Spelling suggestions: "subject:"béton renforce dde fibres."" "subject:"béton renforce dee fibres.""
11 |
Effets de défauts de coulage sur la micro-fissuration des dalles minces en béton fibré à ultrahaute performance - étude par stéréovision et corrélation d'images digitalesBaril, Marc-Antoine 22 May 2024 (has links)
Le béton fibré à ultrahaute performance (BFUP) est reconnu pour sa grande résistance en compression et sa grande ductilité. De plus, il est maintenant bien connu que le comportement du BFUP dépend grandement de l’orientation des fibres par rapport à la direction de sa sollicitation. Cependant, peu d’informations sont disponibles dans la littérature à propos de l’impact de la discontinuité locale des fibres causée par un défaut de coulage dans un mélange de BFUP. Dans ce mémoire de maîtrise, un protocole de laboratoire est développé afin de mesurer l’impact de la présence de défauts dans le béton fibré à ultrahaute performance. Ce protocole de laboratoire se base sur un système de mesures photogrammétriques de corrélation d’images digitales. Cette technique permet d’acquérir des mesures de déformations et de déplacements avec l’aide d’une paire de caméras numériques à haute résolution. Un post-traitement informatique des images prises lors de l’essai permet de récréer un modèle 3D de la surface de l’échantillon observé. Avec l’aide de cette nouvelle méthode de mesure, il est possible de présenter différents aspects du comportement non linéaire de ce matériel. Lors de ce projet, six dalles avec ou sans défaut ont été soumises à un effort flexionnel avec une charge ponctuelle. En développant un protocole de laboratoire adapté aux besoins de ce projet, la corrélation d’images numériques a permis d’obtenir des résultats très précis. Une attention particulière est portée sur l’impact des différents défauts sur le comportement mécanique global de la dalle et sur l’endommagement local lors de la fissuration. / Ultra-high performance fiber reinforced concrete (UHPFRC) is well known for its great compressive resistance and its ductility. Furthermore, it is also well known that UHPFRC strongly depends on fibers’ orientations relatively to the direction of stresses. However, little is documented in the literature about the impact of local fiber discontinuity caused by casting defect. In this MSc thesis, a laboratory protocol is developed in order to measure the impact of the presence of defects in a UHPFRC slab on the mechanical response. This protocol is based on a system of photogrammetric measurement by digital image correlation (DIC). This technique allows the precise measure of the deformation as well as the displacement with help of a pair of high resolution digital camera. A computer-based post treatment analysis of these pictures is used to create a 3D model of the observed sample surface. With this new analysis method, it is possible to present different aspect of the non-linear behavior of this material. During this project, 6 different geometries of slab with and without casting defect were submitted to flexional stress by punctual loading. By developing a laboratory protocol adapted to this project, digital image correlation analysis gave a multitude of very precise results. A specific attention is made to the impact of the defect on the global mechanical behavior as well as the local damaging caused by the micro-cracks.
