• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de tubo metalico como atomizador na tecnica de HG-AAS : analise de parametros analiticos e morfologicos / Evaluationof metallic tube as atomizer in the HG-AAS technique : analysis of analytical and morphological parameters

Klassen, Aline 08 January 2007 (has links)
Orientador: Marco Aurelio Zezzi Arruda / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-09T03:57:40Z (GMT). No. of bitstreams: 1 Klassen_Aline_M.pdf: 4690770 bytes, checksum: a9edf74063589d6c5e00414205c9b518 (MD5) Previous issue date: 2007 / Resumo: Nesta Dissertação foi avaliada a eficiência do atomizador metálico (liga INCONEL600®) na técnica de HG-AAS (do inglês, hydride generation atomic absorption spectrometry) . A dissertação está dividida em três Capítulos sendo cada um referente ao desenvolvimento da metodologia para determinação de As, Bi e Se, respectivamente. Foram avaliadas variáveis físicas e químicas por meio do uso de soluções de referência de 50 mg L para As e Bi, e de 400 mg L para Se. Dentre estas variáveis podemos citar: concentração de ácido (exceto no caso do Se, em que a concentração foi mantida em 7 mol L), de NaBH4 e de NaOH, comprimento do reator, alça de amostragem, vazão de solução carregadora, vazão de gás de arraste, diâmetro interno do capilar cerâmico entre outros. Alguns parâmetros analíticos foram obtidos, respectivamente para As, Bi e Se: limite de detecção (LD), ( 2,3; 0,7; 1,8 mg L), desvio padrão relativo (RSD), (5,8; 2,7; 10%) e coeficiente de regressão (R), (0,9978; 0,9997; 0,9974). O desvio padrão relativo do método foi baseado nas réplicas das amostras. Posteriormente, foi realizado um estudo de possíveis concomitantes na determinação de As, Bi e Se. As proporções de analito:concomitante foram baseadas no universo das amostras usadas nesta dissertação para os elementos As e Se. Com esse estudo, pôde ser verificado que a seletividade foi grandemente afetada pela presença de Cu, Fe e Ni, para a determinação de As e Bi, no entanto, para a determinação de Se, os elementos Cu, Bi e As interferiram. Os testes de exatidão dos métodos propostos foram averiguados por meio do uso de materiais de referência certificados de amostras ambientais, bem como de interesse medicinal. Os valores encontrados foram concordantes com os valores certificados, segundo um intervalo de confiança de 95% de acordo com o teste t. Após o término do desenvolvimento de cada metodologia, os atomizadores foram cortados em diferentes pontos e foram obtidas algumas micrografias, bem como a composição da liga, por meio do detector de Raios-X. Com esse estudo foi possível inferir algumas explicações sobre a necessidade da injeção de um padrão concentrado no sistema para determinação de arsênio, bem como a descoberta de nanotubos de carbono na superfície do atomizador empregado na metodologia para determinação de bismuto. A existência de nanotubos de carbono foi confirmada por meio da técnica de TEM. Esse resultado é interessante, uma vez que o custo dos nanotubos é elevado e o mesmo tem sido empregado em diversas aplicações na Ciência. / Abstract: In this work, the metal atomizer (alloy INCONEL600®) efficiency in the HG-AAS technique was evaluated. It was divided into three Chapters, each one referring to the development of methodologies for arsenic, bismuth and selenium. Physical and chemical variables were evaluated using reference solutions of 50 mg L for As and Bi, and 400 mg L for Se. The evaluated variables were: acid, NaBH4 and NaOH concentration, length of the reaction coil, injected volume, carrier flow rate, argon carrier flow rate, inner diameter of the capillary, among others. The acid concentration for selenium determination was fixed at 7 mol L. After methodology optimization, some analytical parameters were obtained, respectively for As, Bi and Se: limit of detection - LOD, 2.3, 0.7 and 1.8 mg L, relative standard deviation - RSD, 5.8, 2.7 and 10% and regression coefficient - R, 0.9978, 0.9997 and 0.9974. The RSD of the method was based on As, Bi and Se analytical repeatability from samples. Then, a concomitant study was carried out for As, Bi and Se determination. The analyte:concomitant proportion for As and Se was based on those samples used in this work. This result showed that the presence of Cu, Fe and Ni greatly affected the selectivity for As and Bi, as well as Cu, Bi and As can be considered potential concomitants for Se. Certified reference materiais as well as medical samples were used for checking the accuracy of the proposed methods. By analyzing the results using the t test, no statistical difference at the 95% confidence level was found. After finishing the development of the analytical procedure as well as its application to real samples, each metal atomizer used for each developed methodology was then cut in different parts and morphological as well as X-ray analysis were performed to evaluate the metal distribution on the atomizer. From this study, some explanation was made about the necessity of the standard solution injection into the system for As determination. Additionally, carbon nanotubes were also found in the atomizer surfaces when it was applied to Si determination. Its presence was confirmed by the transmission electronic microscopy technique. / Mestrado / Quimica Analitica / Mestre em Química
2

Emprego da técnica MF-HG-AAS na determinação de estanho : análise de parâmetros analíticos e morfológicos do atomizador metálico / Employment of a metallic furnace hydride generation atomic absorption spectrometry (MF-HG-AAS) method for tin determination : analytical and morphological parameters analysis of metallic atomizer

