados visando à melhoria da qualidade dos resultados e do limite de detecção. Após uma primeira avaliação, fixaram-se o comprimento de onda em 309,3 nm e a corrente da lâmpada de catodo oco em 10 mA, elegendo-se altura de observação de 1,5 mm e temperatura de atomização de 2860 oC (13,0 V). No programa de aquecimento usado no desenvolvimento deste trabalho adotou-se rampa invertida de voltagem variando entre 0,65 a 0,30 V durante 50 s para secagem de 10 µl, 2,8 V durante 10 s para pirólise e 13,0 V durante 1 s para atomização. As soluções usadas no desenvolvimento deste trabalho formam preparadas, em sua maioria, em meio 0,1 % v/v HNO3. A avaliação dos potenciais interferentes Na, K, Ca, Mg e a mistura desses elementos foi realizada nas alturas de observação de 0,0 a 2,0 mm e nas composições do gás de proteção de 90% Ar/10% H2, 80% Ar/20% H2, 65% Ar/35% H2. Pode-se inferir que o aumento do hidrogênio na composição do gás de proteção não acarretou melhora significativa na ação dos interferentes na atomização do alumínio. Não foram observadas interferências significativas em até 1000 mg l-1 Na e K na atomização de 100 µg l-1 Al na altura de observação de 0,0 mm. Na mesma condição de altura de observação, a mistura dos interferentes não afetou significativamente a atomização do alumínio. Observaram-se interferências em torno de 40 % na atomização de 100 µg l-1 Al em 0,1 % v/v HNO3 na altura de observação de 0,0 mm na presença de até 100 mg l-1 de Ca e Mg. Nessa mesma condição, mas com a mistura 65 % Ar/35 % H2, a supressão do sinal de absorbância de alumínio foi da ordem 90%. Os resultados obtidos na determinação de alumínio em amostras de água foram obtidos nas condições anteriormente citadas, utilizando gás de proteção 90% Ar/ 10% H2. Nestas condições, o limite de detecção foi de 2,3 µg l-1 Al e a massa característica de 69 pg Al. Os resultados encontrados foram satisfatórios e concordantes com aqueles encontrados quando se utilizou o forno de grafite como método de comparação. Aproximadamente 500 queimas foram feitas com um único filamento de tungstênio. / The aim of this paper was to evaluate the 150 W (OSRAM) tungsten coil as electrothermal atomizer in order to determine aluminum in water samples as well as a systematic study of its electrothermal behavior in the presence of up to 1000 mg l-1 of sodium, potassium, calcium, magnesium and/or of mixture of these elements. Some parameters, such as wavelength, hollow cathode lamp current, observation height and atomization temperature were evaluated in order to improve the quality of results and the detection limit. After a first evaluation, measurements were always carried out at 309,3 nm as well as the hollow cathode lamp current at 10 mA, and it was adopted an observation height of 1,5 mm and atomization temperature at 2860 oC (13,0 V). In the heating program defined experimentally, the inverted voltage ramp was adopted for drying 10 μl of sample solution by varying the applied voltage from 0,65 to 0,30 V during 50 s, with further application of 2,8 V for 10 s in the pyrolysis step and 13,0 V for 1 s in the atomization step. Most solutions were prepared in 0,1% v/v HNO3. The evaluation of the potential interfering elements such as Na, K, Ca, Mg an the mixture of these elements, was carried out in observations heights from 0,0 to 2,0 mm at different gas compositions: 90% Ar/ 10% H2 , 80 % Ar/ 20% H2 and 65 % Ar/ 35% H2. It can be inferred that the hydrogen increase in the protection gas did not change the interference behavior of the studied concomitants on aluminum atomization. Significant interferences were not observed up to 1000 mg l-1 of Na and K in the atomization of 100 μg l-1 Al when the optical beam was intercepting the atomizer (0,0 mm observation height). In the same condition, the mixture of the interfering species did not significantly affect the aluminum atomization. In addition, 100 mg l-1 of Ca and Mg depressed the absorbance of 100 μg l-1 Al in 0,1 % v/v HNO3 by approximately 40 %. When the atomization was made in the presence of 65 % Ar/ 35 % H2, the suppression of the aluminum absorbance signal was about 90 %. The results obtained in the determination of aluminum in water samples were achieved in the conditions previously mentioned, using protection gas of 90 % / 10 % H. In these conditions, the detection limit was 2,3 μg l-1 Al and the characteristic mass was 69 pg Al. The results were reasonable and in agreement with those found by atomic absorption with graphite furnace as a comparative method. Approximately 500 firings were made with a single tungsten coil.
9