|
12 |
Shear Contribution of Basalt Fiber-Reinforced Concrete Reinforced with Basalt Fiber-Reinforced Polymer BarsHamed, Sarah 17 April 2024 (has links)
Cette étude évalue expérimentalement et analytiquement le comportement au cisaillement des poutres en béton renforcé de fibres de basalte (BRFB) renforcées longitudinalement avec des barres en polymère renforcé de fibres de basalte (PRFB). Un nouveau type de macro-fibres de basalte a été ajouté au mélange de béton pour produire le mélange de BRFB. Quatorze poutres (152 x 254 x 2000 mm) sans armature transversale ajouté ont été testées sous une configuration de chargement à quatre points jusqu'à la défaillance. Les poutres ont été regroupés en deux groupes A et B en fonction de leurs rapports portée de cisaillement/profondeur, a/d. Les poutres du groupe A avaient un rapport a/d de 3,3 tandis que celles du groupe B avaient un rapport a/d de 2,5. Outre les rapports a/d, les paramètres étudiés comprenaient la fraction volumique des fibres ajoutées (0,75 et 1,5%) et le taux de renforcement longitudinal des barres en PRFB (0,31, 0,48, 0,69, 1,05 et 1,52). Les résultats des tests ont montré que l’ajout de macro-fibres de basalte au mélange de béton améliorait sa résistance à la compression. Une relation directe entre la fraction volumique de fibres, Vf, et la résistance à la compression a été observée. Les cylindres de béton coulés avec une Vf de 0,75 et 1,5% ont entraîné une augmentation de 11 et 30% de leur résistance à la compression par rapport à ceux moulés en béton standard (sans fibres), respectivement. L'ajout de fibres a également amélioré le mode de défaillance des poutres BRFB-PRFB que les poutres de contrôle coulées avec du béton standard. L’augmentation de la fraction volumique des fibres a réduit l’espacement entre les fissures et gêné sa propagation. Une amélioration significative des capacités de cisaillement des poutres testées a également été observée lorsque les macro-fibres de basalte ont été ajoutées à une fraction volumique Vf de 0,75. L'augmentation moyenne des capacités de cisaillement des poutres des groupes A et B, ayant les mêmes taux de renforcement, était respectivement de 45 et 44%, par rapport à celles des poutres de contrôle. Il a été noté que le gain en capacité de cisaillement des poutres testées était plus prononcé dans les poutres avec a/d= 3,3 que dans les poutres avec a/d = 2,5 lorsque le taux de renforcement augmentait. Au cours de la phase analytique, plusieurs modèles ont été utilisés pour prédire les capacités de cisaillement des poutres. Tous les modèles disponibles surestimaient les capacités de cisaillement des poutres testées avec un rapport moyen Vpre/Vexp compris entre 1,29 et 2,64. Cette observation a montré que ces modèles ne permettaient pas de prédire les capacités de cisaillement des poutres BRFB-PRFB. Un nouveau modèle modifié intégrant le type de renforcement longitudinal, le type de béton fibré et la densité du béton est proposé. Le modèle d’Ashour et al. -A (1992) a été modifié en utilisant un facteur égal au rapport entre le module des barres en PRF, Ef, et celui des barres en acier Es. Ce rapport prend en compte la différence de propriétés entre les barres en PRF et celles en acier, négligée par les modèles précédents. Le modèle proposé prédit bien les capacités de cisaillement des poutres BRFB-PRFB testées dans la présente étude avec des rapports moyens Vpre/Vexp = 0,82 ± 0,12 et 0,80 ± 0,01 pour les poutres des groupes A et B, respectivement. Les capacités de cisaillement des poutres en béton léger testées par Abbadi (2018) ont été prédites avec un rapport moyen Vpre/Vexp = 0,77 ± 0,05. De plus, le modèle prédit bien les capacités de cisaillement des poutres coulées avec du béton qui contient des fibres en acier testées par Awadallah et al. (2014) avec un rapport moyen Vpre/Vexp = 0,89 ± 0,07. Cela indique la large gamme d'applicabilité du modèle proposé. Cependant, il est recommandé d’évaluer le modèle proposé sur un ensemble de données plus large que celui présenté dans cette étude. / This study evaluates both experimentally and analytically the shear behavior of basalt fiber-reinforced concrete (BFRC) beams reinforced longitudinally with basalt fiber-reinforced polymer (BFRP) bars. A new type of basalt macro-fibers was added to the concrete mix to produce the BFRC mix. Fourteen beams (152 x 254 x 2000 mm) with no transverse reinforcement provided were tested under four-point loading configuration until failure occurred. The beams were grouped in two groups A and B