Galazzi, Rodrigo Moretto, 1988- 22 August 2018 (has links)
Orientador: Marco Aurélio Zezzi Arruda / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-22T10:57:39Z (GMT). No. of bitstreams: 1 Galazzi_RodrigoMoretto_M.pdf: 2262907 bytes, checksum: fb6e92051f6858cd925c525071ce6540 (MD5) Previous issue date: 2013 / Resumo: Nessa dissertação, otimizou-se um método para a determinação de estanho (Sn) em amostras biológicas empregando a técnica de Espectrometria de Absorção Atômica por Geração de Hidretos e Forno Metálico (MF-HG-AAS, do inglês Metallic Furnace Hydride Generation Atomic Absorption Spectrometry). Foram avaliadas algumas variáveis químicas como o tipo e concentração do carregador/diluente da solução padrão, concentração do redutor tetraidridoborato (-1) de sódio (THB) e concentração de hidróxido de sódio, bem como variáveis físicas do sistema dentre elas a vazão de carregador, proporção de acetileno:ar na chama, volume de solução injetado, vazão de argônio como gás de arraste, vazão de água no nebulizador e área total de furos no tubo metalico Inconel600®. Foi realizado um estudo do efeito de memória observado em condições de chama oxidante nas vazões de 1,5:9; 1,4:9; 1,3:9; 1,4:10; 1,4:8 e 1,5:11 L min de acetileno:ar, respectivamente. Em todas essas proporções de chama diferentes da otimizada (1,5:10 L min acetileno:ar) há efeito de memória, o que é extremamente indesejável. Após a otimização do sistema, foram realizados testes de exatidão e precisão do mesmo com os materiais PACS-2 (sedimento) e SRM 1643e (amostra de água) em que, em ambos, foi possível recuperar o Sn adicionado obtendo limites de detecção (LD) de 7,1 mg kg e 7,6 mg L, respectivamente. Um estudo com concomitantes foi realizado para avaliar se algum dos elementos em questão poderia interferir na determinação do Sn. Foram estudados como possíveis concomitantes o cobre, chumbo e zinco em três níveis diferentes. Somente o cobre, nas razões de 1:10 e 1:20 (Sn:concomitante), interferiu na detecção de Sn. Por fim, a morfologia do atomizador foi avaliada por meio da técnica de Microscopia Eletrônica de Varredura (SEM, do inglês Scanning Electron Microscopy). Mesmo após a realização de todos os experimentos envolvendo a otimização do sistema e análise das amostras, os principais constituintes do tubo metálico Inconel600® (ferro, níquel e cromo) permaneceram homogeneamente distribuídos, indicando que esses metais podem não participar da rota de atomização do Sn. Além disso, houve formação de óxidos no atomizador que, juntamente com o uso de uma chama oxidante, sugerem uma rota de atomização do Sn via formação de óxidos. Considerando os LD, bem como a exatidão e precisão por meio da recuperação de Sn obtida nas amostras, constata-se a potencialidade da MF-HG-AAS frente a outras técnicas empregadas na determinação de Sn / Abstract: In this work, a Metallic Furnace Hydride Generation Atomic Absorption Spectrometry (MF-HG-AAS) was optimized for tin (Sn) determination in biological samples. Chemical variables, such as the type and carrier concentration, the sodium tetrahydrideborate (-1) (THB), and the sodium hydroxide concentration, as well as physical variables, such as carrier flow-rate, ratio of acetylene and air in the flame, injection volume, argon flow-rate as carrier of stannane, water flow-rate in nebulizer and total hole area of a Inconel600® metallic furnace were evaluated. A study of a memory effect observed in oxidant flame conditions such as 1.5:9; 1.4:9; 1.3:9; 1.4:10; 1.4:8 e 1.5:11 L minof acetylene:air, respectively, was realized. In any other flame flow-rate, which the optimized flame ratio (1.5:10 L min acetylene:air) was observed a memory effect, which is very undesirable. After optimizing of the system, test of accuracy and precision were realized with the PACS-2 (sediment) and SRM 1643e (water sample) materials wherein, in both, a recovery of the Sn added to the samples was possible with limits of detection (LOD) as 7,1 mg kg and 7,6 mg L, respectively. A concomitant study was carried out for checking the interferences in the Sn determination. Copper, lead and zinc at three different levels were studied as possible concomitants. Only copper, at 1:10 and 1:20 (Sn:concomitant) ratios interfered in the determination of Sn. Finally, the morphology of the atomizer employed was evaluated through Scanning Electron Microscopy (SEM) technique. Even after carrying out all experiments involved in the optimization of the system and in the sample analysis, the main constituents of Inconel600® metallic furnace (iron, nickel and chromium) remained homogeneously distributed, indicating which these elements may not participate of the Sn atomization route. Moreover, the oxide formation in the atomizer was detected, which, together with an oxidant flame used, suggests the Sn atomization route via oxides formation. Considering the LOD, as well the accuracy and precision through the Sn recovery in the samples, the MF-HG-AAS potentially is well pointed out when it is compared to other techniques employed for Sn determination / Mestrado / Quimica Analitica / Mestre em Química

Page generated in 0.0767 seconds