Electrochhemical Hydride Generation And Tungsten Trap Atomic Absorption Spectrometry For Determination Of Antimony

Yildiran, Ahmet 01 December 2008 (has links) (PDF)
Electrochemical hydride generation is an alternative technique to the chemical hydride generation by NaBH4 which is widely used for atomic spectrometric determination of volatile elements such as As, Bi, Ge, Pb, Sb, Se, Sn and Te. The aim of this research has been to develop an analytical technique at the level of ng/L for determination of antimony by using a simple and inexpensive AA spectrometer and the other parts that can be built in any laboratory. Carbon rod and platinum foil were used as cathode and anode materials, respectively, for the generation of antimony hydride. Argon was used as the carrier gas. Zr coated W-coil was used for on-line preconcentration of generated hydrides. A new apparatus independent from quartz T-tube atomizer was constructed and used to contain the atom trap. Zr coated W-trap was heated to the collection temperature for trapping the analyte species generated electrochemically. For the revolatilization of the trapped species, the trap was further heated to the revolatilization temperature. Revolatilized species were transported to a flame-heated quartz tube atomizer where the analytical signal was recorded. Duringcollection and revolatilization steps hydrogen gas was introduced into the system to prevent the oxidation of atom trap. The experimental operation conditions for electrochemical hydride generation and atom trapping were optimized. 3&amp / #963 / limit of detections were found to be 0.012 ng/mL and 0.41 ng/mL with and without using trap, respectively. The trap has provided 34 fold sensitivity improvement as compared with the electrochemical hydride generation alone. The interferences of some hydride forming elements and some transition metals on electrochemical hydride generation with and without employing the trap were investigated. Analysis of standard reference material was performed to check the accuracy of the proposed method.
10

Inorganic Antimony Speciation Using Tungsten Coil Atom Trap And Hydride Generation Atomic Absorption Spectrometry

Akay, Pinar 01 February 2010 (has links) (PDF)
Antimony is a toxic element which is mostly found in two oxidation states (III and V) in environmental, biological and geological samples. Antimony may form various inorganic and organic compounds that exhibit differences in analytical behavior, toxicity and mobility / inorganic compounds of antimony are more toxic than organic forms and toxicity of Sb(III) has been shown to be 10 times higher than that of Sb(V). Therefore selective determination of Sb(III) and Sb(V) is required in environmental and biological samples. Hydride generation atomic absorption spectrometry is a sensitive, fast and economical technique for the determination of antimony at trace level. A possible non-chromatographic method for antimony speciation is hydride generation atomic absorption spectrometry that is based on the relatively slow kinetics of hydride formation from Sb(V). In this study, continuous flow hydride generation method for the determination of antimony was developed and hydride generation conditions were optimized. Analyte solution was prepared in 0.050 mol/L HCl and 1.2% (w/v) NaBH4 stabilized in 0.30% (w/v) NaOH was used as a reductant solution. Inorganic antimony speciation conditions were determined by continuous flow HGAAS system. For the pre-reduction of Sb(V) to Sb(III), 8.0% (w/v) potassium iodide (KI) and 0.10% (w/v) ascorbic acid were used. Further speciation study was also carried out using Ir coated W-coil Atom Trap Hydride Generation Atomic Absorption Spectrometry. Tungsten coil atom trap was used to enhance the sensitivity. Tungsten coil surface was treated with Ir and totally 250 &amp / #956 / g 1000 mg/L Ir stock solution was used for coating of tungsten coil. LOD and LOQ values were calculated as 152 pg/mL and 508 pg/mL according to 120 seconds trapping. 128 and 37 fold enhancement were obtained for 120 seconds collection with respect to W-coil-ETAAS and ETAAS, respectively.

Page generated in 0.1641 seconds