depending on their span-to-depth ratios, a/d. Beams of group A had a ratio a/d of 3.3 while those of group B had a ratio a/d of 2.5. Besides the span-to-depth ratios, the parameters investigated included the volume fraction of the fibers added (0.75 and 1.5%) and the longitudinal reinforcement ratio of the BFRP reinforcing bars (0.31, 0.48, 0.69, 1.05, and 1.52). The test results showed that the addition of basalt macro-fibers to the concrete mix enhanced its compressive strength. A direct relationship between the fiber volume fraction, Vf, and the compressive strength was observed. Concrete cylinders cast with Vf of 0.75 and 1.5% yielded 11 and 30% increase in their compressive strengths over those cast with plain concrete, respectively. The addition of fibers greatly enhanced the shear capacity of BFRC-BFRP beams compared to their control beams cast with plain concrete. The increase of the fiber volume fraction decreased the spacing between cracks and hindered its propagation. A significant enhancement in the shear capacities of the tested beams was also observed when the basalt macro-fibers were added at a volume fraction Vf of 0.75%. The average increase in the shear capacities of beams of group A and B, having the same reinforcement ratios, were 45 and 44%, respectively, in comparison with those of the control beams. It was noticed that the gain in shear capacities of the tested beams was more pronounced in beams with a/d = 3.3 than in beams with a/d = 2.5 when the reinforcement ratio increased. In the analytical phase, several models were used to predict the shear capacities of the beams. All of the available models overestimated the shear capacities of the tested beams with average ratio Vpre/Vexp ranging between 1.29 to 2.64. This finding indicated that these models were not suitable to predict the shear capacities of the BFRC-BFRP beams. A new modified model incorporating the type of the longitudinal reinforcement, the type of FRC used, and the density of concrete is proposed. The model of Ashour et al. –A (1992) was calibrated using a calibration factor equal to the ratio of modulus of FRP bars used, Ef, and that of steel bars, Es. This ratio takes into consideration the difference in properties between the FRP and steel bars, which was overlooked by previous models. The proposed model predicted well the shear capacities of the BFRC-BFRP beams tested in the current study with average ratios Vpre/Vexp = 0.82 ± 0.12 and 0.80 ± 0.01 for beams of groups A and B, respectively. The shear capacities of the lightweight concrete beams tested by Abbadi (2018) were predicted with an average ratio Vpre/Vexp = 0.77 ± 0.05. Moreover, the model predicted well the shear capacities of the SFRC beams reinforced with BFRP bars tested by Awadallah et al. (2014) with an average ratio Vpre/Vexp = 0.89 ± 0.07. This indicates the wide range of applicability of the proposed model. However, it is recommended that the proposed model be assessed on larger set of data than that presented in this study
|
13 |
Shear contribution of fiber-reinforced lightweight concrete (FRLWC) reinforced with basalt fiber reinforced Polymer (BFRP) barsAbbadi, Abdulrahman 22 May 2024 (has links)
Cette étude porte sur le comportement au cisaillement des poutres en béton léger fibré et renforcées par des barres de polymère renforcé de fibres de basalte (PRFB). Dix poutres (150x250x2400 mm) coulées avec du béton fibré ou non-fibré ont été testées en flexion. Deux poutres ont été coulées sans fibres (poutres contrôles) tandis que les huit autres poutres ont été coulées avec du béton contenant des différents types et pourcentages de fibres. Les paramètres étudiés comprenaient le type de fibres ajoutés au béton (fibres de basalte, de polypropylène et d’acier), la fraction volumique des fibres (0, 0,5 et 1,0%) et les taux de renforcement des barres de PRFB (0,95 et 1,37%). Une comparaison entre les résultats expérimentaux et les modèles analytiques actuellement disponibles dans la littérature a été réalisée pour évaluer l'applicabilité de tels modèles pour prévoir la capacité des poutres testées en cisaillement. Les résultats de la présente étude indiquent que la géométrie des fibres joue un rôle important dans l'augmentation du nombre de fissures que celles observées dans les poutres contrôles. L'ajout de fibres a entraîné une défaillance plus ductile et le taux d'ouverture des fissures était retardé. La largeur de la fissure a diminué avec l'augmentation des ratios de renforcement longitudinal et des fractions volumiques