• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação histológica e histomorfométrica do reparo ósseo em tíbias osteotomizadas de ratos (Rattus novergicus albinus) frente à ausência de carga e tratamento com ultrassom

Meira, Priscila Silvério [UNESP] 10 December 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-12-10Bitstream added on 2014-06-13T18:55:54Z : No. of bitstreams: 1 meira_ps_me_araca.pdf: 865581 bytes, checksum: 9d2686f43c3dd346235734077461d701 (MD5) / A resposta do metabolismo ósseo está diretamente relacionada a fatores hormonais e ao estímulo mecânico que o osso está exposto. A energia ultrassônica na cicatrização do reparo ósseo têm se mostrado de fundamental importância para o estímulo e melhora na qualidade do tecido neoformado durante o processo de cicatrização óssea. O objetivo deste estudo foi analisar a ação do ultrassom de baixa intensidade no reparo ósseo de tíbias osteotomizadas de ratos submetidos à suspensão pela cauda, por meio das análises histológica e histomorfométrica. Dezoito Rattus novergicus albinus, Wistar adultos foram divididos em três grupos, (G1, G2 e G3), dispostos da seguinte maneira: G1 (n=6), que permaneceram livres por um período de 15 dias; G2 (n=5), suspenso pela cauda por um período de 15 dias e G3 (n=7), suspensos pela cauda por um período de 36 dias. Todos os animais foram submetidos à cirurgia para confecção do defeito ósseo experimental na região medial da diáfise, em ambas as tíbias. A tíbia direita foi tratada com ultrassom pulsado (frequência de 1,5 MHz, ciclo 1:4, 30mW/cm2), por 12 sessões de 20 minutos, e o membro contralateral foi o controle. As amostras das tíbias foram submetidas à análise histológica, às cegas, com microscopia de luz comum e a análise histomorfométrica, pelo software específico Image-pro 6.1. As médias percentuais de neoformação óssea foram submetidas à análise de variância em parcela subdividida e teste de comparação múltipla “Student-Newman- Keuls” (SNK), com nível de significância de 5%. Os valores das médias e desvios padrão, da porcentagem de osso neoformado para os grupos, demonstraram uma menor quantidade no reparo ósseo do G1t(13,62  4,88) - G1c (8,68  4,16) quando comparado aos grupos G2t (27,17  11,36) - G2c (10,10  7,90) e G3t (23,19  5,61) - G3c (15,74  7,08). No entanto... / The response of bone metabolism is directly related to hormonal factors and mechanical stimulation to the bone is exposed. The ultrasonic energy on the healing of bone repair have been shown to be of fundamental importance to promoting and improving the quality of newly formed tissue during the bone healing process. The objective of this study was to analyze the action of low-intensity ultrasound on bone healing of tibial osteotomy in rats subjected to tail suspension, by means of histological and histomorphometric analysis. Eighteen Rattus novergicus Albinus, Wistar rats were divided into three groups (G1, G2 and G3), arranged as follows: G1 (n = 6), who remained free for a period of 15 days, G2 (n = 5), suspended by the tail for a period of 15 days and G3 (n = 7), suspended by the tail for a period of 36 days. All animals underwent surgery to make the experimental bone defect on the medial aspect of the diaphysis in both tibias. The right tibia was treated with pulsed ultrasound (frequency of 1,5 MHz, duty cycle 1:4, 30mW/cm2), for 12 sessions of 20 minutes, and the contralateral limb was the control. Samples of tibia were subjected to histological analysis, blindly, with common light microscopy and histomorphometric analysis by specific software Image-Pro 6.1. The average percentage of new bone formation were subjected to analysis of variance in a split plot test and multiple comparison Student-Newman-Keuls (SNK), with a significance level of 5%. The mean values and standard deviations of the percentage of newly formed bone for the groups showed a smaller amount in the healing of G1T (13,62  4,88) - G1C (8,68  4,16) in comparison with the G2T (27,17  11,36) - G2C (10,10  7,90) and G3t (23,19  5,61) - G3C (15,74  7,08). However, the mean values and standard deviations... (Complete abstract click electronic access below)
2

Efeito do ultra-som de baixa potência na reparação óssea em ratos sob ausência de carga: análise densitométrica e biomecânica

Coêlho, Juliana de Carvalho Apolinário [UNESP] 08 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-12-08Bitstream added on 2014-06-13T20:14:18Z : No. of bitstreams: 1 apolinario_jc_me_araca.pdf: 190197 bytes, checksum: 1aba6bb35b316b811a8b671145feab29 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A literatura apresenta que a resposta de reparo ósseo pode ser acentuada pela estimulação física, mecânica ou eletromagnética. Há evidências de que o ultra-som – US – de baixa potência pode acelerar a regeneração óssea. Este trabalho objetivou verificar o efeito do US no defeito ósseo, criado experimentalmente, em tíbias de ratos sob ausência de carga (suspenso pela cauda) por meio de análise densitométrica e biomecânica. Trinta Rattus novergicus albinus, Wistar, adultos, divididos em 3 grupos: G1 (n=10), não suspenso - experimento de 15 dias; G2 (n=10), suspenso pela cauda - experimento de 15 dias e, G3 (n=10), suspensos pela cauda, experimento de 36 dias. Os animais foram submetidos à osteotomia em ambas as tíbias e à aplicação do US (freqüência de 1,5 MHz, ciclo 1:4, 30mW/cm2) na direita (12 sessões de 20 minutos). O G3 somente foi osteotomizado após 21º dia de suspensão. Para análises densitométrica utilizou-se densitômetro DPXLunar ™, sistema digital Digora e o programa computacional Image J ; para ensaio mecânico usou máquina universal de ensaio EMIC . Os resultados do Conteúdo Mineral Ósseo (g), Área (cm²), Densidade Mineral Óssea (g/cm²) e da Densidade Óssea (mmAl) observadas nas tíbias, assim como a Força Máxima (N) e Rigidez (x103N/m) não demonstraram diferenças significantes (tratadas versus controle de cada grupo), possivelmente pelo menor tempo de tratamento com relação aos trabalhos encontrados na literatura. Concluindo que o Ultra-Som de baixa potência não acelerou o processo de consolidação óssea. / Literature shows that bone repair response can be accented by physical, mechanic or electromagnetic stimulation. There are evidences that low power ultrasound – US - can speed up bone regeneration. This work aimed at determining the effect of US in bone defects, experimentally created, in tibia from rats under load absence (suspended by the tail) by densitometric analysis and biomechanics. Thirty Rattus novergicus albinus, Wistar, adult, divided in 3 groups: G1 (n=10), not suspended – a 15 day experiment; G2 (n=10), suspended by the tail – a 15 day experiment and, G3 (n=10), suspended by the tail – a 36 day experiment. , The animals have been submitted to the osteotomy in both tibias and to the US application (1,5 MHz frequency, cycle 1:4, 30mW/cm2), on the right (twelve sessions of 20 minutes). G3 was only osteotomized after the 21st day of suspension. DPX-Lunar™ densitometer, Digora digital system and Image J computer program were used for densitometrical analysis; for the mechanical assay, the universal machine of EMIC assay was used. The results for Bone Mineral Content (g), Area (cm²), Bone Mineral Density (g/cm²) and Bone Density (mmAl) observed in tibias, as well as Maximum Power (N), and Rigidity (x103N/m) did not show any significant differences (treated versus control of each group), possibly due to shorter treatment time as regards the studies found in literature. Concluding that the low power ultrasound not accelerated the process of consolidating bone.

Page generated in 0.0802 seconds