des fibres. L'augmentation du taux de renforcement longitudinal a entraîné une rigidité plus élevée et a diminué les flèches à tous les stades du chargement. Les poutres coulées avec 1% de fibres de basalte, de polypropylène et d'acier ont montré une augmentation dans leurs capacités de cisaillement par rapport aux poutres contrôles d'environ 11, 16 et 63%, respectivement. Le type de fibres affectait de manière significative le gain dans les capacités de cisaillement des poutres, ce qui était attribué aux différentes propriétés physiques et mécaniques des fibres utilisées, telles que leurs dimensions, leurs géométries, et leurs mécanismes de liaison avec le béton. Les poutres coulées avec des fibres en acier à 0,5% présentaient des capacités de cisaillement plus élevées que celles coulées avec des fibres de basalte et de polypropylène de 23 et 16% respectivement, alors que les poutres coulées avec des fibres en acier à 1% de volume présentaient un gain de 47 et 41%, respectivement, dans leurs capacités. Les capacités de cisaillement prévues selon les équations de la norme CSA-S806-12 étaient conservatrices avec un rapport moyen Vprév/Vexp de 0,80 (écart type, ÉT = 0,12) pour les poutres sans fibres. Les modèles établis par Shin (1994) et Gopinath (2016) ont fourni de bonnes prévisions quant aux capacités de cisaillement des poutres en béton renforcé de fibres de basalte avec des ratios moyens Vprév/Vexp de 1,34 (ÉT = 0,09) et de 1,35 (ÉT = 0,07), respectivement. De même, le modèle de Shin (1994) a bien prédit les capacités de cisaillement des poutres en béton armé de fibres de polypropylène avec un rapport Vprév/Vexp de 1,34 (ÉT = 0,18). Les modèles de Gopinath (2016), Ashour A (1992) et Shin (1994) ont prédit les capacités de cisaillement des poutres en béton armé de fibres d'acier assez raisonnablement avec des ratio Vprév/Vexp de 1,01 (ÉT = 0,06), 1,07 (ÉT = 0,01) et 1,20 (ÉT = 0,08), respectivement. Un nouveau modèle a été proposé pour prédire les capacités de cisaillement des poutres en béton léger fibré renforcées par des barres longitudinales PRFB. Le modèle proposé prédit bien les capacités de cisaillement des poutres en béton léger (avec des fibres de basalte) avec un rapport Vprév/Vexp de 1,01 (ÉT = 0,05) et celles des poutres en béton léger (avec des fibres de polypropylène) avec un rapport Vprév/Vexp de 0,99 (ÉT = 0,06). Le facteur de liaison et la matrice de liaison d'interface utilisés étaient respectivement 0,75 et 4,18 MPa. En même temps, le modèle proposé prédit bien les capacités de cisaillement des poutres coulées avec des fibres d’acier avec un rapport Vprév/Vexp de 0,9 (ÉT = 0,00) quand le facteur de liaison et la matrice de liaison d'interface utilisés étaient respectivement 1,0 et 6,8 MPa. / This study reports on the shear behavior of fiber-reinforced lightweight concrete (FRLWC) beams reinforced with basalt fiber-reinforced polymer (BFRP) bars. Ten beams (150x250x2400 mm) cast with concrete with and without fibers were tested under fourpoint loading configuration until failure occurred. Two beams were cast without fibers and acted as control while the other eight beams were cast with different types and percentages of fiber. The investigated parameters included the fiber type (basalt, polypropylene, and steel fibers), the fibers volume fraction (0, 0.5, and 1.0%), and the beams’ reinforcement ratios (0.95 and 1.37%). Comparison between the experimental results and the analytical models currently available in the literature was performed to assess the applicability of such models for LWC reinforced with BFRP bars. Based on the outcome of the current study, the geometry of fibers played an important role in increasing the number of cracks than those observed in the control beams. The addition of fibers led to a more ductile failure and the rate of crack opening was delayed. Crack width decreased with the increase of the longitudinal reinforcement ratios and the fibers’ volume fractions. Increasing the reinforcement ratio resulted in higher stiffness and decreased its deflection at all stages of loading. Beams cast with 1% of basalt, polypropylene, and steel fibers showed an increase in their shear capacities in compared to control beams about 11, 16, and 63%, respectively. The type of fibers significantly affected the gain in the shear capacities of the beams, which can be attributed to the different physical and mechanical properties of the fibers used such as aspect ratios, lengths, geometries, densities, and their bonding mechanisms. Beams cast with 0.5% steel fibers exhibited higher shear capacities than those cast with basalt and polypropylene fibers by 23 and 16%, respectively, whereas the beams cast with 1% steel fibers showed a gain by 47 and 41%, respectively. The predicted shear capacities according to CSA-S806-12 code provisions were conservative with an average ratio Vpred /Vexp of 0.80 (standard deviation, SD = 0.12) for beams without fibers. Good predictions for the shear capacities of the basalt-fiber reinforced concrete beams (BLWC) were provided by the models derived by Shin (1994) and Gopinath (2016) in which the ratios Vpred /Vexp were 1.34 (SD = 0.09) and 1.35 (SD = 0.07), respectively. Also, the model of Shin (1994) predicted well the shear capacities of the polypropylene-fiber reinforced concrete beams (PLWC) with a Vpred /Vexp ratio of 1.34 and SD of 0.18. The models of Gopinath (2016), Ashour A (1992), and Shin (1994) predicted the shear capacities of steel-fiber reinforced concrete beams (SLWC) fairly reasonable with a Vpred /Vexp ratio of 1.01 (SD = 0.06), 1.07 (SD = 0.01) and 1.20 (SD = 0.08), respectively. A new model was proposed to predict the shear capacities of FRWLC beams reinforced with BFRP longitudinal bars. The proposed model predicted well the shear capacities of BLWC beams with a Vpred /Vexp ratio of 1.01 (SD = 0.05) and those of PLWC beams with a Vpred /Vexp ratio of 0.99 (SD = 0.06). The bond factor and the interface bond matrix used were 0.75 and 4.18 MPa, respectively. The proposed model also predicted well the shear capacities of beams cast with SLWC with a Vpred /Vexp ratio of 0.9 when the bond factor and the interface bond matrix were taken equal to 1.00 and 6.8 MPa, respectively.
|
14 |
Experimental and numerical investigation of the flexural behavior of RC slabs reinforced with BFRP bars with and without basalt fibersAttia, Karim 20 August 2024 (has links)
Cette étude évalue à la fois expérimentalement et numériquement le comportement en flexion des dalles de béton renforcées avec des barres en PRF de basalte avec et sans fibres de basalte. Les paramètres étudiés comprenaient les dosages des fibres de basalte utilisés dans le mélange de béton et les ratios du renforcement longitudinale dans les poutres. Tout d'abord, l'effet de différents dosages des fibres sur les propriétés mécaniques du béton a été évalué. Cela a été suivi par des essais de flexion qui ont été menés sur huit dalles à grande échelle chargées en quatre points. Des modèles numériques en éléments finis (ÉF) ont été élaborés à l'aide du logiciel ATENA® pour prédire le comportement en flexion des spécimens testés. Pour les résultats expérimentaux, l'augmentation du dosage des fibres de basalte a amélioré la résistance à la compression et le module de rupture du béton. Les dalles avec des dosages plus élevés de fibres ont montré une augmentation du nombre de fissures et une augmentation de leurs capacités ultimes. L'augmentation du dosage des fibres conduisait à une diminution de la ductilité des dalles testées. Cependant, toutes les dalles présentaient des indices de ductilité supérieurs à la valeur minimale exigée par la norme CAN/CSA-S6-06. Le ratio de renforcement longitudinal a eu un léger effet sur la charge de fissuration. Cependant, il contrôlait les flèches des dalles testées. Ces résultats étaient en accord avec les résultats rapportés dans la littérature pour les dalles renforcées de barres d'acier et fabriquées en béton renforcé de fibres d'acier. Un très bon accord entre les valeurs numériques et les résultats expérimentaux était obtenu. Les modèles ÉF simulaient bien le comportement en flexion des dalles en termes de charges de fissuration, des capacités, des flèches, et des configurations de fissure. Le modèle d'engagement variable a réussi à simuler le comportement du béton renforcé avec des fibres de basalte. Compte tenu du fait que ce modèle a été initialement développé pour les mélanges de béton renforcé avec des fibres d’acier, on pourrait déduire que les bétons fibrés de basalte ont un comportement comparable à celui des bétons fibrés d’acier. / This study assesses both experimentally and numerically the flexural behaviour of concrete slabs reinforced with basalt-fiber reinforced polymer (BFRP) bars cast with and without basalt fiber-reinforced concrete (BFRC). The parameters investigated included the volume fractions of the basalt fibers used in the concrete mix and the ratios of the longitudinal tensile reinforcement in the beams. First, the effect of different fiber volume fractions on the mechanical properties of concrete was assessed. This was followed by flexural tests that were conducted on eight large-scale slabs under four-point load configuration. A finite element model (FEM) was developed using ATENA® to simulate the flexural behaviour of the tested specimens. Based on the experimental results, increasing the fiber volume fraction enhanced the compressive strength and modulus of rupture of concrete. Slabs with higher dosages of fibers showed increased number of cracks and an increase in their cracking and ultimate capacities. Increasing the fiber content led to decreased ductility in the tested slabs. However, all slabs showed a ductility index that exceeded the minimum value stated by CAN/CSA-S6-06. The longitudinal reinforcement ratio had a slight effect on the cracking load. However, it governed the deflection of the tested slabs. These results were in agreement with the test results reported in the literature for slabs reinforced with steel bars and cast with conventional steel fiber-reinforced concrete (SFRC). A very good agreement between the numerical and the experimental results was obtained. The FEM predicted well the flexural behaviour of the slabs in terms of cracking loads, load-carrying capacities, deflections, and crack pattern. The Variable Engagement Model (VEM) successfully captured the behavior of the BFRC. Considering the fact that the model was initially developed for SFRC mixes, it could be concluded that BFRC has a comparable behavior to SFRC.
|
15 |
Développement d'une dalle de pont préfabriquée nervurée en béton de fibres métalliquesBergeron, Frédéric January 2013 (has links)
De façon à réduire les problématiques de circulation causées par la construction et l'entretien des ponts, les dalles de pont préfabriquées sur leur pleine épaisseur sont une alternative prometteuse à la dalle de béton conventionnel. Ce mémoire présente le développement d'un système de dalles de pont préfabriquées nervurées en béton de fibres métalliques (BFM). L’utilisation de BFM permet des dalles plus minces avec un poids beaucoup plus léger qui peut être intéressant pour certaines opérations. Le concept est d’abord validé par des tests sur des éléments de dalles et de poutres. Des essais en grandeur réelle sont ensuite effectués pour évaluer la performance de la dalle, des nervures et de deux types de joints de tablier. Il est conclu que la dalle proposée est adéquate pour supporter les charges de conception du code canadien et qu’elle peut être jusqu'à 50% plus légère qu'une dalle conventionnelle de 200 mm.
|
16 |
Modélisation du comportement des bétons fibrés à ultra-hautes performances par la micromécanique : effet de l'orientation des fibres à l'échelle de la structureGuenet, Thomas 26 July 2024 (has links)
Tableau d'honneur de la Faculté des études supérieures et postdoctorales, 2016-2017 / Cette thèse s’inscrit dans le contexte d’une optimisation industrielle et économique des éléments de structure en BFUP permettant d’en garantir la ductilité au niveau structural, tout en ajustant la quantité de fibres et en optimisant le mode de fabrication. Le modèle développé décrit explicitement la participation du renfort fibré en traction au niveau local, en enchaînant une phase de comportement écrouissante suivie d’une phase adoucissante. La loi de comportement est fonction de la densité, de l’orientation des fibres vis-à-vis des directions principales de traction, de leur élancement et d’autres paramètres matériaux usuels liés aux fibres, à la matrice cimentaire et à leur interaction. L’orientation des fibres est prise en compte à partir d’une loi de probabilité normale à une ou deux variables permettant de reproduire n’importe quelle orientation obtenue à partir d’un calcul représentatif de la mise en oeuvre du BFUP frais ou renseignée par analyse expérimentale sur prototype. Enfin, le modèle reproduit la fissuration des BFUP sur le principe des modèles de fissures diffuses et tournantes. La loi de comportement est intégrée au sein d’un logiciel de calcul de structure par éléments finis, permettant de l’utiliser comme un outil prédictif de la fiabilité et de la ductilité globale d’éléments en BFUP. Deux campagnes expérimentales ont été effectuées, une à l’Université Laval de Québec et l’autre à l’Ifsttar, Marne-la-Vallée. La première permet de valider la capacité du modèle reproduire le comportement global sous des sollicitations typiques de traction et de flexion dans des éléments structurels simples pour lesquels l’orientation préférentielle des fibres a été renseignée par tomographie. La seconde campagne expérimentale démontre les capacités du modèle dans une démarche d’optimisation, pour la fabrication de plaques nervurées relativement complexes et présentant un intérêt industriel potentiel pour lesquels différentes modalités de fabrication et des BFUP plus ou moins fibrés ont été envisagés. Le contrôle de la répartition et de l’orientation des fibres a été réalisé à partir d’essais mécaniques sur prélèvements. Les prévisions du modèle ont été confrontées au comportement structurel global et à la ductilité mis en évidence expérimentalement. Le modèle a ainsi pu être qualifié vis-à-vis des méthodes analytiques usuelles de l’ingénierie, en prenant en compte la variabilité statistique. Des pistes d’amélioration et de complément de développement ont été identifiées. / This Ph.D. project has been prepared within the context of an industrial and economic optimisation of UHPFRC structural elements to ensure ductility at the structural level, while adjusting the amount of fibre and optimising the manufacturing process. The model developed explicitly describes the participation of local fibre reinforcement in tension, thanks to a hardening behaviour followed by a softening one. The constitutive law is a function of the local fibre content, of the fibre orientation with respect to tensile principal directions, of the fibre slenderness and other usual material parameters related to the fibres, the cementitious matrix and their interaction. The fibre orientation is taken into account using a normal probability distribution with one or two variables to reproduce any orientation either obtained from a representative simulation of casting fresh UHPFRC or informed by experimental analysis on prototypes. Lastly, the model reproduces the cracking of UHPFRC based on the principle of smeared rotating crack models. The constitutive law is implemented in a structural finite element software as a predictive tool of reliability and overall ductility of UHPFRC elements. Two experimental campaigns were carried out, one at Laval University in Québec and one at Ifsttar, Marne-la-Vallée. The first one is used to confirm the model ability to reproducethe overall behaviour under typical tensile and bending loads in simple structural elements for which the preferential fibre orientation was measured by microtomography. The second experimental campaign demonstrates the capabilities of the model, in an optimisation process, to help manufacture relatively complex ribbed triangular plates of industrial interest in which different manufacturing process and fibre volume have been considered. The identification of fibre distribution and orientation has been performed using mechanical tests on sawn samples. The model predictions have been compared to the global structural behaviour, and to the ductility demonstrated experimentally. The model could be qualified through comparison with conventional analytical engineering methods, taking into account the statistical variability. Improvement and additional developments have been identified.
|
17 |
Thermographie et shearographie appliquées au contrôle non-destructif d'interfaces entre de l'adhésif époxy et du CFRPThéroux, Louis-Daniel 20 April 2018 (has links)
Le sujet de ce mémoire porte sur l'étude du contrôle non-destructif de structure de béton renforcé par collage de CFRP (carbon fiber reinforced polymer) par shearographie et thermographie active couplées. La méthode d'excitation utilisée conjointement lors de la mise en œuvre de ces deux méthodes est un rayonnement thermique conditionné temporellement par un signal carré. L'observation du champ des températures de surface et des déplacements hors plan de la surface permet la détection et la caractérisation de défauts. Dans un premier temps, des tests de faisabilité ont été conduits pour valider si l'utilisation d’une contrainte thermique de type créneau autorisait des mesures shearographiques (cela ayant été déjà validé dans le cas de la thermographie infrarouge active). Cette série de test s’étant avérée concluante, une étude numérique par modélisation aux éléments finis a été réalisée sous Comsol®. Cette étude numérique a permis de mieux appréhender les résultats obtenus expérimentalement mais aussi de conduire une étude de l’influence de différents paramètres. Des outils d'analyses ont été développés et ont permis de mettre en évidence, entre autre, qu'une évaluation quantitative des défauts était possible.
|
Page generated in 0.0767 seconds